Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Observations of gamma-ray line profiles from SN 1987A

Fully resolved gamma-ray line observations from the decay of Co-56 in SN 1987A are presented. Data are from the first two balloon flights of the Gamma-Ray Imaging Spectrometer. On day 433 (after the initial optical sighting) the 847 and 1238 keV lines from Co-56 were observed at 2.3 and 4.3 sigma significance. On day 613, the lines at 847, 1238, and 2599 keV were observed at 4.6, 3.4, and 1.9 sigma, respectively. The combined significance for the three-line complex in both flights is 7.8 sigma. Gaussian profiles yield acceptable least-squares fits to the lines. The line profiles are centered on the red side of the rest energy with typical velocity dispersions of about 3500 km/s FWHM, consistent with an optically thin source, but the line intensities are less than about 30 percent of those produced by the 0.075 solar mass of Co-56 determined from the bolometric light curve.

Tueller, J.↗

Planetary Camera observations of the M87 stellar cusp

Results are presented of an analysis of V- and I-band HST Planetary Camera images of the giant elliptical galaxy M87 which show that its central starlight distribution is consistent with the black hole 2.6 x 10 exp 9-solar-mass cup model proposed for M87 by Young et al. (1978). A combined approach of image deconvolution and modeling is used to investigate the starlight distribution into limiting radii of about 0.04 arcsec. The central structure of M87 is described by three components: a power-law starlight profile of the form mu(r) varies as r exp -1/4 for r of less than 3 arcsec, a central nonthermal point source, and optical counterparts of the jet knots N1 and M identified by VLBI observations.

Lauer, Tod R.↗

Measuring Small Changes In Aim Of An Instrument

Optoelectronic system measures small changes in direction of line of sight of instrument. Optical point source and lens mounted on x-ray telescope in reverse configuration - as projector. Magnified relative lateral motion of point source and lens imaged on position-sensing photodetector.

Arenberg, Jonathan W.↗

The 1.083 micron tunable CW semiconductor laser

A tunable CW laser is desired to produce light equivalent to the helium spectral line at 1.08 microns. This laser will serve as an optical pumping source for He-3 and He-4 atoms used in space magnetometers. This light source can be fabricated either as a semiconductor laser diode or a pumped solid state laser. Continuous output power of greater than 10 mW is desired. Semiconductor lasers can be thermally tuned, but must be capable of locking onto the helium resonance lines. Solid state lasers must have efficient pumping sources suitable for space configuration. Additional requirements are as follows: space magnetometer applications will include low mass (less than 0.5 kg), low power consumption (less than 0.75 W), and high stability/reliability for long missions (5-10 years).

Wang, C. S.↗

Highlights of the theoretical work reported at the workshop

A brief overview is given of the theoretical work done on gamma-ray bursts (GRBs) done in this workshop. Papers on energy source models, optical transients, X-ray and gamma-ray continuum models, and cyclotron line models are reviewed.

Lamb, D. Q.↗

Search for deterministic pulse trends in gamma ray burst temporal profiles

Most cosmic gamma-ray burst temporal profiles appear to be comprised of several individual pulses, many of which overlap. It is advantageous to deconvolve the temporal structures into their constituent pulses, and thereby investigate the shape, intensity and temporal distributions of the pulses as a function of energy. Such fundamental pulse descriptors would provide constraints for theoretical modeling of the burst emission process, such as indications of source size, optical depth and geometry, as a function of time. We have developed a deconvolution algorithm which treats sequences of pulse shapes that change deterministically. The algorithm, a generalization of autoregressive techniques, has been applied to a few bright bursts observed by BATSE. Results indicate that, even within short intervals, constituent pulses are not self-similarly shaped, nor do pulse shapes evolve in a simple manner throughout a burst. Hence, the direction of our future work on pulse deconvolution will focus on analysis methods which allow pulse shape to vary.

Norris, J. P.↗

Oscillator strengths of the Si II 181 nanometer resonance multiplet

We report Si II experimental log (gf)-values of -2.38(4) for the 180.801 nm line, of -2.18(4) for the 181.693 nm line, and of -3.29(5) for the 181.745 nm line, where the number in parentheses is the uncertainty in the last digit. The overall uncertainties (about 10 percent) include the 1 sigma random uncertainty (about 6 percent) and an estimate of the systematic uncertainty. The oscillator strengths are determined by combining branching fractions and radiative lifetimes. The branching fractions are measured using standard spectroradiometry on an optically thin source; the radiative lifetimes are measured using time-resolved laser-induced fluorescence.

