Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle stack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

SU-E-T-193: FMEA Severity Scores - Do We Really Know?

Purpose: Mycosis fungoides is a common form of cutaneous T-cell lymphoma which generally affects the skin. A typical course of treatment may include fractionated total skin electron beam therapy. Given the difficulties in uniformly irradiating some regions of the body and the need for frequent visits within the context of a fractionated protocol, this study investigated the feasibility of delivering the dose using form-fitting cloth which contained phosphorous-32 as a source for beta particle irradiation. Methods: A piece of fabric (0.97 g) consisting of a blend of spandex and flame retardant material impregnated with phosphorus-31 (2000 ppm) was bombarded with neutrons to produce phosphorus-32. The cloth was then laid flat and a stack of radiochromic film placed on top. Sheets of film and tissue equivalent plastic were layered to form a stack measuring a total of 1 cm thickness and remained sandwiched for 77.3 hr. Results: The initial activity of the activated cloth was 44 μCi of P-32. The absorbed dose was uniform within planes parallel to the cloth and exponentially dependent on depth, delivering 560cGy at 0.3mm and falling to 20cGy at 3mm. Conclusion: The total dose prescribed for a typical course of TSET for mycosis fungoides is 36Gy delivered over 9 weeks and is expected to treat to at least 5mm depth. Therefore, the P-32 impregnated cloth may not be clinically indicated to treat this disease given the unfavorable depth-dose characteristics. However, a major advantage of using form-fitting cloth is the uniformity with which the dose could be delivered over the skin in areas which are not flat. Increasing the distance between cloth and skin could improve the depth-dose characteristics.

07 ISOTOPE AND RADIATION SOURCES↗

Multi-Physics Coupling to Model a RbCl-RbCl-Ga Target Stack

A computational model has been developed to simulate the performance of the Los Alamos Isotope Production Facility's (IPF) routine production target configuration, which consists of two Inconel-encapsulated RbCl salt targets and one niobium-encapsulated gallium target separated by water cooling channels. The methodology involves iteratively coupling particle transport and thermal hydraulic codes to determine the time dependent behavior of the target. Phase and density changes seen in targets are known to impact beam penetration and distribution. In addition, evidence of energy distributions seen in experimental radionuclide yield measurements at IPF do not match those seen in previous MCNP predictions. Density reduction as a result of heat deposition affects proton energy loss along the particle's track, impacting both radionuclide yields and target design. Accurate modeling of the thermal behavior of these multi-phase targets and the corresponding impact on beam behavior will significantly improve our understanding of incident and exit proton energy distributions and resulting radionuclide yields in downstream targets. Thermal hydraulic modeling, including computational fluid dynamics (CFD) and heat transfer, was performed with ANSYS CFX while particle transport was performed with the Monte Carlo N-Particle code (MCNP). (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Micro-aligned 1 Tesla Solenoid for High-energy Bunched-beam Electron Cooling

Electron cooling of ion beams requires precise alignment of the electron beam with the equilibrium trajectory of the ion bunch. In magnetized cooling the cooling rate is enhanced by transverse confinement of each electron on a magnetic line of force. The magnetic lines of force must therefore be aligned with the ion bunch trajectory everywhere along the extent of the solenoid. For the parameters required for JLEIC, a solenoid with bore field ~1 T, length ~30 m, and rms alignment of ~micro-radian is required. Such alignment has never been accomplished. The design of a micro-aligned solenoid is presented. A gap-separated stack of thin steel washers is located along the bore of the solenoid. The flux plate stack shields transverse magnetic fields from the interior, so that axial alignment is enhanced by a factor of ~10.

43 PARTICLE ACCELERATORS↗

A study of defects on EUV mask using blank inspection, patterned mask inspection, and wafer inspection

The availability of defect-free masks remains one of the key challenges for inserting extreme ultraviolet lithography (EUVL) into high volume manufacturing. yet link data is available for understanding native defects on real masks. In this paper, a full-field EUV mask is fabricated to investigate the printability of various defects on the mask. The printability of defects and identification of their source from mask fabrication to handling were studied using wafer inspection. The printable blank defect density excluding particles and patterns is 0.63 cm{sup 2}. Mask inspection is shown to have better sensitivity than wafer inspection. The sensitivity of wafer inspection must be improved using through-focus analysis and a different wafer stack.

