Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Importance of filter’s microstructure in dynamic filtration modeling of gasoline particulate filters (GPFs): Inhomogeneous porosity and pore size distribution

The state-of-the-art multiscale modeling of GPFs including channel scale, wall scale, and pore scale is described. The microstructures of two GPFs were experimentally characterized. The pore size distributions of the GPFs were determined by mercury porosimetry. The porosity was measured by X-ray computed tomography (CT) and found to be inhomogeneous across the substrate wall. The significance of pore size distribution with respect to filtration performance was analyzed. The predictions of filtration efficiency were improved by including the pore size distribution in the filtration model. A dynamic heterogeneous multiscale filtration (HMF) model was utilized to simulate particulate filtration on a single channel particulate filter with realistic particulate emissions from a spark-ignition direct-injection (SIDI) gasoline engine. The dynamic evolution of filter’s microstructure and macroscopic filtration characteristics including mass- and number-based filtration efficiencies and pressure drop were predicted and discussed. The microstructure of the GPF substrate including inhomogeneous porosity and pore size distribution is found to significantly influence local particulate deposition inside the substrate and macroscopic filtration performance and is recommended to be resolved in the filtration model to simulate and evaluate the filtration performance of GPFs.

Environmental Molecular Sciences Laboratory↗

Agricultural Ice Nuclei at Southern Great Plains Supplemental Sampling (AGINSGP-SUPP) Field Campaign Report

The Agricultural Ice Nuclei at Southern Great Plains Supplemental Sampling (AGINSGP-SUPP) field campaign took place from April 8 to April 28, 2022. It included sample collection and analysis of filter samples for ice-nucleating particle (INP) concentrations. By enabling quantification of INPs at warmer temperatures (i.e., T > 258 K), these samples complemented the real-time observations of INPs that were performed as part of the AGINSGP campaign during the same period. In addition to collecting ground-based samples, the campaign collected vertical samples of INPs aboard the Atmospheric Radiation Measurement (ARM) tethered balloon system (TBS) as shown in Figure 1. These vertical samples complemented the vertical profiling of aerosol properties that was supported under a related Facilities Integrating Collaborations for User Science (FICUS) proposal. The overall aim of these three campaigns was to improve understanding of the sources and variability in observed INP concentrations at ARM’s SGP observatory. For example, warm-temperature INPs in this agricultural region are thought to originate in part from regional emissions of fertile, agricultural soils containing high organic content. Laboratory experiments have shown that soil particles with high organic content are more efficient INPs than inorganic soils (e.g., Tobo et al. 2014). Quantification of warm-temperature INPs under ambient conditions currently can only be achieved via offline methods such as the ARM ice-nucleation spectrometer (INS). Therefore, offline sampling for the INS was required to complement the real-time INP measurements conducted during the AGINSGP campaign.

, tethered balloon system↗

Microstructure of Neutron-Irradiated Al 3 Hf-Al Thermal Neutron Absorber Materials

A thermal neutron-absorbing metal matrix composite (MMC) comprised of Al 3 Hf particles in an aluminum matrix was developed to filter out thermal neutrons and create a fast flux environment for material testing in a mixed-spectrum nuclear reactor. Intermetallic Al 3 Hf particles capture thermal neutrons and are embedded in a highly conductive aluminum matrix that provides conductive cooling of the heat generated due to thermal neutron capture by the hafnium. These Al 3 Hf-Al MMCs were fabricated using powder metallurgy via hot pressing. The specimens were neutron-irradiated to between 1.12 and 5.38 dpa and temperatures ranging from 286 °C to 400 °C. The post-irradiation examination included microstructure characterization using transmission electron microscopy (TEM) and energy-dispersive X-ray spectroscopy. This study reports the microstructural observations of four irradiated samples and one unirradiated control sample. All the samples showed the presence of oxide at the particle–matrix interface. The irradiated specimens revealed needle-like structures that extended from the surface of the Al 3 Hf particles into the Al matrix. An automated segmentation tool was implemented based on a YOLO11 computer vision-based approach to identify dislocation lines and loops in TEM images of the irradiated Al-Al 3 Hf MMCs. This work provides insight into the microstructural stability of Al 3 Hf-Al MMCs under irradiation, supporting their consideration as a novel neutron absorber that enables advanced spectral tailoring.

