Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Magnetic domain engineering in SrRuO3 thin films

Abstract Magnetic domain engineering in ferromagnetic thin films is a very important route toward the rational design of spintronics and memory devices. Although the magnetic domain formation has been extensively studied, artificial control of magnetic domain remains challenging. Here, we present the control of magnetic domain formation in paradigmatic SrRuO 3 /SrTiO 3 heterostructures via structural domain engineering. The formation of structural twin domains in SrRuO 3 films can be well controlled by breaking the SrTiO 3 substrate symmetry through engineering miscut direction. The combination of x-ray diffraction analysis of structural twin domains and magnetic imaging of reversal process demonstrates a one-to-one correspondence between structural domains and magnetic domains, which results in multi-step magnetization switching and anomalous Hall effect in films with twin domains. Our work sheds light on the control of the magnetic domain formation via structural domain engineering, which will pave a path toward desired properties and devices applications.

Materials Science↗

A compact electromagnetic neutron nutator for precise neutron spin manipulation

A superconducting electromagnetic nutator (EMN) capable of generating a magnetic field vector along an arbitrary direction on a 2D plane has been designed. Its performance in precisely manipulating the neutron polarization vector has been tested at the HB2-D polarized development beamline at the High Flux Isotope Reactor. Unlike mechanical nutators that require physical handling or motor-driven actuation to rotate the magnetic field, the magnitude and orientation of the magnetic field produced by the EMN can be controlled electromagnetically. Further, the compact design (~15 mm depth, not including cryogenic housing) of this device ensures ease of coupling within existing superconducting neutron spin manipulation devices, such as magnetic Wollaston prisms (MWP), resonant radio frequency (RF) flippers, spherical neutron polarimetry (SNP) devices, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct measurement of reduced exchange stiffness and its impact on magnetic vortex behavior in PyGd alloys

Thin films composed of sputtered transition metal/rare earth (TM/RE) ferrimagnets have emerged as promising building blocks for future spintronic devices, offering tunable magnetic properties critical for data storage, memory, and logic applications. However, understanding how the combination of TM and RE elements influences effective magnetic properties, such as exchange stiffness (Aex), remains challenging. Magnetic vortices provide a versatile tool for probing these properties in thin film systems. By combining magnetic imaging via soft x-ray microscopy and micromagnetic modeling, we quantify the effective exchange stiffness in PyGd ferrimagnetic disks with varying Gd concentrations. Our results indicate a reduction in Aex to below 3 pJ/m for a 20% Gd concentration when compared to reference Py, and values below 2 pJ/m for 30% Gd, reflecting weak Ni–Gd exchange coupling. These findings highlight the critical role of rare earth content in tuning the exchange stiffness. The reduced exchange stiffness facilitates a linear field response of the magnetization up to the edge of the disk, as well as significant deformations in the vortex core itself when compared to films with larger Aex. Our results are in line with, albeit lower than, recent measurements of the exchange stiffness in intermixed PyGd. This reduced exchange stiffness has implications for the development of spintronic devices based on ferrimagnetic skyrmions.

Jacob, Liyan↗

First principles study of nearly strain-free Ni/WSe 2 and Ni/MoS 2 interfaces

Metal/transition metal dichalcogenide interfaces are the subject of active research, in part because they provide various possibilities for interplay of electronic and magnetic properties with potential device applications. Here, we present results of our first principles calculations of nearly strain-free Ni/WSe 2 and Ni/MoS 2 interfaces in thin-film geometry. It is shown that while both the WSe 2 and MoS 2 layers adjacent to Ni undergo metallic transition, the layers farther from the interface remain semiconducting. In addition, a moderate value of spin-polarization is induced on interfacial WSe 2 and MoS 2 layers. At the same time, the electronic and magnetic properties of Ni are nearly unaffected by the presence of WSe 2 and MoS 2 , except a small reduction of magnetic moment at the interfacial Ni atoms. Furthermore, these results can be used as a reference for experimental efforts on epitaxial metal/transition metal dichalcogenide heterostructures, with potential application in modern magnetic storage devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic tunnel junctions with voltage tunable interlayer coupling for memory and sensor applications

Various examples are provided for magnetic tunnel junctions and applications thereof. In one example, a magnetic tunnel junction (MTJ) device includes a first ferromagnetic (FM) layer; a gadolinium oxide (GdOX) tunnel barrier disposed on the first ferromagnetic layer; and a second FM layer disposed on the GdOX tunnel barrier. In another example, a perpendicular MTJ (pMTJ) device includes a first layer including a magnetic material; a tunnel barrier disposed on the first layer to form the pMTJ; and a second layer including the magnetic material, the second layer disposed on the tunnel barrier.

