Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Crystal Graph Convolutional Neural Networks for an Accurate and Interpretable Prediction of Material Properties

The use of machine learning methods for accelerating the design of crystalline materials usually requires manually constructed feature vectors or complex transformation of atom coordinates to input the crystal structure, which either constrains the model to certain crystal types or makes it difficult to provide chemical insights. Here, we develop a crystal graph convolutional neural networks framework to directly learn material properties from the connection of atoms in the crystal, providing a universal and interpretable representation of crystalline materials. Our method provides a highly accurate prediction of density functional theory calculated properties for eight different properties of crystals with various structure types and compositions after being trained with 10 4 data points. Further, our framework is interpretable because one can extract the contributions from local chemical environments to global properties. Using an example of perovskites, we show how this information can be utilized to discover empirical rules for materials design.

36 MATERIALS SCIENCE↗

EXAFS spectroscopy of quasicrystals

The results of the investigation of the features of the local structure of quasicrystalline materials by extended X-ray absorption fine structure (EXAFS) spectroscopy with the use of synchrotron radiation are analyzed. The advantages of this method from the point of view of deriving information about the local shifts of the atoms forming an icosahedral structure are demonstrated. The rearrangement of the local environment of copper and iron in Al-Fe-Cu ternary alloys at a transition from the crystalline to the quasicrystalline phase has been investigated. It is established that the nearest copper coordination retains the symmetry characteristic of the crystal; however, rotation and small displacements of copper matrix atoms lead to significant rearrangement of aluminum atoms around iron atoms. As a result, icosahedral clusters with pentagonal symmetry are formed around iron atoms and violation of the translational symmetry is accompanied by the transition of Al-Fe-Cu to the quasicrystalline state.

36 MATERIALS SCIENCE↗

Laser interferometric method for determining the carrier diffusion length in semiconductors

A new laser interferometric method for measuring the carrier diffusion length in semiconductors is proposed. The method is based on the interference–absorption interaction of two laser radiations in a semiconductor. Injected radiation generates additional carriers in a semiconductor, which causes a change in the material’s optical constants and modulation of the probing radiation passed through the sample. When changing the distance between carrier generation and probing points, a decrease in the carrier concentration, which depends on the diffusion length, is recorded. The diffusion length is determined by comparing the experimental and theoretical dependences of the probe signal on the divergence of the injector and probe beams. The method is successfully tested on semiconductor samples with different thicknesses and surface states and can be used in scientific research and the electronics industry.

36 MATERIALS SCIENCE↗

Development of and initial assessment of microstructurally engineered UN

Fuels with high uranium densities have been considered in the Nuclear Technology Research and Development program’s Advanced Fuels Campaign as potential replacements for uranium(IV) oxide in commercial light water reactors. One such candidate fuel is uranium mononitride, UN, which has been observed to readily oxidize in steam and simulated pressurized water reactor conditions. Thus, it is important to examine methods for waterproofing UN, especially for potential cladding breach scenarios. This can be achieved by controlling the microstructure so as to prevent contact between the UN fuel and coolant. Research so far this FY has focused on screening potential candidate additive materials to control UN microstructure using steam oxidation TGA. From these candidates, yttrium was selected based on corrosion resistance, which led to attempts to develop a method for liquid phase sintering of yttrium with UN. Yttrium in the form of yttrium dihydride (YH 2 ) was mixed with UN, pressed, and heated to temperatures above the melting point of Y metal to dehydride the material and then melt it to enable liquid phase sintering. Results showed no indication of densification, but did show chemical interaction between Y and UN, resulting in the formation of yttrium nitride (YN) and uranium metal. These observations were used to develop a better understanding of microstructure control for UN waterproofing to be addressed in an L2 milestone that is an FY19 deliverable (M2FT-19LA020201021).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

Synthesis and electrochemical performance of Li{sub 1+x}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} (0 {<=} x {<=} 0.15) cathode materials for lithium-ion batteries