Bergeson, S. D.↗

Oscillator strengths for Fe II transitions at 224.918 and 226.008 nanometers

We report accurate experimental absorption oscillator strengths (f-values) for transitions out of the ground level of Fe II to the Z(sup 4)D(sup 0 sub 7/2) and z(sup 4)F(sup 0 sub 9/2) levels at 224.918 and 226.008 nm (air wavelengths) to be 0.00182(14) and 0.00244(19), respectively. The number in parenthesis is the uncertainty in the last digits. These two lines are important for studying Fe abundances and grain depletions in the interstellar medium. These f-values are determined by combining emission branching fractions with radiative lifetimes. Branching fractions are measured using classical spectroradiometry on an optically thin source. Radiative lifetimes are from the literature.

Bergeson, S. D.↗

Advanced Orion Optimized Laser System Analysis

Contractor shall perform a complete analysis of the potential of the solid state laser in the very long pulse mode (100 ns pulse width, 10-30 hz rep-rate) and in the very short pulse mode (100 ps pulse width 10-30 hz rep rate) concentrating on the operation of the device in the 'hot-rod' mode, where no active cooling the laser operation is attempted. Contractor's calculations shall be made of the phase aberrations which develop during the repped-pulse train, and the results shall feed into the adaptive optics analyses. The contractor shall devise solutions to work around ORION track issues. A final report shall be furnished to the MSFC COTR including all calculations and analysis of estimates of bulk phase and intensity aberration distribution in the laser output beam as a function of time during the repped-pulse train for both wave forms (high-energy/long-pulse, as well as low-energy/short-pulse). Recommendations shall be made for mitigating the aberrations by laser re-design and/or changes in operating parameters of optical pump sources and/or designs.

Source record↗

Analysis of Optimum Heterodyne Receivers for Coherent Lidar Applications

A full analysis of the combined effects of all the noise sources of optical heterodyne receiver and the interaction between the competing control parameters of the receiver detector and pre-amplifier will be presented. This analysis provides the mean for true optimization of the coherent lidar receiver. The significance of the optimization of heterodyne receiver is shown for 2-micron coherent lidar.

Amzajerdian, Farzin↗

Compact Video Microscope Imaging System Implemented in Colloid Studies

Long description Photographs showing fiber-optic light source, microscope and charge-coupled discharge (CCD) camera head connected to camera body, CCD camera body feeding data to image acquisition board in PC, and Cartesian robot controlled via PC board. The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. CMIS can be used in situ with a minimum amount of user intervention. This system can scan, find areas of interest in, focus on, and acquire images automatically. Many multiple-cell experiments require microscopy for in situ observations; this is feasible only with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control. The software also has a user-friendly interface, which can be used independently of the hardware for further post-experiment analysis. CMIS has been successfully developed in the SML Laboratory at the NASA Glenn Research Center and adapted for use for colloid studies and is available for telescience experiments. The main innovations this year are an improved interface, optimized algorithms, and the ability to control conventional full-sized microscopes in addition to compact microscopes. The CMIS software-hardware interface is being integrated into our SML Analysis package, which will be a robust general-purpose image-processing package that can handle over 100 space and industrial applications.

McDowell, Mark↗

JSC Orbital Debris Website Description

Purpose: The website provides information about the NASA Orbital Debris Program Office at JSC, which is the lead NASA center for orbital debris research. It is recognized world-wide for its leadership in addressing orbital debris issues. The NASA Orbital Debris Program Office has taken the international lead in conducting measurements of the environment and in developing the technical consensus for adopting mitigation measures to protect users of the orbital environment. Work at the center continues with developing an improved understanding of the orbital debris environment and measures that can be taken to control its growth. Major Contents: Orbital Debris research is divided into the following five broad efforts. Each area of research contains specific information as follows: 1) Modeling - NASA scientists continue to develop and upgrade orbital debris models to describe and characterize the current and future debris environment. Evolutionary and engineering models are described in detail. Downloadable items include a document in PDF format and executable software. 2) Measurements - Measurements of near-Earth orbital debris are accomplished by conducting ground-based and space-based observations of the orbital debris environment. The data from these sources provide validation of the environment models and identify the presence of new sources. Radar, optical and surface examinations are described. External links to related topics are provided. 3) Protection - Orbital debris protection involves conducting hypervelocity impact measurements to assess the risk presented by orbital debris to operating spacecraft and developing new materials and new designs to provide better protection from the environment with less weight penalty. The data from this work provides the link between the environment defined by the models and the risk presented by that environment to operating spacecraft and provides recommendations on design and operations procedures to reduce the risk as required. These data also help in the analysis and interpretation of impact features on returned spacecraft surfaces. 4) Mitigation - Controlling the growth of the orbital debris population is a high priority for NASA, the United States, and the major space-faring nations of the world to preserve near-Earth space for future generations. Mitigation measures can take the form of curtailing or preventing the creation of new debris, designing satellites to withstand impacts by small debris, and implementing operational procedures ranging from utilizing orbital regimes with less debris, adopting specific spacecraft attitudes, and even maneuvering to avoid collisions with debris. Downloadable items include several documents in PDF format and executable software.and 5) Reentry - Because of the increasing number of objects in space, NASA has adopted guidelines and assessment procedures to reduce the number of non-operational spacecraft and spent rocket upper stages orbiting the Earth. One method of postmission disposal is to allow reentry of these spacecraft, either from orbital decay (uncontrolled entry) or with a controlled entry. Orbital decay may be achieved by firing engines to lower the perigee altitude so that atmospheric drag will eventually cause the spacecraft to enter. However, the surviving debris impact footprint cannot be guaranteed to avoid inhabited landmasses. Controlled entry normally occurs by using a larger amount of propellant with a larger propulsion system to drive the spacecraft to enter the atmosphere at a steeper flight path angle. It will then enter at a more precise latitude, longitude, and footprint in a nearly uninhabited impact region, generally located in the ocean.

