Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Investigating the Response and Expansion of Plasma Plumes in a Mesosonic Plasma Using the Situational Awareness Sensor Suite for the ISS (SASSI)

To study the complex interactions between the space environment surrounding the International Space Station (ISS) and the ISS space vehicle, we are exploring a specialized suite of plasma sensors, manipulated by the Space Station Remote Manipulator System (SSRMS) to probe the near‐ISS mesosonic plasma ionosphere moving past the ISS. It is proposed that SASSI consists of the NASA Marshall Space Flight Center's (MSFC's) Thermal Ion Capped Hemispherical Spectrometer (TICHS), Thermal Electron Capped Hemispherical Spectrometer (TECHS), Charge Analyzer Responsive to Local Oscillations (CARLO), the Collimated PhotoElectron Gun (CPEG), and the University of Michigan Advanced Langmuir Probe (ALP). There are multiple expected applications for SASSI. Here, we will discuss the study of fundamental plasma physics questions associated with how an emitted plasma plume (such as from the ISS Plasma Contactor Unit (PCU)) responds and expands in a mesosonic magnetoplasma as well as emit and collect current. The ISS PCU Xe plasma plume drifts through the ionosphere and across the Earth's magnetic field, resulting in complex dynamics. This is of practical and theoretical interest pertaining to contamination concerns (e.g. energetic ion scattering) and the ability to collect and emit current between the spacecraft and the ambient plasma ionosphere. This impacts, for example, predictions of electrodynamic tether current performance using plasma contactors as well as decisions about placing high‐energy electric propulsion thrusters on ISS. We will discuss the required measurements and connection to proposed instruments for this study.

Gilchrist, Brian E.↗

Discharge Chamber Performance of the NEXIS Ion Thruster

The Nuclear-Electric Xenon Ion System (NEXIS) thruster was designed to produce greater than or equal to 70% efficiency at ISPs in excess of 6500 sec and total power levels in excess of 15 kW. In order to achieve this performance, the thruster requires a large area plasma generator capable of high propellant utilimtion efficiency and low discharge loss while producing a very flat, uniform beam profile. Fortunately, larger thrusters can be made more uniform and efficient due to the higher volume to surface ratio, provided that the magnetic cusp confinement is designed properly and the thruster length to diameter ratio is adequate. This paper describes the discharge chamber performance of the NEXIS Laboratory Model (LM) thruster. The LM discharge chamber is 65 cm in diameter at the grid plane and uses 6 ring-cusps to provide magnetic confinement of the plasma. The thruster was tested with flat carbon-carbon composite grids with the hole pattern masked to 57 cm in diameter and a conventional Type-B "1/2" diameter hollow cathode. During the preliminary "discharge only" tests, the LM thruster demonstrated profile factors of 0.84 and a discharge loss of about 160 eV/ion at 25 V discharge voltage and over 90% propellant utilization efficiency in simulated beam extraction experiments at 3.9 A of beam current. Analysis of the data from these tests used the discharge-only model developed by Brophy. Subsequent beam extraction experiments validated the key variables used in the model to predict the performance from the discharge-only data, and demonstrated 3.9 A of beam current at over 90% propellant utilization efficiency with a flatness parameter of better than 0.8 and a discharge loss of about 185 eV/ion. The slightly higher discharge loss measured during beam extractions was found to be due to a lower screen transparency in the as-manufactured LM grid set. Plasma measurements with a scanning probe internal to the thruster near the screen grid showed plasma densities over l x 10(exp 11) per cubic centimeter and electron temperatures of 3.5 to 5.5 eV depending on the operation parameters. The performance of the NEXIS discharge chamber contributed to the over 78% thruster efficiency measured during beam extraction at 7500 sec ISP and 25 kW of power, and over 81% thruster efficiency measured at 8500 sec ISP.

plasma generation↗

Measurements of plasma parameters in the vicinity of the Space Shuttle

A Langmuir probe flown as part of the Plasma Diagnostics Package aboard the third Space Shuttle flight was used to determine electron densities, temperatures, and plasma potential in the vicinity of the Shuttle Orbiter. Measurements taken both in the cargo bay and 10 m above the cargo bay on the Remote Manipulator System arm are consistent with small satellite and laboratory results, in that reduced densities and elevated temperatures are observed in the Shuttle wake. The primary difference in the Shuttle measurements is one of magnitude; i.e., orders-of-magnitude density decreases and factor-of-five temperature enhancements. Analysis of data taken in (Delta N)/N turbulence can be as high as a few percent, and the most intense turbulence seems to occur near regions with a steep gradient in plasma pressure.

