Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nitrogen Flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Initial Thrust Measurements of Marshall's Ion-ioN Thruster

Electronegative ion thrusters are a variation of traditional gridded ion thruster technology differentiated by the production and acceleration of both positive and negative ions. Benefits of electronegative ion thrusters include the elimination of lifetime-limiting cathodes from the thruster architecture and the ability to generate appreciable thrust from both charge species. While much progress has been made in the development of electronegative ion thruster technology, direct thrust measurements are required to unambiguously demonstrate the efficacy of the concept and support continued development. In the present work, direct thrust measurements of the thrust produced by the MINT (Marshall's Ion-ioN Thruster) are performed using an inverted-pendulum thrust stand in the High-Power Electric Propulsion Laboratory's Vacuum Test Facility-1 at the Georgia Institute of Technology with operating pressures ranging from 4.8 x 10(exp -5) and 5.7 x 10(exp -5) torr. Thrust is recorded while operating with a propellant volumetric mixture ratio of 5:1 argon to nitrogen with total volumetric flow rates of 6, 12, and 24 sccm (0.17, 0.34, and 0.68 mg/s). Plasma is generated using a helical antenna at 13.56 MHz and radio frequency (RF) power levels of 150 and 350 W. The acceleration grid assembly is operated using both sinusoidal and square waveform biases of +/-350 V at frequencies of 4, 10, 25, 125, and 225 kHz. Thrust is recorded for two separate thruster configurations: with and without the magnetic filter. No thrust is discernable during thruster operation without the magnetic filter for any volumetric flow rate, RF forward Power level, or acceleration grid biasing scheme. For the full thruster configuration, with the magnetic filter installed, a brief burst of thrust of approximately 3.75 mN +/- 3 mN of error is observed at the start of grid operation for a volumetric flow rate of 24 sccm at 350 W RF power using a sinusoidal waveform grid bias at 125 kHz and +/- 350 V. Similar bursts in thrust are observed using a square waveform grid bias at 10 kHz and +/- 350 V for volumetric flow rates of 6, 10, and 12 sccm at 150, 350, and 350 W respectively. The only operating condition that exhibits repeated thrust spikes throughout thruster operation is the 24 sccm condition with a 5:1 mixture ratio at 150 W RF power using the 10 kHz square waveform acceleration grid bias. Thrust spikes for this condition measure 3 mN with an error of +/- 2.5 mN. There are no operating conditions tested that show continuous thrust production.

Caruso, Natalie R. S.↗

Validation of Heat Transfer Correlations in Line Chill-Down Tests of Cryogenic Fluid in SINDA/FLUINT

Line Chill-down heat transfer was modelled using SINDA/FLUINT. Multiple chill-down tests were modelled using the heat transfer correlations that are available in SINDA/FLUINT, as well as incorporating heat transfer empiricisms developed by the University of Florida1 based on a series of liquid nitrogen chill-down tests. The chill-down tests that were modelled were the liquid nitrogen tests conducted by the University of Florida1 as well as liquid hydrogen tests conducted by NASA Glenn Research Center2. The liquid nitrogen tests included horizontal flow, upward flow, and downward flow with the liquid Reynolds Numbers ranging 850 - 231,000. The liquid hydrogen test was vertical upward flow at a Reynolds Number range of 18,400 - 433,000. Both the University of Florida's heat transfer correlations and SINDA/FLUINT's internal correlations faired similarly to wall temperature test data. They were acceptable although improvements could be made to the University of Florida correlations as well and SINDA/FLUINT's internal correlations.

cryogenic modeling↗

Tonlé Sap Food Security and Agriculture II: Evaluating Changes in Ecosystem Vitality and Freshwater Healthin the Tonlé Sap Basin using Remotely Sensed Data