Wang, Weigang↗

Effect of insulator end cap thickness on time-dependent Hartmann flow in a rotating mirror

We present a framework for analysing plasma flow in a rotating mirror. By making a series of physical assumptions, we reduce the magnetohydrodynamic (MHD) equations in a three-dimensional cylindrical system to a one-dimensional system in a shallow, cuboidal channel within a transverse magnetic field, similar to the Hartmann flow in ducts. We then solve the system both numerically and analytically for a range of values of the Hartmann number and calculate the dependence of the plasma flow speed on the thickness of the insulating end cap. We observe that the mean flow overshoots and decelerates before achieving a steady-state value, a phenomenon that the analytical model cannot capture. This overshoot is directly proportional to the thickness of the insulating end cap and the external electric field, with a weak dependence on the external magnetic field. Our simplified model can act as a benchmark for future simulations of the supersonic mirror device CMFX (centrifugal magnetic fusion experiment), which will employ more sophisticated physics and realistic magnetic field geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scalable Multiphysics Block Preconditioning for Low Mach Number Compressible Resistive MHD with Application to Magnetic Confinement Fusion

This study investigates multiphysics block preconditioners that are critical in devising scalable Newton–Krylov iterative solvers for longer time-scale fully implicit fluid plasma models. The specific model of interest is the visco-resistive, low Mach number, compressible magnetohydrodynamics (MHD) model. This model describes the dynamics of conducting fluids in the presence of electromagnetic fields and can be used to study aspects of astrophysical phenomena, important science and technology applications, and basic plasma physics. The specific application of interest that motivates this study is the macroscopic simulation of longer time-scale stability and disruptions of magnetic confinement fusion devices, specifically the ITER Tokamak. The computational solution of the governing balance equations for mass, momentum, heat transfer, and magnetic induction for resistive MHD systems can be extremely challenging. These difficulties arise from both the strong nonlinear, nonsymmetric coupling of fluid and electromagnetic phenomena as well as the significant range of time and length scales that the interactions of these physical mechanisms produce. To handle the range of time and spatial scales of interest, a fully implicit unstructured variational multiscale finite element formulation is employed. For the scalable solution of the Newton linearized systems, fully coupled block preconditioners are designed to leverage algebraic multigrid subsolves. In conclusion, results are presented for the strong and weak scaling of the method as well as the robustness of these techniques for a large range of Lundquist numbers.

97 MATHEMATICS AND COMPUTING↗

Design, construction, and testing of no-insulation small subscale solenoids for compact tokamaks

Fusion energy systems studies (FESS) for next-step devices based on the most promising magnetic configurations indicate that high magnetic fields and high current density for magnet coil systems may reduce device size and lower the cost. High current density and radiation resistant fusion magnets are particularly beneficial for low cost, low aspect ratio compact reactor designs such as Fusion Nuclear Science Facility (FNSF), Fusion Pilot Plant (FPP) of low-aspect ratio spherical tokamak (ST) or compact stellarators. Unlike typical high field magnets for nuclear magnetic resonance (NMR), magnetic resonance imaging (MRI), or high energy physics research applications, neutron irradiation damage to organic insulations in the coil winding pack is a critical issue for next generation fusion reactors where orders of magnitude higher neutron fluence than those in present experimental reactors such as ITER are expected. Moreover, a high coil winding pack current density is needed for high field magnets in low cost, compact radial build next step fusion reactors. The slow current charging time, however, is an issue in fully non-insulated coils. In this work, we present the design, construction and testing of subscale Nb3Sn solenoids, up to half the diameter of the central solenoid (CS) for National Spherical Torus Experiment (NSTX), with and without inter-layer insulation for enhancing radiation resistance while improving the winding pack current density and coil performance. The major radius for the NSTX/NSTX-Upgrade (reference for compact ST) is 0.854/0.934 meter, and 4.8 meters for FNSF. The magnetic field for NSTX/NSTX-U at the plasma center is 0.6/1 Tesla and 9 Tesla for FNSF. The inner diameter of the central solenoid coil is 0.2/0.4 meter for NSTX/NSTX-U and 1.2 meters for FNSF. The current charging and discharging behavior of the prototype solenoids was investigated to quantify performance advantages of a simplified coil fabrication without error-prone vacuum pressure impregnation (VPI) for the removal of epoxy organic insulation. Scalability of the no insulation concept for fusion can be addressed via engineered coating for novel insulation on contact resistance or intra-layer no insulations. Radiation resistance and coil winding efficiency were significantly improved in the no insulation coils for next step compact fusion reactors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heavy-ion-induced displacement damage effects in magnetic tunnel junctions with perpendicular anisotropy

