Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Optimize Topology, Component Sizes, and Operating Strategy of Participant's Protype: Cooperative Research and Development Final Report

The purpose of the project was to complete testing of Shine Technologies LLC’s prototype power system called “Juicebox 3.0.” Testing of the prototype using NREL’s hardware-in-the-loop capabilities, including a DC power supply programmed to simulate PV module output and provide the JuiceBox 3.0 at the specified power level and with a load bank of sufficient capacity to mimic DC and AC loads connected to the outlets of the Juicebox 3.0. The unit is provided with SAE wire connectors. A photo of a JuiceBox 3.0 unit is shown in Figure 1 below.

14 SOLAR ENERGY↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY↗

Effects of Revegetation on Soil Physical and Chemical Properties in Solar Photovoltaic Infrastructure

Solar photovoltaic (PV) technology is being deployed at an unprecedented rate. However, utility-scale solar energy development is land intensive and its large-scale installation can have negative impacts on the environment. In particular, solar energy infrastructure can require extensive landscape modification that transforms soil ecological functions, thereby impacting hydrologic, vegetative, and carbon dynamics. However, reintroducing native vegetation to solar PV sites may be a means of restoring their soils. To this end, we investigated critical soil physical and chemical parameters at a revegetated photovoltaic array and an adjacent reference grassland in Colorado, United States. Seven years after revegetation, we found that carbon and nitrogen remained lower in the PV soil than in the reference soil and contained a greater fraction of coarse particles. We also found that the PV modules introduced heterogeneity in the soil moisture distribution, with precipitation accumulating along the lower edges of panels. The redistribution of soil moisture by panel arrays could potentially be used in concert with planting strategies to maximize plant growth or minimize soil erosion, and should be considered when evaluating the potential to co-locate vegetation with solar infrastructure.

14 SOLAR ENERGY↗

Cyberguardians Webinar

Robust solar industry growth is creating a shortage of U.S. workers who are knowledgeable in emerging Distributed Energy Resource (DER) technologies including networking, operational software, smart advanced inverters, smart advanced PV modules, and cybersecurity. Retraining military veterans and other qualified individuals to fill workforce gaps in those technologies is the project focus. The project leverages the experience and contributions of DER and cybersecurity experts, educational organizations offering accreditation, and groups serving our nation’s veterans to meet its goals. To bridge this workforce skills gap, the Cyberguardians and STEM Warriors project will establish a complete learning and career advancement system for veterans, transitioning military personnel and other qualified individuals into the DER workforce. The project will guide participants successfully through the process of program/vocation selection, curriculum enrollment, academic mentoring, degree or certificate attainment, job board enrollment, introduction to hiring managers at DER companies, and successful job acquisition. This webinar was used to promote the Cyberguardians program and to ensure ample news coverage to reach veterans, employers, and others that would benefit from this program.

14 SOLAR ENERGY↗

More Than Recycling: How Should We Define Circularity Goals for PV in a Global Energy Transition? Preprint

Energy transition to carbon-free electricity is a crucial pillar of the Circular Economy. Renewable energy reduces environmental impacts and decarbonizes the production of other goods. But, manufacturing renewable energy sources, such as photovoltaic (PV) modules, require energy inputs that are currently carbon intensive. So, how do we decarbonize and circularize these critical technologies to achieve a sustainable energy transition? This work proposes that effective capacity-the installed capacity accounting for degradation rates and failures-is a critical metric to evaluate renewable energy technologies on the path toward circular economy and energy transitions. Our analyses also emphasize the importance of examining a suite of metrics incorporating mass and energy flows to identify potential tradeoffs and inform design or lifecycle management decisions holistically.

bifacial↗

Evaluation of Surface Crack Formation in Photovoltaic Backsheets Using Fragmentation and Finite Element Simulations: Preprint

Backsheet cracking is among the most commonly observed degradation modes of photovoltaic (PV) modules in the field. Cracks can reduce the ability of backsheets to fulfil their functions, for example, protection of the modules from the environment or electrical insulation. This work presents an evaluation of the degradation and cracking propensity of two backsheets during accelerated IEC TS 62788-7-2 A3 (International Electrotechnical Commission) aging with the fragmentation test: a co-extruded polyamide backsheet (AAA), and a laminated multilayer backsheet with a polyethylene terephthalate core and outer layer and ethylene vinyl acetate inner layer (PPE). Results show the surface embrittlement of the AAA outer layer during exposure. A longer time of exposure causes cracks to form at lower strains during stretching and creates deeper cracks. Accordingly, Young's modulus of the outer layer increases, as measured by cross-sectional nanoindentation. PPE exhibits cracking after exposure as well. While no similar increase of modulus or crack depth can be observed, the outer layer of PPE exhibits more obvious signs of erosion during exposure, including progressive morphological changes and thickness losses. A finite element model to simulate surface crack formation is devised, based on initially zero-thickness decohesion elements. Decohesion criteria define a critical stress, at which these elements grow, and cracks can begin to form. These criteria are obtained via parameter optimization by comparison between simulation and experiment. The model is used to interpret crack formation in both backsheets.

backsheet↗

More Than Recycling: The Importance of Multiple Metrics for a Circular Economy for PV in the Energy Transition

