Search NASA⌕ Search

SEARCH · Search NASA

Results for “NONPROLIFERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Crystal growth of LiIn 1–x Ga x Se 2 crystals

Lithium containing chalcogenide single crystals have become very promising materials for photonics and radiation detection. Detection applications include nuclear nonproliferation, neutron science, and stellar investigations for the search of life. Synthesis and single crystal growth methods for lithium containing chalcogenide, specifically LiIn 1-x Ga x Se 2 , single crystals are discussed. This study elucidates the possibility of improving neutron detection by reducing the indium capture contribution; with the incorporation of the lithium-6 isotope, gallium substitution may overcome the neutron detection efficiency limitation of 6 LiInSe 2 due to appreciable neutron capture by the indium-115 isotope. As a figure of merit, the ternary parent compounds 6 LiInSe 2 and 6 LiGaSe 2 were included in this study. Quality crystals can be obtained utilizing the vertical Bridgman method to produce quaternary compounds with tunable optical properties. Here, quaternary crystals of varying quality depending on the gallium concentration, approximately 5 x 5 x 2 mm 3 or larger in volume, were harvested, analyzed and revealed tunable absorption characteristics between 2.8-3.4 eV.

36 MATERIALS SCIENCE↗

Impacts of future nuclear power generation on the international monitoring system

Many countries are considering nuclear power as a means of reducing greenhouse gas emissions, and the IAEA (IAEA, 2022) has forecasted nuclear power growth rates up to 224% of the 2021 level by 2050. Nuclear power plants release trace quantities of radioxenon, an inert gas that is also monitored under international agreements as a signature of nuclear weapons tests. To better understand how nuclear energy growth (and resulting Xe emissions) could affect this global nonproliferation architecture, we modeled daily releases of radioxenon isotopes used for nuclear explosion detection in the International Monitoring System (IMS) that is part of the Comprehensive Nuclear Test-Ban Treaty: 131m Xe, 133 Xe, 133m Xe, and 135 Xe to examine the change in the number of radioxenon detections as compared to the 2021 detection levels. If a 40-station IMS network is used, the detections of 133 Xe in 2050 would range from 82% for the low-power scenario to 195% for the high-power scenario, compared to the detections in 2021. If an 80-station IMS network is used, the detections of 133 Xe in 2050 would range from 83% of the 2021 detection rate for the low-power scenario to 209% for the high-power scenario. Essentially no detections of 131m Xe and 133m Xe are expected. The high growth scenario could lead to a six-fold increase in 135 Xe detections, but the total number of detections is still small (on the order of 1 detection per day in the entire network).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cell design for laser-induced breakdown spectroscopy measurements on reactive gas samples

Uranium hexafluoride (UF 6 ) is the primary material used for the enrichment of uranium in the production of light water nuclear reactor fuels worldwide. Accurate, rapid quantification of uranium isotopic composition in nuclear materials is required for safeguards programs and nonproliferation purposes. One potential technique for isotopic measurements in uranium species in the field is laser induced breakdown spectroscopy (LIBS). Safe and effective application of LIBS to UF 6 for enrichment measurements is uniquely challenging due to the chemical and physical properties of UF 6 , which necessitate specific handling procedures. The objective of this work is to design a cell for isotopic analysis of UF 6 that is (1) compatible with chemical and physical properties of UF 6 , (2) compatible with LIBS laser, and (3) portable-sized for nuclear safeguards applications. Along with cell design, initial testing of the cell for basic performance and chemical compatibility is performed. As designed and constructed, the portable gas cell was gas-tight, chemically compatible with UF 6 , and withstood long-duration laser exposure. In this work, the cell has proven capability for handling reactive gasses, such as UF 6 , with specification application to isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of a dynamic single bubbler in single and two-phase immiscible liquids

Ensuring nonproliferation and safeguards of special nuclear materials (SNM) is a critical aspect of advancing the nuclear fuel cycle. Traditional bubbler systems used to estimate liquid levels and densities in nuclear recycling processes have limitations, particularly in harsh environments where dip-tube corrosion and buildup necessitate frequent maintenance and recalibration. This study explores the Dynamic Single Bubbler (DSB) method, which utilizes a single dip-tube attached to a linear actuator to estimate liquid properties dynamically. This approach is extended to estimate liquid-liquid interfaces in immiscible liquids and employs a linear regression method to reduce uncertainties and improve accuracy. The DSB method achieved density estimate uncertainties of less than 0.5% and surface level estimate uncertainties typically under 0.5%, across various fluids including water, acetone, methanol, mineral oil, glycerol, and aqueous salt solutions. Results indicate that the DSB method provides accurate and robust estimates of liquid density and surface levels with minimal maintenance and without the need for calibration. Additionally, the method's applicability to immiscible liquids and various dip-tube geometries was demonstrated, showing promise for widespread use in nuclear and other industrial applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Raman and infrared spectra of plutonium (IV) oxalate and its thermal degradation products