36 MATERIALS SCIENCE↗

A method for extracting calibrated volatility information from the FIGAERO-HR-ToF-CIMS and its experimental application

The Filter Inlet for Gases and AEROsols (FIGAERO) is an inlet specificallydesigned to be coupled with the Aerodyne High-Resolution Time-of-FlightChemical Ionization Mass Spectrometer (HR-ToF-CIMS). The FIGAERO-HR-ToF-CIMSprovides simultaneous molecular information relating to both the gas- andparticle-phase samples and has been used to extract vapour pressures (VPs) ofthe compounds desorbing from the filter whilst giving quantitativeconcentrations in the particle phase. However, such extraction of vapourpressures of the measured particle-phase components requires use ofappropriate, well-defined, reference compounds. Vapour pressures for thehomologous series of polyethylene glycols (PEG)((H-(O-CH 2 -CH 2 )n-OH) for n=3 to n=8), covering a rangeof vapour pressures (VP) (10 -1 to 10 -7 Pa) that areatmospherically relevant, have been shown to be reproduced well by a range ofdifferent techniques, including Knudsen Effusion Mass Spectrometry (KEMS).This is the first homologous series of compounds for which a number of vapourpressure measurement techniques have been found to be in agreement,indicating the utility as a calibration standard, providing an ideal set ofbenchmark compounds for accurate characterization of the FIGAERO forextracting vapour pressure of measured compounds in chambers and the realatmosphere. To demonstrate this, single-component and mixture vapour pressuremeasurements are made using two FIGAERO-HR-ToF-CIMS instruments based on anew calibration determined from the PEG series. VP values extracted from bothinstruments agree well with those measured by KEMS and reported values fromliterature, validating this approach for extracting VP data from the FIGAERO.This method is then applied to chamber measurements, and the vapour pressuresof known products are estimated.

47 OTHER INSTRUMENTATION↗

Application of Ion Mobility Spectrometry (IMS) in forensic chemistry and toxicology with focus on biological matrices

The IMS (Ion Mobility Spectroscopy) instrument 'Ionscan' takes advantage of the fact that trace quantities of illicit drugs are adsorbed on dust particles on clothes, in cars and on other items of evidence. The dust particles are collected on a membrane filter by a special attachment on a vacuum cleaner. The sample is then directly inserted into the spectrometer and can be analyzed immediately. We show casework applications of a forensic chemistry and toxicology laboratory. One new application of IMS in forensic chemistry is the detection of psilocybin in dried mushrooms without any further sample preparation.

Bernhard, Werner↗

Thermally Actuated Hydraulic Pumps

Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research vessels. Heretofore, electrically actuated hydraulic pumps have been used for this purpose. By eliminating the demand for electrical energy for pumping, the use of the thermally actuated hydraulic pumps could prolong the intervals between battery charges, thus making it possible to greatly increase the durations of undersea exploratory missions.

Jones, Jack↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Development of High Strength HEPA Filters for Use in Demanding Air and Gas Streams - 17644

High-efficiency particulate air (HEPA) filters are used in a wide variety of applications, including the removal of radioactive particulate from process off-gas streams and the venting of waste storage containers. Porvair Filtration Group, specializing in the design and manufacture of robust filters in numerous industries, has worked to develop HEPA filter designs for use in such high-demand nuclear process-gas and air streams. Using the requirements of section FK of the American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment (ASME AG-1) as a guide, Porvair Filtration Group has designed filters which can withstand upset conditions to include elevated temperatures, high relative humidity, high particle-loading, and an unconventionally high differential pressure across the filter media; while maintaining excellent removal efficiencies. The process by which Porvair Filtration Group has reached optimized designs was based upon an extended test and development program. Design, manufacture, and testing of flat sheet media samples, geometrically equivalent model filters, and full-scale prototypes was performed at several Porvair Filtration Group facilities located in the United States and the United Kingdom. The methods and results of this development program are outlined in the following paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fluorescence-based remote irradiation sensor in liquid-filled hollow-core photonic crystal fiber

We report an irradiation sensor based on a fluorescent “flying particle” that is optically trapped and propelled inside the core of a water-filled hollow-core photonic crystal fiber. When the moving particle passes through an irradiated region, its emitted fluorescence is captured by guided modes of the fiber core and so can be monitored using a filtered photodiode placed at the fiber end. The particle speed and position can be precisely monitored using in-fiber Doppler velocimetry, allowing the irradiation profile to be measured to a spatial resolution of ∼10 μm. The spectral response can be readily adjusted by appropriate choice of particle material. Using dye-doped polystyrene particles, we demonstrate detection of green (532 nm) and ultraviolet (340 nm) light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-Sensor Data Filtering using Neuromorphic Computing for High Energy Physics Experiments

This work describes the investigation of neuromorphic computing-based spiking neural network (SNN) models used to filter data from sensor electronics in high energy physics experiments conducted at the High Luminosity Large Hadron Collider. We present our approach for developing a compact neuromorphic model that filters out the sensor data based on the particle's transverse momentum with the goal of reducing the amount of data being sent to the downstream electronics. The incoming charge waveforms are converted to streams of binary-valued events, which are then processed by the SNN. We present our insights on the various system design choices - from data encoding to optimal hyperparameters of the training algorithm - for an accurate and compact SNN optimized for hardware deployment. Our results show that an SNN trained with an evolutionary algorithm and an optimized set of hyperparameters obtains a signal efficiency of about 91% with nearly half as many parameters as a deep neural network.

