Search NASA⌕ Search

SEARCH · Search NASA

Results for “Periodic Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Observations of joule and particle heating in the auroral zone

Observational data from the Chatanika, Alaska incoherent scatter radar have been used to deduce atmospheric heating rates associated with particle precipitation and joule dissipation. During periods when Chatanika is in the vicinity of the auroral oval the height-integrated heat input to the lower thermosphere can be as large as 100 ergs per sq cm per sec with joule and particle heating rates of comparable magnitude. Altitude profiles of these heat inputs are also obtained, showing that the energy liberated by joule dissipation tends to peak at a substantially higher altitude (about 130 km) than that due to particles (100-120 km). As a consequence, it follows that joule heating can be expected to provide a rapid means for creating thermospheric disturbances. It is also pointed out that joule and particle heating are permanent features of the auroral oval and polar cap. As such, expansion of the auroral oval leads to an increase in the total global heating and, hence, to the close relationship between magnetic disturbances and thermospheric perturbation.

Banks, P. M.↗

Physical processes determining the chromospheric temperature distribution

It is demonstrated that short period acoustic waves appear adequate to heat the low chromosphere in the region just above the temperature minimum, these waves are unlikely to provide sufficient energy to heat the chromosphere above tau-5000 A(normal) less than 10 to the -6th. Calculations also show that the electron density to H density ratio from chromospheric models is too low for the H2 molecule to affect the population of H(-).

Jordan, S. D.↗

Advanced propulsion system for hybrid vehicles

A number of hybrid propulsion systems were evaluated for application in several different vehicle sizes. A conceptual design was prepared for the most promising configuration. Various system configurations were parametrically evaluated and compared, design tradeoffs performed, and a conceptual design produced. Fifteen vehicle/propulsion systems concepts were parametrically evaluated to select two systems and one vehicle for detailed design tradeoff studies. A single hybrid propulsion system concept and vehicle (five passenger family sedan)were selected for optimization based on the results of the tradeoff studies. The final propulsion system consists of a 65 kW spark-ignition heat engine, a mechanical continuously variable traction transmission, a 20 kW permanent magnet axial-gap traction motor, a variable frequency inverter, a 386 kg lead-acid improved state-of-the-art battery, and a transaxle. The system was configured with a parallel power path between the heat engine and battery. It has two automatic operational modes: electric mode and heat engine mode. Power is always shared between the heat engine and battery during acceleration periods. In both modes, regenerative braking energy is absorbed by the battery.

Norrup, L. V.↗

The tectonics of anorthosite massifs

Anorthosite massifs developed approximately 1.4 to 1.5 billion years ago along an arch which developed parallel to a zone of continental separation as a block which included North America, Europe, and probably Asia separated from a block which included parts of South America, Africa, India, and Australia. Anorthosite massifs also developed at the same time along a belt which runs through the continents which comprise Gondwanaland (South America), Africa, India, Australia, and Antarctica. This was a zone of continental separation which subsequently became a zone of continental collision about 1.2 billion years ago. The northern anorthosite belt also parallels an orogenic belt which was active between 1.8 and 1.7 billion years ago. Heat generated during this mountain building period helped in the formation of the anorthosites.

Seyfert, C. K.↗

The use of the PUCOT for elastic modulus measurements on intermetallics at high temperatures

The piezoelectric ultrasonic composite oscillator technique (PUCOT) is being applied to measure the elastic constants of the aluminides in the temperature ranges 300 to 1700 K (CoAl and NiAl) and 300 to 1500 K (FeAl). The PUCOT consists of piezoelectric quartz drive and gauge crystals to excite longitudinal or torsional ultrasonic (80 kHz) resonant stress waves in the specimen and alumina spacer rod of appropriate resonant lengths. The resonant system is driven by a closed loop oscillator which maintains a constant gauge voltage and hence constant strain amplitude in the specimen. While the specimen is heated at 20 K/h the resonant period is measured continuously. The elastic moduli are calculated from these values of the resonant period and accurate determinations of specimen length. The technique is described and some results given.

