Measurement of the Neutron Electromagnetic Form Factors at High Momentum Transfer Using a Polarized 3He Target at Jefferson Lab
Ever since the composite structure of nucleons was uncovered, many experiments have been commissioned with the purpose of extracting parameters that shape our understanding of this structure. Form factors are powerful tools that rest at the forefront of the nucleon structure study. In the non-relativistic limit, they describe the magnetic and charge distributions inside the nucleon. The GEn-II experiment, which ran in Hall A of Jefferson Lab as a part of the SuperBigbite Spectrometer (SBS) program, aimed to extract the ratio of the neutron’s electric to magnetic Sachs form factors (GnE/GnM. This was accomplished using the double polarization technique: scattering polarized electrons with initial energies up to 8.45 GeV off high-density polarized 3He targets. The experiment was a coincidence measurement, with the scattered electrons detected in the BigBite Spectrometer and the recoil nucleons in a hadron calorimeter, a part of the SuperBigbite Spectrometer. The convection-style target cells used in this experiment have a 60cm long target chamber, an increase from the 40 cm cell used in the most recent polarized 3He target experiment. In addition, the cells were optically pumped from two sides of the pumping chamber. These improvements in design and functionality introduced world-record-breaking luminosity. This thesis presents preliminary results of the GEn-II experiment for the following 4-momentum transfer (Q2) values: 2.93, 6.76, and 9.78 GeV2, in addition to target performance and preliminary polarimetry results.