Johnson, Nicholas L.↗

Stabilizing an optoelectronic microwave oscillator with photonic filters

This paper compares methods of active stabilization of an optoelectronic microwave oscillator (OEO) based on insertion of a source of optical group delay into an OEO loop. The performance of an OEO stabilized with either a high- optical cavity or an atomic cell is analyzed. We show that the elements play a role of narrow-band microwave filters improving an OEO stability.

Atomic clocks electromagnetically induced transpar↗

Absolute Distance Measurement with the MSTAR Sensor

The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. The sensor uses a single laser in conjunction with fast phase modulators and low frequency detectors. We describe the design of the system - the principle of operation, the metrology source, beamlaunching optics, and signal processing - and show results for target distances up to 1 meter. We then demonstrate how the system can be scaled to kilometer-scale distances.

modulation sideband technology for absolute rangin↗

Methods and systems for detection of ice formation on surfaces

A system for detecting ice formation on metal, painted metal and other material surfaces can include a transparent window having an exterior surface upon which ice can form; a light source and optics configured and arranged to illuminate the exterior surface of the window from behind the exterior surface; and a detector and optics configured and arranged to receive light backscattered by the exterior surface and any ice disposed on the exterior surface and determine the thickness of the ice layer. For example, the system can be used with aircraft by placing one or more windows in the wings of the aircraft. The system is used for a novel optical method for real-time on-board detection and warning of ice formation on surfaces of airplanes, unmanned aerial vehicles (UAVs), and other vehicles and stationary structures to improve their safety and operation.

Alfano, Robert R.↗

Measurement and Calibration of PSD with Phase-shifting Interferometers

We discuss the instrumental aspects affecting the measurement accuracy when determining PSD with phase shifting interferometers. These include the source coherence, optical train effects, and detector effects. The use of a carefully constructed calibration standard will also be discussed. We will end with a recommended measurement and data handling procedure.

Lehan, J. P.↗

Evaluation of Carbon Dioxide Sensors for the Constellation Space Suit Life Support System for Surface Exploration

This paper presents the findings of the trade study to evaluate carbon dioxide (CO2) sensing technologies for the Constellation (Cx) space suit life support system for surface exploration. The trade study found that nondispersive infrared absorption (NDIR) is the most appropriate high Technology Readiness Level (TRL) technology for the CO2 sensor for the Cx space suit. The maturity of the technology is high, as it is the basis for the CO2 sensor in the Extravehicular Mobility Unit (EMU). The study further determined that while there is a range of commercial sensors available, the Cx CO2 sensor should be a new design. Specifically, there are light sources (e.g., infrared light emitting diodes) and detectors (e.g., cooled detectors) that are not in typical commercial sensors due to cost. These advanced technology components offer significant advantages in performance (weight, volume, power, accuracy) to be implemented in the new sensor. The exact sensor design (light source, transmitting optics, path length, receiving optics and detector) will be specific for the Cx space suit and will be determined by the performance requirements of the Cx space suit. The paper further identifies specifications for some of the critical performance parameters as well as discussing the engineering aspects of implementing the sensor into the Portable Life Support System (PLSS). The paper then presents testing results from three CO2 sensors with respect to issues important to Extravehicular Activity (EVA) applications; stability, humidity dependence and low pressure compatibility. The three sensors include two NDIR sensors, one commercial and one custom-developed by NASA (for a different purpose), and one commercial electrochemical sensor. The results show that both NDIR sensors have excellent stability, no dependence on ambient humidity (when the ambient temperature is above the dew point) and operate in low pressure conditions and after being exposed to a full vacuum. The commercial electrochemical sensor was not suitable for the Cx space suit for surface exploration. Finally, the paper identifies a number of techniques currently under development that offer significant advantages for EVA applications. These include miniaturized, room temperature, solid electrolyte systems and advanced optical detectors.

Dietrich, Daniel L.↗