Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Margin Evaluation in the Presence of Deformation, Rotation, and Translation in Prostate and Entire Seminal Vesicle Irradiation With Daily Marker-Based Setup Corrections

Purpose: To develop a method for margin evaluation accounting for all measured displacements during treatment of prostate cancer. Methods and Materials: For 21 patients treated with stereographic targeting marker-based online translation corrections, dose distributions with varying margins and gradients were created. Sets of possible cumulative delivered dose distributions were simulated by moving voxels and accumulating dose per voxel. Voxel motion was simulated consistent with measured distributions of systematic and random displacements due to stereographic targeting inaccuracies, deformation, rotation, and intrafraction motion. The method of simulation maintained measured correlation of voxel motions due to organ deformation. Results: For the clinical target volume including prostate and seminal vesicles (SV), the probability that some part receives <95% of the prescribed dose, the changes in minimum dose, and volume receiving 95% of prescription dose compared with planning were 80.5% {+-} 19.2%, 9.0 {+-} 6.8 Gy, and 3.0% {+-} 3.7%, respectively, for the smallest studied margins (3 mm prostate, 5 mm SV) and steepest dose gradients. Corresponding values for largest margins (5 mm prostate, 8 mm SV) with a clinical intensity-modulated radiotherapy dose distribution were 46.5% {+-} 34.7%, 6.7 {+-} 5.8 Gy, and 1.6% {+-} 2.3%. For prostate-only clinical target volume, the values were 51.8% {+-} 17.7%, 3.3 {+-} 1.6 Gy, and 0.6% {+-} 0.5% with the smallest margins and 5.2% {+-} 7.4%, 1.8 {+-} 0.9 Gy, and 0.1% {+-} 0.1% for the largest margins. Addition of three-dimensional rotation corrections only improved these values slightly. All rectal planning constraints were met in the actual reconstructed doses for all studied margins. Conclusion: We developed a system for margin validation in the presence of deformations. In our population, a 5-mm margin provided sufficient dosimetric coverage for the prostate. In contrast, an 8-mm SV margin was still insufficient owing to deformations. Addition of three-dimensional rotation corrections was of minor influence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography-defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis-free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CT and MR-CT Fusion for Prostate Post-Implant Dosimetry

Purpose: The use of T2 MR for postimplant dosimetry (PID) after prostate brachytherapy allows more anatomically accurate and precise contouring but does not readily permit seed identification. We developed a reproducible technique for performing MR-CT fusion and compared the resulting dosimetry to standard CT-based PID. Methods and Materials: CT and T1-weighted MR images for 45 patients were fused and aligned based on seed distribution. The T2-weighted MR image was then fused to the aligned T1. Reproducibility of the fusion technique was tested by inter- and intraobserver variability for 13 patients. Dosimetry was computed for the prostate as a whole and for the prostate divided into anterior and posterior sectors of the base, mid-prostate, and apex. Results: Inter- and intraobserver variability for the fusion technique showed less than 1% variation in D90. MR-CT fusion D90 and CT D90 were nearly equivalent for the whole prostate, but differed depending on the identification of superior extent of the base (p = 0.007) and on MR/CT prostate volume ratio (p = 0.03). Sector analysis showed a decrease in MR-CT fusion D90 in the anterior base (ratio 0.93 {+-}0.25, p < 0.05) and an increase in MR-CT fusion D90 in the apex (p < 0.05). The volume of extraprostatic tissue encompassed by the V100 is greater on MR than CT. Factors associated with this difference are the MR/CT volume ratio (p < 0.001) and the difference in identification of the inferior extent of the apex (p = 0.03). Conclusions: We developed a reproducible MR-CT fusion technique that allows MR-based dosimetry. Comparing the resulting postimplant dosimetry with standard CT dosimetry shows several differences, including adequacy of coverage of the base and conformity of the dosimetry around the apex. Given the advantage of MR-based tissue definition, further study of MR-based dosimetry is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior-inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT-contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Race and Survival Following Brachytherapy-Based Treatment for Men With Localized or Locally Advanced Adenocarcinoma of the Prostate

