Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Lawrence Livermore National Laboratory?s Book of Minimum Detectable Activity for Direct Measurement of Internally Deposited Radionuclides in Radiation Workers

Lawrence Livermore National Laboratory maintains an in vivo measurement program designed to identify and evaluate the activity of radionuclides deposited in the body. Two types of systems are primarily used for the routine monitoring of radiation workers, the lung counting system and the scanning bed whole body counting system. The lung counting system is comprised of two Canberra ACTII detector sets. Each ACTII set contains two planar germanium detectors with carbon composite end windows optimized to measure low energy photon emitting radionuclides. The ACTII detectors are placed on the upper torso over the lungs for the direct measurement of internally deposited radionuclides in the lungs that emit low energy photons. A correction for the thickness of the chest wall is applied to the efficiency. Because the thickness of the chest wall is a key factor in the measurement of low energy photon emitting radionuclides in the lung, the minimum detectable activity is a function of the chest wall thickness. The scanning bed whole body counting system is comprised of a thin air mattress on top of a carbon fiber bed that slowly scans over four high purity germanium detectors. The scanning system is designed to minimize variations in detected activity due to radionuclide distribution in the body. The scanning bed detection system is typically used for the measurement of internally deposited radionuclides that emit photons above 100 to 200 keV. MDAs have been generated for radionuclides that provide energies above 80 keV since the lowest calibration energy for the system is approximately 86 keV. The following charts and table provide best determination of minimum detectable activity using human subjects as controls for the background contributions. A wide variety of radionuclides are used throughout the laboratory and the following pages represent several of the radionuclides that have been encountered at the Whole Body and Spectroscopy Laboratories within Hazards Control.

61 RADIATION PROTECTION AND DOSIMETRY↗

A strained silicon cold electron bolometer using Schottky contacts

We describe optical characterisation of a strained silicon cold electron bolometer (CEB), operating on a 350 mK stage, designed for absorption of millimetre-wave radiation. The silicon cold electron bolometer utilises Schottky contacts between a superconductor and an n{sup ++} doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to 160 GHz and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of 50% for radiation coupled into the device by the planar antenna and an overall noise equivalent power, referred to absorbed optical power, of 1.1×10{sup −16} W Hz{sup −1/2} when the detector is observing a 300 K source through a 4 K throughput limiting aperture. Even though this optical system is not optimized, we measure a system noise equivalent temperature difference of 6 mK Hz{sup −1/2}. We measure the noise of the device using a cross-correlation of time stream data, measured simultaneously with two junction field-effect transistor amplifiers, with a base correlated noise level of 300 pV Hz{sup −1/2} and find that the total noise is consistent with a combination of photon noise, current shot noise, and electron-phonon thermal noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coastal High-resolution Observations and Remote Sensing of Ecosystems (C-HORSE)

Coastal benthic marine ecosystems, such as coral reefs, seagrass beds, and kelp forests are highly productive as well as ecologically and commercially important resources. These systems are vulnerable to degraded water quality due to coastal development, terrestrial run-off, and harmful algal blooms. Measurements of these features are important for understanding linkages with land-based sources of pollution and impacts to coastal ecosystems. Challenges for accurate remote sensing of coastal benthic (shallow water) ecosystems and water quality are complicated by atmospheric scattering/absorption (approximately 80+% of the signal), sun glint from the sea surface, and water column scattering (e.g., turbidity). Further, sensor challenges related to signal to noise (SNR) over optically dark targets as well as insufficient radiometric calibration thwart the value of coastal remotely-sensed data. Atmospheric correction of satellite and airborne remotely-sensed radiance data is crucial for deriving accurate water-leaving radiance in coastal waters. C-HORSE seeks to optimize coastal remote sensing measurements by using a novel airborne instrument suite that will bridge calibration, validation, and research capabilities of bio-optical measurements from the sea to the high altitude remote sensing platform. The primary goal of C-HORSE is to facilitate enhanced optical observations of coastal ecosystems using state of the art portable microradiometers with 19 targeted spectral channels and flight planning to optimize measurements further supporting current and future remote sensing missions.

Coasts↗

Optimization techniques applied to passive measures for in-orbit spacecraft survivability

Spacecraft designers have always been concerned about the effects of meteoroid impacts on mission safety. The engineering solution to this problem has generally been to erect a bumper or shield placed outboard from the spacecraft wall to disrupt/deflect the incoming projectiles. Spacecraft designers have a number of tools at their disposal to aid in the design process. These include hypervelocity impact testing, analytic impact predictors, and hydrodynamic codes. Analytic impact predictors generally provide the best quick-look estimate of design tradeoffs. The most complete way to determine the characteristics of an analytic impact predictor is through optimization of the protective structures design problem formulated with the predictor of interest. Space Station Freedom protective structures design insight is provided through the coupling of design/material requirements, hypervelocity impact phenomenology, meteoroid and space debris environment sensitivities, optimization techniques and operations research strategies, and mission scenarios. Major results are presented.

