Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature↗

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Fabrication of a Two-Dimensional Superconducting Pop-up Bolometer Array

We have been developing an architecture for producing large format, two dimensional arrays of close-packed bolometers, which will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The low backgrounds achieved in these instruments require very sensitive detectors with NEPs of order 5 x 10(exp -18) W/square root of Hz. Superconducting transition edge sensor bolometers can be close-packed using the Pop-up Detector (PUD) format, and SQUID multiplexers operating at the detector base temperature can be intimately coupled to them. The array unit cell is 8 x 32 pixels, using 32- element detector and multiplexer components. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays. We report on the production of the 32-element components for the arrays. Planned instruments using this array architecture include the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory, the South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory, the Millimeter Bolometer Camera for the Atacama Cosmology Telescope (MBC/ACT), and the Redshift (Z) Early Universe Spectrometer (ZEUS j.

Benford, Dominic J.↗

Snowballs in Euclid and WFIRST Detectors

Snowballs are transient events observed in HgCdTe detectors with a sudden increase of charge in a few pixels. They appear between consecutive reads of the detector, after which the affected pixels return to their normal behavior. The origin of the snowballs is unknown, but it was speculated that they could be the result of alpha decay of naturally radioactive contaminants in the detectors, but a cosmic ray origin cannot be ruled out. Even though previous studies predicted a low rate of occurrence of these events, and consequently, a minimal impact on science, it is interesting to investigate the cause or causes that may generate snowballs and their impact in detectors designed for future missions. We searched for the presence of snowballs in the dark current data in Euclid and Wide Field Infrared Survey Telescope (WFIRST) detectors tested in the Detector Characterization Laboratory at Goddard Space Flight Center. Our investigation shows that for Euclid and WFIRST detectors, there are snowballs that appear only one time, and others that repeat in the same spatial localization. For Euclid detectors, there is a correlation between the snowballs that repeat and bad pixels in the operational masks (pixels that do not fulfill the requirements to pass spectroscopy noise, photometry noise, quantum efficiency, and/or linearity). The rate of occurrence for a snowball event is about 0.9 snowballs/hr. in Euclid detectors (for the ones that do not have associated bad pixels in the mask), and about 0.7 snowballs/hr. in PV3 Full Array Lot WFIRST detectors.

Astronomy↗

A Broadband Superconducting Detector Suitable for Use in Large Arrays

Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths. Single-pixel X-ray detectors now have a resolving power of (Delta)E < 5 eV for single 6-keV photons, and future X-ray astronomy missions anticipate the need for 1,000-pixel arrays. Here we report the demonstration of a superconducting detector that is easily fabricated and can readily be incorporated into such an array. Its sensitivity is already within an order of magnitude of that needed for CMB observations, and its energy resolution is similarly close to the targets required for future X-ray astronomy missions.

Day, Peter K.↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

Multi-scale time-resolved electron diffraction: A case study in moiré materials

Ultrafast-optical-pump — structural-probe measurements, including ultrafast electron and x-ray scattering, provide direct experimental access to the fundamental timescales of atomic motion, and are thus foundational techniques for studying matter out of equilibrium. High-performance detectors are needed in scattering experiments to obtain maximum scientific value from every probe particle. Here we deploy a hybrid pixel array direct electron detector to perform ultrafast electron diffraction experiments on a WSe 2 /MoSe 2 2D heterobilayer, resolving the weak features of diffuse scattering and moiré superlattice structure without saturating the zero order peak. Enabled by the detector’s high frame rate, we show that a chopping technique provides diffraction difference images with signal-to-noise at the shot noise limit. Finally, we demonstrate that a fast detector frame rate coupled with a high repetition rate probe can provide continuous time resolution from femtoseconds to seconds, enabling us to perform a scanning ultrafast electron diffraction experiment that maps thermal transport in WSe 2 /MoSe 2 and resolves distinct diffusion mechanisms in space and time.

36 MATERIALS SCIENCE↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution for the readout while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest or by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest of by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

An Efficient, FPGA-Based, Cluster Detection Algorithm Implementation for a Strip Detector Readout System in a Time Projection Chamber Polarimeter

A fundamental challenge in a spaceborne application of a gas-based Time Projection Chamber (TPC) for observation of X-ray polarization is handling the large amount of data collected. The TPC polarimeter described uses the APV-25 Application Specific Integrated Circuit (ASIC) to readout a strip detector. Two dimensional photoelectron track images are created with a time projection technique and used to determine the polarization of the incident X-rays. The detector produces a 128x30 pixel image per photon interaction with each pixel registering 12 bits of collected charge. This creates challenging requirements for data storage and downlink bandwidth with only a modest incidence of photons and can have a significant impact on the overall mission cost. An approach is described for locating and isolating the photoelectron track within the detector image, yielding a much smaller data product, typically between 8x8 pixels and 20x20 pixels. This approach is implemented using a Microsemi RT-ProASIC3-3000 Field-Programmable Gate Array (FPGA), clocked at 20 MHz and utilizing 10.7k logic gates (14% of FPGA), 20 Block RAMs (17% of FPGA), and no external RAM. Results will be presented, demonstrating successful photoelectron track cluster detection with minimal impact to detector dead-time.