Purpose: We investigated whether race was associated with risk of death following brachytherapy-based treatment for localized prostate cancer, adjusting for age, cardiovascular comorbidity, treatment, and established prostate cancer prognostic factors. Methods: The study cohort was composed of 5,360 men with clinical stage T1-3N0M0 prostate cancer who underwent brachytherapy-based treatment at 20 centers within the 21st Century Oncology consortium. Cox regression multivariable analysis was used to evaluate the risk of death in African-American and Hispanic men compared to that in Caucasian men, adjusting for age, pretreatment prostate-specific antigen (PSA) level, Gleason score, clinical T stage, year and type of treatment, median income, and cardiovascular comorbidities. Results: After a median follow-up of 3 years, there were 673 deaths. African-American and Hispanic races were significantly associated with an increased risk of all-cause mortality (ACM) (adjusted hazard ratio, 1.77 and 1.79; 95% confidence intervals, 1.3-2.5 and 1.2-2.7; p < 0.001 and p = 0.005, respectively). Other factors significantly associated with an increased risk of death included age (p < 0.001), Gleason score of 8 to 10 (p = 0.04), year of brachytherapy (p < 0.001), and history of myocardial infarction treated with stent or coronary artery bypass graft (p < 0.001). Conclusions: After adjustment for prostate cancer prognostic factors, age, income level, and revascularized cardiovascular comorbidities, African-American and Hispanic races were associated with higher ACM in men with prostate cancer. Additional causative factors need to be identified.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Choline Levels From 3-Tesla MR Spectroscopy After Exclusive Radiation Therapy in Patients With Clinically Localized Prostate Cancer are Predictive of Plasmatic Levels of PSA at 1 Year

Purpose: To investigate the time course response of prostate metabolism to irradiation using magnetic resonance spectroscopy (MRS) at 3-month intervals and its impact on biochemical control. Methods and Materials: Between January 2008 and April 2010, 24 patients with localized prostate cancer were prospectively enrolled in the Evaluation of the Response to Irradiation with MR Spectroscopy (ERIS) trial. All the patients had been treated with intensity-modulated radiation therapy with or without long-term adjuvant hormonal therapy (LTHT) and underwent 3-T MRS and prostate-specific antigen (PSA) assays at baseline and every 3 months thereafter up to 12 months. Results: After radiation, the mean normalized citrate level (citrate/water) decreased significantly over time, both in the peripheral zone (PZ) (p = 0.0034) and in the entire prostate (p = 0.0008), whereas no significant change was observed in mean normalized choline levels (choline/water) in the PZ (p = 0.84) and in the entire prostate (p = 0.95). At 6 months after radiation, the mean choline level was significantly lower in the PZ for patients with a PSA value of {<=}0.5 ng/mL at 12 months (4.9 {+-} 1.7 vs. 7.1 {+-} 1.5, p = 0.0378). Similar results were observed at 12 months in the PZ (6.2 {+-} 2.3 vs. 11.4 {+-} 4.1, p = 0.0117 for choline level and 3.4 {+-} 0.7 vs. 16.1 {+-} 6.1, p = 0.0054 for citrate level) and also in the entire prostate (6.2 {+-} 1.9 vs. 10.4 {+-} 3.2, p = 0.014 for choline level and 3.0 {+-} 0.8 vs. 13.3 {+-} 4.7, p = 0.0054 for citrate level). For patients receiving LTHT, there was no correlation between choline or citrate levels and PSA value, either at baseline or at follow-up. Conclusions: Low normalized choline in the PZ, 6 months after radiation, predicts which patients attained a PSA {<=}0.5 ng/mL at 1 year. Further analyses with longer follow-up times are warranted to determine whether or not these new biomarkers can conclusively predict the early radiation response and the clinical outcome for patients with or without LTHT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Intra- or Periprostatic Calcifications in Image-Guided Radiotherapy for Prostate Cancer