The Tonlé Sap Lake and river basin in central Cambodia provide critical ecosystem services to the region, including fisheries, agricultural irrigation, hydropower, and biodiverse habitats. Deforestation, increased pumping for farming, and effects of climate change such as droughts and forest fires threaten the health of the lake and food security in the region. This project built upon the previous term through a partnership with Conservation International (CI), the Cambodian Ministry of Water Resources and Meteorology, and the Tonlé Sap Authority to assess ecosystem vitality and implement CI’s Freshwater Health Index (FHI) tool, in an effort to prioritize resource expenditure and highlight areas of concern. Due to the COVID-19 pandemic and related travel restrictions, partners had not been able to readily collect in situ data for the past year, which make up the majority of FHI inputs. To help fill this data gap, we developed a methodology for using Gravity Recovery and Climate Experiment (GRACE) satellite data to calculate groundwater storage depletion, and a Python Application Programming Interface for processing and formatting remotely-sensed data for the Soil and Water Assessment Tool (SWAT) model. We then used SWAT to model nutrient flows and of phosphorous, nitrogen and suspended sediments amounts in the basin from October 2000 to December 2020. These outputs served as inputs for the FHI and provided policy makers with robust monitoring information to aid decision-making in the area and safeguard the lake’s vital fisheries and biodiversity.

Justine Spore↗

Modernization of NASA's Johnson Space Center Chamber: A Liquid Nitrogen System to Support Cryogenic Vacuum Optical Testing of the James Webb Space Telescope (JWST)

NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the “Great Observatories”, scheduled for launch in 2018. It is directly responsible for the integration and test (I&T) program that will culminate in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describes the steps performed in efforts to convert the existing the 60’s era Liquid Nitrogen System from a forced flow (pumped) process to a natural circulation (thermo-siphon) process. In addition, the paper will describe the dramatic conservation of liquid nitrogen to support the long duration thermal vacuum testing. Lastly, describe the simplistic and effective control system which results in zero to minimal human inputs during steady state conditions.

Garcia, Sammy↗

Thickness and Fuel Preheating Effects on Material Flammability in Microgravity from the BASS Experiment

The Burning and Suppression of Solids (BASS) experiment was performed on the International Space Station. Microgravity combustion tests burning thin and thick flat samples, acrylic spheres, and candles were conducted. The samples were mounted inside a small wind tunnel which could impose air flow speeds up to 40 cms. The wind tunnel was installed in the Microgravity Science Glovebox which supplied power, imaging, and a level of containment. The effects of air flow speed, fuel thickness, fuel preheating, and nitrogen dilution on flame appearance, flame growth, and spread rates were determined in both the opposed and concurrent flow configuration. In some cases, a jet of nitrogen was introduced to attempt to extinguish the flame. Microgravity flames were found to be especially sensitive to air flow speed in the range 0 to 5 cms. The gas phase response is much faster compared to the solid and so as the flow speed is changed, the flame responds with almost no delay. At the lowest speeds examined (less than 1 cms) all the flames tended to become dim blue and very stable. However, heat loss at these very low convective rates is small so the flames can burn for a long time. At moderate flow speeds (between about 1 and 5 cms) the flame continually heats the solid fuel resulting in an increasing fuel temperature, higher rate of fuel vaporization, and a stronger, more luminous flame as time progresses. Only the smallest flames burning acrylic slabs appeared to be adversely influenced by solid conductive heat loss, but even these burned for over 5 minutes before self-extinguishing. This has implications for spacecraft fire safety since a tiny flame might be undetected for a long time. While the small flame is not particularly hazardous if it remains small, the danger is that it might flare up if the air convection is suddenly increased or if the flame spreads into another fuel source.

Combustion↗

Optical characterization of clouds of fine liquid-nitrogen particles

Characteristic drop size, D sub 32, of clouds of fine liquid nitrogen particles was measured with a scattered light scanning instrument developed at NASA-Lewis. Calibration of the instrument was accomplished with suspensions of monosized polystyrene spheres and the scattered light scanner was then used to investigate the mechanism of liquid nitrogen jet disintegration in high velocity gas flow. The Sauter mean diameter, D sub 32, was found to vary inversely with nitrogen gas mass-flux raised to the 1.33 power. Values of D sub 32 varied from 5 to 25 microns and the mass-flux exponent 1.33 agrees well with theory for liquid jet breakup in high velocity gas flow. Loss of fine particles due to the high vaporization rate of liquid nitrogen was avoided by sampling the spray 1.3 cm downstream of the nozzle orifice. The presence of high velocity and thermal gradients in the gas phase also made sampling of the particles quite difficult. As a result, it was necessary to correct the measurements for background noise produced by both highly turbulent gas flow and thermally induced density gradients in the gas phase.