Mog, Robert A.↗

Measurements of charge state breeding efficiency at BNL test EBIS

Charge breeding of singly charged ions is required to efficiently accelerate rare isotope ion beams for nuclear and astrophysics experiments, and to enhance the accuracy of low-energy Penning trap-assisted spectroscopy. An efficient charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) to the ANL Tandem Linear Accelerator System (ATLAS) facility is being developed using the BNL Test Electron Beam Ion Source (Test EBIS) as a prototype. Parameters of the CARIBU EBIS charge breeder are similar to those of the BNL Test EBIS except the electron beam current will be adjustable in the range from 1 to 2 {angstrom}. The electron beam current density in the CARIBU EBIS trap will be significantly higher than in existing operational charge state breeders based on the EBIS concept. The charge state breeding efficiency is expected to be about 25% for the isotope ions extracted from the CARIBU. For the success of our EBIS project, it is essential to demonstrate high breeding efficiency at the BNL Test EBIS tuned to the regime close to the parameters of the CARIBU EBIS at ANL. The breeding efficiency optimization and measurements have been successfully carried out using a Cs{sup +} surface ionization ion source for externally pulsed injection into the BNL Test EBIS. A Cs{sup +} ion beam with a total number of ions of 5 x 10{sup 8} and optimized pulse length of 70 {mu}s has been injected into the Test EBIS and charge-bred for 5.3 ms for two different electron beam currents 1 and 1.5 {angstrom}. In these experiments we have achieved 70% injection/extraction efficiency and breeding efficiency into the most abundant charge state 17%.

43 PARTICLE ACCELERATORS↗

Compact Cloud Condensation Nucleus Counter for Unmanned Aerial Systems (UAS) and Long-Term Monitoring Applications (Final Report)

Brechtel Manufacturing Incorporated (BMI) is developing a compact, modular suite of new aerosol measurement technologies optimized for use on Unmanned Aerial Vehicles (UAVs) and other applications where space, weight, power and cost are significant barriers to deployment. The project is focused on a cloud condensation nucleus counter that exposes sampled particles to a simulated cloud environment and counts how many of the particles grow to micron-sized droplets. The new development helps address the need for reduced uncertainties in climate model sensitivities to ambient aerosol properties by promoting the capability to perform aerosol measurements more often, in more locations, and at reduced cost. Applications of the new technology include long-term measurements of the aerosol effects on cloud radiation, microphysical and precipitation processes, weather prediction and modelling studies, and weather modification studies.

47 OTHER INSTRUMENTATION↗

Observation of cyclotron resonance and measurement of the hole mass in optimally doped La 2–x Sr x CuO 4

Using time-domain terahertz spectroscopy in pulsed magnetic fields up to 31 T, we measure the terahertz optical conductivity in an optimally doped thin film of the high-temperature superconducting cuprate La 1.84 Sr 0.16 CuO 4 . We observe systematic changes in the circularly polarized complex optical conductivity that are consistent with cyclotron absorption of p-type charge carriers characterized by a cyclotron mass of 4.9m e ± 0.8m e and a scattering rate that increases with magnetic field. Furthermore, these results open the door to studies aimed at characterizing the degree to which electron-electron interactions influence carrier masses in cuprate superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3deg field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev-Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

Telescope↗

Detection of chlorine with concentration of 0.18 kg/m{sup 3} in concrete by laser-induced breakdown spectroscopy

The chlorine concentration in concrete samples was measured by laser-induced breakdown spectroscopy (LIBS). One or two pulsed second harmonic Nd:YAG lasers ({lambda}=532 nm) were used for the generation of laser-induced breakdown, and an intensified CCD camera, spectrometer, and optical bundle fiber were used for spectral measurement. To maximize the spectral intensity of the chlorine fluorescence line at a wavelength of 837.59 nm, the time delay between laser irradiation and spectral measurement, the time delay between the two laser pulses in double-pulse measurement, and the gate width of the spectral measurement were optimized. The linear relationship between the spectral intensity of the chlorine fluorescence line and the chlorine concentration was verified for pressed samples with chlorine concentrations from 0.18 to 5.4 kg/m{sup 3}. The signal-to-noise ratio was higher than 2 for the sample with a chlorine concentration of 0.18 kg/m{sup 3} (0.008 wt. %). Thus, a chlorine concentration of 0.6 kg/m{sup 3}, at which the reinforcing bars in concrete structures start to corrode, can be detected. These results show that LIBS is effective for the quantitative measurement of chlorine concentration in concrete with high sensitivity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimizing galaxy samples for clustering measurements in photometric surveys

