Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiplicity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of a multiplicity dependence in the $\mathcal{p}_T$-differential charm baryon-to-meson ratios in proton–proton collisions at $\sqrt{s}$ = 13 TeV

The production of prompt D 0 , D$^+_s$, and Λ$^+_c$ hadrons, and their ratios, D$^+_s$/D 0 and Λ$^+_c$/D 0 , are measured in proton–proton collisions at $\sqrt{s}$ = 13 TeV at midrapidity (|y| < 0.5) with the ALICE detector at the LHC. The measurements are performed as a function of the charm-hadron transverse momentum (p T ) in intervals of charged-particle multiplicity, measured with two multiplicity estimators covering different pseudorapidity regions. While the strange to non-strange D$^+_s$/D 0 ratio indicates no significant multiplicity dependence, the baryon-to-meson p T -differential Λ$^+_c$/D 0 ratio shows a multiplicity-dependent enhancement, with a significance of 5.3σ for 1 < p T < 12 GeV/c, comparing the highest multiplicity interval with respect to the lowest one. The measurements are compared with a theoretical model that explains the multiplicity dependence by a canonical treatment of quantum charges in the statistical hadronisation approach, and with predictions from event generators that implement colour reconnection mechanisms beyond the leading colour approximation to model the hadronisation process. The Λ$^+_c$/D 0 ratios as a function of p T present a similar shape and magnitude as the Λ/K$^0_s$ ratios in comparable multiplicity intervals, suggesting a potential common mechanism for light- and charm-hadron formation, with analogous multiplicity dependence. The p T -integrated ratios, extrapolated down to p T = 0, do not show a significant dependence on multiplicity within the uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiple Beam Triode Driven RF Sources for Accelerator Applications Phase I Final Report

Calabazas Creek Research, Inc, (CCR), in collaboration with Microwave Power Products, Inc. (MPP), formerly Communications & Power Industries, LLC (CPI,) and JP Accelerator Works, Inc. (JPAW), embarked on a program to develop multiple beam triodes to produce RF power from 350 – 800 MHz with an average power exceeding 200 kW. The effort was motivated by the performance of a triode-based RF source which produces 25 kW of UHF power at 90% efficiency. The CCR effort focused on implementing this technology into a multiple beam device to increase the output power while retaining the low cost, compact size, and high efficiency. The program performed extensive simulations indicating that the goals could be achieved, and a prototype multiple beam triode was built, baked, and tested. Unfortunately, a grid to cathode short terminated the testing before the tube could generate RF power. Nevertheless, the effort demonstrated that a multiple beam triode could be designed, built, baked, and energized to high voltage. The multiple beam triode used oxide cathodes, which are only capable of pulsed operation. The multiple beam triode will be rebuilt using dispenser cathodes, which will allow high duty or continuous operation. The grids were also modified to be more robust to avoid previous issues. The MB triode will provide the beam power for RF generation. The RF is generated by surrounding the triode with input and output cavities to convert beam power to RF power. RF cavities to generate 200 kW CW at 350-450 MHz using the MB triode with dispenser cathodes was assembled during the program. The next Phase of this effort is to assemble the multiple beam triode using the subassemblies built in the Phase I program and test with the RF cavities. The Phase I program also initiated design of a higher frequency, higher power multiple beam triode. That design is forecast to produce approximately 500 kW CW from 350 - 500 MHz.

43 PARTICLE ACCELERATORS↗

Learning and discovering multiple solutions using physics-informed neural networks with random initialization and deep ensemble