Polarimeter↗

Single-mode Fiber and Few-Mode Fiber Photonic Lanterns Performance Evaluated for Use in a Scalable Real-Time Photon Counting Ground Receiver

Photonic lanterns provide an efficient way of coupling light from a single large-core fiber to multiple small-core fibers. This capability is of interest for space to ground communication applications. In these applications, the optical ground receivers require high-efficiency coupling from an atmospherically distorted focus spot to multiple fiber coupled single pixel super-conducting nanowire detectors. This paper will explore the use of photonic lanterns in a real-time ground receiver that is scalable and constructed with commercial parts. The number of small-core fibers that make a photonic lantern determines the number of spatial modes that they couple. For instance, lanterns made with n number of single-mode fibers can couple n number of spatial modes. Although the laser transmitted from a spacecraft originates as a Gaussian shape, the atmosphere distorts the beam profile by scattering energy into higher-order spatial modes. Therefore, if a ground receiver is sized for a target data rate with n number of detectors, the corresponding lantern made with single-mode fibers will couple n number of spatial modes. The energy of the transmitted beam scattered into spatial modes higher than n will be lost. This paper shows this loss may be reduced by making lanterns with few-mode fibers instead of single-mode fibers, increasing the number of spatial modes that can be coupled and therefore increasing the coupling efficiency to single pixel, single photon detectors. The free space to fiber coupling efficiency of these two types of photonic lanterns are compared over a range of the free-space coupling numerical apertures and mode field diameters. Results indicate the few mode fiber lantern has higher coupling efficiency for telescopes with longer focal lengths under higher turbulent conditions. Also presented is analysis of the jitter added to the system by the lanterns, showing the few-mode fiber photonic lantern adds more jitter than the single-mode fiber lantern, but less than a multimode fiber.

photon counting↗

Status of the Micro-X Sounding Rocket X-Ray Spectrometer

Micro-X is a sounding rocket borne X-ray telescope that utilizes transition edge sensors to perform imaging spectroscopy with a high level of energy resolution. Its 2.1m focal length X-ray optic has an effective area of 300 sq cm, a field of view of 11.8 arcmin, and a bandpass of 0.12.5 keV. The detector array has 128 pixels and an intrinsic energy resolution of 4.5 eV FWHM. The integration of the system has progressed with functional tests of the detectors and electronics complete, and performance characterization of the detectors is underway. We present an update of ongoing progress in preparation for the upcoming launch of the instrument.

X-ray astronomy↗

Ground-Based X-Ray Calibration of the Astro-H/Hitomi Soft X-Ray Telescopes

We present the summary of the on-ground calibration of two soft x-ray telescopes (SXT-I and SXT-S), developed by NASA's Goddard Space Flight Center (GSFC), onboard Astro-H/Hitomi. After the initial x-ray measurements with a diverging beam at the GSFC 100-meter beamline, we performed the full calibration of the x-ray performance, using the 30-meter x-ray beamline facility at the Institute of Space and Astronautical Science of Japan Aerospace Exploration Agency in Japan. We adopted a raster scan method with a narrow x-ray pencil beam with a divergence of approximately 15 arc secs. The on-axis effective area (EA), half-power diameter, and vignetting function were measured at several energies between 1.5 and 17.5 kiloelectronvolts. The detailed results appear in tables and figures in this paper. We measured and evaluated the performance of the SXT-S and the SXT-I with regard to the detector-limited field-of-view and the pixel size of the paired flight detector, i.e., SXS and the SXI, respectively. The primary items measured are the EA, image quality, and stray light for on-axis and off-axis sources. The accurate measurement of these parameters is vital to make the precise response function of the ASTRO-H SXTs. This paper presents the definitive results of the ground-based calibration of the ASTRO-H SXTs.

Iizuka, Ryo↗

Real-time processor for staring receivers

The design, fabrication, and testing of a state-of-the-art, high-throughput on-focal plane IR-image signal processor is described. The processing functions performed are frame differencing and thresholding. The final focal plane array will consist of a 128 x 128-pixel platinum-silicide detector bump-mounted to an on-chip CCD multiplexer. The processor is in a 128-channel parallel-pipeline format. Each channel consists of a pixel regenerator (charge differencer), 128-pixel frame store CCD memory, pixel differencer, second pixel regenerator, thresholder (analog comparator), and digital latch. Four parallel analog outputs and four parallel digital outputs are included. The digital outputs provide a bit map of the image. All analog clock signals (128 KHz, 256 KHz, and 5 MHz) are generated by on-chip TTL-input clock drivers. TTL clock driver inputs are generated off-chip. The technology is low-temperature surface and buried channel CCD/CMOS/indium bump. The design goal was 8-bit resolution at 77 K and 1000 frames/s. Applications include point- or extended-target motion detection with thresholding. Design trade-offs and enhancements (such as on-chip detector gain compensation and a simple window processor) are discussed.

Hanzal, Brian↗

Active Pixel Sensors: Are CCD's Dinosaurs?

Charge-coupled devices (CCD's) are presently the technology of choice for most imaging applications. In the 23 years since their invention in 1970, they have evolved to a sophisticated level of performance. However, as with all technologies, we can be certain that they will be supplanted someday. In this paper, the Active Pixel Sensor (APS) technology is explored as a possible successor to the CCD. An active pixel is defined as a detector array technology that has at least one active transistor within the pixel unit cell. The APS eliminates the need for nearly perfect charge transfer -- the Achilles' heel of CCDs. This perfect charge transfer makes CCD's radiation 'soft,' difficult to use under low light conditions, difficult to manufacture in large array sizes, difficult to integrate with on-chip electronics, difficult to use at low temperatures, difficult to use at high frame rates, and difficult to manufacture in non-silicon materials that extend wavelength response.

Fossum, Eric R.↗