Graphical abstract: Cycle behavior of Li{sub 1+x}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} cells (x = 0, 0.05, 0.10 and 0.15) obtained during cycling within the potential of 2.5-4.3 V. Highlights: Black-Right-Pointing-Pointer The spherical Li{sub 1+x}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} were synthesized by coprecipitation method. Black-Right-Pointing-Pointer Excess lithium improved the electrochemical performance. Black-Right-Pointing-Pointer Li{sub 1.10}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} showed the best electrochemical performance. Black-Right-Pointing-Pointer Li{sub 1.10}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} had the lowest charge transfer resistance. -- Abstract: In this work, layered lithium-excess materials Li{sub 1+x}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} (x = 0, 0.05, 0.10 and 0.15), of spherical morphology with primary nanoparticles assembled in secondary microspheres, were synthesized by a coprecipitation method. The effects of lithium content on the structure and electrochemical performance of these materials were evaluated by employing X-ray diffraction (XRD), inductive coupled plasma (ICP), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and galvanostatic charge/discharge tests. It is found that Li{sub 1.10}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}}, i.e., Li[(Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}){sub 0.95}Li{sub 0.05}]O{sub 2} showed the best electrochemical performance due to the highly ordered layered structure, reduced cation mixing and the lowest charge transfer resistance. Li{sub 1.10}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} delivered a discharge capacity of 145 mA h g{sup -1} at 125 mA g{sup -1} in the cut-off voltage of 2.5-4.3 V, and had a capacity retention of 100% after 50 cycles at room temperature.

36 MATERIALS SCIENCE↗

Experimental validation of a kilovoltage x-ray source model for computing imaging dose

Purpose: To introduce and validate a kilovoltage (kV) x-ray source model and characterization method to compute absorbed dose accrued from kV x-rays. Methods: The authors propose a simplified virtual point source model and characterization method for a kV x-ray source. The source is modeled by: (1) characterizing the spatial spectral and fluence distributions of the photons at a plane at the isocenter, and (2) creating a virtual point source from which photons are generated to yield the derived spatial spectral and fluence distribution at isocenter of an imaging system. The spatial photon distribution is determined by in-air relative dose measurements along the transverse (x) and radial (y) directions. The spectrum is characterized using transverse axis half-value layer measurements and the nominal peak potential (kVp). This source modeling approach is used to characterize a Varian{sup ®} on-board-imager (OBI{sup ®}) for four default cone-beam CT beam qualities: beams using a half bowtie filter (HBT) with 110 and 125 kVp, and a full bowtie filter (FBT) with 100 and 125 kVp. The source model and characterization method was validated by comparing dose computed by the authors’ inhouse software (kVDoseCalc) to relative dose measurements in a homogeneous and a heterogeneous block phantom comprised of tissue, bone, and lung-equivalent materials. Results: The characterized beam qualities and spatial photon distributions are comparable to reported values in the literature. Agreement between computed and measured percent depth-dose curves is ⩽2% in the homogeneous block phantom and ⩽2.5% in the heterogeneous block phantom. Transverse axis profiles taken at depths of 2 and 6 cm in the homogeneous block phantom show an agreement within 4%. All transverse axis dose profiles in water, in bone, and lung-equivalent materials for beams using a HBT, have an agreement within 5%. Measured profiles of FBT beams in bone and lung-equivalent materials were higher than their computed counterparts resulting in an agreement within 2.5%, 5%, and 8% within solid water, bone, and lung, respectively. Conclusions: The proposed virtual point source model and characterization method can be used to compute absorbed dose in both the homogeneous and heterogeneous block phantoms within of 2%–8% of measured values, depending on the phantom and the beam quality. The authors’ results also provide experimental validation for their kV dose computation software, kVDoseCalc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of High-Dose-Rate {sup 192}Ir Source Activity on Late Rectal Bleeding After Intracavitary Radiation Therapy for Uterine Cervix Cancer