In this work we explore the capability of physics-informed neural networks (PINNs) to discover multiple solutions. Many real-world phenomena governed by nonlinear differential equations (DEs), such as fluid flow, exhibit multiple solutions under the same conditions, yet capturing this solution multiplicity remains a significant challenge. A key difficulty lies in providing appropriate initial conditions or guesses, as widely used time-marching schemes and Newton’s method are highly sensitive to these choices when solving complex computational problems. While machine learning models, particularly PINNs, have shown promise in solving DEs, their ability to capture multiple solutions remains underexplored. In this work, we propose a simple and practical approach using PINNs to learn and discover multiple solutions. We first demonstrate that PINNs, when combined with random initialization and deep ensemble method—originally developed for uncertainty quantification—can effectively uncover multiple solutions to nonlinear ordinary and partial DEs. Although training large ensembles of PINNs may appear computationally demanding, this can be done efficiently using vectorization techniques supported by modern deep learning frameworks, allowing many networks to be trained simultaneously. Our approach highlights the critical role of initialization in shaping solution diversity, addressing an often-overlooked aspect of machine learning for scientific computing. Furthermore, we propose utilizing PINN-generated solutions as initial conditions or initial guesses for conventional numerical solvers to enhance accuracy and efficiency in capturing multiple solutions. Extensive numerical experiments, including the Allen–Cahn equation and cavity flow, where our approach successfully identifies both stable and unstable solutions, validate the effectiveness of our method. These findings establish a general and efficient framework for addressing solution multiplicity in nonlinear DEs.

97 MATHEMATICS AND COMPUTING↗

MicroRNAs in blood and cerebrospinal fluid as diagnostic biomarkers of multiple sclerosis and to monitor disease progression

Multiple sclerosis is a chronic autoimmune disease of the central nervous system. It is the main cause of non-traumatic neurological disability in young adults. Multiple sclerosis mostly affects people aged 20–50 years; however, it can occur in young children and much older adults. Factors identified in the distribution of MS include age, gender, genetics, environment, and ethnic background. Multiple sclerosis is usually associated with progressive degrees of disability. The disease involves demyelination of axons of the central nervous system and causes brain and spinal cord neuronal loss and atrophy. Diagnosing multiple sclerosis is based on a patient’s medical history including symptoms, physical examination, and various tests such as magnetic resonance imaging, cerebrospinal fluid and blood tests, and electrophysiology. The disease course of multiple sclerosis is not well correlated with the biomarkers presently used in clinical practice. Blood-derived biomarkers that can detect and distinguish the different phenotypes in multiple sclerosis may be advantageous in personalized treatment with disease-modifying drugs and to predict response to treatment. The studies reviewed have shown that the expression levels of a large number of miRNAs in peripheral blood, serum, exosomes isolated from serum, and cerebrospinal fluid are altered in multiple sclerosis and can distinguish the disease phenotypes from each other. Further studies are warranted to independently validate these findings so that individual or pairs of miRNAs in serum or cerebrospinal fluid can be used as potential diagnostic markers for adult and pediatric multiple sclerosis and for monitoring disease progression and response to therapy.

60 APPLIED LIFE SCIENCES↗

Neutron multiplicity analysis tool

I describe the capabilities of the EXCOM (EXcel based COincidence and Multiplicity) calculation tool which is used to analyze experimental data or simulated neutron multiplicity data. The input to the program is the count-rate data (including the multiplicity distribution) for a measurement, the isotopic composition of the sample and relevant dates. The program carries out deadtime correction and background subtraction and then performs a number of analyses. These are: passive calibration curve, known alpha and multiplicity analysis. The latter is done with both the point model and with the weighted point model. In the current application EXCOM carries out the rapid analysis of Monte Carlo calculated quantities and allows the user to determine the magnitude of sample perturbations that lead to systematic errors. Neutron multiplicity counting is an assay method used in the analysis of plutonium for safeguards applications. It is widely used in nuclear material accountancy by international (IAEA) and national inspectors. The method uses the measurement of the correlations in a pulse train to extract information on the spontaneous fission rate in the presence of neutrons from ({alpha},n) reactions and induced fission. The measurement is relatively simple to perform and gives results very quickly ({le} 1 hour). By contrast, destructive analysis techniques are extremely costly and time consuming (several days). By improving the achievable accuracy of neutron multiplicity counting, a nondestructive analysis technique, it could be possible to reduce the use of destructive analysis measurements required in safeguards applications. The accuracy of a neutron multiplicity measurement can be affected by a number of variables such as density, isotopic composition, chemical composition and moisture in the material. In order to determine the magnitude of these effects on the measured plutonium mass a calculational tool, EXCOM, has been produced using VBA within Excel. This program was developed to help speed the analysis of Monte Carlo neutron transport simulation (MCNP) data, and only requires the count-rate data to calculate the mass of material using INCC's analysis methods instead of the full neutron multiplicity distribution required to run analysis in INCC. This paper describes what is implemented within EXCOM, including the methods used, how the program corrects for deadtime, and how uncertainty is calculated. This paper also describes how to use EXCOM within Excel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CALORIMETER-BASED ADJUSTMENT OF MULTIPLICITY DETERMINED 240PU EFF KNOWN-A ANALYSIS FOR THE ASSAY OF PLUTONIUM

