Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Alignment of Optical Backscatter Measurements from the EXPORTS Northeast Pacific Field Deployment

Backscattering of light is commonly measured by ocean observing systems, including ships and autonomous platforms, and is used as a proxy for the concentration of water column constituents such as phytoplankton and particulate carbon. Multiple on-going projects involve large numbers of independent measurements of backscatter, as well as other biologically relevant parameters, to understand how biology is changing in time and space throughout the global ocean. Rarely are there sufficient measurements to test how well these instruments are inter-calibrated in real-world deployment conditions. This paper develops a procedure to align multiple independently calibrated backscatter instruments to each other using nearby profiling casts and applies this method to nine instruments deployed during a recent field campaign in the North Pacific during August–September of 2018. This process revealed several incorrect calibrations; post-alignment, all nine instruments aligned extremely well with each other. We also tested an alignment to a deep-water reference and found that this method is generally sufficient but has significant limitations; this procedure lacks the ability to correct instruments measuring only shallow profiles and can only account for additive offsets, not multiplicative changes. These findings highlight the utility of process studies involving several independent measurements of similar parameters in the same area.

North Pacific↗

Integrated Decision Methodology for Final Disposal of Radioactive Sources

Radioactive sources are used throughout the world, and their beneficial uses are many. Sources are at the core of many applications in different branches of industry, medicine, agriculture and research. Sources are present in a very wide range of equipment that is used for, inter alia, cancer treatment, killing bacteria in food, sterilizing medical supplies, measuring instruments such as gauges used to measure soil moisture and soil density and many other components, irradiating seeds for enhancing food production, protecting buildings from lightning strikes, mapping underground sources of water, prospecting for oil and gas reserves, measuring density of soil for construction projects, or even detecting smoke. At their “cradle” and when in use, radioactive sources are usually properly managed and controlled. It is when a source has reached the end of its useful life when they are at a higher risk of being under inadequate control, poorly managed, or even becoming orphan. Sources that have reached the end of their useful life must be carefully and safely managed. The “grave” of disused sources needs a proper disposal process to prevent them from posing a potential threat to people or the environment. To protect the public and the environment from the potential hazards of ionizing radiation, and to prevent disused sources from becoming orphan, a “cradle-to-grave” control of radioactive sources is essential, as promoted by the Code of Conduct on the Safety and Security of Radioactive Sources. This approach requires a national policy and strategy, an adequate legal and regulatory framework, and adequate resources and infrastructure. Many IAEAMember States have expressed the need for effective solutions to this challenge. There is also a gap related to the life cycle costs of potential disposal practices. This paper proposes a multi-attribute decision making methodology to compare disposal options using both economic and non-economic criteria leading to a preferred option for disposal and a strategy for final disposal of disused radioactive sources that is specific and optimized for each IAEA Member State.

Beatty, Randy↗

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the performance by a slope measurement of a highly curved super-quality substrate with less than 0.3 microradian (rms)slope variation.

47 OTHER INSTRUMENTATION↗

Integration of the Two-Dimensional Power Spectral Density into Specifications for the X-ray Domain -- Problems and Opportunities

An implementation of the two-dimensional statistical scattering theory of Church and Takacs for the prediction of scattering from x-ray mirrors is presented with a graphical user interface. The process of this development has clarified several problems which are of significant interest to the synchrotron community. These problems have been addressed to some extent, for example, for large astronomical telescopes, and at the National Ignition Facility for normal incidence optics, but not in the synchrotron community for grazing incidence optics. Since it is based on the Power Spectral Density (PSD) to provide a description of the deviations from ideal shape of the surface, accurate prediction of the scattering requires an accurate estimation of the PSD. Specifically, the spatial frequency range of measurement must be the correct one for the geometry of use of the optic--including grazing incidence and coherence effects, and the modifications to the PSD of the Optical Transfer Functions (OTF) of the measuring instruments must be removed. A solution for removal of OTF effects has been presented previously, the Binary Pseudo-Random Grating. Typically, the frequency range of a single instrument does not cover the range of interest, requiring the stitching together of PSD estimations. This combination generates its own set of difficulties in two dimensions. Fitting smooth functions to two dimensional PSDs, particularly in the case of spatial non-isotropy of the surface, which is often the case for optics in synchrotron beam lines, can be difficult. The convenient, and physically accurate fractal for one dimension does not readily transfer to two dimensions. Finally, a completely statistical description of scattering must be integrated with a deterministic low spatial frequency component in order to completely model the intensity near the image. An outline for approaching these problems, and our proposed experimental program is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guide to measurement of winds with instrumented aircraft

Aircraft measurement techniques are reviewed. Review of past and present applications of instrument aircraft to atmospheric observations is presented. Questions to be answered relative to measuring mean wind profiles as contrasted to turbulence measurements are then addressed. Requirements of instrumentation and accuracy, data reduction, data acquisition, and theoretical and certainty analysis are considered.

