Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Effects of Modality on Interrupted Flight Deck Performance: Implications for Data Link

Externally-imposed tasks frequently interrupt ongoing task performance in the commercial flight deck. While normally managed without consequence, basic research as well as aviation accident and incident investigations show that interruptions can negatively affect performance and safety. This research investigates the influence of interruption and interrupted task modality on pilot performance in a simulated commercial flight deck. Fourteen current commercial airline pilots performed approach scenarios in a fixed-base flight simulator. Air traffic control instructions, conveyed either aurally or visually (via a data link system) interrupted a visual task (obtaining information from the Flight Management System) and an auditory task (listening to the automated terminal information service recording). Some results confirm the hypothesized performance advantage of cross-modality conditions, more compelling nature of auditory interruptions, and interruption-resistance of auditory ongoing tasks. However, taken together, results suggest the four interaction conditions had different effects on pilot performance. These results have implications for the design of data link systems, and for facilitating interruption management through interface design, aiding, and training programs.

Latorella, Kara A.↗

Nonlinear Dynamic Behavior in the Cassini Spacecraft Modal Survey

In October 1997, the 6-ton robotic spacecraft, Cassini, will lift off from Cape Canaveral atop a Titan IV B rocket, beginning a 7-year journey to Saturn. Upon completion of that voyage, Cassini will send the Huygens probe into the atmosphere of Saturn's largest moon, Titan. Cassini will then spend years studying Saturn's vast realm of rings, icy moons, and magnetic fields. The size and complexity of this endeavor mandates the involvement of many organizations. The Jet Propulsion Laboratory (JPL) manages the project for NASA and is responsible for the spacecraft design, development, and assembly. The NASA Lewis Research Center is the launch system integrator. As is typical for such a spacecraft, a test-verified finite element model is required for loads analysis. JPL had responsibility for the Cassini modal survey and the development of the spacecraft test-verified finite element model. Test verification is a complex and sometimes subjective process. Because of this, NASA Lewis independently verified and validated the Cassini spacecraft modal survey.

Carney, Kelly S.↗

Fluids and Combustion Facility: Combustion Integrated Rack Modal Model Correlation

The Fluids and Combustion Facility (FCF) is a modular, multi-user, two-rack facility dedicated to combustion and fluids science in the US Laboratory Destiny on the International Space Station. FCF is a permanent facility that is capable of accommodating up to ten combustion and fluid science investigations per year. FCF research in combustion and fluid science supports NASA's Exploration of Space Initiative for on-orbit fire suppression, fire safety, and space system fluids management. The Combustion Integrated Rack (CIR) is one of two racks in the FCF. The CIR major structural elements include the International Standard Payload Rack (ISPR), Experiment Assembly (optics bench and combustion chamber), Air Thermal Control Unit (ATCU), Rack Door, and Lower Structure Assembly (Input/Output Processor and Electrical Power Control Unit). The load path through the rack structure is outlined. The CIR modal survey was conducted to validate the load path predicted by the CIR finite element model (FEM). The modal survey is done by experimentally measuring the CIR frequencies and mode shapes. The CIR model was test correlated by updating the model to represent the test mode shapes. The correlated CIR model delivery is required by NASA JSC at Launch-10.5 months. The test correlated CIR flight FEM is analytically integrated into the Shuttle for a coupled loads analysis of the launch configuration. The analysis frequency range of interest is 0-50 Hz. A coupled loads analysis is the analytical integration of the Shuttle with its cargo element, the Mini Payload Logistics Module (MPLM), in the Shuttle cargo bay. For each Shuttle launch configuration, a verification coupled loads analysis is performed to determine the loads in the cargo bay as part of the structural certification process.

