Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mass spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Huygens Gas Chromatograph Mass Spectrometer Results from Titan

The Huygens Probe executed a successful entry, descent and impact on the Saturnian moon of Titan on January 14, 2005. Gas Chromatograph Mass Spectrometer (GCMS) instrument conducted isotopic and compositional measurements throughout the two and one half hour descent from 146 km altitude, and on the surface for 69 minutes until loss of signal from the orbiting Cassini spacecraft. The GCMS incorporated a quadrupole mass filter with a secondary electron multiplier detection system. The gas sampling system provided continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact. Data products from the GCMS included altitude profiles of the major atmospheric constituents dinitrogen (N2) and methane (CH4), isotope ratios of N-14/N-15, C-12/C-13, and D/H, mole fractions of radiogenic argon (Ar-40)and primordial argon Ar-36), and upper limits on the mole fractions of neon, krypton and xenon, which were found to be below the detection limit of the instrument or absent. Surface measurements confirmed the presence of ethane (C2H6) and cyanogen (C2N2). Later data products include the instrument response to surface outgassing of C2N2, C2H6, acetylene (C2H2),and carbon dioxide (CO2). More recent results include the detection of benzene (C6H6) and height profiles of molecular hydrogen (H2). Numerous other trace species evaporating from the surface were also identified using the GCMS data.

Niemann, Hasso↗

Observations of the Nightside Venus Ionosphere: Final Encounter of the Pioneer Venus Orbiter Ion Mass Spectrometer

During the last orbital sequences of the Pioneer Venus spacecraft prior to final encounter and atmospheric entry, data were obtained by the Orbiter Ion Mass Spectrometer (OIMS) at the lowest periapsis altitudes of the mission. These data verified OIMS observations of the nightside ionospheric peak reported-earlier in the mission, and revealed additional details related to composition, energetics and maintenance of the nightside ionosphere. OIMS observations of the ion peak during the final encounter sequence are compared with radio occultation data and OIMS peak observations obtained earlier. OIMS ion density and Orbiter Electron Temperature Probe (OETP) electron density are found to correlate near the peak. Coupling of mass channels 30 and 32 during nightside passes is observed and its interpretation considered. Changes in high altitude composition of the nightside ionosphere, especially the relative changes in O(+) and H(+), are described.

Cloutier, P. A.↗

Observations of the nightside Venus ionosphere: Final encounter of the Pioneer Venus Orbiter Ion Mass Spectrometer

During the last orbital sequences of the Pioneer-Venus spacecraft prior to final encounter and atmospheric entry, data were obtained by the Orbiter Ion Mass Spectrometer (OIMS) at the lowest periapsis altitudes of the mission. These data verified OIMS observations of the nightside ionospheric peak reported earlier in the mission, and revealed additional details related to composition, energetics and maintenance of the nightside ionosphere. OIMS observations of the ion peak during the final encounter sequence are compared with radio occultation data and OIMS peak observations obtained earlier. OIMS ion density and Orbiter Electron Temperature Probe (OETP) electron density are found to correlate near the peak. Coupling of mass channels 30 and 32 during nightside passes is observed and its interpretation considered. Changes in high altitude composition of the nightside ionosphere, especially the relative changes in O(+) and H(+), are described.

Cloutier, P. A.↗

Autonomous Ion Mass Spectrometer Sentry (AIMSS)

Satellite measurements of plasma density and temperature help predict the intensity of geomagnetic storms, which can impact satellites, communications, and power systems. Accurate forecasting requires knowledge of plasma composition. However, typical orbital mass spectrometers have difficulty distinguishing between nitrogen (N+) and oxygen (O+) ions due to their similar masses. This limitation makes it difficult to validate modern space weather models, which depend on accurate knowledge of ion composition in near-Earth space. N+ and O+ ions behave differently in space due to differences in their origin, transport, and loss mechanisms. Improving our ability to distinguish between these ions is critical for understanding and predicting space weather.

47 OTHER INSTRUMENTATION↗

Ion Trap Mass Spectrometers for Identity, Abundance and Behavior of Volatiles on the Moon

NASA GSFC and The Open University (UK) are collaborating to deploy an Ion Trap Mass Spectrometer on the Moon to investigate the lunar water cycle. The ITMS is flight-proven throughthe Rosetta Philae comet lander mission. It is also being developed under ESA funding to analyse samples drilled from beneath the lunar surface on the Roscosmos Luna-27 lander (2025).Now, GSFC and OU will now develop a compact ITMS instrument to study the near-surface lunar exosphere on board a CLPS Astrobotic lander at Lacus Mortis in 2021.