Purpose: This retrospective study analyzed the effect of the activity of high-dose-rate (HDR) {sup 192}Ir source on late rectal bleeding after HDR intracavitary radiotherapy (ICRT) in patients with uterine cervix cancer. Methods and Materials: One hundred thirty-two patients who underwent HDR-ICRT and external beam radiotherapy (EBRT) were analyzed. The rectal point dose in ICRT was calculated by inserting a lead wire into the rectal lumen and summed with the whole-pelvic EBRT dose. The rectal biologic effective dose (BED) was calculated. The relationship between averaged source activity or the BED and late rectal bleeding were analyzed. Results: Three-year actuarial rectal bleeding probabilities were 46% ({>=}100 Gy{sub 3}) and 18% ({<=} 100 Gy{sub 3}), respectively (p < 0.005). When patients were divided into four groups according to rectal BED ({>=} or {<=}100 Gy{sub 3}) and source activity ({>=} or {<=}2.4 cGy.m{sup 2}.h{sup -1}), the group with both a high BED and high activity showed significantly greater probability (58% at 3 years; p < 0.005). It was noted that the probability of the group with BED of 100 Gy{sub 3} or greater was high, but that was not the case with 2.4 cGy.m{sup 2}.h{sup -1} or less. Conclusion: This is the first clinical report concerning the source activity effect of HDR {sup 192}Ir on late rectal bleeding in patients undergoing HDR-ICRT. This suggests that when source activity is higher than 2.4 cGy.m{sup 2}.h{sup -1}, ICRT should be performed with more caution not to exceed 100 Gy{sub 3} in total.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Role of Pre–Radiation Therapy {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography for Primary Mediastinal B-Cell Lymphomas Treated with R-CHOP or R-CHOP-Like Chemotherapy Plus Radiation

Purpose: To validate, in a monoinstitutional cohort with extended follow-up, that post–rituximab chemotherapy (R-CT) {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}FDG-PET) is a prognostic factor allowing discrimination of primary mediastinal B-cell lymphoma (PMBCL) patients at higher risk for progression after radiation therapy. Methods and Materials: We analyzed 51 patients, and {sup 18}FDG-PET scans were re-examined evaluating both the Deauville 5-point scale (D5PS) score and the standardized uptake value (SUV) of residual activity, if present. These parameters were then tested by univariate analysis for a potential correlation with progression-free survival (PFS) as the primary study endpoint. Results: Median follow-up time was 51 months (range, 9-153 months). After R-CT, D5PS score was 1 in 10 (19.6%), 2 in 11 (21.6%), 3 in 7 (13.8%), 4 in 17 (33.3%), and 5 in 6 patients (11.7%). Forty-three out of 51 patients (84.3%) had an SUV{sub max} ≤5, and 8 out of 51 (15.7%) had an SUV{sub max} ≥5. Overall, 6 patients experienced progression or relapse: 1 had a D5PS score 2 (with SUV{sub max} ≤5), and 5 had a D5PS score 5 (and SUV{sub max} ≥5). Patients with a D5PS score 5 showed significantly lower PFS rates versus all other scores (log-rank P<.001), as did patients with SUV{sub max} ≥5 when compared with those with SUV{sub max} ≤5 (log-rank P<.001). Conclusions: The present study confirmed the prognostic role of {sup 18}FDG-PET after R-CT, with patients with a D5PS score of 5 and/or an SUV{sub max} ≥5 being at high risk of progression/relapse after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Agreement Between Institutional Measurements and Treatment Planning System Calculations for Basic Dosimetric Parameters as Measured by the Imaging and Radiation Oncology Core-Houston

Purpose: To compare radiation machine measurement data collected by the Imaging and Radiation Oncology Core at Houston (IROC-H) with institutional treatment planning system (TPS) values, to identify parameters with large differences in agreement; the findings will help institutions focus their efforts to improve the accuracy of their TPS models. Methods and Materials: Between 2000 and 2014, IROC-H visited more than 250 institutions and conducted independent measurements of machine dosimetric data points, including percentage depth dose, output factors, off-axis factors, multileaf collimator small fields, and wedge data. We compared these data with the institutional TPS values for the same points by energy, class, and parameter to identify differences and similarities using criteria involving both the medians and standard deviations for Varian linear accelerators. Distributions of differences between machine measurements and institutional TPS values were generated for basic dosimetric parameters. Results: On average, intensity modulated radiation therapy–style and stereotactic body radiation therapy–style output factors and upper physical wedge output factors were the most problematic. Percentage depth dose, jaw output factors, and enhanced dynamic wedge output factors agreed best between the IROC-H measurements and the TPS values. Although small differences were shown between 2 common TPS systems, neither was superior to the other. Parameter agreement was constant over time from 2000 to 2014. Conclusions: Differences in basic dosimetric parameters between machine measurements and TPS values vary widely depending on the parameter, although agreement does not seem to vary by TPS and has not changed over time. Intensity modulated radiation therapy–style output factors, stereotactic body radiation therapy–style output factors, and upper physical wedge output factors had the largest disagreement and should be carefully modeled to ensure accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Room temperature mechanosynthesis of the La{sub 1-x}Sr{sub x}MnO{sub 3{+-}{delta}} (0{<=}x{<=}1) system and microstructural study