Purpose: Image-guided radiotherapy (IGRT) allows more precise localization of the prostate, thus minimizing errors resulting from organ motion and set-up during treatment of prostate cancer. Using megavoltage cone-beam computed tomography (MVCBCT), references such as bones, the prostate itself or implanted fiducial markers can be used as surrogates to correct patient positioning immediately before each treatment fraction. However, the use of fiducials requires an invasive procedure and may increase costs. We aimed to assess whether intra- or periprostatic calcifications (IPC) could be used as natural fiducials. Methods and Materials: Data on patients treated with IGRT for prostate cancer with clearly visible IPC and implanted fiducials in both planning CT and MVCBCT images were reviewed. IPC were classified as central when inside the prostate and peripheral when within the planning target volume. Daily deviations in lateral, longitudinal, and vertical directions from baseline positioning using fiducials and using IPC were compared. Results: A total of 287 MVCBCT images were obtained and analyzed from 10 patients. The mean {+-} standard deviation daily deviation (mm) in the lateral, longitudinal, and vertical coordinates were 0.55 {+-} 3.11, 0.58 {+-} 3.45, and -0.54 {+-} 4.03, respectively, for fiducials, and 0.72 {+-} 3.22, 0.63 {+-} 3.58, and -0.69 {+-} 4.26, for IPC. The p values for comparisons (fiducials vs. IPC) were 0.003, 0.653, and 0.078 for lateral, longitudinal, and vertical coordinates, respectively. When cases with central IPC were analyzed (n = 7), no significant difference was found in such comparisons. Central IPC and fiducials exhibited a similar pattern of displacement during treatment, with equal values for daily displacements in the three directions for more than 90% of measurements. Conclusions: Our data suggest that centrally located IPC may be used as natural fiducials for treatment positioning during IGRT for prostate cancer, with potential reductions in the risks and costs associated with fiducial implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypoxic Prostate/Muscle PO{sub 2} Ratio Predicts for Outcome in Patients With Localized Prostate Cancer: Long-Term Results

Purpose: To correlate tumor oxygenation status with long-term biochemical outcome after prostate brachytherapy. Methods and Materials: Custom-made Eppendorf PO{sub 2} microelectrodes were used to obtain PO{sub 2} measurements from the prostate (P), focused on positive biopsy locations, and normal muscle tissue (M), as a control. A total of 11,516 measurements were obtained in 57 men with localized prostate cancer immediately before prostate brachytherapy was given. The Eppendorf histograms provided the median PO{sub 2}, mean PO{sub 2}, and % <5 mm Hg or <10 mm Hg. Biochemical failure (BF) was defined using both the former American Society of Therapeutic Radiation Oncology (ASTRO) (three consecutive raises) and the current Phoenix (prostate-specific antigen nadir + 2 ng/mL) definitions. A Cox proportional hazards regression model evaluated the influence of hypoxia using the P/M mean PO{sub 2} ratio on BF. Results: With a median follow-up time of 8 years, 12 men had ASTRO BF and 8 had Phoenix BF. On multivariate analysis, P/M PO{sub 2} ratio <0.10 emerged as the only significant predictor of ASTRO BF (p = 0.043). Hormonal therapy (p = 0.015) and P/M PO{sub 2} ratio <0.10 (p = 0.046) emerged as the only independent predictors of the Phoenix BF. Kaplan-Meier freedom from BF for P/M ratio <0.10 vs. {>=}0.10 at 8 years for ASTRO BF was 46% vs. 78% (p = 0.03) and for the Phoenix BF was 66% vs. 83% (p = 0.02). Conclusions: Hypoxia in prostate cancer (low mean P/M PO{sub 2} ratio) significantly predicts for poor long-term biochemical outcome, suggesting that novel hypoxic strategies should be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Matched Cohort Analysis of Outcomes of Definitive Radiotherapy for Prostate Cancer in Human Immunodeficiency Virus-Positive Patients