For over 80 years, plutonium dioxide has been routinely produced via thermal decomposition of hydrated plutonium(IV) oxalate. Despite the longstanding utility of this process, the chemical structures of starting materials and intermediates produced during this thermal conversion remain ill-defined. To help resolve this uncertainty, we measured high-resolution Raman and infrared spectra of Pu(C 2 O 4 ) 2 ·6H 2 O that was heated to 25, 100, 220, 250, 350, and 450 °C in air. Our measurements show that Pu(C 2 O 4 ) 2 ·6H 2 O has a rich vibrational spectrum with at least 15 Raman bands between 180 cm -1 and 1900 cm -1 and 9 infrared bands between 800 cm -1 and 4000 cm -1 . As Pu(C 2 O 4 ) 2 ·6H 2 O is heated, water is liberated, and the oxalate ligand decomposes to produce plutonium oxycarbide species. When heated to 350 °C or higher, vibrational spectra are consistent with PuO 2 with some residual carbon-containing species. Full vibrational spectra, powder X-ray diffraction, and scanning electron microscopy measurements of Pu(C 2 O 4 ) 2 ·6H 2 O and its thermal degradation products are presented herein along with approximate assignments for observed spectral bands. These data can be used to validate and potentially improve existing computational models that describe the chemical structure of compounds produced during thermal degradation of plutonium (IV) oxalate. Given the utility of plutonium (IV) oxalate in synthesizing plutonium dioxide, these results are expected to provide value in the fields of nuclear fuel processing, nuclear nonproliferation, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33

Neutron measurements can be used to distinguish plutonium in metal or oxide form, a capability that is of great interest in nuclear nonproliferation, treaty verification, and other applications. This paper describes measurements performed on well-characterized samples of plutonium oxide and plutonium metal using the pulse-shape-discrimination-capable plastic scintillator EJ-299-33. Results are compared to those obtained with a same-sized detector cell using the liquid scintillator EJ-309. The same optimized, digital pulse shape discrimination technique is applied to both detectors and the neutron pulse height distributions are compared. Results show that the EJ-299-33 plastics can be successfully used for plutonium measurements, where the gamma ray to neutron detection ratio is much higher than for typical radioactive sources. Results also show that EJ-299-33 detectors can be used to characterize plutonium samples, specifically to discriminate between plutonium metal and oxide.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron pileup algorithms for multiplicity counters

Abstract The shortage of helium-3 (3He) has created a need to identify alternative neutron detection options for a variety of nuclear nonproliferation applications. One application that may be affected by 3He replacement technology is that of mass accountancy for safeguards, which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. The use of neutron scintillation materials, such as LiF-ZnS sheets, as an alternative to 3He proportional tubes in multiplicity counters requires novel techniques for Pulse Shape Discrimination to distinguish between neutrons and gamma rays. These techniques must work under high count rates, as the maximum momentary rate for incoming neutrons from multiplicity events can be quite large. We have created a fast and accurate neutron discrimination algorithm based on time window filtering and signature comparison that can operate quickly on data with high degrees of gamma ray and neutron pileup. This algorithm is evaluated for its capability to separate signals as the pileup rate increases, and the possibility for implementation on fast hardware (e.g., FPGA hardware) for real-time operation is explored.

Robinson, Sean M.↗

Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

Here, we present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3 He-free radiation portal monitor testing campaign at the European Commission’s Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252 Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group’s system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241 Am. Lastly, both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

3He replacement technology↗

The Impact of Gate Width Setting and Gate Utilization Factors on Plutonium Assay in Passive Correlated Neutron Counting

In the field of nuclear safeguards, passive neutron multiplicity counting (PNMC) is a method typically employed in non-destructive assay (NDA) of special nuclear material (SNM) for nonproliferation, verification and accountability purposes. PNMC is generally performed using a well-type thermal neutron counter and relies on the detection of correlated pairs or higher order multiplets of neutrons emitted by an assayed item. To assay SNM, a set of parameters for a given well-counter is required to link the measured multiplicity rates to the assayed item properties. Detection efficiency, die-away time, gate utilization factors (tightly connected to die-away time) as well as optimum gate width setting are among the key parameters. These parameters along with the underlying model assumptions directly affect the accuracy of the SNM assay. In this paper we examine the role of gate utilization factors and the single exponential die-away time assumption and their impact on the measurements for a range of plutonium materials. In addition, we examine the importance of item-optimized coincidence gate width setting as opposed to using a universal gate width value. Finally, the traditional PNMC based on multiplicity shift register electronics is extended to Feynman-type analysis and application of this approach to Pu mass assay is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Angular-resolution and material-characterization measurements for a dual-particle imaging system with mixed-oxide fuel