McNelis, Mark E.↗

Acoustic-Modal Testing of the Ares I Launch Abort System Attitude Control Motor Valve

The Attitude Control Motor (ACM) is being developed for use in the Launch Abort System (LAS) of NASA's Ares I launch vehicle. The ACM consists of a small solid rocket motor and eight actuated pintle valves that directionally allocate.thrust_- 1t.has-been- predicted-that significant unsteady. pressure.fluctuations.will.exist. inside the-valves during operation. The dominant frequencies of these oscillations correspond to the lowest several acoustic natural frequencies of the individual valves. An acoustic finite element model of the fluid volume inside the valve has been critical to the prediction of these frequencies and their associated mode shapes. This work describes an effort to experimentally validate the acoustic finite model of the valve with an acoustic modal test. The modal test involved instrumenting a flight-like valve with six microphones and then exciting the enclosed air with a loudspeaker. The loudspeaker was configured to deliver broadband noise at relatively high sound pressure levels. The aquired microphone signals were post-processed and compared to results generated from the acoustic finite element model. Initial comparisons between the test data and the model results revealed that additional model refinement was necessary. Specifically, the model was updated to implement a complex impedance boundary condition at the entrance to the valve supply tube. This boundary condition models the frequency-dependent impedance that an acoustic wave will encounter as it reaches the end of the supply tube. Upon invoking this boundary condition, significantly improved agreement between the test data and the model was realized.

Davis, R. Benjamin↗

Adaptive Control of Non-Minimum Phase Modal Systems Using Residual Mode Filters2

Many dynamic systems containing a large number of modes can benefit from adaptive control techniques, which are well suited to applications that have unknown parameters and poorly known operating conditions. In this paper, we focus on a direct adaptive control approach that has been extended to handle adaptive rejection of persistent disturbances. We extend this adaptive control theory to accommodate problematic modal subsystems of a plant that inhibit the adaptive controller by causing the open-loop plant to be non-minimum phase. We will modify the adaptive controller with a Residual Mode Filter (RMF) to compensate for problematic modal subsystems, thereby allowing the system to satisfy the requirements for the adaptive controller to have guaranteed convergence and bounded gains. This paper will be divided into two parts. Here in Part I we will review the basic adaptive control approach and introduce the primary ideas. In Part II, we will present the RMF methodology and complete the proofs of all our results. Also, we will apply the above theoretical results to a simple flexible structure example to illustrate the behavior with and without the residual mode filter.

Balas, Mark J.↗

Nonlinear Reduced-Order Simulation Using An Experimentally Guided Modal Basis

A procedure is developed for using nonlinear experimental response data to guide the modal basis selection in a nonlinear reduced-order simulation. The procedure entails using nonlinear acceleration response data to first identify proper orthogonal modes. Special consideration is given to cases in which some of the desired response data is unavailable. Bases consisting of linear normal modes are then selected to best represent the experimentally determined transverse proper orthogonal modes and either experimentally determined inplane proper orthogonal modes or the special case of numerically computed in-plane companions. The bases are subsequently used in nonlinear modal reduction and dynamic response simulations. The experimental data used in this work is simulated to allow some practical considerations, such as the availability of in-plane response data and non-idealized test conditions, to be explored. Comparisons of the nonlinear reduced-order simulations are made with the surrogate experimental data to demonstrate the effectiveness of the approach.

Rizzi, Stephen A.↗

Modal Test of Six-Meter Hypersonic Inflatable Aerodynamic Decelerator

A modal test was performed on the six-meter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test article to gain a firm understanding of the dynamic characteristics of the unloaded structure within the low frequency range. The tests involved various configurations of the HIAD to understand the influence of the tri-torus, the varying pressure within the toroids and the influence of straps. The primary test was conducted utilizing an eletrodynamic shaker and the results were verified using a step relaxation technique. The analysis results show an increase in the structure's stiffness with respect to increasing pressure. The results also show the rise of coupled modes with the tri-torus configurations. During the testing activity, the attached straps exhibited a behavior that is similar to that described as fuzzy structures in the literature. Therefore extensive tests were also performed by utilizing foam to mitigate these effects as well as understand the modal parameters of these fuzzy sub structures. Results are being utilized to update the finite element model of the six-meter HIAD and to gain a better understanding of the modeling of complex inflatable structures.