Barber, S. J.↗

SCILLA mini-Aerosol Mass Spectrometer (mAMS) airborne data

Measurements of non-refractory, sub-micron aerosol composition, namely organic, sulfate, nitrate, chloride, and ammonium aerosols, by a mini- aerosol mass spectrometer (mAMS, Aerodyne Research, Inc.) are reported. The instrument sampled ambient air through 3 different inlets: unperturbed ambient air, a Counter-flow Virtual Impactor (CVI), and an oxidation flow reactor (OFR). Users should consult the Sampling Key for proper interpretation of the data.

and secondary aerosol in air",total_organics,nitra↗

The Galileo probe mass spectrometer: composition of Jupiter's atmosphere

The composition of the jovian atmosphere from 0.5 to 21 bars along the descent trajectory was determined by a quadrupole mass spectrometer on the Galileo probe. The mixing ratio of He (helium) to H2 (hydrogen), 0.156, is close to the solar ratio. The abundances of methane, water, argon, neon, and hydrogen sulfide were measured; krypton and xenon were detected. As measured in the jovian atmosphere, the amount of carbon is 2.9 times the solar abundance relative to H2, the amount of sulfur is greater than the solar abundance, and the amount of oxygen is much less than the solar abundance. The neon abundance compared with that of hydrogen is about an order of magnitude less than the solar abundance. Isotopic ratios of carbon and the noble gases are consistent with solar values. The measured ratio of deuterium to hydrogen (D/H) of (5 +/- 2) x 10(-5) indicates that this ratio is greater in solar-system hydrogen than in local interstellar hydrogen, and the 3He/4He ratio of (1.1 +/- 0.2) x 10(-4) provides a new value for protosolar (solar nebula) helium isotopes. Together, the D/H and 3He/4He ratios are consistent with conversion in the sun of protosolar deuterium to present-day 3He.

NASA Discipline Number 52-10↗

Galileo Probe Mass Spectrometer

During the past year, the Principal Investigator's research carried out under this contract has focused on an analysis of the implications of Galileo Probe Mass Spectrometer (GPMS) results for the origin of Jupiter's atmosphere and the origin of the ice and other possible volatiles on the Galilean satellites.

Owen, Tobias C.↗

Wave-like perturbations observed at low altitudes by the Pioneer Venus Orbiter Neutral Mass Spectrometer during orbiter entry

Wave-like perturbations have been observed in the nightside neutral density data acquired for He, N, O, N2 and CO2 by the Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) during entry in late 1992. The data cover an altitude range of 133-200 km from 0.5-4.5 hours local solar time and occur at medium solar activity (F(sub 10.7) = 120). The perturbations, with an effective wavelength along the orbit of about 100 to 600 km, have similar amplitudes for the various species and helium is out of phase with respect to the heavier mass species. The measurements are comparable to those observed in 1978-80 at solar maximum activity (F(sub 10.7) = 200) above 145 km. Between 133 and 160 km the rms amplitudes grow with altitude at a rate of about (1.6, 2.1, 2.7, 4.4) x 10(exp 3)/km for N, O, N2, and CO2, respectively. The average rms amplitudes above 145 km of 0.08 for N and O and 0.1 for N2 are comparable in magnitude to those observed in the earlier 1978-80 data of 0.06, 0.08, and 0.095 respectively. CO2 is an exception for which the entry value is 0.17 compared to 0.09 earlier. By combining the two overlapping data sets there is a suggestion that the CO2 amplitudes grow in value with altitude up to about 140-170 km and then decrease in amplitude. Like the earlier data, the entry data are consistent with the interpretation that the neutral density perturbations are due to gravity waves propagating upward from the lower thermosphere.

Kasprzak, W. T.↗

Wave-Like Perturbations Observed at Low Altitudes by the Pioneer Venus Orbiter Neutral Mass Spectrometer During Orbiter Entry

Wave-like perturbations have been observed in the nightside neutral density data acquired for He, N, O, N2 and CO2 by the Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) during entry in late 1992. The data cover an altitude range of 133-200 km from 0.5-4.5 hours local solar time and occur at medium solar activity (F(sub 10.7) = 120) The perturbations, with an effective wavelength along the orbit of about 100 to 600 km, have similar amplitudes for the various species and helium is out of phase with respect to the heavier mass species. The measurements are comparable to those observed in 1978-80 at solar maximum activity (F(sub 10.7) = 200) above 145 km. Between 133 and 160 km the rms amplitudes grow with altitude at a rate of about (1.6, 2.1, 2.7, 4.4) x 10(exp -3)/ km for N, O, N2, and CO2 respectively. The average rms amplitudes above 145 km of 0.08 for N and O and 0.1 for N2 are comparable in magnitude to those observed in the earlier 1978-80 data of 0.06, 0.08 and 0.095 respectively. CO2 is an exception for which the entry value is 0.17 compared to 0.09 earlier. By combining the two overlapping data sets there is a suggestion that the CO2 amplitudes grow in value with altitude up to about 140-170 km and then decrease in amplitude. Like the earlier data, the entry data are consistent with the interpretation that the neutral density perturbations are due to gravity waves propagating upward from the lower thermosphere. Earlier data sampled a higher altitude region where dissipation is important in limiting and ultimately reversing the growth of gravity waves while the lower altitude entry data probed the region where growth of these waves can be observed.

