Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The future of primordial features with large-scale structure surveys

Primordial features are one of the most important extensions of the Standard Model of cosmology, providing a wealth of information on the primordial Universe, ranging from discrimination between inflation and alternative scenarios, new particle detection, to fine structures in the inflationary potential. We study the prospects of future large-scale structure (LSS) surveys on the detection and constraints of these features. We classify primordial feature models into several classes, and for each class we present a simple template of power spectrum that encodes the essential physics. We study how well the most ambitious LSS surveys proposed to date, including both spectroscopic and photometric surveys, will be able to improve the constraints with respect to the current Planck data. We find that these LSS surveys will significantly improve the experimental sensitivity on features signals that are oscillatory in scales, due to the 3D information. For a broad range of models, these surveys will be able to reduce the errors of the amplitudes of the features by a factor of 5 or more, including several interesting candidates identified in the recent Planck data. Therefore, LSS surveys offer an impressive opportunity for primordial feature discovery in the next decade or two. We also compare the advantages of both types of surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

The BUTTON-30 detector at Boulby

The BUTTON-30 detector is a 30-tonne technology demonstrator designed to evaluate the potential of hybrid event detection, simultaneously exploiting both Cherenkov and scintillation light to detect particles produced in neutrino interactions. The detector is installed at a depth of 1.1 km in the Boulby Underground Laboratory allowing to test the performance of this new technology underground in a low background environment. This paper describes the design and construction of the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonstatistical fluctuations in the 35 Cl(n,p) 35 S reaction cross section at fast-neutron energies from 0.6 to 6 MeV

The lack of experimental data on the 35 Cl(n,p) 35 S reaction above 100 keV has led to nuclear data evaluations that are relatively unconstrained at fast neutron energies. As a result, efforts to explore, develop, and potentially certify next generation reactor designs that incorporate chloride salts as a coolant material have been hindered. Here, we report partial cross section data for the 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reactions at incident neutron energies between 0.6 MeV and 6 MeV. The measurement was performed using the pulsed beam of neutrons at the unmoderated WNR spallation neutron source at the Los Alamos Neutron Science Center, with the outgoing charged particles detected by the LENZ experimental setup, consisting of annular silicon detectors. Nonstatistical fluctuations in the 35 Cl(n,p 0 ) cross section were observed up to around 3 MeV, and the magnitude of the cross section was systematically lower than all available data evaluations at energies above 1 MeV. Modifications to the ENDF/B-VIII.0 data evaluation are suggested to better reproduce the energy averaged experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Centrality determination with a forward detector in the RHIC Beam Energy Scan

Recently, Chatterjee et al [1] used a hadronic transport model to estimate the resolution with which various experimental quantities select the impact parameter of relativistic heavy ion collisions at collision energies relevant to the Beam Energy Scan (BES) program at the Relativistic Heavy Ion Collider (RHIC). Measures based on particle multiplicity at forward rapidity were found to be significantly worse than those based on midrapidity multiplicity. Using the same model, we show that a slightly more sophisticated measure greatly improves the resolution based on forward rapidity particles; this improvement persists even when the model is filtered through a realistic simulation of a recent upgrade detector to the STAR experiment. Furthermore, these results highlight the importance of optimizing centrality measures based on particles detected at forward rapidity, especially for experimental studies that search for a critical point in the QCD phase diagram. Such measurements usually focus on proton multiplicity fluctuations at midrapidity, hence selecting events based on multiplicity at midrapidity raises the possibility of nontrivial autocorrelations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deblurring for nuclei: 3D characteristics of heavy-ion collisions