Abraham, Nijo↗

Characterization of the Modal Characteristics of Structures Operating in Dense Liquid Oxygen Turbopumps

A number of valuable conclusions can be drawn from this study. First, knockdown factors for a specific fluid are not constant but instead are dependent on the mode shape, although the largest this variability gets is about 10% for LOX, the densest fluid. The factors decrease the most for lower frequency shapes and less for higher ones. It follows, therefore, that mode number mismatch between air and fluid operation becomes not only possible, but common, as a knockdown factor for a particular mode shape may be higher than for another mode shape. Since this is a function of added mass, the mismatch is more prevalent for higher density fluids, but it initiates even for very low density ones. Another important conclusion reached is that it appears that the basic mode shapes of a structure do not change if it is fully symmetric, which includes its geometry and boundary conditions. There is some indication of small changes in the relative magnitudes within the mode shape. This conclusion is evident in the results from the cantilever rectangular plate and the inducer, which are not symmetric, and the fixed-fixed plate and the annular disk, which are. For non-symmetric structures, though, the mode shapes almost universally change for dense fluids, as shown by the very low MAC calculations. For the inducer in particular, the changes follow a trend of reduced parabolic and sine wavelengths with increasing density. It is critical to recognize the change in mode shape for several reasons. First, model updating with modal test becomes problematic if the shapes change. Second, design to avoid resonance is highly critical on the mode shape for modes other than the primary ones, as resonance is only a factor when the excitation shape matches the mode shape. Finally, application of the modal superposition method of forced response analysis is dependent on the use of accurate mode shapes. A more-refined assessment of the "knockdown" factor values and ranges than any previously reported in the literature for a realistic engineering structure is also presented in this paper. This data is of tremendous benefit for preliminary analysis and design, where a quick estimate is necessary. These results are important not just for rocket engine turbomachinery, but for water pumps and turbines, propellers, and any other structure operating in a heavy fluid with dynamic excitation. The clear avenue for future work for this endeavor is to expand the analytical techniques discussed in the literature to develop analytical expressions and justification for the mode shape changes and associated frequency knockdowns. These expressions must be able to accurately predict the functional relationship to the shapes, which will enable accurate tracing of the mode number from vacuum analysis (or testing in air) to analysis and operation in the intended fluid environment.

Chiu, Joseph↗

LPV Modeling of a Flexible Wing Aircraft Using Modal Alignment and Adaptive Gridding Methods

One of the earliest approaches in gain-scheduling control is the gridding based approach, in which a set of local linear time-invariant models are obtained at various gridded points corresponding to the varying parameters within the flight envelop. In order to ensure smooth and effective Linear Parameter-Varying control, aligning all the flexible modes within each local model and maintaining small number of representative local models over the gridded parameter space are crucial. In addition, since the flexible structural models tend to have large dimensions, a tractable model reduction process is necessary. In this paper, the notion of s-shifted H2- and H Infinity-norm are introduced and used as a metric to measure the model mismatch. A new modal alignment algorithm is developed which utilizes the defined metric for aligning all the local models over the entire gridded parameter space. Furthermore, an Adaptive Grid Step Size Determination algorithm is developed to minimize the number of local models required to represent the gridded parameter space. For model reduction, we propose to utilize the concept of Composite Modal Cost Analysis, through which the collective contribution of each flexible mode is computed and ranked. Therefore, a reduced-order model is constructed by retaining only those modes with significant contribution. The NASA Generic Transport Model operating at various flight speeds is studied for verification purpose, and the analysis and simulation results demonstrate the effectiveness of the proposed modeling approach.

LPV Modeling↗

Calculating the Modal Mineralogy of Aubrite Meteorites Using X-Ray Computed Tomography