Purpose: To compare the biochemical outcome and toxicity scores of men with human immunodeficiency virus (HIV) and prostate cancer with a matched control population with negative or unknown HIV status when treated with external-beam radiotherapy (EBRT). Methods and Materials: A single-institution database of men with prostate cancer treated with EBRT from 1999 to 2009 was reviewed. Thirteen men with HIV were identified and matched to 2 control patients according to age, race, T stage, prostate-specific antigen level, Gleason score, RT dose, intensity-modulated RT vs. three-dimensional conformal RT, and whole-pelvis vs. prostate-only RT, for a total of 39 cases. The median follow-up time was 39 months (range, 3-110 months). Results: The 4-year biochemical failure (BF)-free survival rate was 87% in the HIV-positive group vs. 89% in the controls (p = 0.94). Pre- and post-RT viral loads were found to be predictive of BF (p = 0.04 and p = 0.04, respectively). No men with HIV died, whereas 2 in the control group died of causes unrelated to prostate cancer. Acute and chronic genitourinary and gastrointestinal toxicity were less in the HIV-positive patients than in controls (p < 0.001, p < 0.001, p = 0.003, and p < 0.001, respectively). The HIV-positive men experienced an average decline in CD4 count of 193 cells/mm{sup 3}. Conclusions: Our findings suggest that men with HIV treated with EBRT have a similar risk of BF; however, high viral loads may contribute to an increased risk. This analysis supports that HIV-positive men with prostate cancer can be treated with definitive EBRT with similar disease control and toxicity outcomes as in the general population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Study to Quantify the Effectiveness of Daily Endorectal Balloon for Prostate Intrafraction Motion Management

Purpose: To quantify intrafraction prostate motion between patient groups treated with and without daily endorectal balloon (ERB) employed during prostate radiotherapy and establish the effectiveness of the ERB. Methods: Real-time intrafraction prostate motion from 29 non-ERB (1,061 sessions) and 30 ERB (1,008 sessions) patients was evaluated based on three-dimensional (3D), left, right, cranial, caudal, anterior, and posterior displacements. The average percentage of time with 3D and unidirectional prostate displacements >2, 3, 4, 5, 6, 7, 8, 9, and 10 mm in 1-min intervals was calculated for up to 6 min of treatment time. The Kolmogorov-Smirnov method was used to evaluate the intrafraction prostate motion pattern between both groups. Results: Large 3D motion (up to 1 cm or more) was only observed in the non-ERB group. The motion increased as a function of elapsed time for displacements >2-8 mm for the non-ERB group and >2-4 mm for the ERB group (p < 0.05). The percentage time distributions between the two groups were significantly different for motion >5 mm (p < 0.05). The 3D symmetrical internal margin (IM) can be reduced from 5 to 3 mm (40% reduction), whereas the asymmetrical IM can be reduced from 3 to 2 mm (33% reduction) in cranial, caudal, anterior, and posterior for 6 min of treatment, when ERB is used. Beyond 6 min, the symmetrical 3D and asymmetrical cranial, caudal, anterior, and posterior IMs can be reduced from 9, 4, 7, 7, and 8 to 5, 2, 5, 3, and 4 mm, respectively (up to 57% reduction). Conclusion: The percentage of time that the prostate was displaced in any direction was less in the ERB group for almost all magnitudes of motion considered. The directional analysis shows that the ERB reduced IMs in almost all directions, especially the anterior-posterior direction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Castration Therapy of Prostate Cancer Results in Downregulation of HIF-1{alpha} Levels

Background and Purpose: Neoadjuvant androgen deprivation in combination with radiotherapy of prostate cancer is used to improve radioresponsiveness and local tumor control. Currently, the underlying mechanism is not well understood. Because hypoxia causes resistance to radiotherapy, we wanted to test whether castration affects the degree of hypoxia in prostate cancer. Methods and Materials: In 14 patients with locally advanced prostate cancer, six to 12 prostatic needle core biopsy specimens were taken prior to castration therapy. Bilateral orchidectomy was performed in 7 patients, and 7 were treated with a GnRH-agonist (leuprorelin). After castrationm two to four prostatic core biopsy specimens were taken, and the level of hypoxia-inducible factor-1{alpha} (HIF-1{alpha}) in cancer was determined by immunofluorescence. Results: Among biopsy specimens taken before castration, strong HIF-1{alpha} expression (mean intensity above 30) was shown in 5 patients, weak expression (mean intensity 10-30) in 3 patients, and background levels of HIF-1{alpha} (mean intensity 0-10) in 6 patients. Downregulation of HIF-1{alpha} expression after castration was observed in all 5 patients with strong HIF-1{alpha} precastration expression. HIF-1{alpha} expression was also reduced in 2 of 3 patients with weak HIF-1{alpha} precastration expression. Conclusions: Our data suggest that neoadjuvant castration decreases tumor cell hypoxia in prostate cancer, which may explain increased radiosensitivity after castration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Image-based Monitoring of Soft-tissue Displacements for Radiation Therapy of the Prostate