Ingebo, Robert D.↗

Application of the principle of corresponding states to two-phase choked flow.

If the possibility of applying the principle is valid, designers, using data from other fluids to support them, could apply the theory of their choice to fluids where there is little or no data, such as oxygen. Two-phase critical flow and critical flow pressure ratio of simple fluids through a nozzle are shown to nearly obey the principle of corresponding states. The normalization of corresponding states presented is supported by nitrogen and methane two-phase choked flow data. Since the reduced curves for nitrogen, oxygen, and methane are so close, it is felt that oxygen two-phase choked flow can be predicted using corresponding states reduction and relying on nitrogen and methane data to establish the appropriate theory to use.

Hendricks, R. C.↗

Electrical conductivity and velocity of highly ionized plasma flows - Theory and experiment.

Use of an immersible, three-coil, magnetic-induction probe, previously tested in a low-density supersonic argon jet, to measure electrical conductivity and velocity profiles of a highly ionized high-density nitrogen jet in the continuum flow regime where effects due to probe bow shocks and boundary layers might not be negligible. Measured centerline values of electrical conductivity and velocity were compared with predictions based on a theoretical analysis previously developed to study the gas as it expanded adiabatically and inviscidly from an equilibrium sonic state to the nozzle exit. The resulting numerical exit plane values for electron density and electron temperature were then substituted into the Spitzer-Haerm conductivity formula to compute a theoretical conductivity which agreed within 40% of the measured conductivity, while the calculated and experimental velocity values differed by as much as 50%. The lack of agreement was attributed to the possible use of invalid assumptions and boundary conditions in the computer analysis or to the unknown effects of shocks on the probe data.

Vendell, E. W.↗

Design and test of porous-tungsten mercury vaporizers.

Future use of large size Kaufman thrusters and thruster arrays will impose new design requirements for porous plug type vaporizers. Larger flow rate coupled with smaller pores to prevent liquid intrusion will be desired. This paper presents the results of testing samples of porous tungsten for flow rate, liquid intrusion pressure level, and mechanical strength. Nitrogen gas was used in addition to mercury flow for approximate calibration. Liquid intrusion pressure levels will require that flight thruster systems with long feed lines have some way (a valve) to restrict dynamic line pressures during launch.

Kerslake, W. R.↗

HYPERFIRE

The two main sub-scale, ground-based rocket aerodynamics testing techniques – hot-fire testing and cold-flow testing – pose a series of tradeoffs. Hot-fire testing is generally much more accurate, but is often burdensome, costly, and requires long lead times due to design work, infrastructure preparation, etc. Cold-flow testing is much less expensive and has a rapid turnaround time, but conventional simulants (e.g., nitrogen, steam) used in cold-flow testing yield less accurate results (i.e., results that are not sufficiently representative of test article performance). While researching methods to optimize such tradeoffs, engineers at NASA’s Stennis Space Center discovered that ethane can be tuned to approximate rocket exhaust plumes generated by several common rocket propellants. This led NASA to develop the HYdrocarbon Propellants Enabling Reproduction of Flows in Rocket Engines (HYPERFIRE), a sub-scale, non-reacting flow test system. HYPERFIRE uses heated ethane to enable physical simulation of rocket engines powered by a broad range of propellants in an inexpensive, accurate, and simple fashion.

sub-scale↗

Dual Stokes cars measurements in supersonic combusting flow

Coherent antiStokes Raman spectroscopy (CARS) was used to make simultaneous measurements of temperature, nitrogen and oxygen density in a reacting supersonic flow. A supersonic burner (SSB) was designed to provide supersonic flow in which combustion can be studied in the laboratory. Measurements made with the CARS system will be used for validation of computational fluid dynamic (CFD) codes. Preliminary results of the CFD calculations are presented.