The aubrites are a group of differentiated meteorites that formed in extremely reducing conditions, with oxygen fugacities (ƒO2) ranging from ~2 to ~6 log units below the Iron-Wüstite buffer. At these extreme conditions, elements that are lithophile (silica-loving) on Earth can behave as chalcophiles (sulfur-loving) or siderophiles (metal-loving), and FeO-poor silicates and exotic sulfides can form. Elemental partitioning among minerals at these conditions are still not well understood, thus studying aubrites could help better constrain elemental behavior. Only 30 aubrites exist; however, they display various textures, which can be difficult to identify in small samples. Identifying composite clasts can help in understanding the igneous history of the aubrite parent bodies. In order to distinguish different minerals and textures in larger samples, we use X-ray computed tomography (XCT), which is a useful, non-destructive analysis that can produce a 3D representation of a meteorite's textures, structures, and modal mineralogy. This study investigates the Norton County aubrite using XCT. Norton County is a fragmental impact breccia aubrite, and was an observed fall with a main mass of 1.1 tons. This large amount of material offers an opportunity to investigate a great volume of reduced, aubritic sample and study a more diverse variety of clasts. Here we report XCT results of two samples of Norton County (NC 15417) in order to constrain the 3D modal mineralogy of silicates, sulfides, and metals, and to identify unique clasts within the matrix.

Wilbur, Zoe↗

Application of Quasi-Static Modal Analysis to an Orion Multi-Purpose Crew Vehicle Test

Bolted structural joints often exhibit load-dependent stiffness and energy dissipation that leads to nonlinear, amplitude dependent frequency and damping in the structure. As an alternative to direct integration of the nonlinear equations of motion, quasi-static modal analysis (QSMA) determines the dependence of frequency and damping on response amplitude using loading behavior from nonlinear static analyses. QSMA has previously been demonstrated to substantially reduce computational cost and maintain accuracy relative to full nonlinear dynamic simulation. This work explores the applicability of QSMA to a complex, large-scale aerospace structure. QSMA is employed to analyze a nonlinear model of test hardware developed to support the Orion Multi-Purpose Crew Vehicle program, which exhibited nonlinear behavior during dynamic testing at flight-like load levels. In addition to the extraction of amplitude-dependent frequency and damping curves, a Bouc-Wen hysteresis model was used in conjunction with the quasi-static results to develop nonlinear, uncoupled, time-domain modal equations of motion for the structure. Excellent agreement was observed between the reduced and full-order nonlinear models, encouraging future employment of QSMA to support accurate and efficient model reduction of structures with bolted joint nonlinearities.

QSMA↗

Uncertainty Quantification of Inducer Natural Frequency using Conditional Assessment of Modeling and Modal Testing of Simpler Systems

The low pressure fuel pump inducer of the new Space Launch System RS25 core stage engine operates in a highly complex environment that substantially affects its modal characteristics. Some of the more important effects are fluid-added mass resulting from operation within a light liquid (Hydrogen), and the magnification of this effect due to tight tip clearance. Since higher order cavitation has been identified as a significant harmonic driver, knowledge of the natural frequency of potentially excitable modes is critical for safe operation, but this frequency cannot be measured during the severe operational environment. A comprehensive testing and analysis program has therefore been performed over the last four years to identify the nominal value and uncertainty of the frequency by modeling and testing four simpler structures which share some of the characteristics of the operational inducer. This testing was used to assess and adjust modeling techniques and excellent correlation was achieved. Identification of the uncertainty in the inducer frequency itself was still problematic, however. This difficulty led to an investigation of Bayesian uncertainty quantification techniques, and to the application of the relatively simple technique of Multi-Variate Normal conditional distributions to calculate the inducer natural frequency uncertainty. Assumptions on prior distributions of uncertainty of the fluid-added mass and tip clearance effect are initially applied to models of each of the simple structures and the inducer itself, and these uncertainties are propagated to generate natural frequencies using design of experiments. Simple response surfaces are then created from this data in order to calculate a Covariance Matrix relating all of these natural frequencies. Finally, the results from modal test of the simple structures are considered to be observations and used to calculate the conditional variance of the desired inducer frequencies. As this method is less rigorous than more complicated Bayesian methods reported in the literature, a conservative factor is applied to the result, but the resulting uncertainty is still significantly less than originally estimated and will greatly assist certification of the inducer for use in the engine.

