Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Phase conjugation by four-wave mixing in inhomogeneous plasmas

The effects of density, temperature, and velocity gradients on four-wave mixing (FWM) in a plasma are investigated. A fluid model is used in which the stimulated Brillouin terms are included, but pump depletion is neglected. The steady state phase conjugate reflectivity and signal transmission coefficients are calculated and discussed for both degenerate and resonant FWM. The substantial effects of inhomogeneity on the use of FWM as a plasma diagnostic are discussed.

Williams, Edward A.↗

High-frequency instability of the sheath-plasma resonance

Coherent high frequency oscillations near the electron plasma frequency (omega approx. less than omega sub p) are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diode-like electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening and copious harmonics. The fundamental instability is a bounded oscillation due to wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres) which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line broadening mechanism was identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burst-like RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

Stenzel, R. L.↗

High-frequency instability of the sheath-plasma resonance

Coherent high-frequency oscillations near the electron plasma frequency are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diodelike electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening, and copious harmonics. The fundamental instability is a bounded oscillation caused by wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres), which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line-broadening mechanism has been identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burstlike RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

Stenzel, R. L.↗

Ion mass spectrometer measurements from the Space Shuttle

Ion-mass-spectrometer measurements made, as part of the University of Iowa's Plasma Diagnostic Package, on the STS-3 and Spacelab 2 missions, sampled a variety of positive ion composition perturbations in response to gas emissions from the vehicle. A background of contaminant ion species (mostly relating to water) always exists in the vicinity of the Shuttle. The measured number fluxes of the contaminant ions vary differently from those of the ambient ions in response to changes in the spectrometer and spacecraft angles of attack. There is a near-Shuttle wake cavity in the contaminant ion distributions which has a different spatial configuration than the wake of the ambient ions. Although water dumps produce the longest term ion perturbations, the most well defined effects were observed from measurements taken during the short firings of the reaction-control-system thrusters.

Grebowsky, J. M.↗

Advanced CCD imager technology for use from 1 to 10,000 A

A low-noise, high-sensitivity charge-coupled-device (CCD) technology for imaging applications extending from the soft X-ray (1 A) to the near-infrared (10,000 A) regimes was developed together with a fabrication technology for making back-illuminated versions of these devices with quantum efficiencies as high as 90 percent from 5000 to 7000 A. The efforts have focused on two devices, a 64 x 64 pixel back-illuminated imager with two output ports that operates at 2000 frames per second with 23 electrons read noise, and a larger device, with 420 x 420 pixel format, designed for lower frame rates with noise as low as 1.5 electrons and used at visible, UV, and X-ray wavelengths. Applications to plasma diagnostics include Thomson scattering and high-frame-rate imaging in the visible, as well as X-ray imaging and bolometry.

Twichell, J. C.↗

Collisional excitation and radiative properties of N II - The strong intercombination (1D - 3P0) transition at 748 A

Laboratory measurements of EUV emission from electron-excited N2 have been obtained at medium resolution, providing N II EUV emission cross section measurements and allowing the confirmation of recent calculations by Fawcett (1987) indicating the presence of a strong intercombination line in N II at 748.37 A. The most recently available data are used to predict the basic collisional and radiative properties of N II, the plasma diagnostic properties are briefly explored, and radiative cooling coefficients are given. Some basic properties of electron-excited N II and N2 are examined in the EUV in order to diagnose emission spectra of the earth and Titan. The N II emissions in the earth dayglow, particularly at 916 A, are much brighter than current estimates of source rates. The N II 1085 A line in the dayglow contains a significant component from dissociative photoionization excitation. The N II 1085 A, 916 A, and 670 A lines in the Titan dayglow spectrum appear to be compatible with direct electron excitation of N2.