Kasprzak, W. T.↗

Composition of hot ions /0.1-16 keV/e/ as observed by the GEOS and ISEE mass spectrometers and inferences for the origin and circulation of magnetospheric plasmas

The composition of hot magnetospheric plasma through different regions of the magnetosphere is described on the basis of mass spectrometer measurements by the GEOS 1, GEOS 2, and ISEE-1 spacecraft. Coordinated composition measurements on the different spacecraft also provide information on the spatial and temporal characteristics of the plasma during storms. Data on ion origins are also provided.

Balsiger, H.↗

The role of fiber optics in mass spectrometer electro-optical ion detection

This paper describes the development of an electro-optical ion detector combining the best features of photographic and electrical ion detection (i.e., wide mass range coverage and low ion detection threshold respectively). A nineteen fold fiber optic image dissector is discussed which reformats the 1 mm x 361 mm mass spectrometer focal plane format to a 19 mm x 19 mm format suitable for vidicon imaging and electronic display of the data.

Norris, D. D.↗

The mass dependence of wave particle interactions as observed with the ISEE-1 energetic ion mass spectrometer

Simultaneous measurements of the O(+) and H(+) distributions from two transverse acceleration events in the high altitude auroral ionosphere are presented. The data were acquired from the energetic ion mass spectrometer on the ISEE-1 satellite, in the dusk sector, on auroral field lines (L = 8-9), at geocentric radial distances of about 3 earth radii. Temporal and/or spatial fluctuations during the measurement cycle resulted in some scatter of the data points, but the transverse velocity distributions are reasonably well represented by maxwellians at energies in the few hundred eV range. The transverse temperatures were about 60 eV in both cases and no significant differences were observed between the temperatures of the O(+) and H(+). The flux intensities of the two ion species were also generally comparable.

Sharp, R. D.↗

Evaluating Mass Analyzers as Candidates for Small, Portable, Rugged Single Point Mass Spectrometers for Analysis of Permanent Gases

For Space Shuttle launch safety, there is a need to monitor the concentration of H2, He, O2 and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida. The System Volume is determined by measuring the entire system volume including the mass analyzer, its associated electronics, the associated vacuum system, the high vacuum pump and rough pump. Also measured are any ion gauge controllers or other required equipment. Computers are not included. Scan Time is the time required for one scan to be acquired and the data to be transferred. It is determined by measuring the time required acquiring a known number of scans and dividing by said number of scans. Limit of Detection is determined first by performing a zero-span calibration (using a 10-point data set). Then the limit of detection (LOD) is defined as 3 times the standard deviation of the zero data set. (An LOD of 10 ppm or less is considered acceptable.)

Arkin, C. Richard↗

The Co2 Profile and Analytical Model for the Pioneer Venus Large Probe Neutral Mass Spectrometer

We present a significantly updated CO2 altitude profile for Venus (64.2–0.9 km) and provide support for a potential deep lower atmospheric haze of particles (≤17 km). We extracted this information by developing a new analytical model for mass spectra obtained by the Pioneer Venus Large Probe (PVLP) Neutral Mass Spectrometer (LNMS). Our model accounts for changes in LNMS configuration and output during descent and enables the disentanglement of isobaric species via a data fitting routine that adjusts for mass-dependent changes in peak shape. The model yields CO2 in units of density (kg m−3), isotope ratios for 13C/12C and 18O/16O, and 14 measures of CO2 density across 55.4–0.9 km, which represents the most complete altitude profile for CO2 at ≤60 km to date. The CO2 density profile is also consistent with the pressure, temperature, and volumetric gas measurements from the PVLP and VeNeRa spacecraft. Nominal and low-noise operations for the LNMS mass analyzer are supported by the behaviors (e.g., ionization yields, fragmentation yields, and peak shapes) of several internal standards (e.g., CH3+, CH4+, 40Ar+, 136Xe2+, and 136Xe+), which were tracked across the descent. Lastly, our review of the CO2 profile and LNMS spectra reveals hitherto unreported partial and rapidly clearing clogs of the inlet in the lower atmosphere, along with several ensuing data spikes at multiple masses. Together, these observations suggest that atmospheric intake was impacted by particles at ≤17 km and that rapid particle degradation at the inlet yielded a temporary influx of mass signals into the LNMS.

Venus↗

Evaluating Mass Analyzers as Candidates for Small, Portable, Rugged Single Point Mass Spectrometers for Analysis of Permanent Gases

For Space Shuttle launch safety, there is a need to monitor the concentration Of H2, He, O2, and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida.

Arkin, C. Richard↗