Observables from nuclear and high-energy experiments can be degraded by detector performance and/or methodology in extracting the observables, such as of the final-state characteristics of heavy-ion collisions in relation to a coarsely estimated reaction-plane direction. We propose the use of deblurring methods, such as in optics, to correct for observable degradation. Our main focus is the restoration of triple-differential particle distributions in heavy-ion collisions. We demonstrate that these could be extracted from collision measurements following the Richardson-Lucy deblurring method from optics. We illustrate basic features of the restoration methodology in a schematic model assuming either ideal or more realistic particle detection. Here, the inferred three-dimensional (3D) distributions for collisions may be easier to interpret in terms of collision dynamics and sought properties of bulk matter than the currently employed Fourier coefficients, that combine information from different azimuthal angles relative to the reaction plane.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the decay branching ratios of the {alpha}-unbound states in {sup 19}Ne and the {sup 15}O({alpha},{gamma}) reaction rate

The breakout reaction {sup 15}O({alpha},{gamma}){sup 19}Ne from the hot CNO cycle is critical to understanding explosive astrophysical phenomena such as x-ray bursts. In spite of considerable past experimental effort via indirect methods, this reaction rate remained mostly uncertain until our recent measurement [Phys. Rev. Lett. 98, 242503 (2007)] of the eluding {alpha}-decay branching ratios of the near-threshold states in {sup 19}Ne, particularly the critical level at 4.03 MeV. In this paper, we present more details of and deeper insights into the measurement and the uncertainties of the experimental results. The {alpha}-unbound states in {sup 19}Ne were populated via the reaction {sup 19}F({sup 3}He,t), and the {alpha}-decay branch was observed from t-{alpha} coincidences using a low-energy particle detection array and the TWINSOL facility at the University of Notre Dame. In particular, the measured branching ratio of the 4.03-MeV state is 2.9{+-}2.1x10{sup -4}. In combination with previous measurements of the lifetimes of these states, a new experimental reaction rate of {sup 15}O({alpha},{gamma}){sup 19}Ne is proposed and discussed in the astrophysical scenario. Further experimental investigations are necessary to reduce the remaining uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of superdeformed bands in {sup 62}Zn

Combined data from four fusion-evaporation reaction experiments were utilized to investigate deformed and superdeformed structures in {sub 30}{sup 62}Zn{sub 32}. Combination of the Gammasphere {gamma}-ray spectrometer and ancillary particle detection systems allowed for the connection of rotational bands to well-known, low-lying excited states in {sup 62}Zn, as well as spectroscopy of discrete high-spin states reaching excitation energies of E{sub x}=42.5 MeV. Four well- or superdeformed bands in {sup 62}Zn are characterized and described by means of cranked Nilsson-Strutinsky calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiparticle azimuthal correlations for extracting event-by-event elliptic and triangular flow in Au + Au collisions at s N N = 200 GeV

Here, we present measurements of elliptic and triangular azimuthal anisotropy of charged particles detected at forward rapidity 1 < |η| < 3 in Au + Au collisions at √ s NN = 200 GeV, as a function of centrality. The multiparticle cumulant technique is used to obtain the elliptic flow coefficients v 2 {2}, v 2 {4}, v 2 {6}, and v 2 {8}, and triangular flow coefficients v3{2} and v3{4}. Using the small-variance limit, we estimate the mean and variance of the event-by-event v 2 distribution from v 2 {2} and v 2 {4}. In a complementary analysis, we also use a folding procedure to study the distributions of v 2 and v 3 directly, extracting both the mean and variance. Implications for initial geometrical fluctuations and their translation into the final-state momentum distributions are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Velo and REXAN - Integrated Data Management and High Speed Analysis for Experimental Facilities

The Chemical Imaging Initiative at the Pacific Northwest National Laboratory (PNNL) is creating a ‘Rapid Experimental Analysis’ (REXAN) Framework, based on the concept of reusable component libraries. REXAN allows developers to quickly compose and customize high throughput analysis pipelines for a range of experiments, as well as supporting the creation of multi-modal analysis pipelines. In addition, PNNL has coupled REXAN with its collaborative data management and analysis environment Velo to create an easy to use data management and analysis environments for experimental facilities. This paper will discuss the benefits of Velo and REXAN in the context of three examples: PNNL High Resolution Mass Spectrometry - reducing analysis times from hours to seconds, and enabling the analysis of much larger data samples (100KB to 40GB) at the same time · ALS X-Ray tomography - reducing analysis times of combined STXM and EM data collected at the ALS from weeks to minutes, decreasing manual work and increasing data volumes that can be analysed in a single step ·Multi-modal nano-scale analysis of STXM and TEM data - providing a semi automated process for particle detection The creation of REXAN has significantly shortened the development time for these analysis pipelines. The integration of Velo and REXAN has significantly increased the scientific productivity of the instruments and their users by creating easy to use data management and analysis environments with greatly reduced analysis times and improved analysis capabilities.

