Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV CAPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Office of Legacy Management Decision Tree for Solar Photovoltaic Projects - 13317

To support consideration of renewable energy power development as a land reuse option, the DOE Office of Legacy Management (LM) and the National Renewable Energy Laboratory (NREL) established a partnership to conduct an assessment of wind and solar renewable energy resources on LM lands. From a solar capacity perspective, the larger sites in the western United States present opportunities for constructing solar photovoltaic (PV) projects. A detailed analysis and preliminary plan was developed for three large sites in New Mexico, assessing the costs, the conceptual layout of a PV system, and the electric utility interconnection process. As a result of the study, a 1,214-hectare (3,000-acre) site near Grants, New Mexico, was chosen for further study. The state incentives, utility connection process, and transmission line capacity were key factors in assessing the feasibility of the project. LM's Durango, Colorado, Disposal Site was also chosen for consideration because the uranium mill tailings disposal cell is on a hillside facing south, transmission lines cross the property, and the community was very supportive of the project. LM worked with the regulators to demonstrate that the disposal cell's long-term performance would not be impacted by the installation of a PV solar system. A number of LM-unique issues were resolved in making the site available for a private party to lease a portion of the site for a solar PV project. A lease was awarded in September 2012. Using a solar decision tree that was developed and launched by the EPA and NREL, LM has modified and expanded the decision tree structure to address the unique aspects and challenges faced by LM on its multiple sites. The LM solar decision tree covers factors such as land ownership, usable acreage, financial viability of the project, stakeholder involvement, and transmission line capacity. As additional sites are transferred to LM in the future, the decision tree will assist in determining whether a solar PV project is feasible on the new sites. (authors)

14 SOLAR ENERGY↗

Impact of Dynamic Storage Capacity Valuation in Capacity Expansion Models

This presentation summarizes the motivation and results from the corresponding International Energy Workshop (IEW) conference paper CP-6A20-71462. Both the slide deck and paper discuss the impact of dynamic storage capacity valuation in capacity expansion models (CEMs), which are tools commonly used by power system planners, policymakers, and other stakeholders to inform decisions regarding the buildout of the electric grid. The objective of this analysis is to demonstrate the impact with a CEM of moving from a static storage capacity value (CV) to a curve-fitted approximation that captures the interactions between storage duration, PV penetrations, and storage penetration. We fit and then use those curves to calculate the battery storage CV as a function of the storage duration, storage penetration, and PV penetration. We use the Regional Energy Deployment System (ReEDS) model developed at the National Renewable Energy Laboratory (NREL) to show the impact of this improved storage capacity valuation on deployment. We also provide a curve fit equation for use by other modeling teams. This exogenous, but dynamic, approach is meant to be a first step in improving the representation of storage in CEMs.

14 SOLAR ENERGY↗

Impact of Dynamic Storage Capacity Valuation in Capacity Expansion Models: Preprint

This paper looks at the impact of dynamic storage capacity valuation in capacity expansion models (CEMs), which are tools commonly used by power system planners, policymakers, and other stakeholders to inform decisions regarding the buildout of the electric grid. The objective of this analysis is to demonstrate the impact with a CEM of moving from a static storage capacity value (CV) to a curve-fitted approximation that captures the interactions between storage duration, PV penetrations, and storage penetration. We fit and then use those curves to calculate the battery storage CV as a function of the storage duration, storage penetration, and PV penetration. We use the Regional Energy Deployment System (ReEDS) model developed at the National Renewable Energy Laboratory (NREL) to show the impact of this improved storage capacity valuation on deployment. We also provide a curve fit equation for use by other modeling teams. This exogenous, but dynamic, approach is meant to be a first step in improving the representation of storage in CEMs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

Cost Benefit Analysis of Solar PV for the City of Oldsmar, FL

The City of Oldsmar is in the early stages of exploring renewable energy opportunities as a part of their initiative to reduce energy costs, improve backup power capacity, and begin the transition to more sustainable operations. The city is particularly interested in deploying a floating or ground-mounted solar PV system at its wastewater treatment plant. Currently, there are no solar PV installations in Oldsmar and there has been hesitancy to implement such a project due to the possible capital costs and limited technical capacity. Despite this the initiative has gained internal buy-in among staff working for the city. To assist with gaining more buy-in and making future decisions the city sought technical assistance (TA) from the Energy to Communities (E2C) Expert Match Program. Through the Expert Match Program, the city received TA provided by the Pacific Northwest National Lab (PNNL) to evaluate the cost effectiveness of several solar options. This report details the analysis and results of the work performed for TA.

