Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV MODULES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Photovoltaic Module Reliability Workshop 2012: February 28 - March 1, 2012 [Slides]

NREL's Photovoltaic (PV) Module Reliability Workshop (PVMRW) brings together PV reliability experts to share information, leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology--both critical goals for moving PV technologies deeper into the electricity marketplace.

14 SOLAR ENERGY↗

Degradation mechanisms and partial shading of glass-backsheet and double-glass photovoltaic modules in three climate zones determined by remote monitoring of time-series current–voltage and power datastreams

Degradation and partial shading impact the long-term reliability and power production of photovoltaic (PV) modules and power plants. Time-series power (P mp ) and current–voltage (I-V) curve datastreams from PV modules enable a remote diagnostic approach to quantify active degradation mechanisms and identify partial shading. We study three to nine years of these datastreams, including 3.6 million P mp I-V curves and 36 million values, from eight PV modules, four each of double-glass and glass-backsheet module architectures, located in three distinctly different Köppen-Geiger climate zones, to determine the module’s performance loss rates (PLR), identify active degradation mechanisms and power loss modes, along with partial shading by local objects. Considering both module architectures, PLR results indicate that the BSh climate zone is the most aggressive for module degradation, while the Alpine ET zone is the mildest climate. PLR of double-glass modules located in BWh and BSh climate zones are different due to the significantly greater uniform current loss (ΔP Isc ) for double-glass modules in BSh, at a 5% significance level. Power loss for four out of five modules located in the BWh and BSh climates are dominated by uniform current degradation. Statistical analysis of multistep I-V curves detects partial shading experienced by three studied modules with details of the shading profile, the shading Poynting vector diagram for the obstacle’s relative position, shading scenarios, and duration. Lastly, this work demonstrates how remote monitoring and diagnosis of P mp & I-V time-series of modules can provide quantitative operations and maintenance insights into system performance, degradation mechanisms, and shading.

14 SOLAR ENERGY↗

Experimental natural convection on vertical surfaces for building integrated photovoltaic (BIPV) applications

An experimental study on natural convection in an open channel is carried out in order to investigate the effect of the geometrical configuration of heat sources on the heat transfer behaviour. To this aim, a series of vertical heaters are cooled by natural convection of air flowing between two parallel walls. The objective of the work is to investigate the physical mechanisms which influence the thermal behaviour of a double-skin photovoltaic (PV) facade. This results in a better understanding of the related phenomena and infers useful engineering information for controlling the energy transfers from the environment to the PV surfaces and from the PV surfaces to the building. Furthermore increasing the heat transfer rate from the PV surfaces increases the conversion efficiency of the PV modules since they operate better as their temperature is lower. The test section consists in a double vertical wall, 2 m high, and each wall is constituted by 10 different heating modules 0.2 m high. The heater arrangement simulates, at a reduced scale, the presence of a series of vertical PV modules. The heat flux at the wall ranges from 75 to 200 W/m{sup 2}. In this study, the heated section is 1.6 m in height, preceded by an adiabatic of 0.4 m in height. Different heating configurations are analyzed, including the uniform heating mode and two different configurations of non uniform, alternate heating. The experimental procedure allows the wall surface temperature, local heat transfer coefficient and local and average Nusselt numbers to be inferred. The experimental evidences show that the proper selection of the separating distance and heating configuration can noticeably decrease the surface temperatures and hence enhance the conversion efficiency of PV modules. (author)

14 SOLAR ENERGY↗

Partial Shade Stress Test for Thin-Film Photovoltaic Modules: Preprint

Partial shade of monolithic thin-film PV modules can cause reverse-bias conditions leading to permanent damage. In this work, we propose a partial shade stress test for thin-film PV modules that quantifies permanent performance loss. We designed the test with the aid of a computer model that predicts the local voltage, current and temperature stress that result from partial shade. The model predicts the module-scale interactions among the illumination pattern, the electrical properties of the photovoltaic material and the thermal properties of the module package. The test reproduces shading and loading conditions that may occur in the field. It accounts for reversible light-induced performance changes and for additional stress that may be introduced by light-enhanced reverse breakdown. We present simulated and experimental results from the application of the proposed test.