Murphy, G.↗

The Fixed-Bias Langmuir Probe on the Communication-Navigation Outage Forecast System Satellite: Calibration and Validation

A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasma density is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future fixed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.

Vector Electric Field Instrument↗

Numerical simulation of a disk-shaped electron accelerating electrostatic probe

This paper presents a method utilizing the numerical plasma simulation particle-in-cell technique for studying electron accelerating probe characteristics. A probe configuration other than the commonly used plane, cylindrical, or spherical case will be studied; the probe configuration used is that of a disk. Cylindrical geometry is used in the simulation model. One of the advantages of a numerical simulation is the ease with which the details of the system can be examined. Therefore, in addition to the current-voltage characteristics of the static probe, other results are presented such as the time evolution of the plasma properties and studies of the sheath region surrounding the probe.

Nonnast, J. H.↗

Propagation of charge-exchange plasma produced by an ion thruster

Under the proper conditions there is an end-effect of a long, cylindrical Langmuir probe which allows a significant increase in collected ion current when the probe is aligned with a flowing plasma. This effect was used to determine the charge-exchange plasma flow direction at various locations relative to the ion thruster. The ion current collected by the probe as a function of its angle with respect to the plasma flow allows determination of the plasma density and plasma flow velocity at the probe's location upstream of the ion thruster optics. The density values obtained from the ion current agreed to within a factor of two of density values obtained by typical voltage-current Langmuir probe characteristics.

Carruth, M. R., Jr.↗

Survey of the Frequency Dependent Latitudinal Distribution of the Fast Magnetosonic Wave Mode from Van Allen Probes Electric and Magnetic Field Instrument and Integrated Science Waveform Receiver Plasma Wave Analysis

We present a statistical survey of the latitudinal structure of the fast magnetosonic wave mode detected by the Van Allen Probes spanning the time interval of 21 September 2012 to 1 August 2014. We show that statistically, the latitudinal occurrence of the wave frequency (f) normalized by the local proton cyclotron frequency (f(sub cP)) has a distinct funnel-shaped appearance in latitude about the magnetic equator similar to that found in case studies. By comparing the observed E/B ratios with the model E/B ratio, using the observed plasma density and background magnetic field magnitude as input to the model E/B ratio, we show that this mode is consistent with the extra-ordinary (whistler) mode at wave normal angles (theta(sub k)) near 90 deg. Performing polarization analysis on synthetic waveforms composed from a superposition of extra-ordinary mode plane waves with theta(sub k) randomly chosen between 87 and 90 deg, we show that the uncertainty in the derived wave normal is substantially broadened, with a tail extending down to theta(sub k) of 60 deg, suggesting that another approach is necessary to estimate the true distribution of theta(sub k). We find that the histograms of the synthetically derived ellipticities and theta(sub k) are consistent with the observations of ellipticities and theta(sub k) derived using polarization analysis.We make estimates of the median equatorial theta(sub k) by comparing observed and model ray tracing frequency-dependent probability occurrence with latitude and give preliminary frequency dependent estimates of the equatorial theta(sub k) distribution around noon and 4 R(sub E), with the median of approximately 4 to 7 deg from 90 deg at f/f(sub cP) = 2 and dropping to approximately 0.5 deg from 90 deg at f/f(sub cP) = 30. The occurrence of waves in this mode peaks around noon near the equator at all radial distances, and we find that the overall intensity of these waves increases with AE*, similar to findings of other studies.