Wolfenden, A.↗

Destabilization of a 650 km chemical boundary layer and its bearing on the evolution of the continental crust

A mechanism for the production of a chemical change in the mantle, from primordial silicate compositions above the 650 km discontinuity to differentiated compositions below, is reviewed. Some consequences of this are the stabilization of two layer convection with a temperature contrast between the anhydrous mantle solidus and the geotherm which, at 650 km depth, is lower than any other location in the mantle. With thermal contributions from the concentration of the heat producing elements U, Th and K below the 650 km mantle boundary layer and the higher geotherms in the past, widespread or catastrophic melting may have taken place at this location. An episodic breach of this boundary layer by extensive heat and mass transport may have periodically destroyed any simple two-layer convection geometry in the mantle. Such episodic injections of mass and energy into the upper mantle from below may have been the mechanism responsible for episodes of enhanced surface tectonism and thermal activity which appear to be recorded in apparent polar wandering paths and radiometric ages of continental rocks.

Herzberg, C. T.↗

Thermogravimetric analysis of silicon carbide-silicon nitride fibers at ambient to 1000 C in air

Thermogravimetric analysis of silicon carbide-silicon nitride fibers was carried out at ambient to 1000 C in air. The weight loss over this temperature range was negligible. In addition, the oxidative stability at high temperature for a short period of time was determined. Fibers heated at 1000 C in air for fifteen minutes showed negligible weight loss (i.e., less than 1 percent).

Daniels, J. G.↗

Modulated mass-transfer model for superhumps in SU Ursae Majoris stars

The response of a circular accretion disk to rapid modulation of the mass-transfer rate into the disk is explored in order to model superhumps in SU UMa stars. It is proposed that periodically enhanced flow may disrupt or heat up the outer disk and produce the dips noted just before the superhump peaks. The elliptical accretion-disk model with extended vertical disk structure can account for the observed characteristics of superhumps in these stars.

Mineshige, Shin↗

Episodic coronal heating

A study is made of the observational consequences of the hypothesis that there is no steady coronal heating, the solar corona instead being heated episodically, such that each short burst of heating is followed by a long period of radiative cooling. The form of the resulting contribution to the differential emission measure (DEM), and to a convenient related function (the differential energy flux, DEF) is calculated. Observational data for the quiet solar atmosphere indicate that the upper branch of the DEM, corresponding to temperatures above 100,000 K, can be interpreted in terms of episodic energy injection at coronal temperatures.

Sturrock, P. A.↗

Estimates of tropical analysis differences in daily values produced by two operational centers

To assess the uncertainty of daily synoptic analyses for the atmospheric state, the intercomparison of three First GARP Global Experiment level IIIb datasets is performed. Daily values of divergence, vorticity, temperature, static stability, vertical motion, mixing ratio, and diagnosed diabatic heating rate are compared for the period of 26 January-11 February 1979. The spatial variance and mean, temporal mean and variance, 2D wavenumber power spectrum, anomaly correlation, and normalized square difference are employed for comparison.

Kasahara, Akira↗

Fast, Low-Duty-Cycle Sorption Refrigerators

Metal hydride/hydrogen-sorption refrigerators developed to provide rapid, intermittent cooling at temperatures between 30 and 10 K. In original application, refrigerators cool infrared detectors aboard spacecraft, exhausting heat to outer space via radiators at 250 K. Modified to cool scientific instrumentation on Earth with some loss of efficiency. Require no power during quick cooldown and low heating power during relatively long recharge periods.

Johnson, AL↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Packages in KAC (2021 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 16 years. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 and non3013 containers in storage from 15 years to 20 years. These calculations addressed the potential for degraded fiberboard properties following 20 years in storage using degradation models developed previously. The updated degradation models developed in this report have been compared to the assumptions in these calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 20 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 20 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC (2022 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 17 years. The aging environments include elevated temperature up to 250 °F (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models developed previously. Due to differences in containers, 9975 packages with non-3013 containers are only approved for 20 years of storage. The updated degradation models developed in this report have been compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 °F, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of non-conforming conditions such as the presence of excess moisture and mold or beetle infestations.

36 MATERIALS SCIENCE↗

2025 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Fiberboard assemblies in the 9975 package were identified as susceptible to aging and degradation under long-term storage conditions. Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 20 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models. The 40 year storage evaluations assumed the degradation rates from initial values for density, dimensional, and thermal properties were 0.5% per year (i.e., after 40 years, the density, dimensional, and thermal properties of fiberboard were 80% of its initial values). The updated degradation models developed in this report were compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, axial and radial thermal conductivities, and energy absorption remain consistent with those calculations. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are purposely high to accelerate aging. These rates relate to environments that do not exist within KAC or are postulated to only occur as upset conditions that are unlikely to persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments (i.e., under 125 °F) used in this study. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Re-Examination of the Observed Decadal Variability of Earth Radiation Budget Using Altitude-Corrected ERBE/ERBS Nonscanner WFOV Data