R. Kulkarni, Shruti↗

Vacuum probe surface sampler

A vacuum probe surface sampler is described for rapidly sampling relatively large surface areas which possess relatively light loading densities of micro-organism, drug particles or the like. A vacuum head with a hollow handle connected to a suitable vacuum source is frictionally attached to a cone assembly terminating in a flared tip adapted to be passed over the surface to be sampled. A fine mesh screen carried by the vacuum head provides support for a membrane filter which collects the microorganisms or other particles. The head assembly is easily removed from the cone assembly without contacting the cone assembly with human hands.

Zahlava, B. A.↗

Effects of Fuel Properties on Particle Number and Particle Mass Emissions from Lean and Stoichiometric Gasoline Direct Injection Engine Operation

Engine-out particle size distributions and soot mass emissions were measured from a gasoline direct injection (GDI) engine fueled by seven different gasoline formulations. Additionally, particle size distributions were simultaneously measured downstream of a catalyzed gasoline particulate filter (GPF) to determine the size resolved filtration efficiency. Stoichiometric, lean homogeneous, and lean stratified combustion modes were studied at four steady-state engine conditions. The particulate matter (PM) Index was calculated for each fuel as a function of the double bond equivalent and vapor pressure of the fuel components. There was generally poor correlation between particle number (PN)/PM mass emissions and the PM Index for steady state stoichiometric conditions with clean injectors, which emitted low particle concentrations. However, under high-load lean homogeneous conditions, there was good correlation between PN/PM mass emission and the PM Index, with the exception that the high ethanol content fuel produced significantly higher PM emissions than the other fuels. Under lean stratified conditions, most fuels produced similar particle size distributions and concentrations with the exception that the E50 fuel produced significantly lower concentrations than the other fuels. These results demonstrate the profound sensitivity of particle emissions from high ethanol content fuel to engine operating conditions. Additionally, these results show the predominant factor influencing particle formation is charge mixture formation, which fuel properties influence, but not as significantly as engine conditions. Here, the GPF reduced the tailpipe particle number concentrations by 60 - 95% and showed evidence of passive regeneration under higher load lean engine conditions (Temp>400°C, Lambda>1.3). Total PN filtration efficiencies ranged from ~60 % with a clean filter to greater than 95% with as little as 25 mg/L of soot loaded on the filter with a most penetrating particle size (MPPS) between 100 and 150 nm. The GPF results show that GPF regeneration can be achieved with the added fuel efficiency benefit of lean operation.

33 ADVANCED PROPULSION SYSTEMS↗

Charged particle tracking in real-time using a full-mesh data delivery architecture and associative memory techniques

We present a flexible and scalable approach to address the challenges of charged particle track reconstruction in real-time event filters (Level-1 triggers) in collider physics experiments. The method described here is based on a full-mesh architecture for data distribution and relies on the Associative Memory approach to implement a pattern recognition algorithm that quickly identifies and organizes hits associated to trajectories of particles originating from particle collisions. We describe a successful implementation of a demonstration system composed of several innovative hardware and algorithmic elements. The implementation of a full-size system relies on the assumption that an Associative Memory device with the sufficient pattern density becomes available in the future, either through a dedicated ASIC or a modern FPGA. We demonstrate excellent performance in terms of track reconstruction efficiency, purity, momentum resolution, and processing time measured with data from a simulated LHC-like tracking detector.