Here, we evaluate the resilience of CoFeB/MgO/CoFeB magnetic tunnel junctions (MTJs) with perpendicular magnetic anisotropy to displacement damage induced by heavy ion irradiation. MTJs were exposed to 3 MeV Ta 2+ ions at different levels of ion beam fluence spanning five orders of magnitude. The devices remained insensitive to beam fluences up to 10 11 ions/cm 2 , beyond which a gradual degradation in the device magnetoresistance, coercive magnetic field, and spin-transfer-torque switching voltage were observed, ending with a complete loss of magnetoresistance at very high levels of displacement damage (>0.035 displacements per atom). The loss of magnetoresistance is attributed to structural damage at the MgO interfaces, which allows electrons to scatter among the propagating modes within the tunnel barrier and reduces the net spin polarization. Ion-induced damage to the interface also reduces the perpendicular magnetic anisotropy. This study clarifies the displacement damage thresholds that lead to significant irreversible changes in the characteristics of spin-transfer-torque magnetic random access memory (STT-MRAM) and elucidates the physical mechanisms underlying the deterioration in device properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonvolatile Magnetoelectric Switching of Magnetic Tunnel Junctions with Dipole Interaction

The magnetoelectric effect is technologically appealing because of its ability to manipulate magnetism using an electric field rather than magnetic field or current, thus providing a promising solution for the development of energy-efficient spintronics. Although 180° magnetization switching is vital to spintronic devices, the achievement of 180° magnetization switching via magnetoelectric coupling is still a fundamental challenge. Here, in this work, voltage-driven full resistance switching of a magnetic tunnel junction (MTJ) with dipole interaction on a ferroelectric substrate through switchable parallel/antiparallel magnetization alignment is demonstrated. Parallel magnetization alignment along the y direction is obtained under a bias magnetic field. By rotating the magnetic easy axis via strain-mediated magnetoelectric coupling, the parallel magnetizations in the MTJ reorient to the x axis with opposite paths because of dipole interaction, thus resulting in antiparallel alignment. Moreover, this voltage switching of MTJs is nonvolatile owing to variations in dipole interaction and can be well understood via phase field simulations. The results provide an avenue to realize electrical switching of MTJs and are significant for exploring energy-efficient spintronic devices.

36 MATERIALS SCIENCE↗

Surrogate approximation of the Grad–Shafranov free boundary problem via stochastic collocation on sparse grids

In magnetic confinement fusion devices, the equilibrium configuration of a plasma is determined by the balance between the hydrostatic pressure in the fluid and the magnetic forces generated by an array of external coils and the plasma itself. The location of the plasma is not known a priori and must be obtained as the solution to a free boundary problem. The partial differential equation that determines the behavior of the combined magnetic field depends on a set of physical parameters (location of the coils, intensity of the electric currents going through them, magnetic permeability, etc.) that are subject to uncertainty and variability. The confinement region is in turn a function of these stochastic parameters as well. In this work, we consider variations on the current intensities running through the external coils as the dominant source of uncertainty. This leads to a parameter space of dimension equal to the number of coils in the reactor. With the aid of a surrogate function built on a sparse grid in parameter space, a Monte Carlo strategy is used to explore the effect that stochasticity in the parameters has on important features of the plasma boundary such as the location of the x-point, the strike points, and shaping attributes such as triangularity and elongation. Furthermore, the use of the surrogate function reduces the time required for the Monte Carlo simulations by factors that range between 7 and over 30.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic-flux pump

A magnetic flux pump is described for increasing the intensity of a magnetic field by transferring flux from one location to the magnetic field. The device includes a pair of communicating cavities formed in a block of superconducting material, and a piston for displacing the trapped magnetic flux into the secondary cavity producing a field having an intense flux density.

Hildebrandt, A. F.↗

Critical role of orbital hybridization in the Dzyaloshinskii-Moriya interaction of magnetic interfaces

Dzyaloshinskii-Moriya interaction (DMI), an interfacial spin-orbit coupling (ISOC)-related effect, has become foundational for spintronic research and magnetic memory and computing technologies. However, the underlying mechanism of DMI, including the quantitative role of ISOC, has remained a long-standing unsettled problem due to the great challenge in quantifying and widely tuning ISOC strength in a strong DMI material system. Here, we find that DMI, ISOC, and orbital hybridization at the model magnetic interface Au 1-x Pt x /Co can be quantified and tuned significantly at the same time through the composition of the Au 1-x Pt x , without varying the bulk SOC and the electronegativity. From this ability, we establish that the widespread expectation that DMI should scale in linear proportion to ISOC breaks down at the Au 1-x Pt x /Co interface where degree of orbital hybridization varies with the Au 1-x Pt x composition and that the unexpected DMI behaviors can be understood well by the critical role of orbital hybridization. Our study provides a quantitative frame for comprehensively understanding interfacial DMI of various magnetic interfaces and establishes orbital hybridization as a new degree of freedom for controlling DMI in high-performance chiral domain wall/skyrmion devices and ultrafast magnetic tunnel junctions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