In nuclear material processing facilities, it is often necessary to balance the competing demands of accuracy and throughput. While passive neutron multiplicity counting is the preferred method for relatively fast assays of plutonium, the presence of low-Z impurities (fluorine, beryllium, etc.) rapidly erodes the assay precision of passive neutron counting techniques, frequently resulting in unacceptably large total measurement uncertainties. Conversely, while calorimeters are immune to these impurity effects, the long count times required for high accuracy can be a hindrance to efficiency. The higher uncertainties in passive neutron measurements of impure material are driven by the resulting large (>>2) {alpha}-values, defined as the ({alpha},n):spontaneous fission neutron emission ratio. To counter impurity impacts for high-{alpha} materials, a known-{alpha} approach may be adopted. In this method, {alpha} is determined for a single item using a combination of gamma-ray and calorimetric measurements. Because calorimetry is based on heat output, rather than a statistical distribution of emitted neutrons, an {alpha}-value determined in this way is far more accurate than one determined from passive neutron counts. This fixed {alpha} value can be used in conventional multiplicity analysis for any plutonium-bearing item having the same chemical composition and isotopic distribution as the original. With the results of single calorimeter/passive neutron/gamma-ray measurement, these subsequent items can then be assayed with high precision and accuracy in a relatively short time, despite the presence of impurities. A calorimeter-based known-{alpha} multiplicity analysis technique is especially useful when requiring rapid, high accuracy, high precision measurements of multiple plutonium bearing items having a common source. The technique has therefore found numerous applications at the Savannah River Site. In each case, a plutonium (or mixed U/Pu) bearing item is divided into multiple containers. A single item from that batch is then selected for both neutron and calorimetric measurements; all remaining items undergo a neutron measurement only. Using the technique mentioned above, the 'true' {alpha} value determined from the first (calorimeter and passive neutron measured) item is used in multiplicity analysis for all other items in the batch. The justification for using this {alpha} value in subsequent calculations is the assumption that the chemical composition and isotopic distribution of all batch items are the same, giving a constant ({alpha},n):spontaneous fission ratio. This analysis method has been successfully applied to the KIS Facility, significantly improving measurement uncertainties and reducing processing times for numerous items. Comprehensive plans were later developed to extend the use of this method to other applications, including the K-Area Shuffler and the H-Area Pu-Blending Project. While only the feasibility study for the Shuffler has been completed, implementation of the method in the H-Area Pu-Blending Project is currently in progress and has been successfully applied to multiple items. This report serves to document the details of this method in order to serve as a reference for future applications. Also contained herein are specific examples of the application of known-{alpha} multiplicity analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Validation of the Fast-Neutron Multiplicity Expressions for Fissile Mass Estimation

