Search NASA⌕ Search

SEARCH · Search NASA

Results for “Model Based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation

The charge of Task Group 186 (TG-186) is to provide guidance for early adopters of model-based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity. Contrary to external beam radiotherapy, heterogeneity correction algorithms have only recently been made available to the BT community. Yet, BT dose calculation accuracy is highly dependent on scatter conditions and photoelectric effect cross-sections relative to water. In specific situations, differences between the current water-based BT dose calculation formalism (TG-43) and MBDCAs can lead to differences in calculated doses exceeding a factor of 10. MBDCAs raise three major issues that are not addressed by current guidance documents: (1) MBDCA calculated doses are sensitive to the dose specification medium, resulting in energy-dependent differences between dose calculated to water in a homogeneous water geometry (TG-43), dose calculated to the local medium in the heterogeneous medium, and the intermediate scenario of dose calculated to a small volume of water in the heterogeneous medium. (2) MBDCA doses are sensitive to voxel-by-voxel interaction cross sections. Neither conventional single-energy CT nor ICRU/ICRP tissue composition compilations provide useful guidance for the task of assigning interaction cross sections to each voxel. (3) Since each patient-source-applicator combination is unique, having reference data for each possible combination to benchmark MBDCAs is an impractical strategy. Hence, a new commissioning process is required. TG-186 addresses in detail the above issues through the literature review and provides explicit recommendations based on the current state of knowledge. TG-43-based dose prescription and dose calculation remain in effect, with MBDCA dose reporting performed in parallel when available. In using MBDCAs, it is recommended that the radiation transport should be performed in the heterogeneous medium and, at minimum, the dose to the local medium be reported along with the TG-43 calculated doses. Assignments of voxel-by-voxel cross sections represent a particular challenge. Electron density information is readily extracted from CT imaging, but cannot be used to distinguish between different materials having the same density. Therefore, a recommendation is made to use a number of standardized materials to maintain uniformity across institutions. Sensitivity analysis shows that this recommendation offers increased accuracy over TG-43. MBDCA commissioning will share commonalities with current TG-43-based systems, but in addition there will be algorithm-specific tasks. Two levels of commissioning are recommended: reproducing TG-43 dose parameters and testing the advanced capabilities of MBDCAs. For validation of heterogeneity and scatter conditions, MBDCAs should mimic the 3D dose distributions from reference virtual geometries. Potential changes in BT dose prescriptions and MBDCA limitations are discussed. When data required for full MBDCA implementation are insufficient, interim recommendations are made and potential areas of research are identified. Application of TG-186 guidance should retain practice uniformity in transitioning from the TG-43 to the MBDCA approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Agent-Based Models for COVID-19 [Slides]

Goals: 1) Evaluate "what if” scenarios and mitigation strategies to combat COVID-19 spread within LANL and 2) perform retrospective analysis to assess accuracy of LANL COVID-19 agent-based model (ABM).

60 APPLIED LIFE SCIENCES↗

Demonstration of Model-Based Design for Digital Controller Using Formal Methods

This report describes work originally performed in FY19 that assembled a workflow enabling formal verification of high-consequence digital controllers. The approach builds on an engineering analysis strategy using multiple abstraction levels (Model-Based Design) and performs exhaustive formal analysis of appropriate levels – here, state machines and C code – to assure always/never properties of digital logic that cannot be verified by testing alone. The operation of the workflow is illustrated using example models and code, including expected failures of verification when properties are violated.

97 MATHEMATICS AND COMPUTING↗

Model-based interface design for smart field-device integration

Operational complexity is ever-increasing for electric utilities that face challenges including integration of DERs, customer expectation of energy choices, the proliferation of non-utility-owned resources, new business models with energy service providers, and new technology with IT/OT convergence. To maintain and improve the quality of operations, planning, and decision-making in general, utilities need to manage and navigate the complexity. Managing complexity requires a modular, scalable, and flexible solution. Connecting large amounts of DERs and introducing new services requires increased grid control and evolving applications. In this paper, we show an approach utilizing model-based standardized interfaces that simplifies integration and deployment of new algorithms and smart field devices for interoperability across legacy or new systems. A modular design is presented for a reference implementation of widely used DNP3 and IEEE 2030.5 interfaces within an open-source, standards-based data integration platform for integration of smart field devices with independently developed, best-of-breed applications.