Uncertainty Quantification↗

Uncertainty Quantification of Inducer Eigenvalues using Conditional Assessment of Models and Modal Test of Simpler Systems

The low pressure fuel pump inducer of the new Space Launch System RS25 core stage engine operates in a highly complex environment that substantially affects its modal characteristics. Some of the more important effects are fluid-added mass resulting from operation within a light liquid (Hydrogen), and the magnification of this effect due to tight tip clearance. Since higher order cavitation has been identified as a significant harmonic driver, knowledge of the natural frequency of potentially excitable modes is critical for safe operation, but this frequency cannot be measured during the severe operational environment. A comprehensive testing and analysis program has therefore been performed over the last four years to identify the nominal value and uncertainty of the frequency by modeling and testing four simpler structures which share some of the characteristics of the operational inducer. This testing was used to assess and adjust modeling techniques and excellent correlation was achieved. Identification of the uncertainty in the inducer frequency itself was still problematic, however. This difficulty led to an investigation of Bayesian uncertainty quantification techniques, and to the application of the relatively simple technique of Multi-Variate Normal conditional distributions to calculate the inducer natural frequency uncertainty. Assumptions on prior distributions of uncertainty of the fluid-added mass and tip clearance effect are initially applied to models of each of the simple structures and the inducer itself, and these uncertainties are propagated to generate natural frequencies using design of experiments. Simple response surfaces are then created from this data in order to calculate a Covariance Matrix relating all of these natural frequencies. Finally, the results from modal test of the simple structures are considered to be observations and used to calculate the conditional variance of the desired inducer frequencies. As this method is less rigorous than more complicated Bayesian methods reported in the literature, a conservative factor is applied to the result, but the resulting uncertainty is still significantly less than originally estimated and will greatly assist certification of the inducer for use in the engine.

Uncertainty Quantification↗

SIR-C Modal Survey: A Case Study in Free-Free Testing

There has been an increased interest recently in developing alternatives to fixed-base modal testing for verification of large Space Shuttle payloads. A promising approach is free-free modal testing, augmented with residual flexibility measurements obtained from interface verification testing. This paper presents summary results from the recent free-free test performed on the Shuttle Imaging Radar-C payload.

SIR-C↗

To the Moon! Space Launch System Modal Testing with Video and Motion Magnification

MIT Lincoln Laboratory and NASA Marshall Space Flight Center have been collaborating on using video camera measurements and motion magnification for modal testing of large aerospace components for several years. This presentation will discuss results from the Space Launch System Integrated Modal Test (IMT) and Dynamic Rollout/Rollback Test (DRRT) in support of the Artemis I mission. During the IMT, the data collection focused on operational mode shapes. In addition, the cameras were repositioned mid-test to better understand the physics of a low-frequency torsion mode. The non-contact nature of video data capture allowed for the quick redeployment of the cameras while not causing any delay in test schedule, whereas traditional instrumentation would have required a pause in testing to attach the sensors to the test article. The motion magnification analysis was able to find the low-frequency operational mode shapes and help the test team better understand the physics of the torsion mode. Building upon the success of the IMT motion magnification work, a camera system was used during the DRRT to find operational mode shapes, if the physics of the low-frequency torsion mode remained with different boundary conditions, and relative deflection of the vehicle and ML tower during the roll. In this paper we will present operational mode shape results, discuss the physics of the torsion mode, and review experimental setup idiosyncrasies to help the community in designing video camera measurement systems.

optical↗

Integrated Modal Test of the Artmis I Launch Vehicle

The dynamic testing campaign for the Artemis I launch vehicle culminated in the Integrated Modal Test (IMT). The IMT consisted of the Space Launch System with a mass simulator of Orion (MSO) on top of the SLS stack, which rested on the deck of the mobile launcher (ML) and mount mechanisms. The modal testing met the goal to capture a set of target modes under 7Hz, in two test configurations, using 298 accelerometer locations and 472 accelerometer channels. Overall the model of the test matched very well with the data without tuning the model with the exception of the first torsion mode, which was measured at a much lower frequency than predicted at when excited at higher levels.