Neutron multiplicity analysis is a non-destructive assay technique that involves measurement of the multiplets of neutrons that are emitted from fission of fissile material. Typically, multiplicity analysis is conducted by means of a neutron multiplicity counting (NMC) system that uses capture-based thermal-neutron detectors (e.g., 3He-gas detectors). To relieve the reliance on such detectors, we have developed a fast-neutron multiplicity counting (FNMC) system that uses scatter-based, organic scintillators to directly detect the fast fission neutrons emitted from the sample. One challenge with FNMC systems, however, is that they are prone to effects of neutron cross-talk, where a single neutron may scatter and cause more than one detection event. This leads to an overestimate of the fission rate (F) and inaccurate estimation of other sample parameters such as the leakage multiplication (M) and the alpha-ratio (a) when using the traditional capture-based NMC equations. We have formulated fully generalized multiplicity expressions that account for cross-talk effects for any arbitrary order N. The validity of these expressions were verified with MCNPX-PoliMi simulations and experimental measurements; this paper will present the validation of the proposed generalized multiplicity expressions. Californium-252 and Pu metal plates were measured using the FNMC system and the data was used for neutron multiplicity analysis to estimate sample parameters F, M, and a. We demonstrate that accounting for neutron cross-talk effects of order N = 2 and 3 improves the accuracy of the estimated sample parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of Single-Isocenter Volumetric Modulated Arc Radiosurgery for Treatment of Multiple Brain Metastases

Purpose: To evaluate the relative plan quality of single-isocenter vs. multi-isocenter volumetric modulated arc therapy (VMAT) for radiosurgical treatment of multiple central nervous system metastases. Methods and Materials: VMAT plans were created using RapidArc technology for treatment of simulated patients with three brain metastases. The plans consisted of single-arc/single-isocenter, triple-arc (noncoplanar)/single-isocenter, and triple-arc (coplanar)/triple-isocenter configurations. All VMAT plans were normalized to deliver 100% of the 20-Gy prescription dose to all lesions. The plans were evaluated by calculation of Paddick and Radiation Therapy Oncology Group conformity index scores, Paddick gradient index scores, and 12-Gy isodose volumes. Results: All plans were judged clinically acceptable, but differences were observed in the dosimetric parameters, with the use of multiple noncoplanar arcs showing small improvements in the conformity indexes compared with the single-arc/single-isocenter and triple-arc (coplanar)/triple-isocenter plans. Multiple arc plans (triple-arc [noncoplanar]/single-isocenter and triple-arc [coplanar]/triple-isocenter) showed smaller 12-Gy isodose volumes in scenarios involving three metastases spaced closely together, with only small differences noted among all plans involving lesions spaced further apart. Conclusion: Our initial results suggest that single-isocenter VMAT plans can be used to deliver conformity equivalent to that of multiple isocenter VMAT techniques. For targets that are closely spaced, multiple noncoplanar single-isocenter arcs might be required. VMAT radiosurgery for multiple targets using a single isocenter can be efficiently delivered, requiring less than one-half the beam time required for multiple isocenter set ups. VMAT radiosurgery will likely replace multi-isocenter techniques for linear accelerator-based treatment of multiple targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of Multiple Exciton Generation with New Multi-dimensional Spectroscopies

Multiple exciton generation is a process that can occur in semiconductor nanocrystals small enough that their electronic properties deviate from that of the bulk semiconductor. Such small nanocrystals are known as quantum dots. At the time this project began, there were reports that multiple exciton generation in quantum dots was far more efficient than the analogous process of charge carrier multiplication in bulk semiconductors. In bulk semiconductors, this effect requires ultraviolet light, but is used for high energy photo-detectors. By exploiting enhanced photocurrent from photons with more than twice the bandgap energy, carrier multiplication is a potential route to more efficient photovoltaics using quantum dots with infrared bandgaps. The reports of enhanced multiple exciton generation in such materials motivated the fundamental investigations of the multiple exciton generation mechanism in this project. These experimental investigations showed that the initial charge carrier dynamics after exciting low bandgap quantum dots with photons far above bandgap are not those of the bound electron-hole pairs known as excitons, but rather those of the rapidly separating charge carriers found in the bulk semiconductor at similar excitation energies. This result was theoretically explained in terms of new fundamental criteria for size dependent changes in the optical properties of semiconductors. This result indicates that any new mechanism for multiple exciton generation must arise from the larger surface area to volume ratio of quantum dots. Several artifacts arising from repetitive excitation, poorly passivated quantum dot surfaces, and oxygen exposure were found. After eliminating these artifacts, investigations of the backward reaction have confirmed that its rate does increase as size decreases, in accord with theory, but were not able to isolate surface effects. Using two-dimensional electronic spectroscopy to investigate the influence of the surface upon excitation at the bandgap found no measurable effect. These studies indicate that better control of the quantum dot surface would be required to optimize multiple exciton generation for photovoltaics.