Boardsen, Scott A.↗

Quiet-time plasma irregularities at 1400 km in the cleft region

The quiet north polar cleft at 1400 km was studied by Isis-2 instruments, and data from the retarding potential analyzer and the cylindrical electrostatic probe show that thermal plasma density fluctuations are distributed in a region between 75 deg and 82 deg invariant latitude and approximately dawn to dusk. Cleft shape and shape variations are described. Thermal ions and thermal electrons usually fluctuated together, but suprathermal electrons fluctuated independently. Data on thermal plasma patterns correlates fairly well with observations of soft particles and auroral optical emissions and not as well with measurements of high-energy particles. The data suggest that the energy source for the thermal irregularities is associated with soft particles and that precipitating high-energy particles do not drive the thermal plasma at these altitudes.

Kayser, S. E.↗

Space Shuttle Orbiter charging

This paper considers the charging of the Space Shuttle Orbiter by energetic particles of environmental origin and from emission by accelerators. The results indicate that precipitating electrons quickly induce large voltages. High voltages may also occur when onboard accelerators inject energetic beams into the high altitude plasma. A significant conclusion from electron beam experiments is that the rockets charged to positive potentials much less than anticipated from the theory of probes in a quiescent plasma. Elementary theories predict the large negative potentials observed by firing energetic ions and predict severe differential charging of the Orbiter.

Katz, I.↗

A Particle and Energy Balance Model of the Orificed Hollow Cathode

A particle and energy balance model of orificed hollow cathodes was developed to assist in cathode design. The model presented here is an ensemble of original work by the author and previous work by others. The processes in the orifice region are considered to be one of the primary drivers in determining cathode performance, since the current density was greatest in this volume (up to 1.6 x 10(exp 8) A/m2). The orifice model contains comparatively few free parameters, and its results are used to bound the free parameters for the insert model. Next, the insert region model is presented. The sensitivity of the results to the free parameters is assessed, and variation of the free parameters in the orifice dominates the calculated power consumption and plasma properties. The model predictions are compared to data from a low-current orificed hollow cathode. The predicted power consumption exceeds the experimental results. Estimates of the plasma properties in the insert region overlap Langmuir probe data, and the predicted orifice plasma suggests the presence of one or more double layers. Finally, the model is used to examine the operation of higher current cathodes.

Domonkos, Matthew T.↗

Electron temperature and concentration in a thermal atomic oxygen source

A thermal atomic oxygen source for materials screening was built for NASA by Boeing Aerospace. The objective here was to use a microwave interferometer and Langmuir probe to characterize the electron concentration in this thermal atomic oxygen source. Typical operating conditions in the thermal atomic oxygen source were found to produce electron concentrations that were well below the detection threshold of the interferometer (10(exp 8) cm (sup -3)). The researchers calibrated (with the interferometer) the Langmuir probe at an artificially high plasma density and then used the circular and the square Langmuir probes to measure the low electron concentrations that exist during materials exposure tests. Electron concentration was measured as a function of power and position. The electrons were lost to the walls through ambipolar diffusion, and their concentration was accurately described by an equation. The electron concentration was proportional to power squared and decayed exponentially with distance.

Pedrow, Patrick Dennis↗

Initial Results from the Floating Potential Measurement Unit aboard the International Space Station

The Floating Potential Measurement Unit (FPMU) is a multi-probe package designed to measure the floating potential of the 1nternational Space Station (ISS) as well as the density and temperature of the local ionospheric plasma environment. The role oj the FPMU is to provide direct measurements of ISS spacecraft charging as continuing construction leads to dramatic changes in ISS size and configuration. FPMU data are used for refinement and validation of the ISS spacecraft charging models used to evaluate the severity and frequency of occurrence of ISS charging hazards. The FPMU data and the models are also used to evaluate the effectiveness of proposed hazard controls. The FPMU consists of four probes: a floating potential probe, two Langmuir probes. and a plasma impedance probe. These probes measure the floating potential of the ISS, plasma density, and electron temperature. Redundant measurements using different probes support data validation by inter-probe comparisons. The FPMU was installed by ISS crewmembers, during an ExtraVehicular Activity, on the starboard (Sl) truss of the ISS in early August 2006, when the ISS incorporated only one 160V US photovoltaic (PV) array module. The first data campaign began a few hours after installation and continued for over five days. Additional data campaigns were completed in 2007 after a second 160V US PV array module was added to the ISS. This paper discusses the general performance characteristics of the FPMU as integrated on ISS, the functional performance of each probe, the charging behavior of the ISS before and after the addition of a second 160V US PV array module, and initial results from model comparisons.