14 SOLAR ENERGY↗

Managing Solar Photovoltaic Integration in the Western United States Appendix: Reference and High Solar Photovoltaic Scenarios for Three Regions [Slides]

This slide deck is an appendix to a paper series that examines potential challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations. The series uses the western U.S. power system for these investigations because it is a region the authors and their colleagues have already extensively studied. We are therefore well-suited to analyze even higher PV penetrations and then examine the results in multiple models to determine whether our current approaches are missing key details that only emerge at higher PV penetrations. This deck details the systems underlying those analyses and how they were modeled using the Resource Planning Model (RPM), a capacity expansion modeling tool. We examine both Western Interconnection-wide and regional results for three regions in the Western U.S. with significantly different existing power systems and connections to neighboring regions; this provides a more balanced picture as to how power systems with high PV penetration might emerge in different contexts and what the resulting grid challenges, if any, might be.

14 SOLAR ENERGY↗

Hosting Capacity Analysis for Developers

NREL's dynamic hosting capacity analysis can help you better understand the thresholds at which new distributed photovoltaic (DPV) systems will trigger upgrades to the electrical distribution system. This fact sheet is for PV developers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Future-proofing photovoltaics module reliability through a unifying predictive modeling framework

Solar energy, especially photovoltaics (PV), plays a significant role in the global energy transition required for decarbonization. Technological advancements in increasing efficiencies coupled with cost reductions through economies of scale made PV a cost-competitive energy source set to exceed the milestone of 1 TW globally deployed capacity in 2022. However, ongoing downward price pressure coupled with increasing service life expectations creates tremendous challenges for reliability engineers in ensuring the safe and reliable operation of PV modules and systems over the anticipated service life. Today's reliability research efforts aim for module lifetimes of up to 50 years. Still, our current tools fall short in accurately assessing degradation mechanisms and failure modes over such extended periods. We argue that the well-established PV reliability learning cycle needs to be accelerated to keep up with the rapid technological advancements and high expectations that are put on PV and its role in the global energy transition. In this article, we explore the evolution of the PV reliability learning cycle and highlight the significance that predictive modeling capabilities will have on future PV module reliability. We propose creating a unifying modeling framework - which once established will enable the holistic assessment of PV module reliability, accelerate the PV reliability learning cycle, and bring us closer to quantitative service life predictions of PV modules.

14 SOLAR ENERGY↗

Installed Cost Benchmarks and Deployment Barriers for Residential Solar Photovoltaics with Energy Storage: Q1 2016

In this report, we fill a gap in the existing knowledge about PV-plus-storage system costs and value by providing detailed component- and system-level installed cost benchmarks for residential systems. We also examine other barriers to increased deployment of PV-plus-storage systems in the residential sector. The results are meant to help technology manufacturers, installers, and other stakeholders identify cost-reduction opportunities and inform decision makers about regulatory, policy, and market characteristics that impede solar plus storage deployment. In addition, our periodic cost benchmarks will document progress in cost reductions over time. To analyze costs for PV-plus-storage systems deployed in the first quarter of 2016, we adapt the National Renewable Energy Laboratory's component- and system-level cost-modeling methods for standalone PV. In general, we attempt to model best-in-class installation techniques and business operations from an installed-cost perspective. In addition to our original analysis, model development, and review of published literature, we derive inputs for our model and validate our draft results via interviews with industry and subject-matter experts. One challenge to analyzing the costs of PV-plus-storage systems is choosing an appropriate cost metric. Unlike standalone PV, energy storage lacks universally accepted cost metrics, such as dollars per watt of installed capacity and lifetime levelized cost of energy. We explain the difficulty of arriving at a standard approach for reporting storage costs and then provide the rationale for using the total installed costs of a standard PV-plus-storage system as our primary metric, rather than using a system-size-normalized metric.

14 SOLAR ENERGY↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗

Empirically Derived Strength of Residential Roof Structures for Solar Installations

Engineering certification for the installation of solar photovoltaic (PV) modules on wood roofs is often denied because existing wood roofs do not meet structural design codes. This work is intended to show that many roofs are actually sufficiently strong given the conservatism in codes, documented allowable strengths, roof structure system effects, and beam composite action produced by joist-sheathing interaction. This report provides results from a testing program to provide actual load carrying capacity of residential rooftops. The results reveal that the actual load carrying capacity of structural members and systems tested are significantly stronger than allowable loads provided by the International Residential Code (IRC 2009) and the national structural code found in Minimum Design Loads for Buildings and Other Structures (ASCE 7-10). Engineering analysis of residential rooftops typically ignores the system affects and beam composite action in determining rooftop stresses given a potential PV installation. This extreme conservatism combined with conservatism in codes and published allowable stress values for roof building materials (NDS 2012) lead to the perception that well built homes may not have adequate load bearing capacity to enable a rooftop PV installation. However, based on the test results presented in this report of residential rooftop structural systems, the actual load bearing capacity is several times higher than published values (NDS 2012).