When analysing galaxy clustering in multiband imaging surveys, there is a trade-off between selecting the largest galaxy samples (to minimize the shot noise) and selecting samples with the best photometric redshift (photo-$z$) precision, which generally includes only a small subset of galaxies. In this paper, we systematically explore this trade-off. Our analysis is targeted towards the third-year data of the Dark Energy Survey (DES), but our methods hold generally for other data sets. Using a simple Gaussian model for the redshift uncertainties, we carry out a Fisher matrix forecast for cosmological constraints from angular clustering in the redshift range $z$ = 0.2–0.95. We quantify the cosmological constraints using a figure of merit (FoM) that measures the combined constraints on $Ωm$ and $σ_8$ in the context of Λ cold dark matter ($Λ$CDM) cosmology. We find that the trade-off between sample size and photo-z precision is sensitive to (1) whether cross-correlations between redshift bins are included or not, and (2) the ratio of the redshift bin width $δz$ to the photo-$z$ precision $σ_z$. When cross-correlations are included and the redshift bin width is allowed to vary, the highest FoM is achieved when $δz$ ~ $σ_z$. We find that for the typical case of 5-10 redshift bins, optimal results are reached when we use larger, less precise photo-z samples, provided that we include cross-correlations. For samples with higher $σ_z$, the overlap between redshift bins is larger, leading to higher cross-correlation amplitudes. This leads to the self-calibration of the photo-z parameters and therefore tighter cosmological constraints. These results can be used to help guide galaxy sample selection for clustering analysis in ongoing and future photometric surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

A Comparison of CdS and Zn(O,S) Buffer Layers in (Ag,Cu)(In,Ga)Se2 Solar Cells

Cu(In,Ga)Se 2 -based solar cells typically use a C dS buffer layer, even though its relatively low bandgap causes parasitic absorption. While alternatives to CdS have been explored in other studies, limited results have been shown for Ag-alloyed CIGS (ACIGS). In this study, ACIGS solar cells with both CdS and Zn(O,S) buffer layers were fabricated and compared for solar cell performance. The Zn(O,S) buffer slightly improved J sc through reduced absorption, although surface optimization is necessary. The Zn(O,S) ACIGS also had improved FF through reduced series resistance and ideality factor, which could be improved further through optimization. However, the Voc in the Zn(O,S) samples was reduced, likely due to increased bulk and front interface recombination. This study shows the promise of Zn(O,S) as a buffer layer in ACIGS solar cells and suggests pathways for further improvement.

absorption↗

Technical note: Optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method

Purpose: This article describes the spectral optimization of dual-energy computed tomography using balanced filters (bf-DECT) to reduce the tube loadings and dose by dedicating to the acquisition of electron density information, which is essential for treatment planning in radiotherapy. Methods: For the spectral optimization of bf-DECT, the author calculated the beam-hardening error and air kerma required to achieve a desired noise level in an electron density image of a 50-cm-diameter cylindrical water phantom. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. Results: The optimal combination of tube voltages was 80 kV/140 kV in conjunction with Tb/Hf and Bi/Mo filter pairs; this combination agrees with that obtained in a previous study [M. Saito, ''Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method,'' Med. Phys. 36, 3631-3642 (2009)], although the thicknesses of the filters that yielded a minimum tube output were slightly different from those obtained in the previous study. The resultant tube loading of a low-energy scan of the present bf-DECT significantly decreased from 57.5 to 4.5 times that of a high-energy scan for conventional DECT. Furthermore, the air kerma of bf-DECT could be reduced to less than that of conventional DECT, while obtaining the same figure of merit for the measurement of electron density and effective atomic number. Conclusions: The tube-loading and dose efficiencies of bf-DECT were considerably improved by sacrificing the quality of the noise level in the images of effective atomic number.