Model-driven development, system integration, smar↗

Accelerating structural dynamics simulations with localised phenomena through matrix compression and projection‐based model order reduction

In this work, a novel approach is introduced for accelerating the solution of structural dynamics problems in the presence of localised phenomena, such as cracks. For this category of problems, conventional projection-based Model Order Reduction (MOR) methods are either limited with respect to the range of system configurations that can be represented or require frequent solutions of the Full Order Model (FOM) to update the low-dimensional spaces, in which solutions are represented. In the proposed approach, low-dimensional spaces, constructed for the healthy structure, are enriched with appropriately selected columns of the flexibility matrix of the system. It can be shown that these spaces contain the solution to the original problem for the static case, while their dimension is much smaller. In order to allow their online construction for arbitrary localised features, the full flexibility matrix of the system should be available. To this end, a hierarchical representation is used for the matrices involved, allowing to compute the flexibility matrix efficiently and with reduced memory requirements. The resulting method offers significant speedups, without sacrificing the flexibility and accuracy of the full order model. The performance and limitations of the approach are studied through a series of examples in structural dynamics.

fracture mechanics↗

Driver Distraction Behavior Detection using a Vision Transformer Model based on Transfer Learning Strategy

Driver distraction behavior is one of the critical factors in traffic accidents. Thus, advanced driver state detection system has become the focus in the field of intelligent vehicle. However, in practical applications, insufficient samples of driving distraction behaviors bring great challenges to training a personalized behavior distraction detection model for a specific driver. To this end, a novel transformer model based on a transfer learning strategy is proposed in this paper to accurately recognize driver distraction behavior. Inspired by the effect of the transformer network in visual recognition, we firstly present a transformer behavior distraction detection system to identify the behavior categories that cause driver distraction. Then, for the specific driving dataset in practical application scenarios, the transfer learning strategy is introduced into the driver distraction detection model to further train the general transformer network. The effectiveness of the transformer based on the transfer learning strategy is validated compared with other traditional deep learning methods. The results show that the proposed detection method has better generalization ability and higher accuracy.

Fang, Zhenwu↗

Assessment of Extinction‐, Satellite‐, and Model‐Based Vertical Cloud Condensation Nuclei (CCN) Retrieval Methods Using Airborne CCN Measurements Over the Southern Great Plains

Abstract Accurate estimates of the vertical profile of cloud condensation nuclei (CCN) concentration are crucial to better quantify aerosol‐cloud interactions. We assessed the correlation between the vertical CCN concentrations obtained from extinction‐, satellite‐, and model‐based retrieval methods and airborne CCN concentrations collected at 0.24% supersaturation within the 3, 9, 27, and 81 km regions centered over the U.S. Department of Energy's Atmospheric Radiation Measurement User Facility Southern Great Plains (SGP) site during the spring and summer of 2016. The extinction profiles at a wavelength 355 nm were provided by the ground‐based Raman lidar. Our analysis showed moderate correlation between dry‐corrected extinction and airborne CCN data. We found the retrieved number concentration of CCN (RNCCN) method showed regression best‐fit slopes close to unity and consistent prediction errors for the majority of the data. The Lenhardt et al. (2023, https://doi.org/10.5194/amt‐16‐2037‐2023 ) method showed similar conclusions but only during spring, whereas the Mamouri and Ansmann (2016, https://doi.org/10.5194/acp‐16‐5905‐2016 ) method showed poor correlation. The Shinozuka et al. (2015, https://doi.org/10.5194/acp‐15‐7585‐2015 ) satellite‐based method exhibited reasonable agreement during summer but poor correlation during periods where both high (∼1,400 #/cm 3 ) and low (∼50 #/cm 3 ) airborne CCN concentrations were observed. The Copernicus Atmosphere Monitoring Service reanalysis modeled 3‐D CCN data set showed a moderate to weak positive correlation but performed poorly at high airborne CCN concentrations. Our analysis suggests the extinction‐based RNCCN method performed better than other methods across most observation periods under the diverse meteorological conditions observed at the SGP site.