Dwyer, Stephen F.↗

Photovoltaic system costs using local labor and materials in developing countries

The use of photovoltaic (PV) technology in countries that do not presently have high technology industrial capacity was investigated. The relative cost of integrating indigenous labor (and manufacturing where available) into the balance of the system industry of seven countries (Egypt, Haiti, the Ivory Coast, Kenya, Mexico, Nepal, and the Phillipines) was determined. The results were then generalized to other countries, at most levels of development. The results of the study imply several conclusions: (1) the cost of installing and maintaining comparable photovoltaic systems in developing countries is less than in the United States; (2) skills and some materials are available in the seven subject countries that may be applied to constructing and maintaining PV systems; (3) there is an interest in foreign countries in photovoltaics; and (4) conversations with foreign nationals suggest that photovoltaics must be introduced in foreign markets as an appropriate technology with high technology components rather than as a high technology system.

Jacobson, E.↗

Using RPS Policies to Grow the Solar Market in the United States

The market for photovoltaics in the United States remains small relative to the nation's solar resource potential. Nonetheless, annual grid-connected PV installations have grown from just 4 MW in 2000 to over 100 MW in 2006, fast enough to the catch the attention of the global solar industry. The state of California deserves much of the credit for this growth. The State's historical rebate programs resulted in roughly 75% of the nation's grid-connected PV additions from 2000 through 2006 being located in California, and the $3 billion California Solar Initiative will ensure that the State remains a mainstay of the US solar industry for years to come. But California is not the only market for solar in the US; other states have recently developed policies that may rival those of the western state in terms of future growth potential. In particular, 25 states, as well as Washington, D.C., have established renewables portfolio standards (RPS), sometimes called quota systems in Europe, requiring electricity suppliers in those states to source a minimum portion of their need from renewable electricity. (Because a national RPS is not yet in place, my focus here is on state policies). Under many of these state policies, solar is not expected to fare particularly well: PV installations simply cannot compete on cost or scale with large wind plants in the US, at least not yet. In response, an expanding list of states have established solar or distributed generation (DG) set-asides within their RPS policies, effectively requiring that some fraction of RPS-driven supply derive from solar energy. The popularity of set-asides for solar and/or DG has increased dramatically in recent years. Already, 11 states and D.C. have developed such RPS set-asides. These include states with outstanding solar resources, such as Nevada, Arizona, Colorado, and New Mexico, as well as areas where the solar resource is less robust, including North Carolina, Maryland, Pennsylvania, New Jersey, New York, New Hampshire, Delaware, and DC. Among those states with set-asides, two are restricted to PV applications, nine also allow solar-thermal electric to qualify, three allow solar heating and/or cooling to qualify, and three have broader renewable DG set-asides. The policies also differ in their targets and timeframes, whether projects must be located in-state, the application of cost caps, and the degree of oversight on how suppliers contract with solar projects. Only three of these states have more than two years of experience with solar or DG set-asides so far: Arizona, Nevada, and New Jersey. And yet, despite the embryonic stage of these policies, they have already begun to have a significant impact on the grid-connected PV market. From 2000-2006, 16% (or 48 MW) of grid-connected PV installations in the US occurred in states with such set-asides, a percentage that increases to 67% if one only considers PV additions outside of California. The importance of these programs is growing and will continue to expand. In fact, if one assumes (admittedly somewhat optimistically) that these policies will be fully achieved, then existing state solar or DG set-asides could result in 400 MW of solar capacity by 2010, 2,000 MW by 2015, and 6,500 MW by 2025. This equates to annual additions of roughly 100 MW through 2010, increasing to over 500 MW per year by 2015 and 700 MW per year by 2020. PV is not assured of all of this capacity, and will receive strong competition from solar-thermal electric facilities in the desert southwest. Nonetheless, set-asides in those states outside of the southwest will favor PV, and even some of the southwestern states have designed their RPS programs to ensure that PV fares well, relative to other forms of solar energy. Since 2000, Arizona and, more recently, New Jersey have represented the largest solar set-aside-driven PV markets. Even more-recent additions are coming from Colorado, Nevada, New York, and Pennsylvania. In the long-term, the largest markets for solar electricity are predicted to include New Jersey, Maryland, Arizona, and Pennsylvania. How do these states stack up against California, with a goal of 3,000 MW of new solar capacity by 2016? Though none of the states with solar set-asides are predicted to reach 3,000 MW of solar from their RPS policies alone, three are expected to exceed 1,000 MW (New Jersey, Maryland, and Arizona). And, if stated on a percentage-of-load basis, then the solar targets in New Mexico, Arizona, New Jersey, and Maryland all exceed California's goal. Of course, achieving these targets is not assured. States with solar set-asides have developed various types of cost caps, many of which may ultimately become binding, thereby limiting future solar growth. Penalties for lack of compliance may be insufficient. Finally, some states continue to struggle with how to encourage long-term contracting for solar generation, and to ensure continued rebate programs for smaller PV installations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