Dan Lazor↗

Alternate Methods of Model Reduction to Avoid Dynamic Modal Truncation Error

Loads analysis is traditionally performed using dynamically reduced models, which provides the benefit to reduce run time. If the reduced model frequency cutoff is not chosen appropriately, the model will lack the dynamic content required to fully represent the response of the non-reduced model. Standard guidance for reduced model frequency content, provided in NASA-STD-5002, is to solve fixed base modes up to a minimum of 1.5x the model frequency content of interest and to employ static modal truncation methods such as residual vectors, the mode acceleration method, and the residual flexibility method to account for the truncated flexibility of the missing modes. Fixed base modes require the selection of a set of degrees of freedom to be constrained which, if not properly selected, may affect the accuracy of the reduced model by excluding some of the dynamic characteristic of the full model. In this case, the standard NASA guidance would be insufficient, but it may not be readily apparent that a portion of the reduced model response is missing. This error was encountered during an independent verification and validation (IV&V) effort, where it was observed that the resulting dynamic response was lower than the inline analysis. In this specific case, despite following the standard NASA model reduction guidelines in the selection of the frequency cutoff, the inline model still did not fully capture the necessary dynamic content. As part of the IV&V, an alternate reduction methodology was employed using an unconstrained mode acceleration method. The original model initially performed a constrained reduction to twice the frequency content of interest before doing a free-free run, employing the mode acceleration method to account for the truncated modes. In contrast in the IV&V, the unconstrained model reduced directly to the needed frequency content of the free-free run, avoiding any interactions between constraints and dynamic content. To verify the model, the original reduction methodology was used to generate a series of Hurty-Craig-Bampton reductions, each with a higher frequency cutoff than the previous. The results were shown to converge once the frequency cutoff increased past eight times the frequency content of interest. At the same frequency cutoff, the results of the Hurty-Craig-Bampton model converged with the results of the unconstrained mode acceleration model. This comparative study provided confidence that the results of the unconstrained modal acceleration reduced model were correct and that the Hurty-Craig-Bampton needed to increase its frequency cutoff to fully capture the dynamic response.

Erin Simmons↗

Alternate Methods of Model Reduction to Avoid Dynamic Modal Truncation Error

Loads analysis is traditionally performed using dynamically reduced models, which provides the benefit to reduce run time. If the reduced model frequency cutoff is not chosen appropriately, the model will lack the dynamic content required to fully represent the response of the non-reduced model. Standard guidance for reduced model frequency content, provided in NASA-STD-5002, is to solve fixed base modes up to a minimum of 1.5x the model frequency content of interest and to employ static modal truncation methods such as residual vectors, the mode acceleration method, and the residual flexibility method to account for the truncated flexibility of the missing modes. Fixed base modes require the selection of a set of degrees of freedom to be constrained which, if not properly selected, may affect the accuracy of the reduced model by excluding some of the dynamic characteristic of the full model. In this case, the standard NASA guidance would be insufficient, but it may not be readily apparent that a portion of the reduced model response is missing. This error was encountered during an independent verification and validation (IV&V) effort, where it was observed that the resulting dynamic response was lower than the inline analysis. In this specific case, despite following the standard NASA model reduction guidelines in the selection of the frequency cutoff, the inline model still did not fully capture the necessary dynamic content. As part of the IV&V, an alternate reduction methodology was employed using an unconstrained mode acceleration method. The original model initially performed a constrained reduction to twice the frequency content of interest before doing a free-free run, employing the mode acceleration method to account for the truncated modes. In contrast in the IV&V, the unconstrained model reduced directly to the needed frequency content of the free-free run, avoiding any interactions between constraints and dynamic content. To verify the model, the original reduction methodology was used to generate a series of Hurty-Craig-Bampton reductions, each with a higher frequency cutoff than the previous. The results were shown to converge once the frequency cutoff increased past eight times the frequency content of interest. At the same frequency cutoff, the results of the Hurty-Craig-Bampton model converged with the results of the unconstrained mode acceleration model. This comparative study provided confidence that the results of the unconstrained modal acceleration reduced model were correct and that the Hurty-Craig-Bampton needed to increase its frequency cutoff to fully capture the dynamic response.

Erin Simmons↗