Kleese van Dam, Kerstin↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

A 24-Channel Digitizer With a JESD204B-Compliant Serial Interface for High-Speed Detectors

In this report a 24-channel application-specific integrated circuit (ASIC) for the readout of high-speed CMOS active pixel sensors for charged particle detection is presented. The chip comprises 24 preamplifiers, 24 distinct 12-bit, 25 MSPS Pipelined analog-to-digital converters (ADCs) with self-calibration, an internal phase-locked loop (PLL), and a 3 Gbps serial interface that conforms to the JESD204B standard. To simplify interfacing with a variety of sensors, the ASIC also includes an automatic offset calibration loop. The high level of integration of the ASIC reduces overall system cost and area, and exploiting the signal characteristics of the image sensor allows the ADC to be optimized for reduced power dissipation. The use of an integrated serializer and an industry standard protocol simplifies integration of the ASIC into a complete camera system. The ASIC, called the High-Speed Image Preprocessor Targeted for Electron Readout, or HIPSTER, with a die area of 64.26 mm 2 , is packaged in a 480-ball grid array (BGA) and is fabricated in 180-nm CMOS technology. HIPSTER achieves typical differential nonlinearity (DNL) < 0.55 LSB, input-referred thermal noise of $114.5 μV-rms, and a bit error rate (BER) of better than 10-14. The power dissipation is 98 mW/channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume

Purpose: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination of the MD active surface area and active volume. Methods: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. Results: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in the 2D response maps. Conclusions: The obtained results demonstrate the high reproducibility of the MD fabrication process. The observed discrepancies among the output correction factors reported by several authors for MD response in very small fields are very unlikely to be ascribed to unintentional variations of the device active surface area and volume. It is the opinion of the authors that the role of the volume averaging as well as of other perturbation effects should be separately investigated instead, both experimentally and by Monte Carlo simulations, in order to better clarify the behaviour of the MD response in very small fields.

60 APPLIED LIFE SCIENCES↗

Superfluid {sup 3}He, a two-fluid system, with the normal-fluid dynamics dominated by Andreev reflection

As a specific offering towards his festschrift, we present a review the various properties of the excitation gas in superfluid {sup 3}He, which depend on Andreev reflection. This phenomenon dominates many of the properties of the normal fluid, especially at the lowest temperatures. We outline the ideas behind this dominance and describe a sample of the many experiments in this system which the operation of Andreev reflection has made possible, from temperature measurement, particle detection, vortex imaging to cosmological analogues.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The ratio R{sub dp} of the quasielastic nd {yields} p(nn) to the elastic np {yields} pn charge-exchange-process yields at the proton emitting angle {theta}{sub p,lab} = 0 deg. over 0.55-2.0 GeV neutron beam energy region. Experimental results