54 ENVIRONMENTAL SCIENCES↗

A Genome-Based Model to Predict the Virulence of Pseudomonas aeruginosa Isolates

ABSTRACT: Variation in the genome of Pseudomonas aeruginosa , an important pathogen, can have dramatic impacts on the bacterium’s ability to cause disease. We therefore asked whether it was possible to predict the virulence of P. aeruginosa isolates based on their genomic content. We applied a machine learning approach to a genetically and phenotypically diverse collection of 115 clinical P. aeruginosa isolates using genomic information and corresponding virulence phenotypes in a mouse model of bacteremia. We defined the accessory genome of these isolates through the presence or absence of accessory genomic elements (AGEs), sequences present in some strains but not others. Machine learning models trained using AGEs were predictive of virulence, with a mean nested cross-validation accuracy of 75% using the random forest algorithm. However, individual AGEs did not have a large influence on the algorithm’s performance, suggesting instead that virulence predictions are derived from a diffuse genomic signature. These results were validated with an independent test set of 25 P. aeruginosa isolates whose virulence was predicted with 72% accuracy. Machine learning models trained using core genome single-nucleotide variants and whole-genome k-mers also predicted virulence. Our findings are a proof of concept for the use of bacterial genomes to predict pathogenicity in P. aeruginosa and highlight the potential of this approach for predicting patient outcomes. IMPORTANCE Pseudomonas aeruginosa is a clinically important Gram-negative opportunistic pathogen. P. aeruginosa shows a large degree of genomic heterogeneity both through variation in sequences found throughout the species (core genome) and through the presence or absence of sequences in different isolates (accessory genome). P. aeruginosa isolates also differ markedly in their ability to cause disease. In this study, we used machine learning to predict the virulence level of P. aeruginosa isolates in a mouse bacteremia model based on genomic content. We show that both the accessory and core genomes are predictive of virulence. This study provides a machine learning framework to investigate relationships between bacterial genomes and complex phenotypes such as virulence.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-I-49: Vendor-Independent, Model-Based Iterative Reconstruction On a Rotating Grid with Coordinate-Descent Optimization for CT Imaging Investigations

Purpose: Iterative reconstruction methods show promise for improving image quality and lowering the dose in helical CT. We aim to develop a novel model-based reconstruction method that offers potential for dose reduction with reasonable computation speed and storage requirements for vendor-independent reconstruction from clinical data on a normal desktop computer. Methods: In 2012, Xu proposed reconstructing on rotating slices to exploit helical symmetry and reduce the storage requirements for the CT system matrix. Inspired by this concept, we have developed a novel reconstruction method incorporating the stored-system-matrix approach together with iterative coordinate-descent (ICD) optimization. A penalized-least-squares objective function with a quadratic penalty term is solved analytically voxel-by-voxel, sequentially iterating along the axial direction first, followed by the transaxial direction. 8 in-plane (transaxial) neighbors are used for the ICD algorithm. The forward problem is modeled via a unique approach that combines the principle of Joseph’s method with trilinear B-spline interpolation to enable accurate reconstruction with low storage requirements. Iterations are accelerated with multi-CPU OpenMP libraries. For preliminary evaluations, we reconstructed (1) a simulated 3D ellipse phantom and (2) an ACR accreditation phantom dataset exported from a clinical scanner (Definition AS, Siemens Healthcare). Image quality was evaluated in the resolution module. Results: Image quality was excellent for the ellipse phantom. For the ACR phantom, image quality was comparable to clinical reconstructions and reconstructions using open-source FreeCT-wFBP software. Also, we did not observe any deleterious impact associated with the utilization of rotating slices. The system matrix storage requirement was only 4.5GB, and reconstruction time was 50 seconds per iteration. Conclusion: Our reconstruction method shows potential for furthering research in low-dose helical CT, in particular as part of our ongoing development of an acquisition/reconstruction pipeline for generating images under a wide range of conditions. Our algorithm will be made available open-source as “FreeCT-ICD”. NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 ± 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR {sup 192}Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.