Jarrett, Olin, Jr.↗

Flaw growth of 6Al-4V STA titanium in nitrogen tetroxide with low nitric oxide content

The sustained load flow growth characteristics of surface flowed 6Al-4V STA titanium specimens were determined when exposed to nitrogen tetroxide N2O4 having nitric oxide (NO) concentrations of 0.06 to 0.30%. Test temperatures ranged from 70 to 150 F. It was observed that the threshold stress intensity for the titanium decreased abruptly below on NO concentration of 0.18% and also decreased as the temperature increased. The threshold stress intensity was determined to be greater than or equal to 60% of the critical stress intensity for NO concentrations of 0.18 to 0.30% and temperatures of 90 and 120 F. Sustained load tests conducted in N2O4 vapor with a 0.30% NO concentration at 120 F indicated the threshold to be also greater than or equal to 60% of critical.

Bixler, W. D.↗

Real gas effects 2: Influence of condensation on minimum operating temperatures of cryogenic wind tunnels

Condensation effects are responsible for the minimum operating temperatures of cryogenic wind tunnels at total pressures up to about 9 atmospheres. The two primary modes of condensation homogeneous nucleation and heterogeneous nucleation and the conditions with which either may limit minimum operating temperatures are reveiwed. Previous hypersonic and supersonic condensation data are reviewed as are data taken in the nitrogen gas, Langley 0.3 Meter Transonic Cryogenic Tunnel. Analysis of data in the 0.3 m tunnel suggests that the onset of homogenous nucleation may be approximated by an analysis by sivier and that the onset of heterogeneous nucleation is only apparent just below free stream saturation. Extension of the results from the 0.3 m tunnel to other nitrogen gas cryogenic tunnels is discussed and is shown to depend on length scales, purity of the liquid nitrogen injected for cooling, number of particulates in the flow, and the extent to which the injected liquid nitrogen is evaporated.

Hall, R. M.↗

Turbulent mixing in supercritical jets: effect of compressibility factor and inflow condition

Fuel injection and turbulent mixing at supercritical pressures determines ignition and combustion in numerous engineering applications. Flow evolution under such conditions is characterized by strong non-linear coupling between dynamics, transport coefficients, and thermodynamics. Experimental studies observe that the jets injected at supercritical pressures exhibit significantly different dynamics from the jets at subcritical conditions, owing to the lack of distinct liquid and gas phases in supercritical state. Thus, the averaged flow quantities such as the potential core length, jet spatial growth rate and velocity decay profiles differ in the two conditions, resulting in different mixed-fluid distributions. In this study, turbulent jet direct numerical simulations (DNS) are performed to examine the variations in flow statistics between injection of Nitrogen (N₂) in Nitrogen (N₂) at both subcritical (perfect-gas) and supercritical conditions. In all cases, isothermal round jets at Reynolds number (Re_{D}), based on jet diameter (D) and jet orifice velocity (U₀), of 5000 are considered. For mixing analyses, a passive scalar transported with the flow is examined.

Sharan, Nek↗

The flow field of an underexpanded H2 jet coaxially injected into a hot free or ducted supersonic jet of air or nitrogen

Experimental data obtained in an investigation of the mixing of an underexpanded hydrogen jet in a supersonic flow both with and without combustion are presented. Tests were conducted in a Mach 2 test stream with both air and nitrogen as test media. Total temperature of the test stream was 2170 K, and static exit pressure was about one atmosphere. The static pressure at the exit of the hydrogen injector's Mach 2 nozzle was about two atmospheres. Primary measurements included shadowgraphs and pitot pressure surveys of the flow field. Pitot surveys and wall static pressures were measured for the case where the entire flow was shrouded. The results are compared to similar experimental data and theoretical predictions for the matched pressure case.

Jenkins, R. V.↗