A dual-particle imaging (DPI) system, capable of simultaneously imaging fast neutrons and gamma rays, has been operated in the presence of mixed-oxide (MOX) fuel to assess the system's angular resolution and material-characterization capabilities. The detection principle is based on the scattering physics of neutrons (elastic scattering) and gamma rays (Compton scattering) in organic and inorganic scintillators. The detection system is designed as a combination of a two-plane Compton camera and a neutron-scatter camera. The front plane consists of EJ-309 liquid scintillators and the back plane consists of interleaved EJ-309 and NaI(Tl) scintillators. MCNPX-PoliMi was used to optimize the geometry of the system and the resulting prototype was built and tested using a Cf-252 source as an SNM surrogate. A software package was developed to acquire and process data in real time. The software was used for a measurement campaign to assess the angular resolution of the imaging system with MOX samples. Measurements of two MOX canisters of similar isotopics and intensity were performed for 6 different canister separations (from 5° to 30°, corresponding to distances of 21 cm and 131 cm, respectively). The measurements yielded a minimum separation of 20° at 2.5 m (86-cm separation) required to see 2 separate hot spots. Additionally, the results displayed good agreement with MCNPX-PoliMi simulations. These results indicate an angular resolution between 15° and 20°, given the 5° step. Coupled with its large field of view, and its capability to differentiate between spontaneous fission and (α,n) sources, the DPI system shows its potential for nuclear-nonproliferation applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Digital pile-up rejection for plutonium experiments with solution-grown stilbene

A solution-grown stilbene detector was used in several experiments with plutonium samples including plutonium oxide, mixed oxide, and plutonium metal samples. Neutrons from different reactions and plutonium isotopes are accompanied by numerous gamma rays especially by the 59-keV gamma ray of 241Am. Identifying neutrons correctly is important for nuclear nonproliferation applications and makes neutron/gamma discrimination and pile-up rejection necessary. Each experimental dataset is presented with and without pile-up filtering using a previously developed algorithm. The experiments were simulated using MCNPX-PoliMi, a Monte Carlo code designed to accurately model scintillation detector response. Collision output from MCNPX-PoliMi was processed using the specialized MPPost post-processing code to convert neutron energy depositions event-by-event into light pulses. The model was compared to experimental data after pulse-shape discrimination identified waveforms as gamma ray or neutron interactions. We show that the use of the digital pile-up rejection algorithm allows for accurate neutron counting with stilbene to within 2% even when not using lead shielding

Bourne, M. M.↗

A 4 x 4 array module of position-sensitive virtual Frisch-grid CdZnTe detectors for gamma-ray imaging spectrometers

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors offer an economical approach to making high efficiency and high energy resolution gamma cameras for spectroscopy and imaging of radioactive sources. There are many application areas for such instruments including gamma-rays astronomy, medical and industrial imaging, nonproliferation and nuclear safeguards. We present the test results from a 4x4 array module coupled to the front-end ASIC. The array houses 16 detectors made of 6x6x20 mm 3 CZT crystals. Each crystal is encapsulated inside an ultrathin polyester shell and furnished with four 5-mm-wide charge-sensing pads placed near the anode on each side of the detector. The pad’s signals are used to measure X-Y coordinates while the cathode signals give the interaction depths (Z coordinates). Combined together the signals provide 3D position information of the interaction points which can be used to correct the detector response non-uniformity. This allows developers to use standard grade (unselected) CZT crystals while retaining high spectroscopic performance comparable with that of the H3D pixelated detectors. The array’s design provides flexibility to replace individual detectors and extend their sizes, potentially increasing upwards of 4 cm in height. We started development of position-sensitive VFG detectors several years ago and today this technology has reached a high-maturity level and is ready to use in practical applications.

3D charge-loss correction↗

Systematic study of variation in radiation data in cluttered environments

There are many challenges to overcome during nuclear nonproliferation measurements, including a wide variety of clutter sources that may be introduced into a scene during acquisition. The ability to understand how the dissimilarity of various objects, or clutter, obscures a detector’s field of view and affects the measured response of the detector improves the input to detection alarm and nuclide identification algorithms. Additionally, having the capability to input clutter variation into radiation transport models would allow for more real-world scenarios to be modeled and understood. Efforts at Oak Ridge National Laboratory have been exploring the ability to determine specific natural background radiation contributions from surroundings, such as buildings, soil, asphalt, and concrete, and use those source terms in large-scale (100 + m) models. The capability to quantify different clutter terms, ranging from humans to large vehicles, allows researchers to inject realistic noise into these models. The work reported herein seeks to explore the effects that clutter introduces to quantify the expected signal variation inherent to both controlled and uncontrolled scenarios, specifically how the introduction of clutter into a scene introduces a variation in signals due to the attenuation of naturally occurring radioactive material distributed within the scene or by introducing non-threatening radioactive materials into the scene. Controlled measurements aim to quantify how different types of clutter of varying size and composition affects the response of a radiation detector. Using results from various controlled tests, the systematic effects of clutter and its effect on radiation readings is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of neutron and gamma-ray cross-correlation functions with 4 He detectors