07 ISOTOPE AND RADIATION SOURCES↗

Extracting and Interpreting Electrochemical Impedance Spectra (EIS) from Physics-Based Models of Lithium-Ion Batteries

This paper implements a highly efficient algorithm to extract electrochemical impedance spectra (EIS) from physics-based battery models (e.g., a P2D model). The mathematical approach is different from how EIS is practiced experimentally. Experimentally, the voltage (current) is harmonically perturbed over a wide range of frequencies and the amplitude and phase shift of the corresponding current (voltage) is measured. The experimental approach can be implemented in simulation software, but is computationally expensive. The approach here is to determine locally linear state-space models from the full physical model. The four Jacobian matrices that are the basis of the state-space models can be derived by numerical differentiation of the physical model. The EIS is then extracted from the state-space model using computationally efficient matrix-manipulation techniques. The algorithm can evaluate the full EIS at an instant in time during a transient, independent of whether the battery is in a stationary state. The approach is also able to separate the full-cell impedance to evaluate partial EIS, such as for a battery anode alone. Although such partial EIS is difficult to measure experimentally, the partial EIS provides valuable insights in interpreting the full-cell EIS.

25 ENERGY STORAGE↗

Cosmic Ray e +/(e- + e+), p-bar/p Ratios Explained by an Injection Model Based on 2 Gamma-ray Observations

We present a model of cosmic ray (CR) injection into the Galactic space based on recent {gamma}-ray observations of supernova remnants (SNRs) and pulsar wind nebulae (PWNe) by the Fermi Large Area Telescope (Fermi) and atmospheric Cherenkov telescopes (ACTs). Steady-state (SS) injection of nuclear particles and electrons (e{sup -}) from the Galactic ensemble of SNRs, and electrons and positrons (e{sup +}) from the Galactic ensemble of PWNe are assumed, with their spectra deduced from {gamma}-ray observations and recent evolution models. The ensembles of SNRs and PWNe are assumed to share the same spatial distributions and the secondary CR production in dense molecular clouds interacting with SNRs is incorporated in the model. Propagation of CRs to Earth is calculated using GALPROP with 2 source distributions and 2 Galaxy halo sizes. We show that this observation-based model reproduces the positron fraction e{sup +}/(e{sup -} + e{sup +}) and antiproton-to-proton ratio ({bar p}/p) reported by PAMELA reasonably well without calling for new sources. Significant discrepancy is found, however, between our model and the e{sup -} + e{sup +} spectrum measured by Fermi below {approx} 20 GeV. Important quantities for Galactic CRs, including their energy injection, average lifetime, and mean gas density along their typical propagation path are also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model-Based Iterative Reconstruction of Magnetization Using Vector Field Electron Tomography

Vector field electron tomography (VFET) is extensively used for three-dimensional (3-D) imaging of magnetic materials at nanometer resolutions. The conventional approach is to reconstruct and visualize the magnetic vector potential or the magnetic field associated with the sample. There is a lack of algorithms capable of reconstructing the 3-D distribution of magnetization from VFET data. Unlike magnetic vector potential and magnetic field, magnetization is a fundamental physical property of the sample that does not extend beyond the dimensions of the sample. We present a model-based iterative reconstruction algorithm (MBIR) that reconstructs the magnetization by minimizing a cost function consisting of a forward model term and a prior model term. The forward model uses the physics of imaging to model the VFET data as a function of the magnetization, and the prior model enforces sparsity in the magnetization reconstruction. We then formulate an optimization algorithm based on the theory of alternate direction method of multipliers to minimize the resulting MBIR cost function. In conclusion, using simulated and real data, we show that our algorithm accurately reconstructs both the magnetization and the magnetic vector potential.

97 MATHEMATICS AND COMPUTING↗

Model-based versus specific dosimetry in diagnostic context: Comparison of three dosimetric approaches

Purpose: The dosimetric assessment of novel radiotracers represents a legal requirement in most countries. While the techniques for the computation of internal absorbed dose in a therapeutic context have made huge progresses in recent years, in a diagnostic scenario the absorbed dose is usually extracted from model-based lookup tables, most often derived from International Commission on Radiological Protection (ICRP) or Medical Internal Radiation Dose (MIRD) Committee models. The level of approximation introduced by these models may impact the resulting dosimetry. The aim of this work is to establish whether a more refined approach to dosimetry can be implemented in nuclear medicine diagnostics, by analyzing a specific case. Methods: The authors calculated absorbed doses to various organs in six healthy volunteers administered with flutemetamol ({sup 18}F) injection. Each patient underwent from 8 to 10 whole body 3D PET/CT scans. This dataset was analyzed using a Monte Carlo (MC) application developed in-house using the toolkit GATE that is capable to take into account patient-specific anatomy and radiotracer distribution at the voxel level. They compared the absorbed doses obtained with GATE to those calculated with two commercially available software: OLINDA/EXM and STRATOS implementing a dose voxel kernel convolution approach. Results: Absorbed doses calculated with GATE were higher than those calculated with OLINDA. The average ratio between GATE absorbed doses and OLINDA’s was 1.38 ± 0.34 σ (from 0.93 to 2.23). The discrepancy was particularly high for the thyroid, with an average GATE/OLINDA ratio of 1.97 ± 0.83 σ for the six patients. Differences between STRATOS and GATE were found to be higher. The average ratio between GATE and STRATOS absorbed doses was 2.51 ± 1.21 σ (from 1.09 to 6.06). Conclusions: This study demonstrates how the choice of the absorbed dose calculation algorithm may introduce a bias when gamma radiations are of importance, as is the case in nuclear medicine diagnostics.