36 MATERIALS SCIENCE↗

Fabrication of submicron La{sub 2-x}Sr{sub x}CuO{sub 4} intrinsic Josephson junction stacks

Intrinsic Josephson junction (IJJ) stacks of cuprate superconductors have potential to be implemented as intrinsic phase qubits working at relatively high temperatures. We report success in fabricating submicron La{sub 2-x}Sr{sub x}CuO{sub 4} (LSCO) IJJ stacks carved out of single crystals. We also show a new fabrication method in which argon ion etching is performed after focused ion beam etching. As a result, we obtained an LSCO IJJ stack in which resistive multibranches appeared. It may be possible to control the number of stacked IJJs with an accuracy of a single IJJ by developing this method.

36 MATERIALS SCIENCE↗

Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.

sample conditioning↗

Gamma Rays from Fast Black-hole Winds

We study massive black holes at the centers of galaxies that can launch powerful wide-angle winds that, if sustained over time, can unbind the gas from the stellar bulges of galaxies. These winds may be responsible for the observed scaling relation between the masses of the central black holes and the velocity dispersion of stars in galactic bulges. Propagating through the galaxy, the wind should interact with the interstellar medium creating a strong shock, similar to those observed in supernovae explosions, which is able to accelerate charged particles to high energies. In this work we use data from the Fermi Large Area Telescope to search for the γ-ray emission from galaxies with an ultrafast outflow (UFO): a fast (v ~0.1 c), highly ionized outflow, detected in absorption at hard X-rays in several nearby active galactic nuclei (AGN). Adopting a sensitive stacking analysis we are able to detect the average γ-ray emission from these galaxies and exclude that it is due to processes other than UFOs. Moreover, our analysis shows that the γ-ray luminosity scales with the AGN bolometric luminosity and that these outflows transfer ~0.04% of their mechanical power to γ-rays. Interpreting the observed γ-ray emission as produced by cosmic rays (CRs) accelerated at the shock front, we find that the γ-ray emission may attest to the onset of the wind–host interaction and that these outflows can energize charged particles up to the transition region between galactic and extragalactic CRs.

79 ASTRONOMY AND ASTROPHYSICS↗

Attempt at dust debris collection with stacked detectors (A0138-2)

The primary objective of this experiment is to investigate the feasibility of future missions of multilayer thin-film detectors acting as energy sorter to collect micrometeoroids, if not in their original shape, at least as fragments suitable for chemical analysis. It is expected that this kind of particle collector will help in solving one of the most puzzling topics in cosmic-dust studies: the mineralogical and chemical composition of the particles. This is a matter of great interest in the study of the origin and evolution of the solar system.

Mandeville, J. C.↗

Plasma boundary shape control and real-time equilibrium reconstruction on NSTX-U

Here, the upgrade to the National Spherical Torus eXperiment (NSTX-U) included two main improvements: a larger center-stack, enabling higher toroidal field and longer pulse duration, and the addition of three new tangentially aimed neutral beam sources, which increase available heating and current drive, and allow for flexibility in shaping power, torque, current, and particle deposition profiles. To best use these new capabilities and meet the high-performance operational goals of NSTX-U, major upgrades to the NSTX-U control system (NCS) hardware and software have been made. Several control algorithms, including those used for real-time equilibrium reconstruction and shape control, have been upgraded to improve and extend plasma control capabilities. As part of the commissioning phase of first plasma operations, the shape control system was tuned to control the boundary in both inner-wall limited and diverted discharges. It has been used to accurately track the requested evolution of the boundary (including the size of the inner gap between the plasma and central solenoid, which is a challenge for the ST configuration), X-point locations, and strike point locations, enabling repeatable discharge evolutions for scenario development and diagnostic commissioning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma boundary shape control and real-time equilibrium reconstruction on NSTX-U