New experimental results on ratio R{sub dp} of the quasielastic charge-exchange yield at the outgoing proton angle {theta}{sub p,lab} = 0 deg. for the nd {yields} p(nn) reaction to the elastic np {yields} pn charge-exchange yield, are presented. The measurements were carried out at the Nuclotron of the Veksler and Baldin Laboratory of High Energies of the JINR (Dubna) at the neutron-beam kinetic energies of 0.55, 0.8, 1.0, 1.2, 1.4, 1.8, and 2.0 GeV. The intense neutron beam with small momentum spread was produced by breakup of deuterons which were accelerated and extracted to the experimental hall. In both reactions mentioned above the outgoing protons with the momenta p{sub p} approximately equal to the neutron-beam momentum p{sub n,beam} were detected in the directions close to the direction of incident neutrons, i.e., in the vicinity of the scattering angle {theta}{sub p,lab} = 0 deg. Measured in the same data-taking runs, the angular distributions of the charge-exchange-reaction products were corrected for the well-known instrumental effects and averaged in the vicinity of the incident-neutron-beam direction. These corrected angular distributions for every of nd {yields} p(nn) and np {yields} pn charge-exchange processes were proportional to the differential cross sections of the corresponding reactions. The data were accumulated by Delta-Sigma setup magnetic spectrometer with two sets of multiwire proportional chambers located upstream and downstream of the momentum analyzing magnet. Inelastic processes were considerably reduced by the additional detectors surrounding the hydrogen and deuterium targets. The time-of-flight system was applied to identify the detected particles. The accumulated data treatment and analysis, as well as possible sources of the systematic errors are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Possibilities of Probe Detection of Anisotropic Charged-Particle Distribution Functions in an Arbitrary-Symmetry Plasma

We have analyzed the precision and systematic errors of the familiar method of a plane single-ended probe for measuring the anisotropic distribution functions for electrons and ions in plasma. Analytic relations that connect the plasma parameters and the required number of terms in a series are obtained under the conditions when anisotropy is due to the presence of an electric field in the plasma. It has been shown that ten terms of the series are usually sufficient to adequately describe the ion distribution function, except for the case of strong fields. For strongly anisotropic charged particle distribution functions, the spline interpolation technique for experimental data is proposed and tested, which substantially reduces the systematic error for a preset number of terms in the series. It has been shown for abundant actual plasma objects with the mirror symmetry that the number of required orientations of a plane probe for the experimental distribution function can be reduced by half compared to the most general case of the absence of any symmetry for a fixed number of terms in the Legendre series, while for the same number of orientations, the number of terms in the series, which are determined from these measurements, doubled accordingly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design concept for a second interaction region for the Electron-Ion Collider

In addition to the day-one primary Interaction Region (IR), the design of the Electron Ion Collider (EIC) must support operation of a 2nd IR potentially added later. The 2nd IR is envisioned in an existing experimental hall at RHIC IP8, compatible with the same beam energy combinations as the 1st IR over the full center of mass energy range of ~20 GeV to ~140 GeV. The 2nd IR is designed to be complementary to the 1st IR. In particular, a secondary focus is added in the forward ion direction of the 2nd IR hadron beamline to optimize its capability in detecting particles with magnetic rigidities close to those of the ion beam. We provide the current design status of the 2nd IR in terms of parameters, magnet layout and beam dynamics.

Gamage, B. R.↗

Multiscale Toxicology - Building the Next Generation Tools for Toxicology

A Cooperative Research and Development Agreement (CRADA) was sponsored by Battelle Memorial Institute (Battelle, Columbus), to initiate a collaborative research program across multiple Department of Energy (DOE) National Laboratories aimed at developing a suite of new capabilities for predictive toxicology. Predicting the potential toxicity of emerging classes of engineered nanomaterials was chosen as one of two focusing problems for this program. PNNL’s focus toward this broader goal was to refine and apply experimental and computational tools needed to provide quantitative understanding of nanoparticle dosimetry for in vitro cell culture systems, which is necessary for comparative risk estimates for different nanomaterials or biological systems. Research conducted using lung epithelial and macrophage cell models successfully adapted magnetic particle detection and fluorescent microscopy technologies to quantify uptake of various forms of engineered nanoparticles, and provided experimental constraints and test datasets for benchmark comparison against results obtained using an in vitro computational dosimetry model, termed the ISSD model. The experimental and computational approaches developed were used to demonstrate how cell dosimetry is applied to aid in interpretation of genomic studies of nanoparticle-mediated biological responses in model cell culture systems. The combined experimental and theoretical approach provides a highly quantitative framework for evaluating relationships between biocompatibility of nanoparticles and their physical form in a controlled manner.

Thrall, Brian D.↗