Tripp, T. M.↗

The solar spectrum between 914 and 1177 A

A spectral line list with wavelengths and identifications for the 914-1177 A region is presented. The list is based on a Naval Research Laboratory (NRL) solar spectrum obtained from a rocket flight in 1966 and on spectra recorded by the NRL S082-B slit spectrograph flown in 1973 on the Skylab manned space station as part of the Apollo Telescope Mount. Three Skylab spectra were used for this work: a limb spectrum recorded at a position of arcsec outside the white-light limb, and two flare spectra. The wavelength list should be useful in analyzing some spectra to be obtained from the planner NASA Lyman Far Ultraviolet Spectroscopic Explorer mission. A separate table listing observed or predicted forbidden lines that fall in the 914-1177 A range is presented, and some of the plasma diagnostic possibilities for spectral lines in this range are discused.

Feldman, U.↗

Artificial electron beams in the magnetosphere and ionosphere

The Plasma Diagnostics Payload of the Echo 7 satellite carried TV cameras and photometers by means of which the luminosity around an electron beam in the polar ionosphere could be studied. It was found that, while the beam Larmor spiral could be clearly seen near 100 km, above this only a column due to suprathermal electrons was observable. At high altitudes, the emission of neutral gas both generated powerful luminosity and substantially reduced accelerator potentials. An analysis of conjugate echoes indicates that inferred magnetospheric electric fields do not map well into the ionosphere, as well as the presence of strong pitch-angle scattering.

Winckler, John R.↗

802GHz integrated horn antennas imaging array

Pattern measurements at 802GHz of a single element in 256-element integrated horn imaging array are presented. The integrated-horn antenna consists of a dipole-antenna suspended on a 1-micron dielectric membrane inside a pyramidal cavity etched in silicon. The theoretical far-field patterns, calculated using reciprocity and Floquet-modes representation of the free-space field, agree well with the measured far-field patterns at 802GHz. The associated directivity for a 1.40 lambda horn aperture, calculated from the measured E and H-plane patterns is 12.3dB + or - 0.2dB. This work demonstrates that high-efficiency integrated-horn antennas are easily scalable to terahertz frequencies and could be used for radio-astronomical and plasma-diagnostic applications.

Ali-Ahmad, Walid Y.↗

Integrated 119-micron linear corner-cube array

An integrated corner-cube antenna has been designed, fabricated, and measured at 119 microns. The structure consists of a traveling-wave antenna integrated on a 1-micron dielectric membrane and suspended in a longitudinal cavity etched in silicon wafers. The patterns at 119 microns agree well with millimeter-wave patterns measured on a scaled antenna at 222 GHz. A directivity of 18 +/- 0.5 dB is calculated from E- and H-plane measurements. This work demonstrates that high-efficiency integrated corner-cube antennas are easily scalable to terahertz frequencies and could be used for radio-astronomical and plasma-diagnostic applications.

Gearhart, Steven S.↗

Atomic oxygen beam source for erosion simulation

A device for production of low-energy (5-10 eV) neutral atomic beams for surface modification studies, which recreates the flux of atomic oxygen in LEO, is described. The beam is produced by acceleration of plasma ions onto a negatively biased plate of high-Z metal; the ions are neutralized and reflected by the surface, retaining a large fraction of their incident kinetic energy, forming a beam of atoms. The device is based on a magnetically confined (3-4 kG) coaxial plasma source and the atom energy can be varied by adjusting the bias voltage. The source provides a neutral flux of roughly 5 x 10 to the 16th/sq cm/s at a distance of 10 cm and a fluence of roughly 10 to the 21st/sq cm in five hours. The source has been characterized with plasma diagnostics and by measuring the energy of an atomic argon beam using a mass spectrometer. Samples of carbon film, carbon-based paint, Kapton, Mylar, and Teflon exposed to atomic O beams show erosion quite similar to those observed in orbit on the Space Shuttle.

Cuthbertson, J. W.↗

A comparison of three regions of Puppis A

High resolution X-ray spectral observations of Puppis A were performed with the FPCS on the Einstein Observatory at three regions of the remnant: the shock front, the bright eastern knot, and the interior. Plasma diagnostics of lines from OVII and OVIII constrain the values of electron temperature, ionization timescale, and hydrogen column density. Results of the diagnostics for these three regions are compared. A nonequilibrium analysis of previously published fluxes of oxygen lines shows that the interior has not yet reached ionization equilibrium.