Monophase nanocrystalline powders belonging to the La{sub 1-x}Sr{sub x}MnO{sub 3{+-}{delta}} system (0{<=}x{<=}1) with a perovskite structure have been obtained by mechanochemistry synthesis using a planetary ball milling equipment from La{sub 2}O{sub 3}, SrO, and Mn{sub 2}O{sub 3} mixtures. The solid state reaction was complete after one hour of milling treatment. For all the compositional range, the diffraction domain was very small and the structure appeared as a pseudo cubic perovskite. After annealing at 1100 Degree-Sign C under static air, the symmetry evolution due to the La substitution by Sr was analyzed by X-ray and electron diffraction. Samples with x=0, 0.25, 0.5, and 0.75 were assigned to R-3c space group (1 6 7) in the rhombohedral system and perovskite structure. However, the symmetry of the last term of the system (x=1), SrMnO{sub 3{+-}{delta}} sample, changed to P6{sub 3}/mmc space group (1 9 4) in the hexagonal system. The terms with x=0.8, 0.85, and 0.9 presented mainly rhombohedral symmetry. - Graphical abstract: SEM micrographs corresponding to milled (M) and Heated (H) samples: LaMnO{sub 3{+-}{delta}}(M1 and H1) La{sub 0.75}Sr{sub 0.25}MnO{sub 3{+-}{delta}}(M2 and H2,) and SrMnO{sub 3{+-}{delta}}(M8 and H8). Highlights: Black-Right-Pointing-Pointer Synthesis of La{sub 1-x}Sr{sub x}MnO{sub 3{+-}{delta}} by mechanochemistry, a very simple and scalable method. Black-Right-Pointing-Pointer System with rhombohedral perovskite structure forming a solid solution till x=0.9. Black-Right-Pointing-Pointer Powder material with nanometer character that reduces the sinterization temperature. Black-Right-Pointing-Pointer Appropriate Microstructure for cathode electrodes to built SOFCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailoring characteristic thermal stability of Ni-Au binary nanocrystals via structure and composition engineering: theoretical insights into structural evolution and atomic inter-diffusion

We report on the structural evolution and atomic inter-diffusion characteristics of the bimetallic Ni-Au nanocrystals (NCs) by molecular dynamics simulations studies. Our results reveal that the thermal stability dynamics of Ni-Au NCs strongly depends on the atomic configurations. By engineering the structural construction with Ni:Au = 1:1 atomic composition, compared with core-shell Au@Ni and alloy NCs, the melting point of core-shell Ni@Au NCs is significantly enhanced up to 1215 K. Unexpectedly, with atomic ratio of Au:Ni= 1:9, the melting process initiates from the atoms in the shell of Ni@Au and alloy NCs, while starts from the core of Au@Ni NCs. The corresponding features and evolution process of structural motifs, mixing and segregation are illustrated via a series of dynamic simulations videos. Moreover, our results revealed that the face centered cubic phase Au{sub 0.75}Ni{sub 0.25} favorably stabilizes in NCs form but does not exist in the bulk counterpart, which elucidates the anomalies of previously reported experimental results on such bimetallic NCs.