Energy transition to carbon-free electricity is a crucial pillar of the Circular Economy. Renewable energy reduces environmental impacts and decarbonizes the production of other goods. But, manufacturing renewable energy sources, such as photovoltaic (PV) modules, require energy inputs that are currently carbon intensive. So, how do we decarbonize and circularize these critical technologies to achieve a sustainable energy transition? This work proposes that effective capacity-the installed capacity accounting for degradation rates and failures-is a critical metric to evaluate renewable energy technologies on the path toward circular economy and energy transitions. Our analyses also emphasize the importance of examining a suite of metrics incorporating mass and energy flows to identify potential tradeoffs and inform design or lifecycle management decisions holistically.

bifacial↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

Combined-Accelerated Stress Testing of Photovoltaic Materials

By applying multiple environmental stresses in fieldrepresentative combinations and sequences, combined-accelerated stress testing (CAST) identifies degradation modes and failure mechanisms of photovoltaic (PV) modules and components that are missed by single stress factor accelerated testing.

14 SOLAR ENERGY↗

Highly Reliable Multi-Port Smart Inverter Modules for PV-Based Energy Systems

Generally, large electrolytic capacitors (E-caps) are required to decouple the double-line frequency power fluctuation inherent in all single-phase dc-ac or ac-dc converters. These E-caps pose the weak link in the photovoltaic (PV) inverter because they have poor reliability as a result of short life expectancy and higher equivalent series resistance (ESR) which leads to lower system efficiency. In this paper, multiport smart dual-inverter modules are proposed for residential PV inverter systems with balanced outputs to eliminate the requirement of large decoupling capacitors, thus leading to more reliable and highly efficient inverter modules. The balanced dual outputs are controlled in phase quadrature such that the double frequency current is completely eliminated. One phase supports the standalone residential loads, and the other phase interfaces with the grid, which is synchronized to the utility grid. Also, the proposed modular configuration is scalable to accommodate higher power rating by stacking and paralleling multiple modules. Simulation results for the dual-inverter modules rated for 1 kW each are presented to validate the proposed concept. Experimental results from a controller hardware-in-the-loop (CHIL) platform also verify its feasibility.

14 SOLAR ENERGY↗

In-situ I-V measurement of a module in a PV array

In one respect, disclosed is an in-situ current-voltage (I-V) measurement device for photovoltaic modules in a photovoltaic array, comprising a variable load, wherein the variable load is configured to be connected in parallel with a module, wherein the module is connected in series with at least one other module in a string, such that the module supplies current simultaneously to the string and to the variable load, and wherein the variable load is controlled by a controller, and wherein the controller is configured to shift an I-V operating point of the module, based at least upon varying the variable load.

Gostein, Michael↗

Industry Facing PV Degradation Prediction Tool and Database to Enable a 50-Year Life Module

The Photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 years. Furthermore, research efforts aim for up to 50 years of service life while keeping performance degradation at a minimum for decades of outdoor weathering - putting additional pressure on improving the accuracy of long-term durability and reliability assessments. Here there is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. A graphical user interface will aid in the understanding of the results. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. We use an integration pipeline approach that allows us to leverage weather data from the National Solar Radiation Database to perform geospatial degradation analysis in the US and worldwide. Our repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors. We hope to become a repository that can be used for weathering and degradation analysis for various applications beyond the PV industry.

degradation↗

Decay of Electrostatic Force of Dust Particles on Photovoltaic Modules

Photovoltaic (PV) energy yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. We have reported on direct measurements-using atomic force microscopy (AFM)-of strong electric-field-induced attraction and adhesion force (Fes) of dust particles onto solar panel that are 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, corroborated by observing the increase in system voltage-induced soiling rate. Here, we report another characteristic of Fes on soiling-long lasting or slow decay after turning off the high voltage applied to solar panels. The Fes decay time varies in a wide time range of 1 to 10 hours, depending on two factors: 1) either/both the cell or/and particle were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off-either connected through the power supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting Fes for hours can significantly affect the solar panel soiling after sunset, especially combined with water condensation.

14 SOLAR ENERGY↗

Long-lasting strong electrostatic attraction and adhesion forces of dust particles on photovoltaic modules

Photovoltaic (PV) energy-yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. The electrostatic attraction and adhesion force (F es ) of dust particles by the high voltages from solar panels have been reported to be 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, which has been corroborated by observing the increase in system voltage-induced soiling rate by setting up an outdoor test. Here, we report another characteristic of F es on soiling - long-lasting or slow decay after turning off the high voltage applied to solar panels. The F es decay time varies across a wide time range of 1 to 10 h, depending on two factors: 1) whether the cell, the particle, or both were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off - either connected through the power-supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting F es for hours can affect the solar panel soiling after sunset, and it can have an even greater effect when combined with water condensation at night.

14 SOLAR ENERGY↗

Q1-2025 Solar Photovoltaic System Cost Benchmarks

The U.S. Department of Energy’s solar office and its national laboratory partners analyze cost data for U.S. solar photovoltaic systems to develop cost benchmarks to measure progress toward goals and guide research and development programs. The cost data is available in an Excel spreadsheet model that can be downloaded here.

14 SOLAR ENERGY↗