14 SOLAR ENERGY↗

Computationally Guided Design of Multiple Impurities Tolerant Electrode (Final Report)

The current project was based on a combined experimental and computational approach, which can help recommend better cathode materials under multiple impurities conditions. The PI will mainly take in charge of experimental and computational thermodynamics of the selected cathode materials for the SOFC applications under multiple impurities. While the co-PI will run the electrochemical tests of the cathodes recommended and eventually the long-term degradation tests. At the end of the project, a multiple tolerant cathode material based on the combined experimental and computational approach will be recommended and the reliability of the commonly used accelerated testing will be evaluated. It will address multiple impurities poisoning effect of SO2, CO2, Cr and H2O on the LSM, LSCF and LNO cathodes by identifying the formation of the detrimental secondary phases by XRD, SEM and TEM techniques. And further recommended cathode material will be subjected to electrochemical testing and the most promising ones will be applied to long-term tests. The hybrid approach the PI proposed will not only be applied to the design of multiple impurities tolerant cathodes but will also be considered in the future oxygen electrode applications in SOECs or reversible SOCs. This hybrid computational and experimental approach includes four sections: 1) Investigation of single impurity poisoning on LSM, LSCF and LNO cathodes in the presence of SO2, CO2, Cr. In this section, LSM, LSCF cathodes from FuelCellMaterials and LNO cathodes from Sol-Gel synthesis will be heat-treated in the above single impurity. And the formation of the secondary phases as well as the corresponding simulations will be cross compared, which shows good agreement between each other. Meanwhile, the accelerated testing approach will be evaluated in these systems compared with the previous published work to understand the reliability of the approach. 2) Investigation of multiple impurities poisoning on LSM, LSCF and LNO cathodes in the presence of Cr+H2O, SO2+Cr and SO2+Cr+H2O conditions. We have also applied these 3 candidate cathodes under these multiple impurities’ conditions and the long-term degradation mechanism of the multiple impurities will be understood with the help of the combined experimental and computational approach. Meanwhile, the synergistic effect of those impurities will be compared with the individual ones in the same cathode system to further reveal the actual operating conditions. 3) Electrochemical testing and polarization of the recommended cathode. We have demonstrated very low polarization resistance in LSCF (core)-LSM (shell) electrodes using MSD process and analyzed impedance spectra using DRT analysis and confirming that the low polarization resistance in LSM infiltrated MSD cells is due to reduction in polarization resistance associated with O2-adsorption process. 4). Long-term degradation testing. We have developed a versatile MSD-based process to deposit various continuous coatings onto porous scaffolds and established baseline for longer term Cr-impurity testing in future projects.

36 MATERIALS SCIENCE↗

Clutter mitigation, multiple peaks, and high-order spectral moments in 35 GHz vertically pointing radar velocity spectra

Abstract. This study presents and applies three separate processing methods to improve high-order moments estimated from 35 GHz (Ka band) vertically pointing radar Doppler velocity spectra. The first processing method removes Doppler-shifted ground clutter from spectra collected by a US Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) program Ka-band zenith pointing radar (KAZR) deployed at Oliktok Point (OLI), Alaska. Ground clutter resulted from multiple pathways through antenna side lobes and reflections off a rotating scanning radar antenna located 2 m away from KAZR, which caused Doppler shifts in ground clutter returns from stationary targets 2.5 km away. After removing clutter in the recorded velocity spectra, the second processing method identifies multiple separate and sub-peaks in the spectra and estimates high-order moments for each peak. Multiple peaks and high-order moments were estimated for both original 2 and 15 s averaged spectra. The third processing step improves the spectrum variance, skewness, and kurtosis estimates by removing velocity variability due to turbulent broadening during 15 s averaging intervals. Applying the multiple peak processing to Doppler velocity spectra during liquid-only clouds can identify cloud and drizzle particles and during mixed-phase clouds can identify liquid cloud and frozen hydrometeors. Consistent with previous studies, this work found that spectrum skewness assuming only a single spectral peak was a good indicator of two hydrometeor populations (for example, cloud and drizzle particles) being present in the radar pulse volume. Yet, after dividing the spectrum into multiple peaks, velocity spectrum skewness for individual peaks is near zero, indicating nearly symmetric peaks. This suggests that future studies should use velocity skewness of single-peak spectra as an indicator of possible multiple hydrometeor populations and then use multiple-peak moments for quantitative studies. Three future activities will continue this work. First, KAZR spectra from several ARM sites have been processed and are available in the ARM archive as a principal investigator (PI) product. ARM programmers are evaluating these processing methods as part of future multiple-peak products generated by ARM. Third, MATLAB code generating the Oliktok Point products has been uploaded as supplemental material for public dissemination.