Frost, Walter↗

Processing Methodology for Double Sensor Probe in a Bubbly Flow

Bubbly flow phenomenon is the most common flow pattern in nuclear plant system. In this paper, according to Hibiki and Bartel, the experiment was designed to observe the fluid conditions surrounding nuclear rod. In recent years, double sensor probe is one of the measuring techniques for the bubbly flow. It can measure local void fraction and bubble velocity. After mathematical statistical calculation, interfacial area concentration is obtained by Kataoka. The double sensor probe method, with the advantage for measuring local interfacial area concentration, has become widely used in many measurement methods. The paper of Liu and Zhao were referred to establish the post-processing for the raw data obtained from measuring instrument. After drawing the signal of the probe, it is important to analyze the raw data for the elimination of unnecessary noise signal and highlight the characteristic signal. Based on the same experimental condition, the different filtering methods, Simple Moving Average (SMA) and Gaussian average, were compared and discussed by the double sensor probe.

42 ENGINEERING↗

SSBUV and NOAA-11 SBUV/2 Solar Variability Measurements

The Shuttle SBUV (SSBUV) and NOAA-11 SBUV/2 instruments measured solar spectral UV irradiance during the maximum and declining phase of solar cycle 22. The SSB UV data accurately represent the absolute solar UV irradiance between 200-405 nm, and also show the long-term variations during eight flights between October 1989 and January 1996. These data have been used to correct long-term sensitivity changes in the NOAA-11 SBUV/2 data, which provide a near-daily record of solar UV variations over the 170-400 nm region between December 1988 and October 1994. The NOAA-11 data demonstrate the evolution of short-term solar UV activity during solar cycle 22.

DeLand, Matthew T.↗

Investigation of techniques for correcting ERTS data for solar and atmospheric effects

The author has identified the following significant results. The design and fabrication of five radiant power measuring instruments (RPMI) for ERTS ground truth have been completed. These instruments will be deployed in concert with ERTS overflights to obtain radiometric measurements needed to determine solar and atmospheric parameters that effect ERTS radiance measurements. With these parameters, the accuracy and capability of various procedures for transforming ERTS data into absolute target reflectance signatures will be evaluated. The RPMI is a rugged, hand-carried instrument accurately calibrated to measure both downwelling and reflected radiance within each ERTS multispectral scanner band. A foldover handle permits a quick change from wide angle global or sky irradiance measurements to narrow angle radiance measurements from sky and ground targets. These measurements yield ground truth site reflectance and permit calculation of additional parameters such as beam transmittance between spacecraft and ground, and path radiance (path reflectance).

Rogers, R. H.↗

Simultaneous Momentum and Position Measurement and the Instrumental Weyl-Heisenberg Group

The canonical commutation relation, [Q,P]=iℏ, stands at the foundation of quantum theory and the original Hilbert space. The interpretation of P and Q as observables has always relied on the analogies that exist between the unitary transformations of Hilbert space and the canonical (also known as contact) transformations of classical phase space. Now that the theory of quantum measurement is essentially complete (this took a while), it is possible to revisit the canonical commutation relation in a way that sets the foundation of quantum theory not on unitary transformations but on positive transformations. This paper shows how the concept of simultaneous measurement leads to a fundamental differential geometric problem whose solution shows us the following. The simultaneous P and Q measurement (SPQM) defines a universal measuring instrument, which takes the shape of a seven-dimensional manifold, a universal covering group we call the instrumental Weyl-Heisenberg (IWH) group. The group IWH connects the identity to classical phase space in unexpected ways that are significant enough that the positive-operator-valued measure (POVM) offers a complete alternative to energy quantization. Five of the dimensions define processes that can be easily recognized and understood. The other two dimensions, the normalization and phase in the center of the IWH group, are less familiar. The normalization, in particular, requires special handling in order to describe and understand the SPQM instrument.