14 SOLAR ENERGY↗

From cells to laminate: probing and modeling residual stress evolution in thin silicon photovoltaic modules using synchrotron X-ray micro-diffraction experiments and finite element simulations

Fracture of silicon crystalline solar cells has recently been observed in increasing percentages especially in solar photovoltaic (PV) modules involving thinner silicon solar cells (<200 μm). Many failures due to fracture have been reported from the field because of environmental loading (snow, wind, etc.) as well as mishandling of the solar PV modules (during installation, maintenance, etc.). However, a significantly higher number of failures have also been reported during module encapsulation (lamination) indicating high residual stress in the modules and thus more prone to cell cracking. Here in this paper we report through the use of synchrotron X-ray submicron diffraction coupled with physics-based finite element modeling, the complete residual stress evolution in mono-crystalline silicon solar cells during PV module integration process. For the first time, we unravel the reason for the high stress and cracking of silicon cells near soldered inter-connects. Our experiments revealed a significant increase of residual stress in the silicon cell near the solder joint after lamination. Moreover, our finite element simulations show that this increase of stress during lamination is a result of highly localized bending of the cell near the soldered inter-connects. Further, the synchrotron X-ray submicron diffraction has proven to be a very effective way to quantitatively probe mechanical stress in encapsulated silicon solar cells. Thus, this technique has ultimately enabled these findings leading to the enlightening of the role of soldering and encapsulation processes on the cell residual stress. This model can be further used to suggest methodologies that could lead to lower stress in encapsulated silicon solar cells, which are the subjects of our continued investigations.

14 SOLAR ENERGY↗

PV array simulator development and validation.

The ability to harvest all available energy from a photovoltaic (PV) array is essential if new system developments are to meet levelized cost of energy targets and achieve grid parity with conventional centralized utility power. Therefore, exercising maximum power point tracking (MPPT) algorithms, dynamic irradiance condition operation and startup and shutdown routines and evaluating inverter performance with various PV module fill-factor characteristics must be performed with a repeatable, reliable PV source. Sandia National Laboratories is collaborating with Ametek Programmable Power to develop and demonstrate a multi-port TerraSAS PV array simulator. The simulator will replicate challenging PV module profiles, enabling the evaluation of inverter performance through analyses of the parameters listed above. Energy harvest algorithms have traditionally implemented methods that successfully utilize available energy. However, the quantification of energy capture has always been difficult to conduct, specifically when characterizing the inverter performance under non-reproducible dynamic irradiance conditions. Theoretical models of the MPPT algorithms can simulate capture effectiveness, but full validation requires a DC source with representative field effects. The DC source being developed by Ametek and validated by Sandia is a fully integrated system that can simulate an IV curve from the Solar Advisor Model (SAM) module data base. The PV simulator allows the user to change the fill factor by programming the maximum power point voltage and current parameters and the open circuit voltage and short circuit current. The integrated PV simulator can incorporate captured irradiance and module temperature data files for playback, and scripted profiles can be generated to validate new emerging hardware embedded with existing and evolving MPPT algorithms. Since the simulator has multiple independent outputs, it also has the flexibility to evaluate an inverter with multiple MPPT DC inputs. The flexibility of the PV simulator enables the validation of the inverter's capability to handle vastly different array configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Economically Sustainable Scaling of Photovoltaics to Meet Climate Targets

To meet climate goals, photovoltaics (PV) deployment will have to grow rapidly over the next fifteen years. We identify two barriers to this growth: scale-up of manufacturing capacity and the cost of PV module production. We explore several technoeconomic approaches to overcoming these barriers and identify deep reductions in the capital intensity (capex) of PV module manufacturing and large increases in module efficiency as the most promising routes to rapid deployment. Given the lag inherent in rolling out new technology, we explore an approach where growth is fueled by debt or subsidies in the short-term and technological advances in the medium term. Finally, we analyze the current capex structure of crystalline silicon PV module manufacturing to identify potential savings.

14 SOLAR ENERGY↗

Finite Element Simulation of Mixed-Mode PV Encapsulant Delamination Based on Cohesive Zone Model: Preprint

A finite element model (FEM) was developed to simulate the mixed-mode delamination failure at the encapsulant interface within PV modules under mixed-mode loading condi- tions. Parameters to characterize the bilinear traction-separation constitutive behavior of cohesive elements were determined by testing the pure mode I critical fracture energy of the photovotaic(PV) cell interface using the width-tapered beam and fitting the simulated load-displacement curve with the tested curve. This developed FEM can be used to predict the critical temperature changes, at which delamination would initiate, of PV modules with different sizes and provide guidance for the design of PV module with better reliability.