47 OTHER INSTRUMENTATION↗

Kinetics, Products, and Brown Carbon Formation by Aqueous-Phase Reactions of Glycolaldehyde with Atmospheric Amines and Ammonium Sulfate

Glycolaldehyde (GAld) is a C 2 water-soluble aldehyde produced during the atmospheric oxidation of isoprene and many other species and is commonly found in cloudwater. Previous work has established that glycolaldehyde evaporates more readily from drying aerosol droplets containing ammonium sulfate (AS) than does glyoxal, methylglyoxal, or hydroxyacetone, which implies that it does not oligomerize as quickly as these other species. Here, we report NMR measurements of glycolaldehyde’s aqueous-phase reactions with AS, methylamine, and glycine. Reaction rate constants are smaller than those of respective glyoxal and methylglyoxal reactions in the pH range of 3–6. In follow-up cloud chamber experiments, deliquesced glycine and AS seed particles were found to take up glycolaldehyde and methylamine and form brown carbon. At very high relative humidity, these changes were more than 2 orders of magnitude faster than predicted by our bulk liquid NMR kinetics measurements, suggesting that reactions involving surface-active species at crowded air–water interfaces may play an important role. The high-resolution liquid chromatography–electrospray ionization–mass spectrometric analysis of filter extracts of unprocessed AS + GAld seed particles identified sugar-like C 6 and C 12 GAld oligomers, including proposed product 3-deoxyglucosone, with and without modification by reactions with ammonia to diimine and imidazole forms. Chamber exposure to methylamine gas, cloud processing, and simulated sunlight increased the incorporation of both ammonia and methylamine into oligomers. Many C 4 –C 16 imidazole derivatives were detected in an extract of chamber-exposed aerosol along with a predominance of N-derivatized C 6 and C 12 glycolaldehyde oligomers, suggesting that GAld is capable of forming brown carbon SOA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel energy balance approach for a verifiable and accurate solution of radiation extinction in purely absorbing particle clouds

Here we consider the problem of radiation transport through purely absorbing particle clouds. The gold-standard solution of particle-resolved Monte Carlo ray-tracing method to this problem is computationally expensive and therefore solving the radiation transport equation (specifically, the Beer-Bouguer law (BB-law)) on a Eulerian mesh is often preferred. While the absorption coefficient in the real problem is infinite, the BB-law approximates it to be a finite number in the form of number density through a set of assumptions. For particle clouds that do not obey these assumptions, the BB-law predicts an incorrect exponential decay. Also, when the number density is computed using the nearest-neighbor approach, the BB-law solution diverges when the Eulerian mesh size becomes closer to or smaller than the particle size. This numerical divergence is due to the homogenization error. Although the filtering strategy for number density minimizes the homogenization error, it still converges to an incorrect exponential decay for particle clouds that break the BB-law constraints and the cost of the filtering is equivalent to that of the gold-standard solution. In this study, we develop a novel, highly accurate, verifiable and cost-effective solution to the radiation transport equation on a Eulerian domain using an energy balance approach where we derive an expression for the absorption coefficient as a function of particle and Eulerian mesh sizes. We apply our new method to Poisson and turbulent particle clouds that violate all the BB-law constraints and show that the solution is converging upon the mesh refinement, and eventually, we recover the same gold-standard solution for a much cheaper computational cost.

42 ENGINEERING↗

Multi-Pass Quadrupole Mass Analyzer

Analysis of the composition of planetary atmospheres is one of the most important and fundamental measurements in planetary robotic exploration. Quadrupole mass analyzers (QMAs) are the primary tool used to execute these investigations, but reductions in size of these instruments has sacrificed mass resolving power so that the best present-day QMA devices are still large, expensive, and do not deliver performance of laboratory instruments. An ultra-high-resolution QMA was developed to resolve N2 +/CO+ by trapping ions in a linear trap quadrupole filter. Because N2 and CO are resolved, gas chromatography columns used to separate species before analysis are eliminated, greatly simplifying gas analysis instrumentation. For highest performance, the ion trap mode is used. High-resolution (or narrow-band) mass selection is carried out in the central region, but near the DC electrodes at each end, RF/DC field settings are adjusted to allow broadband ion passage. This is to prevent ion loss during ion reflection at each end. Ions are created inside the trap so that low-energy particles are selected by low-voltage settings on the end electrodes. This is beneficial to good mass resolution since low-energy particles traverse many cycles of the RF filtering fields. Through Monte Carlo simulations, it is shown that ions are reflected at each end many tens of times, each time being sent back through the central section of the quadrupole where ultrahigh mass filtering is carried out. An analyzer was produced with electrical length orders of magnitude longer than its physical length. Since the selector fields are sized as in conventional devices, the loss of sensitivity inherent in miniaturizing quadrupole instruments is avoided. The no-loss, multi-pass QMA architecture will improve mass resolution of planetary QMA instruments while reducing demands on the RF electronics for high-voltage/high-frequency production since ion transit time is no longer limited to a single pass. The QMA-based instrument will thus give way to substantial reductions of the mass of flight instruments.

Prestage, John D.↗