Fischbach, K. F.↗

The development and test of a deformable diffraction grating for a stigmatic EUV spectroheliometer

The objectives were to address currently unanswered fundamental questions concerning the fine scale structure of the chromosphere, transition region, and corona. The unique characteristics of the spectroheliometer was used in combination with plasma diagnostic techniques to study the temperature, density, and velocity structures of specific features in the solar outer atmosphere. A unified understanding was sought of the interplay between the time dependent geometry of the magnetic field structure and the associated flows of mass and energy, the key to which lies in the smallest spatial scales that are unobservable with current EUV instruments. Toroidal diffraction gratings were fabricated and tested by a new technique using an elastically deformable substrate. The toroidal diffraction gratings was procured and tested to be used for the evaluation of the Multi-Anode Microchannel Array (MAMA) detector systems for the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) and UV Coronagraph Spectrometer (UVCS) instruments on the SOHO mission.

Timothy, J. Gethyn↗

Millimeter-wave integrated-horn antennas. I - Theory. II - Experiment

Full-wave analysis is employed to determine the far-field pattern and input impedance of a dipole-fed horn antenna in a ground plane, and the theoretical results are compared with mm-wave and microwave data. The theoretical work exploits the Green's function corresponding to the horn structure and the method of moments. It is determined that the horn should have 70 sections/wavelength and 50 secondary modes for optimized accuracy, and certain dipole positions can reduce the resonance to zero. The experimentally derived impedance and radiation patterns agree with the constraints developed theoretically. The 70-degree flare-angle horn with selected dipole positions and horn apertures yields good radiation patterns, cross-polarization levels, and resonant dipole impedances. The conclusions are of interest to the development of the horn antennas etched in Si/GaAs for applications to zero-visibility tracking, radio astronomy, plasma diagnostics, and remote sensing.

Eleftheriades, George V.↗

Development of microchannel plates in advanced wind-tunnel instrumentation

Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.

Feller, W. Bruce↗

Coherent systems in the terahertz frequency range: Elements, operation, and examples

The topics are presented in viewgraph form and include the following: terahertz coherent systems applications; a brief overview of selected components; radiometry and spectroscopy--astronomy; radiometry--aircraft all weather landing system; radiometry--atmospheric remote sensing; plasma diagnostics; communications; radar systems; and materials measurement and manufacturing process control.

Goldsmith, Paul F.↗

Monolithic millimeter-wave diode array beam controllers: Theory and experiment

In the current work, multi-function beam control arrays have been fabricated and have successfully demonstrated amplitude control of transmitted beams in the W and D bands (75-170 GHz). While these arrays are designed to provide beam control under DC bias operation, new designs for high-speed electronic and optical control are under development. These arrays will fill a need for high-speed watt-level beam switches in pulsed reflectometer systems under development for magnetic fusion plasma diagnostics. A second experimental accomplishment of the current work is the demonstration in the 100-170 GHz (D band) frequency range of a new technique for the measurement of the transmission phase as well as amplitude. Transmission data can serve as a means to extract ('de-embed') the grid parameters; phase information provides more complete data to assist in this process. Additional functions of the array beam controller yet to be tested include electronically controlled steering and focusing of a reflected beam. These have application in the areas of millimeter-wave electronic scanning radar and reflectometry, respectively.

Sjogren, L. B.↗

An improved ultraviolet spectral line list for the symbiotic star RR Telescopii

We have remeasured wavelengths and intensities of International Ultraviolet Explorer (IUE) spectra of the symbiotic star, RR Tel. The main work is centered on the long 820 minute exposure high-resolution spectrum obtained on 1983 June 18. The list is intended to serve as a source of improved intensities and wavelengths for the ultraviolet spectrum of this star. A complete line list with intensities based on this exposure has not been published previously. The strongest spectral lines are saturated in the 820 minute exposure, and intensities for these lines are mostly obtained from a 20 minute exposure obtained on the same day. A few intensities are obtained from other exposures if neither the 820 nor the 20 minute exposure is satisfactory. There are 111 lines in our list between 1168 and 1980 A. Some of the very weakest lines may not be real. These are indicated by question marks. We also discuss some of the plasma diagnostics available using spectral lines of O v and O iv.

Doschek, G. A.↗