For the first time, the neutron and gamma-ray time-dependent cross-correlation distributions from spontaneous fission and (α, n) neutron sources are measured with the 4 He fast neutron detectors. The pulse shape discrimination technique based on charge comparison is utilized to discriminate between neutrons and gamma-rays in the identification of the four possible correlated pairs: (γ, γ), (n, n), (γ, n), and (n, n). Both total and individual cross-correlation functions are obtained, and their shapes can be easily distinguished among different neutron sources. The (n, n) and (γ, n) correlations are selectively analyzed and the peak position of the (n, n) and (γ, n) pairs shows a linear correlation with source-detector distance. Here, the measurements illustrate the feasibility of using 4 He detectors to identify nuclear materials and their geometrical configurations, as well as other applications in nuclear nonproliferation and safeguards. In particular, the (n, n) correlated data can be very clearly assayed even in the presence of significant gamma fields without the use of shielding.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the two-region Rossi-alpha model for reflected assemblies

Nuclear criticality safety, nonproliferation and safeguards, emergency response, and stockpile stewardship utilize estimates of the k eff multiplication factor. The value of k eff cannot be directly measured, but it can be inferred from the prompt neutron period. One modality of measuring the prompt neutron period is the Rossi-alpha method, which is predicated on fitting a histogram of detection time differences due to the nonrandom temporal distribution of same-fission-chain neutrons. Recent works have developed the motivation and theory to expand traditional one-region point kinetic models resulting in one-exponential histogram fits to two-region models that result in two-exponential fits. This paper validates the new two-region model using organic scintillator measurements of copper-reflected weapons-grade plutonium (0:83 ≤ k eff ≤ 0:94) and high-density- polyethylene-reflected highly enriched uranium (0:73 ≤ k eff ≤ 0:95). Furthermore, the results show that more thermal systems have shorter prompt neutron periods in the core region due to increased induced-fission probabilities for moderated neutrons. Here, a new parameter introduced by the two- region model is also shown to be correlated to the amount of reflection, and may be used to infer assembly properties such as type and amount of reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Short-lived photofission product yields from 238 U and 232 Th at Bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV for nuclear forensics isotope production applications

The existing photofission product yield data sets are often based on nuclear models, and limited experimental measurements of these fission product yields have been performed. These experiments resulted in measured cumulative fission product yields (CFPYs) for 238 U and 232 Th for the bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV. The half-lives of the reported fission products range from 1.07–40.8 s. This work is motivated by a demonstrated need for novel isotope production methods for nuclear forensics and improved nuclear data to support the nonproliferation community. A high-purity germanium detector and a pneumatic transfer system were employed for measurements of short-lived fission products, collecting data between cycles of accelerator irradiation and measurement.

07 ISOTOPE AND RADIATION SOURCES↗

The effects of low- Z shielding on uranium isotope discrimination using the time-emission profiles of long-lived delayed neutrons

Characteristic radiation signals can often be obscured or distorted by relatively small amounts of shielding, as is the case for highly-enriched uranium (HEU). Methods that can detect and identify special nuclear material (SNM) even in the presence of shielding are therefore of high value in many nuclear security and nonproliferation applications. It has been previously shown that the buildup and decay time profiles of long-lived delayed neutron emission from induced fission are unique and can be used to successfully discriminate between uranium isotopes and infer enrichment without the need for a calibration standard. Because the long-lived delayed neutron precursors exhibit decay times on the order of tens of seconds, their time profiles are not sensitive to the delays associated with scattering or diffusion in shielding materials, which occur on much shorter time scales. The use of capture-based neutron detectors can also mitigate the effects of shielding, because unlike recoil-based detectors, they do not have a low-energy detection threshold, so that neutrons that lose their energy in the shielding are still detectable. In this work, the effects of low-Z shielding on the discrimination of uranium isotopes using delayed neutron time profile measurements are investigated for the first time. Furthermore, the delayed neutron buildup and decay time profiles of polyethylene-shielded HEU and depleted uranium objects are measured using two different capture-gated detector designs. The recorded profiles show good agreement with the shapes predicted from six-group delayed neutron models even with the shielding in place, and the enrichment of the HEU and DU objects was estimated accurately to within 5%. While this method shows potential for discriminating and characterizing extreme cases of enrichment when a moderate amount of shielding is present, simulation results suggest that significant limitations exist for intermediate enrichment levels due to distortions to the delayed neutron time profile caused by neutron reflection in the shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