47 OTHER INSTRUMENTATION↗

Feed System Design Considerations for Large Space Antenna Systems. Part 1: Multiple Apertures with Non-overlapping Feeds

A feed system design for large space antenna systems was considered. A multiple aperture system with nonoverlapping feeds is examined. Circular and quadrant aperture reflector radiation patterns are compared and the effect of adjacent aperture on radiation patterns of multiple aperture reflector antennas is illustrated. The following systems are examined: (1) feed design optimization for a multiple aperture reflector antenna; (2) radiation pattern for two quadrant reflector with optimized feed design; (3) multiple beam concept utliizing apertures and nonoverlapping feeds; (4) beam contours for two quadrant of multiple beam multiple aperture concept; (5) superposition of beams from two quadrants of multiple beam multiple aperture concent; (6)compensation for mislalignment of interleaved beams from two quadrants; and (7) beam quality improvement due to reorienting feed for offset reflector.

Bailey, M. C.↗

Adaptation of the Electra Radio to Support Multiple Receive Channels

Proposed future Mars missions plan communication between multiple assets (rovers). This paper presents the results of a study carried out to assess the potential adaptation of the Electra radio to a multi-channel transceiver. The basic concept is a Frequency Division multiplexing (FDM) communications scheme wherein different receiver architectures are examined. Options considered include: (1) multiple IF slices, A/D and FPGAs each programmed with an Electra baseband modem; (2) common IF but multiple A/Ds and FPGAs and (3) common IF, single A/D and single or multiple FPGAs programmed to accommodate the FDM signals. These options represent the usual tradeoff between analog and digital complexity. Given the space application, a common IF is preferable; however, multiple users present dynamic range challenges (e.g., near-far constraints) that would favor multiple IF slices (Option 1). Vice versa, with a common IF and multiple A/Ds (Option 2), individual AGC control of the A/Ds would be an important consideration. Option 3 would require a common AGC control strategy and would entail multiple digital down conversion paths within the FPGA. In this paper, both FDM parameters as well as the different Electra design options will be examined. In particular, signal channel spacing as a function of user data rates and transmit powers will be evaluated. In addition, tradeoffs between the different Electra design options will be presented with the ultimate goal of defining an augmented Electra radio architecture for potential future missions.

Time Division multiplexing↗

Multiple Benefits of Industrial Energy Efficiency – Lessons Learned and New Initiatives