60 APPLIED LIFE SCIENCES↗

Modeling based assessment of salt cavern performance for underground hydrogen storage

This poster is about the recent progress in my LDRD project of underground hydrogen storage in multiple salt caverns. The main progress of my work is to develop modeling-based workflow to evaluate the salt cavern performance and assess the potential of geomechanical risk for hydrogen storage.

Chang, Kyung Won [Sandia National Laboratories (SN↗

Full-wave and ray-based modeling of cross-beam energy transfer between laser beams with distributed phase plates and polarization smoothing

Radiation-hydrodynamic simulations of inertial confinement fusion (ICF) experiments rely on ray-based cross-beam energy transfer (CBET) models to calculate laser energy deposition. The ray-based models assume locally plane-wave laser beams and polarization averaged incoherence between laser speckles for beams with polarization smoothing. The impact of beam speckle and polarization smoothing on crossbeam energy transfer (CBET) are studied using the 3-D wave-based laser-plasma-interaction code LPSE . The results indicate that ray-based models under predict CBET when the assumption of spatially averaged longitudinal incoherence across the CBET interaction region is violated. A model for CBET between linearly-polarized speckled beams is presented that uses ray tracing to solve for the real speckle pattern of the unperturbed laser beams within the eikonal approximation and gives excellent agreement with the wavebased calculations. Lastly, OMEGA-scale 2-D LPSE calculations using ICF relevant plasma conditions suggest that the impact of beam speckle on laser absorption calculations in ICF implosions is small (< 1%).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2D Bragg Resonators Based on Planar Dielectric Waveguides (from Theory to Model-Based Testing)

Using analytical approaches and CST Microwave Studio 3D simulation, the electrodynamic characteristics of 2D Bragg resonators based on planar dielectric waveguides with doubly periodic corrugation are theoretically analyzed. Such resonators are of great interest to obtain directed narrow-band radiation in heterolasers with large active regions. Model electrodynamic experiments on the “cold” testing of such structures in the millimeter range are performed. Good agreement between the experimental and simulation results is shown, including the existence of the highest-Q mode within the Bragg reflection band in the absence of defects in the periodicity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of Joint European Torus beta scan experiments using theory-based models

Transport modeling of beta ({beta}) scaling experiments performed in the Joint European Torus (JET) [P. H. Rebut et al., Nucl. Fusion 25 1011 (1985)] is presented. Two theory-based models are used: the Weiland model [F. D. Halpern et al., Phys. Plasmas 15, 012304 (2008)] and the gyro-Landau-fluid model GLF23 [J. E. Kinsey et al., Phys. Plasmas 12, 062302 (2005)]. First, the {beta} dependence of energy transport in each model is illustrated by running them stand-alone with imposed plasma profiles obtained in JET {beta} scaling experiments. Both models show a stabilization of ion temperature gradient modes with increasing {beta} up to a critical {beta} value for which ballooning modes become unstable, leading to a strong degradation of the core confinement. Second, the models are used in predictive simulations of heat transport in order to test the capability of the models to reproduce experimental results. A good agreement between the Weiland model and experimental results is found, but the model sensitivity to dimensionless parameters mismatches throughout the experimental scan strongly affects the apparent scaling. This is tested by running predictive simulations using modified input parameters in order to correct the mismatch. In order to identify which dimensionless parameter mismatches are responsible for the apparent scaling, a sensitivity analysis of the Weiland model is performed. A comparison with modeling of previous experimental results is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