This paper gives an update on the observed decadal variability of Earth Radiation Budget using the latest altitude-corrected Earth Radiation Budget Experiment (ERBE)/Earth Radiation Budget Satellite (ERBS) Nonscanner Wide Field of View (WFOV) instrument Edition3 dataset. The effects of the altitude correction are to modify the original reported decadal changes in tropical mean (20N to 20S) longwave (LW), shortwave (SW), and net radiation between the 1980s and the 1990s from 3.1/-2.4/-0.7 to 1.6/-3.0/1.4 Wm(sup -2) respectively. In addition, a small SW instrument drift over the 15-year period was discovered during the validation of the WFOV Edition3 dataset. A correction was developed and applied to the Edition3 dataset at the data user level to produce the WFOV Edition3_Rev1 dataset. With this final correction, the ERBS Nonscanner observed decadal changes in tropical mean LW, SW, and net radiation between the 1980s and the 1990s now stand at 0.7/-2.1/1.4 Wm(sup -2), respectively, which are similar to the observed decadal changes in the HIRS Pathfinder OLR and the ISCCP FD record; but disagree with the AVHRR Pathfinder ERB record. Furthermore, the observed interannual variability of near-global ERBS WFOV Edition3_Rev1 net radiation is found to be remarkably consistent with the latest ocean heat storage record for the overlapping time period of 1993 to 1999. Both data sets show variations of roughly 1.5 Wm(sup -2) in planetary net heat balance during the 1990s.

Wong, Takmeng↗

Polar Wind in the Context of the Auroral Plasma Fountain for 2 to 8 RE

Operations of the POLAR Plasma Source Instrument have provided adequate observing time with controlled spacecraft potential to begin a 3D characterization of the polar wind as it exists in the context of the auroral plasma fountain. The principal periods of such polar wind observation to date have been 15-18 Apr. 96, 28 may 96, 14 Jun. - 6 Sep. 96, 17-29 Mar. 97, 29 May - 12 Jun. 97, 13-27 Aug. 97. Separate observations have been made near 2 RE geocentric in the south polar perigee passes and between 6-8 RE geocentric in the north polar apogee passes. Analyses of data from the Thermal Ion Dynamics Experiment during these periods are used to characterize the altitude, local time, and invariant latitude distribution of the polar wind. Data from these and other periods are used to establish the auroral plasma heating context within which the polar wind outflows exist. The available data will be used to address the temporal variability of the polar wind during the period of operations to date. Comparisons between the observations and a coupled fluid-semikinetic model are used to interpret the observed spatial structure and temporal variability.

Moore, T. E.↗

IOTA Pre-Bake Test Development

The poster presentation prepared for the IOTA (Integrable Optics Test Accelerator) Pre-Bake Test Development project consists of introducing the background of the project, the work completed, and the new test configurations available with the newly designed assembly. It explains the scale of the projects, both within the IOTA ring assembly and test assembly, and describes the purpose in baking or incrementing and holding exterior heat on the beampipe to reduce impurities in the vacuum. The originally designed test, Configuration One, uses RCA scans on the interior of the pipe, increments and holds heat for a set amount of time, and is scanned again to check for water evaporation. Configuration Two begins with the same test for Configuration One but has a second cross section of beampipe separated by a gate valve. After configuration one is complete, the gate valve opens, and after a period of cooling the other side is heated, molecular movement is scanned and observed.

Seagrave, Kayla [DuPage Coll.]↗

Thermal alteration experiments on organic matter in recent marine sediments as a model for petroleum genesis

The fate of naturally occurring lipids and pigments in a marine sediment exposed to elevated temperatures was studied. Samples of a young marine sediment from Tanner Basin, California, were heated to a series of temperatures (65-200 C) for varying periods of time (7-64 days). The sediment was analyzed prior to and after heating for pigments, isoprenoid compounds, alcohols, fatty acids, and hydrocarbons. Structural changes caused by heating unextractable organic material (kerogen) were also studied, and the significance of the results for understanding petroleum genesis is considered. Among other results, fatty acids and hydrocarbons increased in abundance although there appeared to be no obvious precursor-to-product relationship via simple decarboxylation reactions. Chlorins were partially converted into porphyrins. The phytyl side chain of pheophytin was initially preserved intact by reduction of the phytyl double bond, but later converted to a variety of isoprenoid compounds including alkanes. Thermal grafting of components onto kerogen occurred as well as structural changes caused by heat.

Baedecker, M. J.↗