Wright, Kenneth H., Jr.↗

The day side mid-latitude plasma trough

Above 2500 km the electrostatic probe experiment aboard the Isis 1 satellite detects a persistent dayside midlatitude plasma trough. The superposition of measurements taken over two-week intervals at noon is used to illustrate the form and location of the quiet time trough within each season. These measurement results contrast with those observations of a less prominent dayside trough at altitudes below 2500 km. Associated with the trough above 2500 km is an electron temperature maximum of about 6000 K that is sharp at midnight and broad at noon. In spring and summer a second noontime temperature maximum often appears poleward of 70-deg invariant latitude accompanied by an enhancement in the ionization. When it is assumed that the geophysical processes producing a plasmasphere act most directly upon the light ions, one factor contributing to the distinction between the plasma trough and the equatorial plasmapause is the increasing influence of O(+) on total plasma behavior at lower altitudes. Other factors are the local processes, such as dayside F region photoionization by energetic cusp particles that produce enhancements in plasma density and electron temperature.

Miller, N.↗

Material injection alleviation and plasma diagnostic measurements during the RAM C-III flight.

The results of a material injection RF blackout alleviation experiment and of plasma diagnostic measurements using electrostatic probes and an S-band reflectometer in a 25,000 ft/sec reentry flight are presented. Significant alleviation of RF blackout is observed at altitudes of from 270,000 feet to 120,000 feet due to injection of water and Freon E-3 on VHF, S-band, C-band, and X-band frequencies. Electrostatic probe data, attenuation data, and S-band diagnostic data show consistent plasma results. The relative effectiveness of water and Freon E-3 is discussed.

Schroeder, L. C.↗

Persistent Longitudinal Variations of Plasma Density and DC Electric Fields in the Low Latitude Ionosphere Observed with Probes on the C/NOFS Satellite

Continuous measurements using in situ probes on consecutive orbits of the C/N0FS satellite reveal that the plasma density is persistently organized by longitude, in both day and night conditions and at all locations within the satellite orbit, defined by its perigee and apogee of 401 km and 867 km, respectively, and its inclination of 13 degrees. Typical variations are a factor of 2 or 3 compared to mean values. Furthermore, simultaneous observations of DC electric fields and their associated E x B drifts in the low latitude ionosphere also reveal that their amplitudes are also strongly organized by longitude in a similar fashion. The drift variations with longitude are particularly pronounced in the meridional component perpendicular to the magnetic field although they are also present in the zonal component as well. The longitudes of the peak meridional drift and density values are significantly out of phase with respect to each other. Time constants for the plasma accumulation at higher altitudes with respect to the vertical drift velocity must be taken into account in order to properly interpret the detailed comparisons of the phase relationship of the plasma density and plasma velocity variations. Although for a given period corresponding to that of several days, typically one longitude region dominates the structuring of the plasma density and plasma drift data, there is also evidence for variations organized about multiple longitudes at the same time. Statistical averages will be shown that suggest a tidal "wave 4" structuring is present in both the plasma drift and plasma density data. We interpret the apparent association of the modulation of the E x B drifts with longitude as well as that of the ambient plasma density as a manifestation of tidal forces at work in the low latitude upper atmosphere. The observations demonstrate how the high duty cycle of the C/NOFS observations and its unique orbit expose fundamental processes at work in the low latitude, inner regions of geospace.

Pfaff, R.↗