Communications Transceivers for Venus Surface Missions

The high temperature of the surface of Venus poses many difficulties. Previous Venus landers have only operated for short durations before succumbing to the heat. NASA Glenn Research Center conducted a study on communications for long duration Venus surface missions. I report the findings in this presentation. Current technology allows production of communications transceivers that can operate on the surface of Venus, at temperatures above 450 C and pressures of over 90 atmospheres. While these transceivers would have to be relatively simple, without much of the advanced signal processing often used in modern transceivers, since current and near future integrated circuits cannot operate at such high temperatures, the transceivers will be able to meet the requirements of proposed Venus Surface mission. The communication bands of interest are High Frequency or Very High Frequency (HFNHF) for communication between Venus surface and airborne probes (including surface to surface and air to air), and Ultra High Frequency (UHF) to Microwave bands for communication to orbiters. For HFNHF, transceivers could use existing vacuum tube technology. The packaging of the vacuum tubes may need modification, but the internal operating structure already operates at high temperatures. Using metal vacuum structures instead of glass, allows operation at high pressure. Wide bandgap transistors and diodes may be able to replace some of the thermionic components. VHF communications would be useful for line-of- sight operations, while HF would be useful for short-wave type communications using the Venusian ionosphere. UHF and microwave communications use magnetically focused thermionic devices, such as traveling wave tubes (TWTs), magnetron (M-type) amplifiers, and klystrons for high power amplifiers, and backward wave oscillators (BWOs) and reflex klystrons for oscillators. Permanent magnets are already in use in industry that can operate at 500 C. These magnets could focus electron beam tubes on the surface of Venus. While microwave windows will need to be designed for the high pressure, diamond windows have already been demonstrated, so high-pressure microwave windows can be designed and built. Thus, all of these devices could be useful for Venus surface missions. Current electronic power conditioners to supply the high voltages used in these microwave devices cannot operate at high temperatures, but earlier electronic power conditioners that used vacuum tubes can be modified to work at high temperature. Evaluating the various devices in this study, the M-type traveling wave tube (where a traveling wave structure is used in a crossed-field device, similar to the Amplitron used on the Apollo missions) stood out for the high power amplifier since it requires a single high voltage, simplifying the power supply design. Since the receiver amplifier is a low power amplifier, the loss of efficiency in linear beam devices without a depressed collector (and thus needing a single high voltage) is not important; a low noise TWT is a possible solution. Before solid-state microwave amplifiers were available, such TWTs were built with a 1-2 dB noise figure. A microwave triode or transistor made from a wide bandgap material may be preferable, if available. Much of the development work needed for Venusian communication devices will need to focus on the packaging of the devices, and their connections, but the technology is available to build transceivers that can operate on the surface of Venus indefinitely.

Force, Dale A.↗

Evaluation of passive and active vibration control mechanisms in a microgravity environment

The behavior of equipment and their light secondary attachments in large space structures under orbital excitation is studied. The equipment is modeled as a shear beam and its secondary attachment is treated as a single-degree-of-freedom lumped mass system. Peak responses of the equipment and its secondary system for a variety of vibration control mechanisms are evaluated. A novel active friction control mechanism, by varying the normal force, is suggested. The device uses a magnetic field control to minimize the stick condition, thereby reducing the overall structural response. The results show that the use of the passive vibration control devices could reduce the peak equipment responses to a certain extent. However, major reduction of vibration levels could be achieved only by the use of active devices. Using active control of the interface normal force, the peak responses of the equipment and its attachment are reduced by a factor of 10 over the fixed-base equipment response.

Ellison, J.↗

System and method for the recycling of rare earth magnets

A system and a method for separating and recycling magnets made from rare earth elements from an article of manufacture used an alignment device to property position the rare earth magnet for processing. Once proper alignment is made, a separating device removes the magnet and a portion of the article. A heating device demagnetizes the magnets and vibration causes the magnets to separate from the portion of the article. Electromagnets remove the portion of the article and the rare earth magnets pass through for reclamation.

42 ENGINEERING↗

System and method for the recycling of rare earth magnets

A system and a method for separating and recycling magnets made from rare earth elements from an article of manufacture used an alignment device to property position the rare earth magnet for processing. Once proper alignment is made, a separating device removes the magnet and a portion of the article. A heating device demagnetizes the magnets and vibration causes the magnets to separate from the portion of the article. Electromagnets remove the portion of the article and the rare earth magnets pass through for reclamation.

McIntyre, Timothy J.↗