47 OTHER INSTRUMENTATION↗

Quantum dynamics of a small symmetry breaking measurement device

Highlights: • Ferromagnetic measurement device exploits symmetry breaking to measure a spin. • Quantum interaction results in loss of phase coherence of test object. • Dynamics lead to sizeable correlation with, and enhancement of, microscopic object. • No reliable registration of pointer readings is observed after decoupling spin. - Abstract: A quantum measuring instrument is constructed that utilises symmetry breaking to enhance a microscopic signal. The entire quantum system consists of a system–apparatus–environment triad that is composed of a small set of spin-1/2 particles. The apparatus is a ferromagnet that measures the z-component of a single spin. A full quantum many-body calculation allows for a careful examination of the loss of phase coherence, the formation and amplification of system–apparatus correlations, the irreversibility of registration, the fault tolerance, and the bias of the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Validation of Simulations Using Full-field Measurement Techniques

The calibration by reference materials of dynamic full-field measurement systems is discussed together with their use to validate numerical simulations of structural mechanics. The discussion addresses three challenges that are faced in these processes, i.e. how to calibrate a measuring instrument that (i) provides full-field data, and (ii) is dynamic; (iii) how to compare data from simulation and experimentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of international Dobson spectrophotometer calibrations at Arosa, Switzerland, 1990

An international comparison of Dobson ozone spectrophotometers, organized and partially funded by the World Meteorological Organization (WMO), was held at the Lichtklimatisches Observatorium (LKO) in Arosa, Switzerland, July-August 1990. Countries participating with a total of 18 Dobson instruments were Belgium, Czechoslovakia, Denmark, Germany, Greece, Hungary, Iceland, Norway, Poland, Portugal, Rumania, Spain, Switzerland, the United Kingdom, the United States, and the United Soviet Socialist Republics. The reference standard instrument for the comparison was U.S.A. Secondary Standard Dobson Spectrophotometer 65 maintained by the NOAA Climate and Monitoring and Diagnostics Laboratory, Boulder, Colorado. The mean difference in ozone obtained with the Dobson instruments relative to Dobson instrument 65, calculated from ADDSGQP observations in the air mass range 1.15-3.2, was minus 1.0 plus or minus 1.2 (1 sigma) percent. The WMO Standard Brewer Spectrometer 39 also participated. In the mean, the Brewer instrument measured 0.6 plus or minus 0.2 (1 sigma) percent more ozone than did Dobson instrument 65. Results are presented, also, of ozone vertical profile measurements made with the Dobson instruments, two Brewer spectrometers, a LIDAR, a balloon ozonesonde flown from Hohenpeissenberg, Germany, and balloon ozonesondes flown from Payerne, Switzerland.

Grass, R. D.↗

Method to Calculate Uncertainty Estimate of Measuring Shortwave Solar Irradiance using Thermopile and Semiconductor Solar Radiometers

The uncertainty of measuring solar irradiance is fundamentally important for solar energy and atmospheric science applications. Without an uncertainty statement, the quality of a result, model, or testing method cannot be quantified, the chain of traceability is broken, and confidence cannot be maintained in the measurement. Measurement results are incomplete and meaningless without a statementof the estimated uncertainty with traceability to the International System of Units (SI) or to another internationally recognized standard. This report explains how to use International Guidelines of Uncertainty in Measurement (GUM) to calculate such uncertainty. The report also shows that without appropriate corrections to solar measuring instruments (solar radiometers), the uncertainty ofmeasuring shortwave solar irradiance can exceed 4% using present state-of-the-art pyranometers and 2.7% using present state-of-the-art pyrheliometers. Finally, the report demonstrates that by applying the appropriate corrections, uncertainties may be reduced by at least 50%. The uncertainties, with or without the appropriate corrections might not be compatible with the needs of solar energy andatmospheric science applications; yet, this report may shed some light on the sources of uncertainties and the means to reduce overall uncertainty in measuring solar irradiance.

14 SOLAR ENERGY↗

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗

Compressibility measurement of fluid-system ullage

Portable self-contained instrument measures volume of free gas or air trapped in closed fluid systems, such as lubricating-oil lines or hydraulic brakes. In response to measurement readings, operator may use device to accurately add or withdraw fluid to or from system.