Past research has shown that energy efficiency implementation in manufacturing can yield additional, quantifiable benefits in areas such as maintenance, production and environmental performance. However, these types of benefits don’t often get identified or estimated during energy efficiency assessments on industrial plants or systems. In addition, these types of benefits are often omitted from conventional performance metrics, leading to overly modest payback calculations and an imperfect understanding of the impact of energy efficiency in manufacturing. If the non-energy related or multiple benefits of energy efficiency measures were to be estimated with good certainty in industrial energy assessments, the true magnitude of energy efficiency measures could be understood, leading to better and more accurate return on investment estimates for energy efficiency projects. According to the IEA report “Capturing the Multiple Benefits of Energy Efficiency (2014),” the monetary value of non-energy benefits stemming from industrial energy efficiency implementation could be in the range of 40% to 50% of the value of energy savings per measure, which could lower energy-efficiency project paybacks by more than half. In order to integrate the potential multiple benefits of energy-efficiency investments in energy efficiency assessments, these benefits need to be identified and quantified during energy efficiency assessments. To help achieve this an effort is underway to develop a training platform to enable companies and individuals who perform energy assessments to include multiple benefits of energy efficiency in project evaluations. This platform will include tools to analyze energy-saving projects, training workshops, and communications techniques and materials to provide the knowledge base to effectively integrate multiple benefits in the investment evaluations of energy efficiency measures. By integrating multiple benefit analyses in the energy assessments and assessment reports it is expected that the business case for energy efficiency will be bolstered leading to greater implementation of energy efficiency projects in manufacturing. This paper will discuss previous research showing the multiple benefits of energy efficiency in manufacturing and the analytical and communications framework that will enable the integration of multiple benefits in energy efficiency assessments.

Lung, Bruce↗

Slow Auger Recombination of Trapped Excitons Enables Efficient Multiple Electron Transfer in CdS–Pt Nanorod Heterostructures

We report solar-to-fuel conversion reaction often requires multiple proton-coupled electron transfer (PCET) processes powered by the energetic electrons and/or holes generated by the absorption of multiple photons. The effective coupling of multiple electron transfer from the light absorber with the multiple PCET reactions at the catalytic center is one of the key challenges in efficient and selective conversion of solar energy to chemical fuels. In this paper, we examine the dynamics of multiple electron transfer in quantum confined CdS nanorods with a Pt tip, in which the CdS rod functions as the light absorber and the Pt tip the catalytic center. By excitation-fluence-dependent transient absorption spectroscopic measurements, we show that the multiexciton Auger recombination rate in CdS rods follows a carrier-collision model, k n A = n 2 (n – 1)/4k 2 A , with a biexciton lifetime (1/k 2 A ) of 2.0 ± 0.2 ns. In CdS–Pt nanorods, electron transfer kinetics from the CdS conduction band edge to the Pt show negligible dependence on the excitation fluence, occurring with a half-life time of 5.6 ± 0.6 ps. The efficiency of multiple exciton dissociation by multiple electron transfer to Pt decreases from 100% in biexciton states to ~41% at 22 exciton state due to the competition with Auger recombination. The half-lifetime of the n-charge separated state recombination (with n electrons in the Pt and n holes in the CdS) decreases from 10 μs in the single charge separated state to 42 ns in nine charge separated states. Our findings suggest the possibility of driving multielectron photocatalytic reactions under intense illumination and controlling product selectivity through multielectron transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Evaluation of Monte Carlo Simulations of Neutron Multiplicity Measurements of Plutonium Metal

In January 2009, Sandia National Laboratories conducted neutron multiplicity measurements of a polyethylene-reflected plutonium metal sphere. Over the past 3 years, those experiments have been collaboratively analyzed using Monte Carlo simulations conducted by University of Michigan (UM), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), and North Carolina State University (NCSU). Monte Carlo simulations of the experiments consistently overpredict the mean and variance of the measured neutron multiplicity distribution. This paper presents a sensitivity study conducted to evaluate the potential sources of the observed errors. MCNPX-PoliMi simulations of plutonium neutron multiplicity measurements exhibited systematic over-prediction of the neutron multiplicity distribution. The over-prediction tended to increase with increasing multiplication. MCNPX-PoliMi had previously been validated against only very low multiplication benchmarks. We conducted sensitivity studies to try to identify the cause(s) of the simulation errors; we eliminated the potential causes we identified, except for Pu-239 {bar {nu}}. A very small change (-1.1%) in the Pu-239 {bar {nu}} dramatically improved the accuracy of the MCNPX-PoliMi simulation for all 6 measurements. This observation is consistent with the trend observed in the bias exhibited by the MCNPX-PoliMi simulations: a very small error in {bar {nu}} is 'magnified' by increasing multiplication. We applied a scalar adjustment to Pu-239 {bar {nu}} (independent of neutron energy); an adjustment that depends on energy is probably more appropriate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