Purpose: Emerging prolonged, hypofractionated radiotherapy regimens rely on high-dose conformality to minimize toxicity and thus can benefit from image guidance systems that continuously monitor target position during beam delivery. To address this need we previously developed, as a potential add-on device for existing linear accelerators, a novel telerobotic ultrasound system capable of real-time, soft-tissue imaging. Expanding on this capability, the aim of this work was to develop and characterize an image-based technique for real-time detection of prostate displacements. Methods and Materials: Image processing techniques were implemented on spatially localized ultrasound images to generate two parameters representing prostate displacements in real time. In a phantom and five volunteers, soft-tissue targets were continuously imaged with a customized robotic manipulator while recording the two tissue displacement parameters (TDPs). Variations of the TDPs in the absence of tissue displacements were evaluated, as was the sensitivity of the TDPs to prostate translations and rotations. Robustness of the approach to probe force was also investigated. Results: With 95% confidence, the proposed method detected in vivo prostate displacements before they exceeded 2.3, 2.5, and 2.8 mm in anteroposterior, superoinferior, and mediolateral directions. Prostate pitch was detected before exceeding 4.7 Degree-Sign at 95% confidence. Total system time lag averaged 173 ms, mostly limited by ultrasound acquisition rate. False positives (FPs) (FP) in the absence of displacements did not exceed 1.5 FP events per 10 min of continuous in vivo imaging time. Conclusions: The feasibility of using telerobotic ultrasound for real-time, soft-tissue-based monitoring of target displacements was confirmed in vivo. Such monitoring has the potential to detect small clinically relevant intrafractional variations of the prostate position during beam delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in Initial Treatment for Prostate Cancer Among Medicare Beneficiaries, 1999-2007

Purpose: In the absence of evidence from large clinical trials, optimal therapy for localized prostate cancer remains unclear; however, treatment patterns continue to change. We examined changes in the management of patients with prostate cancer in the Medicare population. Methods and Materials: We conducted a retrospective claims-based analysis of the use of radiation therapy, surgery, and androgen deprivation therapy in the 12 months after diagnosis of prostate cancer in a nationally representative 5% sample of Medicare claims. Patients were Medicare beneficiaries 67 years or older with incident prostate cancer diagnosed between 1999 and 2007. Results: There were 20,918 incident cases of prostate cancer between 1999 and 2007. The proportion of patients receiving androgen deprivation therapy decreased from 55% to 36%, and the proportion of patients receiving no active therapy increased from 16% to 23%. Intensity-modulated radiation therapy replaced three-dimensional conformal radiation therapy as the most common method of radiation therapy, accounting for 77% of external beam radiotherapy by 2007. Minimally invasive radical prostatectomy began to replace open surgical approaches, being used in 49% of radical prostatectomies by 2007. Conclusions: Between 2002 and 2007, the use of androgen deprivation therapy decreased, open surgical approaches were largely replaced by minimally invasive radical prostatectomy, and intensity-modulated radiation therapy replaced three-dimensional conformal radiation therapy as the predominant method of radiation therapy in the Medicare population. The aging of the population and the increasing use of newer, higher-cost technologies in the treatment of patients with prostate cancer may have important implications for nationwide health care costs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Bed Motion During Intensity-Modulated Radiotherapy Treatment

Purpose: Conformal radiation therapy in the postprostatectomy setting requires accurate setup and localization of the prostatic fossa. In this series, we report prostate bed localization and motion characteristics, using data collected from implanted radiofrequency transponders. Methods and Materials: The Calypso four-dimensional localization system uses three implanted radiofrequency transponders for daily target localization and real-time tracking throughout a course of radiation therapy. We reviewed the localization and tracking reports for 20 patients who received ultrasonography-guided placement of Calypso transponders within the prostate bed prior to a course of intensity-modulated radiation therapy at Fox Chase Cancer Center. Results: At localization, prostate bed displacement relative to bony anatomy exceeded 5 mm in 9% of fractions in the anterior-posterior (A-P) direction and 21% of fractions in the superior-inferior (S-I) direction. The three-dimensional vector length from skin marks to Calypso alignment exceeded 1 cm in 24% of all 652 fractions with available setup data. During treatment, the target exceeded the 5-mm tracking limit for at least 30 sec in 11% of all fractions, generally in the A-P or S-I direction. In the A-P direction, target motion was twice as likely to move posteriorly, toward the rectum, than anteriorly. Fifteen percent of all treatments were interrupted for repositioning, and 70% of patients were repositioned at least once during their treatment course. Conclusion: Set-up errors and motion of the prostatic fossa during radiotherapy are nontrivial, leading to potential undertreatment of target and excess normal tissue toxicity if not taken into account during treatment planning. Localization and real-time tracking of the prostate bed via implanted Calypso transponders can be used to improve the accuracy of plan delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Clinical Outcomes With High-Dose Image Guided Radiotherapy Compared With Non-IGRT for the Treatment of Clinically Localized Prostate Cancer