The upgrade to the National Spherical Torus eXperiment (NSTX-U) included two main improvements: a larger center-stack, enabling higher toroidal field and longer pulse duration, and the addition of three new tangentially aimed neutral beam sources, which increase available heating and current drive, and allow for flexibility in shaping power, torque, current, and particle deposition profiles. To best use these new capabilities and meet the high-performance operational goals of NSTX-U, major upgrades to the NSTX-U Control System (NCS) hardware and software have been made. Several control algorithms, including those used for real-time equilibrium reconstruction and shape control, have been upgraded to improve and extend plasma control capabilities. As part of the commissioning phase of first plasma operations, the shape control system was tuned to control the boundary in both inner-wall limited and diverted discharges. It has been used to accurately track the requested evolution of the boundary (including the size of the inner gap between the plasma and central solenoid, which is a challenge for the ST configuration), X-point locations, and strike point locations, enabling repeatable discharge evolutions for scenario development and diagnostic commissioning.

Boyer, M↗

Towards a high performance geometry library for particle-detector simulations

Thread-parallelization and single-instruction multiple data (SIMD) ”vectorisation” of software components in HEP computing has become a necessity to fully benefit from current and future computing hardware. In this context, the Geant-Vector/GPU simulation project aims to re-engineer current software for the simulation of the passage of particles through detectors in order to increase the overall event throughput. As one of the core modules in this area, the geometry library plays a central role and vectorising its algorithms will be one of the cornerstones towards achieving good CPU performance. Here, we report on the progress made in vectorising the shape primitives, as well as in applying new C++ template based optimizations of existing code available in the Geant4, ROOT or USolids geometry libraries. We will focus on a presentation of our software development approach that aims to provide optimized code for all use cases of the library (e.g., single particle and many-particle APIs) and to support different architectures (CPU and GPU) while keeping the code base small, manageable and maintainable. We report on a generic and templated C++ geometry library as a continuation of the AIDA USolids project. As a result, the experience gained with these developments will be beneficial to other parts of the simulation software, such as for the optimization of the physics library, and possibly to other parts of the experiment software stack, such as reconstruction and analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location

Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Exhaust Stack. The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow -angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Exhaust Stack. The 3430 stack was tested in both January and May of 2010 to document the results of several changes that were made to the exhaust system after the January tests. The 3430 stack meets the qualification criteria given in the American National Standards Institute/Health Physics Society N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliancewith the requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of the Building 3430 Filtered Exhaust Stack Sampling Probe Location

Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Pathway Stack . The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Pathway stack. Therefore, this new system also meets the qualification criteria given in the ANSI/HPS N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliance to the requirements.

54 ENVIRONMENTAL SCIENCES↗

A High Resolution Phoswich Detector: LaBr{sub 3}(Ce) Coupled With LaCl{sub 3}(Ce)

An innovative solution for the forward end-cap CALIFA calorimeter of R{sup 3}B is under investigation consisting of two scintillation crystals, LaBr{sub 3} and LaCl{sub 3}, stacked together in a phoswich configuration with one readout only. This dispositive should be capable of a good determination of the energy of protons and gamma radiation. This composite detector allows to deduce the initial energy of charged particles by DELTAE1+DELTAE2 identification. For gammas, the simulations show that there is a high probability that the first interaction occurs inside the scintillator at few centimeters, with a second layer, the rest of the energy is absorbed, or it can be used as veto event in case of no deposition in the first layer. One such a detector has been tested at the Centro de MicroAnalisis de Materiales (CMAM) in Madrid. Good resolution and time signal separation have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of Corner Modes in the Initial Conditions of Cosmological Simulations

In view of future high-precision large-scale structure surveys, it is important to quantify the percent and subpercent level effects in cosmological N-body simulations from which theoretical predictions are drawn. One such effect involves deciding whether to zero all modes above the one-dimensional Nyquist frequency, the so-called “corner” modes, in the initial conditions. We investigate this effect by comparing power spectra, density distribution functions, halo mass functions, and halo profiles in simulations with and without these modes. For a simulation with a mass resolution of m{sub p}∼10{sup 11} h{sup −1} M{sub ⊙}, we find that at z>6, the difference in the matter power spectrum is large at wavenumbers above ∼80% of k{sub Ny}, reducing to below 2% at all scales by z∼3. Including corner modes results in a better match between low- and high-resolution simulations at wavenumbers around the Nyquist frequency of the low-resolution simulation, but the effect of the corner modes is smaller than the effect of particle discreteness. The differences in mass functions are 3% for the smallest halos at z = 6 for the m{sub p}∼10{sup 11} h{sup −1} M{sub ⊙} simulation, but we find no significant difference in the stacked profiles of well-resolved halos at z⩽6. Thus removing power at |k|>k{sub Ny} in the initial conditions of cosmological simulations has a small effect on small scales and high redshifts, typically below a few percent.