60 APPLIED LIFE SCIENCES↗

Beam Polarization at the ILC: the Physics Impact and the Accelerator Solutions

In this contribution accelerator solutions for polarized beams and their impact on physics measurements are discussed. Focus are physics requirements for precision polarimetry near the interaction point and their realization with polarized sources. Based on the ILC baseline programme as described in the Reference Design Report (RDR), recent developments are discussed and evaluated taking into account physics runs at beam energies between 100 GeV and 250 GeV, as well as calibration runs on the Z-pole and options as the 1TeV upgrade and GigaZ. The studies, talks and discussions presented at this conference demonstrated that beam polarization and its measurement are crucial for the physics success of any future linear collider. To achieve the required precision it is absolutely decisive to employ multiple devices for testing and controlling the systematic uncertainties of each polarimeter. The polarimetry methods for the ILC are complementary: with the upstream polarimeter the measurements are performed in a clean environment, they are fast and allow to monitor time-dependent variations of polarization. The polarimeter downstream the IP will measure the disrupted beam resulting in high background and much lower statistics, but it allows access to the depolarization at the IP. Cross checks between the polarimeter results give redundancy and inter-calibration which is essential for high precision measurements. Current plans and issues for polarimeters and also energy spectrometers in the Beam Delivery System of the ILC are summarized in reference [28]. The ILC baseline design allows already from the beginning the operation with polarized electrons and polarized positrons provided the spin rotation and the fast helicity reversal for positrons will be implemented. A reversal of the positron helicity significantly slower than that of electrons is not recommended to not compromise the precision and hence the success of the ILC. Recently to use calibration data at the Z resonance for physics has been discussed. It looks promising but further studies are needed to evaluate and to optimize these measurements. Finally it should be remarked: many studies on different physics processes and scenarios at a future linear collider are done for high luminosities and high energy assuming small and well-known uncertainties. Polarization, especially positron polarization, is often considered as not that important. But in order to interpret data and to reduce ambiguities in the measurements, the polarization of electrons and positrons and their very precise knowledge are essential. The ILC design must offer this from the beginning to be prepared for the physics questions after years of LHC operation.

43 PARTICLE ACCELERATORS↗

Preliminary Work for Examining the Scalability of Reinforcement Learning

Researchers began studying automated agents that learn to perform multiple-step tasks early in the history of artificial intelligence (Samuel, 1963; Samuel, 1967; Waterman, 1970; Fikes, Hart & Nilsonn, 1972). Multiple-step tasks are tasks that can only be solved via a sequence of decisions, such as control problems, robotics problems, classic problem-solving, and game-playing. The objective of agents attempting to learn such tasks is to use the resources they have available in order to become more proficient at the tasks. In particular, each agent attempts to develop a good policy, a mapping from states to actions, that allows it to select actions that optimize a measure of its performance on the task; for example, reducing the number of steps necessary to complete the task successfully. Our study focuses on reinforcement learning, a set of learning techniques where the learner performs trial-and-error experiments in the task and adapts its policy based on the outcome of those experiments. Much of the work in reinforcement learning has focused on a particular, simple representation, where every problem state is represented explicitly in a table, and associated with each state are the actions that can be chosen in that state. A major advantage of this table lookup representation is that one can prove that certain reinforcement learning techniques will develop an optimal policy for the current task. The drawback is that the representation limits the application of reinforcement learning to multiple-step tasks with relatively small state-spaces. There has been a little theoretical work that proves that convergence to optimal solutions can be obtained when using generalization structures, but the structures are quite simple. The theory says little about complex structures, such as multi-layer, feedforward artificial neural networks (Rumelhart & McClelland, 1986), but empirical results indicate that the use of reinforcement learning with such structures is promising. These empirical results make no theoretical claims, nor compare the policies produced to optimal policies. A goal of our work is to be able to make the comparison between an optimal policy and one stored in an artificial neural network. A difficulty of performing such a study is finding a multiple-step task that is small enough that one can find an optimal policy using table lookup, yet large enough that, for practical purposes, an artificial neural network is really required. We have identified a limited form of the game OTHELLO as satisfying these requirements. The work we report here is in the very preliminary stages of research, but this paper provides background for the problem being studied and a description of our initial approach to examining the problem. In the remainder of this paper, we first describe reinforcement learning in more detail. Next, we present the game OTHELLO. Finally we argue that a restricted form of the game meets the requirements of our study, and describe our preliminary approach to finding an optimal solution to the problem.

Clouse, Jeff↗

Fabrication of optical multilayer for two-color phase plate in super-resolution microscope

In super-resolution microscopy based on fluorescence depletion, the two-color phase plate (TPP) is an indispensable optical element, which can independently control the phase shifts for two beams of different color, i.e., the pump and erase beams. By controlling a phase shift of the erase beam through the TPP, the erase beam can be modulated into a doughnut shape, while the pump beam maintains the initial Gaussian shape. To obtain a reliable optical multiplayer (ML) for the TPP, we designed a ML with only two optical layers by performing numerical optimization. The measured phase shifts generated by the fabricated ML using interferometry correspond to the design values. The beam profiles in the focal plane are also consistent with theoretical results. Although the fabricated ML consists of only two optical layers, the ML can provide a suitable phase modulation function for the TPP in a practical super-resolution microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