Purpose: To compare toxicity profiles and biochemical tumor control outcomes between patients treated with high-dose image-guided radiotherapy (IGRT) and high-dose intensity-modulated radiotherapy (IMRT) for clinically localized prostate cancer. Materials and Methods: Between 2008 and 2009, 186 patients with prostate cancer were treated with IGRT to a dose of 86.4 Gy with daily correction of the target position based on kilovoltage imaging of implanted prostatic fiducial markers. This group of patients was retrospectively compared with a similar cohort of 190 patients who were treated between 2006 and 2007 with IMRT to the same prescription dose without, however, implanted fiducial markers in place (non-IGRT). The median follow-up time was 2.8 years (range, 2-6 years). Results: A significant reduction in late urinary toxicity was observed for IGRT patients compared with the non-IGRT patients. The 3-year likelihood of grade 2 and higher urinary toxicity for the IGRT and non-IGRT cohorts were 10.4% and 20.0%, respectively (p = 0.02). Multivariate analysis identifying predictors for grade 2 or higher late urinary toxicity demonstrated that, in addition to the baseline Internatinoal Prostate Symptom Score, IGRT was associated with significantly less late urinary toxicity compared with non-IGRT. The incidence of grade 2 and higher rectal toxicity was low for both treatment groups (1.0% and 1.6%, respectively; p = 0.81). No differences in prostate-specific antigen relapse-free survival outcomes were observed for low- and intermediate-risk patients when treated with IGRT and non-IGRT. For high-risk patients, a significant improvement was observed at 3 years for patients treated with IGRT compared with non-IGRT. Conclusions: IGRT is associated with an improvement in biochemical tumor control among high-risk patients and a lower rate of late urinary toxicity compared with high-dose IMRT. These data suggest that, for definitive radiotherapy, the placement of fiducial markers and daily tracking of target positioning may represent the preferred mode of external-beam radiotherapy delivery for the treatment of prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implanted Dosimeters Identify Radiation Overdoses During IMRT for Prostate Cancer

Purpose: Image-guided dose-escalated radiotherapy is the standard of care for the treatment of prostate cancer. Although many published methods are available that account for prostate motion during delivery, evidence demonstrating that the planned dose is actually delivered on a daily basis is lacking. We report our initial clinical experience using implantable dosimeters to quantify and adjust the dose received during intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients undergoing IMRT with cone-beam computed tomography (CT) image guidance for prostate cancer had the dose verification system with radiopaque metal-oxide-semiconductor field effect transistor dosimeters implanted before treatment planning. All patients underwent planning with CT simulation in the supine position with custom immobilization, and the implanted dosimeters were located in the IMRT plans. The predicted dose for each dosimeter was defined and compared with the wireless readings before and after each treatment session. Investigations by physicians and medical physicists were initiated for two or more discrepancies >6% for any five consecutive fractions or for any discrepancy {>=}10%. Results: Using implanted in vivo dosimeters, dose measurements consistently >6% greater than the predicted values were observed during treatment for 3 of 20 prostate cancer patients who received IMRT with daily image guidance. A review of the daily cone-beam CT images revealed acceptable alignment of the prostate target volumes and implanted dosimeters but identified significant anatomic changes within the treated region. Repeat CT simulation and RT planning was performed, with resolution of the dose discrepancies in all 3 cases with the adoption of a new IMRT plan. Conclusions: Our report illustrates the potential effect of implanted in vivo dosimetry for prostate IMRT and emphasizes the importance of careful planning and delivery with attention to systematic shifts or anatomic changes that could alter the dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity Modulated Radiation Therapy Dose Painting for Localized Prostate Cancer Using {sup 11}C-choline Positron Emission Tomography Scans