97 MATHEMATICS AND COMPUTING↗

On Residual Stresses and Reference Temperatures in Thermomechanical Simulations of Photovoltaic Modules Using the Finite Element Method

Thermomechanical simulation of photovoltaic (PV) modules using the finite element method (FEM) is a useful tool to evaluate module design features in terms of structural integrity, reliability, and durability. One of the main challenges in the numerical modeling of a PV module is the incorporation of residual stresses induced by the manufacturing process. Modeling assumptions and abstractions are necessary to limit the model complexity and reduce the computational time. However, oversimplifications and incorrect assumptions can lead to erroneous numerical results. Unfortunately, much simulation work still neglects process-induced stresses. This can lead to incorrect predictions of the stress-strain history and erroneous conclusions during the design process. In this work, we review current modeling practices for incorporating process-induced stresses, and contrast numerical models that consider residual stresses with those that neglect them. We find that the simulation objective and available material properties dictate which process steps need to be modeled, and explore in depth the modeling of residual stresses induced by the lamination process. We demonstrate that a simplified cooldown procedure at the beginning of the simulation can increase the model accuracy and discuss appropriate choices for starting and reference temperatures in the finite element model.

14 SOLAR ENERGY↗

Comparison of Predictive Models for Photovoltaic Module Performance: Preprint

This paper examines three models used to estimate the performance of photovoltaic (PV) modules when the irradiances and PV cell temperatures are known. The results presented here were obtained by comparing modeled and measured maximum power (Pm) for PV modules that rely on different technologies.

14 SOLAR ENERGY↗

A high efficiency photovoltaic module integrated converter with the asymmetrical half-bridge flyback converter

A module integrated converter (MIC) for a photovoltaic (PV) cell is important part of power conditioning system (PCS). It performs maximum power point tracking of a PV cell to generate the power as much as possible from solar energy. There are several methods for connection between the PV modules and the MICs. In order to avoid partial shading effects, converter-per-module approach was proposed. The MIC that performs maximum power point tracking (MPPT), if it is low efficiency, is no use. The MIC whose output is connected to the output of PV module was proposed for high efficiency. However, there are some problems. In this study, an asymmetrical half-bridge flyback converter is proposed instead of the original flyback converter with same method to solve the problems. The proposed MIC was built to verify the performance. The new topology using soft switching technique showed good performance for the efficiency. At the higher power, the efficiency of the proposed converter is higher than existing converter. (author)

14 SOLAR ENERGY↗

Relating Product Prices to Long‐Run Marginal Cost: Evidence from Solar Photovoltaic Modules

Abstract A basic tenet of microeconomics is that for a competitive industry in equilibrium the market price of a product will be equal to its marginal cost. This paper develops a model framework and a corresponding empirical inference procedure for estimating long‐run marginal cost in industries where production costs decline over time. In the context of the solar photovoltaic (PV) module industry, we rely primarily on firm‐level financial accounting data to estimate the long‐run marginal cost of PV modules for the years 2008–2013. During those years, the industry experienced both unprecedented price declines and significant expansions of manufacturing capacity. We compare the trajectory of average sales prices with the estimated long‐run marginal costs in order to quantify the extent to which actual price declines were attributable to reductions in production costs. The trajectory of estimated product costs is then extrapolated to forecast an equilibrium trend line for future PV module prices.

Reichelstein, Stefan↗

FTIR Investigation of EVA Chemical Bonding Environment and Its Impact on Debond Energy

The chemical makeup of ethylene vinyl acetate (EVA) interfaces in photovoltaic (PV) modules is probed via Fourier-transform infrared spectroscopy (FTIR) to determine the impact of the EVA formulation on the adhesion degradation. EVA samples laminated with glass particles are used to demonstrate the effect of damp heat exposure on the glass-EVA interface, showing that increasing silane content increases chemical stability. Delamination interfaces created in one cell modules demonstrate a high correlation between the siloxane bonding at the silicon cell-EVA interface and the debond energy. A significant decrease in debond energy after UV exposure is also shown to be due in part to decreasing siloxane bond density at the interface. However, FTIR results indicated contributions to the adhesion beyond the chemical interface, and a basic tensile test indicates increasing bulk mechanical properties with increasing silane. These results demonstrate the importance of the EVA formulation on its adhesion performance and long-term reliability. Furthermore, it is shown that FTIR is a capable technique for assessing and quantifying chemical mechanisms within PV modules. These results can then be used to more effectively model module lifetimes and to better design polymer systems for PV modules.