Dzienis, D. A.↗

Enhanced Formation Flying for the Earth Observing-1 (EO-1) New Millennium Mission

With scientific objectives for Earth observation programs becoming more ambitious and spacecraft becoming more autonomous, the need for new technical approaches on the feasibility of achieving and maintaining formations of spacecraft has come to the forefront. The trend to develop small low cost spacecraft has led many scientists to recognize the advantage of flying several spacecraft in formation, an example of which is shown in the figure below, to achieve the correlated instrument measurements formerly possible only by flying many instruments on a single large platform. Yet, formation flying imposes additional complications on orbit maintenance, especially when each spacecraft has its own orbit requirements. However, advances in automation proposed by GSFC Codes 550 and 712 allow more of the burden in maneuver planning and execution to be placed onboard the spacecraft, mitigating some of the associated operational concerns. The purpose of this analysis is to develop the fundamentals of formation flying mechanics, concepts for understanding the relative motion of free flying spacecraft, and an operational control theory for formation maintenance of the Earth Observing-1 (EO-l) spacecraft that is part of the New Millennium. Results of this development can be used to determine the appropriateness of formation flying for a particular case as well as the operational impacts. Applications to the Mission to Planet Earth (MTPE) Earth Observing System (EOS) and New Millennium (NM) were highly considered in analysis and applications. This paper presents the proposed methods for the guidance and control of the EO-1 spacecraft to formation fly with the Landsat-7 spacecraft using an autonomous closed loop three axis navigation control, GPS, and Cross link navigation support. Simulation results using various fidelity levels of modeling, algorithms developed and implemented in MATLAB, and autonomous 'fuzzy logic' control using AutoCon will be presented. The results of these analysis on the ability to meet mission and formation flying requirements will be presented.

Folta, David↗

Design and implementation of satellite formations and constellations

The direction to develop small low cost spacecraft has led many scientists to recognize the advantage of flying spacecraft in constellations and formations to achieve the correlated instrument measurements formerly possible only by flying many instruments on a single large platform. Yet, constellations and formation flying impose additional complications on orbit selection and orbit maintenance, especially when each spacecraft has its own orbit or science requirements. The purpose of this paper is to develop an operational control method for maintenance of these missions. Examples will be taken from the Earth Observing-1 (EO-1) spacecraft that is part of the New Millennium Program (NMP) and from proposed Earth System Science Program Office (ESSPO) constellations. Results can be used to determine the appropriateness of constellations and formation flying for a particular case as well as the operational impacts. Applications to the ESSPO and NMP are highly considered in analysis and applications. After constellation and formation analysis is completed, implementation of a maneuver maintenance strategy becomes the driver. Advances in technology and automation by GSFC's Guidance, Navigation, and Control Center allow more of the burden of the orbit selection and maneuver maintenance to be automated and ultimately placed onboard the spacecraft, mitigating most of the associated operational concerns. This paper presents the GSFC closed-loop control method to fly in either constellations or formations through the use of an autonomous closed loop three-axis navigation control and innovative orbit maintenance support. Simulation results using AutoCon(TM) and FreeFlyer(TM) with various fidelity levels of modeling and algorithms are presented.

Folta, David↗

Design and Implementation of Satellite Formations and Constellations

The direction to develop small low cost spacecraft has led many scientists to recognize the advantage of flying spacecraft in constellations and formations to achieve the correlated instrument measurements formerly possible only by flying many instruments on a single large platform. Yet, constellations and formation flying impose additional complications on orbit selection and orbit maintenance, especially when each spacecraft has its own orbit or science requirements. The purpose of this paper is to develop an operational control method for maintenance of these missions. Examples will be taken from the Earth Observing-1 (EO-1) spacecraft that is part of the New Millennium Program (NMP) and from proposed Earth System Science Program Office (ESSPO) constellations. Results can be used to determine the appropriateness of constellations and formation flying for a particular case as well as the operational impacts. Applications to the ESSPO and NMP are highly considered in analysis and applications. After constellation and formation analysis is completed, implementation of a maneuver maintenance strategy becomes the driver. Advances in technology and automation by GSFC's Guidance, Navigation, and Control Center allow more of the burden of the orbit selection and maneuver maintenance to be automated and ultimately placed onboard the spacecraft, mitigating most of the associated operational concerns. This paper presents the GSFC closed-loop control method to fly in either constellations or formations through the use of an autonomous closed loop three-axis navigation control and innovative orbit maintenance support. Simulation results using AutoCon(Trademark) and FreeFlyer(Trademark) with various fidelity levels of modeling and algorithms are presented.

Folta, David↗