36 MATERIALS SCIENCE↗

Unsupervised learning of ferroic variants from atomically resolved STEM images

An approach for the analysis of atomically resolved scanning transmission electron microscopy data with multiple ferroic variants in the presence of imaging non-idealities and chemical variabilities based on a rotationally invariant variational autoencoder (rVAE) is presented. We show that an optimal local descriptor for the analysis is a sub-image centered at specific atomic units, since materials and microscope distortions preclude the use of an ideal lattice as a reference point. The applicability of unsupervised clustering and dimensionality reduction methods is explored and is shown to produce clusters dominated by chemical and microscope effects, with a large number of classes required to establish the presence of rotational variants. Comparatively, the rVAE allows extraction of the angle corresponding to the orientation of ferroic variants explicitly, enabling straightforward identification of the ferroic variants as regions with constant or smoothly changing latent variables and sharp orientational changes. This approach allows further exploration of the chemical variability by separating the rotational degrees of freedom via rVAE and searching for remaining variability in the system. The code used in this article is available at https://github.com/saimani5/ferroelectric_domains_rVAE.

30 DIRECT ENERGY CONVERSION↗

Growth of ZnGeP{sub 2} crystals from melt

Some features of the growth of ZnGeP{sub 2} single crystals by the Bridgman method have been considered. The ratio of the thermal-conductivity coefficients of the liquid and solid phases of ZnGeP{sub 2} at the melting temperature was estimated to be 2.3. It is established that, in the case of ZnGeP{sub 2} growth on a seed, the most favorable crystallographic directions are <100> and <001>. It is shown that annealing and electron irradiation significantly decrease the optical absorption coefficient in the impurity absorption region.

36 MATERIALS SCIENCE↗

Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal imaging routines including different standard MRI sequences.

60 APPLIED LIFE SCIENCES↗

Feasibility of a Multigroup Deterministic Solution Method for Three-Dimensional Radiotherapy Dose Calculations

Purpose: To investigate the potential of a novel deterministic solver, Attila, for external photon beam radiotherapy dose calculations. Methods and Materials: Two hypothetical cases for prostate and head-and-neck cancer photon beam treatment plans were calculated using Attila and EGSnrc Monte Carlo simulations. Open beams were modeled as isotropic photon point sources collimated to specified field sizes. The sources had a realistic energy spectrum calculated by Monte Carlo for a Varian Clinac 2100 operated in a 6-MV photon mode. The Attila computational grids consisted of 106,000 elements, or 424,000 spatial degrees of freedom, for the prostate case, and 123,000 tetrahedral elements, or 492,000 spatial degrees of freedom, for the head-and-neck cases. Results: For both cases, results demonstrate excellent agreement between Attila and EGSnrc in all areas, including the build-up regions, near heterogeneities, and at the beam penumbra. Dose agreement for 99% of the voxels was within the 3% (relative point-wise difference) or 3-mm distance-to-agreement criterion. Localized differences between the Attila and EGSnrc results were observed at bone and soft-tissue interfaces and are attributable to the effect of voxel material homogenization in calculating dose-to-medium in EGSnrc. For both cases, Attila calculation times were <20 central processing unit minutes on a single 2.2-GHz AMD Opteron processor. Conclusions: The methods in Attila have the potential to be the basis for an efficient dose engine for patient-specific treatment planning, providing accuracy similar to that obtained by Monte Carlo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operando methods: A new era of electrochemistry

One of the grand challenges facing electrochemistry is to directly resolve the complex nature of (electro)catalyst active sites and capture real-time “movies” of reaction dynamics, i.e. “watching chemistry in action”. The need for such fundamental understanding has stimulated the development of operando/in situ methods, which have greatly enhanced our ability to identify activity descriptors of electrocatalysts and establish structure–property relationships of energy materials. Here, this review summarizes the frontiers of operando electrochemical liquid-cell scanning transmission electron microscopy and correlative synchrotron X-ray methods, which are complementary tools to comprehensively investigate reaction dynamics across multiple spatiotemporal scales. In an effort to encourage greater adoption of advanced operando methods by the general electrochemistry community, this review points out the need to benchmark electrochemistry in confined and heterogenous liquid environment with minimal beam-induced damage. We anticipate that multimodal operando methods will become indispensable for understanding interfacial reaction mechanisms for the broad chemistry and energy materials communities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