79 ASTRONOMY AND ASTROPHYSICS↗

Heavy ion measurement on LDEF

Heavy ions with nuclear charge Z = 6 to Z = 26 are detected in a stack of plastic track detectors. The measured energies in the range of 10-240 MeV/nuc are well below the geomagnetic cut off value of the Long Duration Exposure Facility (LDEF) orbit. The arrival directions of the low energy particles (Z = 6-26, E less than 40 MeV/nuc) are consistent with a trapped component incident in the South Atlantic Anomaly.

Jonathal, D.↗

Three-Dimensional Simulations of Electron Beams Focused by Periodic Permanent Magnets

A fully three-dimensional (3D) model of an electron beam focused by a periodic permanent magnet (PPM) stack has been developed. First, the simulation code MAFIA was used to model a PPM stack using the magnetostatic solver. The exact geometry of the magnetic focusing structure was modeled; thus, no approximations were made regarding the off-axis fields. The fields from the static solver were loaded into the 3D particle-in-cell (PIC) solver of MAFIA where fully 3D behavior of the beam was simulated in the magnetic focusing field. The PIC solver computes the time-integration of electromagnetic fields simultaneously with the time integration of the equations of motion of charged particles that move under the influence of those fields. Fields caused by those moving charges are also taken into account; thus, effects like space charge and magnetic forces between particles are fully simulated. The electron beam is simulated by a number of macro-particles. These macro-particles represent a given charge Q amounting to that of several million electrons in order to conserve computational time and memory. Particle motion is unrestricted, so particle trajectories can cross paths and move in three dimensions under the influence of 3D electric and magnetic fields. Correspondingly, there is no limit on the initial current density distribution of the electron beam, nor its density distribution at any time during the simulation. Simulation results including beam current density, percent ripple and percent transmission will be presented, and the effects current, magnetic focusing strength and thermal velocities have on beam behavior will be demonstrated using 3D movies showing the evolution of beam characteristics in time and space. Unlike typical beam optics models, this 3D model allows simulation of asymmetric designs such as non- circularly symmetric electrostatic or magnetic focusing as well as the inclusion of input/output couplers.

Kory, Carol L.↗

Surface modification of ZIF ‐90 with triptycene for enhanced interfacial interaction in mixed‐matrix membranes for gas separation

Abstract Zeolite imidazole framework (ZIF‐90) nanoparticles were chemically modified by grafting triptycene moieties. The modified nanoparticles were introduced into a triptycene‐based polyimide as fillers to generate mixed matrix membranes (MMMs) for gas separation. The incorporation of “hook‐like” triptycene moieties in both dispersed and continuous phases led to intimate contact between the two phases and thus defect‐free interfacial morphology, due to the supramolecular interlocking and π–π stacking interaction between triptycene units presented in both phases. The filler/polymer solution showed shear thickening behavior due to such strong interfacial interaction. The separation performance of the prepared composite membranes was investigated as a function of filler loading and particle surface grafting density. Pure‐gas permeation results showed that the gas permeabilities increased expectedly as the filler loading increased, with stable or improved selectivities. The reduced permeability relative to pristine polyimide film is likely due to the pore blockage of ZIF‐90 upon grafting triptycene moieties on the particle surface. Reducing the grafting density of triptycene moieties led to improved permeability and selectivity suggesting good tunability of this series of new composite membranes. Overall, modification of nanofiller with hierarchical triptycene moieties offers a fundamentally new avenue for creation of composite membranes with unique properties in gas separations.

Zhang, Qinnan↗