Purpose: To demonstrate the technical feasibility of intensity modulated radiation therapy (IMRT) dose painting using {sup 11}C-choline positron emission tomography PET scans in patients with localized prostate cancer. Methods and Materials: This was an RT planning study of 8 patients with prostate cancer who had {sup 11}C-choline PET scans prior to radical prostatectomy. Two contours were semiautomatically generated on the basis of the PET scans for each patient: 60% and 70% of the maximum standardized uptake values (SUV{sub 60%} and SUV{sub 70%}). Three IMRT plans were generated for each patient: PLAN{sub 78}, which consisted of whole-prostate radiation therapy to 78 Gy; PLAN{sub 78-90}, which consisted of whole-prostate RT to 78 Gy, a boost to the SUV{sub 60%} to 84 Gy, and a further boost to the SUV{sub 70%} to 90 Gy; and PLAN{sub 72-90}, which consisted of whole-prostate RT to 72 Gy, a boost to the SUV{sub 60%} to 84 Gy, and a further boost to the SUV{sub 70%} to 90 Gy. The feasibility of these plans was judged by their ability to reach prescription doses while adhering to published dose constraints. Tumor control probabilities based on PET scan-defined volumes (TCP{sub PET}) and on prostatectomy-defined volumes (TCP{sub path}), and rectal normal tissue complication probabilities (NTCP) were compared between the plans. Results: All plans for all patients reached prescription doses while adhering to dose constraints. TCP{sub PET} values for PLAN{sub 78}, PLAN{sub 78-90}, and PLAN{sub 72-90} were 65%, 97%, and 96%, respectively. TCP{sub path} values were 71%, 97%, and 89%, respectively. Both PLAN{sub 78-90} and PLAN{sub 72-90} had significantly higher TCP{sub PET} (P=.002 and .001) and TCP{sub path} (P<.001 and .014) values than PLAN{sub 78}. PLAN{sub 78-90} and PLAN{sub 72-90} were not significantly different in terms of TCP{sub PET} or TCP{sub path}. There were no significant differences in rectal NTCPs between the 3 plans. Conclusions: IMRT dose painting for localized prostate cancer using {sup 11}C-choline PET scans is technically feasible. Dose painting results in higher TCPs without higher NTCPs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical Results

Purpose: Most linear accelerators purchased today are equipped with a gantry-mounted kilovoltage X-ray imager which is typically used for patient imaging prior to therapy. A novel application of the X-ray system is kilovoltage intrafraction monitoring (KIM), in which the 3-dimensional (3D) tumor position is determined during treatment. In this paper, we report on the first use of KIM in a prospective clinical study of prostate cancer patients undergoing intensity modulated arc therapy (IMAT). Methods and Materials: Ten prostate cancer patients with implanted fiducial markers undergoing conventionally fractionated IMAT (RapidArc) were enrolled in an ethics-approved study of KIM. KIM involves acquiring kV images as the gantry rotates around the patient during treatment. Post-treatment, markers in these images were segmented to obtain 2D positions. From the 2D positions, a maximum likelihood estimation of a probability density function was used to obtain 3D prostate trajectories. The trajectories were analyzed to determine the motion type and the percentage of time the prostate was displaced {>=}3, 5, 7, and 10 mm. Independent verification of KIM positional accuracy was performed using kV/MV triangulation. Results: KIM was performed for 268 fractions. Various prostate trajectories were observed (ie, continuous target drift, transient excursion, stable target position, persistent excursion, high-frequency excursions, and erratic behavior). For all patients, 3D displacements of {>=}3, 5, 7, and 10 mm were observed 5.6%, 2.2%, 0.7% and 0.4% of the time, respectively. The average systematic accuracy of KIM was measured at 0.46 mm. Conclusions: KIM for prostate IMAT was successfully implemented clinically for the first time. Key advantages of this method are (1) submillimeter accuracy, (2) widespread applicability, and (3) a low barrier to clinical implementation. A disadvantage is that KIM delivers additional imaging dose to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