14 SOLAR ENERGY↗

Automatic Crack Segmentation and Feature Extraction in Electroluminescence Images of Solar Modules

The effect of cracks in solar cells on the long-term degradation of photovoltaic (PV) modules remains to be determined. To investigate this effect in future studies, it is necessary to quantitatively describe the crack features (e.g., length) and correlate them with module power loss. Electroluminescence (EL) imaging is a common technique for identifying cracks. However, it is currently challenging and time-consuming to identify cracks in a large number of EL images and quantify complex crack features by human inspection. This article introduces a fast semantic segmentation method (~0.18 s/cell) to automatically segment cracks from EL images and algorithms to extract crack features. Here we fine-tuned a UNet neural network model using pretrained VGG16 as the encoder and obtained an average F1 score of 0.875 and an intersection over union score of 0.782 on the testing set. With cracks and busbars segmented, we developed algorithms for extracting crack features, including the crack-isolated area, the brightness inside the isolated area, and the crack length. We also developed an automatic preprocessing tool for cropping individual cell images from EL images of PV modules (~0.72 s/module). Our codes are published as open-source an software, and our annotated dataset composed of various types of cells is published as a benchmark for crack segmentation in EL images.

14 SOLAR ENERGY↗

Performance Analysis of Photovoltaic Thermal System Using Silicone Oil Spectrum Filter

The paper reports use of silicone oil as spectrum filter and heat absorber for photovoltaic thermal systems. The terrestrial solar spectrum is in the wavelength range of 0.25 to 2.5 μm. The response range of C-Si solar cell is 0.75 to 1.125 μm. In the current study, the feasibility of Silicone oil (Transformer oil) as spectrum filter cum heat absorber for C-Si solar cell is investigated. The spectroscopic analysis of 1 cm thick Silicone oil sample with UV-VIS-NIR spectrophotometer is carried out. This analysis concludes that the Silicone oil is transparent to the response range of C-Si solar cell. Also, it shows a significant absorption for UV and IR part of the spectrum. A glass container with 1 cm thick Silicone oil layer is mounted on the C-Si PV module. The performance of the system is analyzed using solar simulator at irradiance of 1000 W/m{sup 2}, AM 1.5 G and in natural sunlight at Nagpur (21.10 N, 79.090 E). The experiments were performed for the entire year for time period of one hour in the noon. With Silicone oil spectrum filter, the average electrical efficiency of the PV module was found increase marginally. However, for 10 W module, 27 W average heat gain was recorded. In this study, the surface area of PV module (30 × 35 cm = 0.105 m{sup 2}) was very small. In actual practice, for large scale installations, significant heat gain is possible. The experimentation and significant outcomes are discussed in this article.

14 SOLAR ENERGY↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Feasibility of Passive MOSFET Paralleling for Photovoltaic Current-Voltage Curves

Current-voltage curves are an important method of characterizing Photovoltaic (PV) Modules. NREL has developed several low-cost MOSFET-based devices that can characterize PV cells and modules. The size of PV modules that can be measured is limited by the power limitations of a single MOSFET. By using multiple MOSFET devices, each can operate at a lower current, paralleled on resistance is also decreased allowing for higher power loads. Operating multiple devices in parallel can cause an imbalance in current, thus causing some devices to conduct more, pushing them into a thermal runaway condition. To investigate this, an active feedback circuit was tested with paralleled devices using a PV module load. The efficacy, limitations, and design considerations of using parallel MOSFET loads for PV characterization are explored. This work is not new, but the implementation of a paralleled architecture in a low cost characterization tool is novel.

14 SOLAR ENERGY↗

Impact of environmental variables on the degradation of photovoltaic components and perspectives for the reliability assessment methodology

Backsheet cracking has been a major issue observed in the field; however, standardized qualification tests, such as IEC61215, are inadequate to reliably identify such failures of PV modules due to the lack of the critical weathering factors applied sequentially or in combination, such as those found in the service environments. To address this problem, in this work we investigated the effects of various environmental variables on the degradation and failure behaviors of the polyamide-based backsheet in PV modules retrieved from five different locations, encompassing a variety of climates, including humid subtropical, hot-summer Mediterranean, tropical savanna climate and hot arid. The correlations between the degradation indicators and the weathering variables were further demonstrated by principle components analysis (PCA). We found strong relationships between: carbonyl formation and reflected solar radiation; hydroxyl formation and module temperature; yellowness and NO2 concentration, while no simple correlation could be found between a specific weathering factor and cracking. By introducing additional stress factors to the aged polyamide-based backsheet films with the novel 'fragmentation test', we successfully reproduced the field cracking behaviour. This study has demonstrated that different degradation modes of PV components respond differently to the environmental stresses encountered in service. Thereby, any accelerated laboratory test based on a single set condition or lacking key environmental variables would be inadequate to assess the long-term performance of PV modules and components. A new reliability-based methodology is proposed to quantitatively link laboratory testing with field results for the service life prediction of PV materials.

14 SOLAR ENERGY↗