Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Coil optimization for quasi-helically symmetric stellarator configurations

Filament-based coil optimizations are performed for several quasi-helical stellarator configurations, beginning with the one from Landreman & Paul ( Phys. Rev. Lett. , vol. 128, 2022, 035001), demonstrating that precise quasi-helical symmetry can be achieved with realistic coils. Several constraints are placed on the shape and spacing of the coils, such as low curvature and sufficient plasma–coil distance for neutron shielding. The coils resulting from this optimization have a maximum curvature 0.8 times that of the coils of the Helically Symmetric eXperiment (HSX) and a mean squared curvature 0.4 times that of the HSX coils when scaled to the same plasma minor radius. When scaled up to reactor size and magnetic field strength, no fast particle losses were found in the free-boundary configuration when simulating 5000 alpha particles launched at $3.5\,\mathrm {MeV}$ on the flux surface with a normalized toroidal flux of $s=0.5$ . An analysis of the tolerance of the coils to manufacturing errors is performed using a Gaussian process model, and the coils are found to maintain low particle losses for smooth, large-scale errors up to amplitudes of approximately $0.15\,\mathrm {m}$ . Another coil optimization is performed for the Landreman–Paul configuration with the additional constraint that the coils are purely planar. Visual inspection of the Poincaré plot of the resulting magnetic field-lines reveal that the planar modular coils alone do a poor job of reproducing the target equilibrium. Additional non-planar coil optimizations are performed for the quasi-helical configuration with $5\,\%$ volume-averaged plasma beta from Landreman et al. ( Phys. Plasma , vol. 29, issue 8, 2022, 082501), and a similar configuration also optimized to satisfy the Mercier criterion. The finite beta configurations had larger fast-particle losses, with the free-boundary Mercier-optimized configuration performing the worst, losing approximately $5.5\,\%$ of alpha particles launched at $s=0.5$ .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides. Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm 3 ) capable of generating an electron density of greater than 10 13 cm –3 was constructed to produce reactive species (N 2 *, N 2 +, O, OH, and H α ) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. In conclusion, this compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Ideal MHD Limited Electron Temperature in Spherical Tokamaks

It is well documented that the central electron temperature in the national spherical torus experiment (NSTX) remains largely unchanged as the external heating power, and hence the normalized volume averaged plasma pressure β increases [Stutman, Phys. Rev. Lett. 102, 115002 (2009)]. Herein we present a hypothesis that low n, pressure driven ideal magnetohydrodynamic (MHD) instabilities that are nondisruptive, can break magnetic surfaces in the central region and thereby flatten the electron temperature profiles. We demonstrate this mechanism in a 3D resistive MHD simulation of a NSTX discharge. By varying the toroidal magnetic field strength, and/or the heating power, we show that there is a critical value of β, above which the central temperature profile no longer peaks on axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data for Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides . Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm3) capable of generating an electron density of greater than 1013 cm–3 was constructed to produce reactive species (N2*, N2+, O, OH, and Hα) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. This compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

Conversion↗

Low Cost, High Volume, Carbon Fiber Precursor for Plasma Oxidation

Light weighting with carbon fiber is critical to improving the energy efficiency of wind turbines, airplanes, and automobiles, but the high cost of carbon fiber continues to limit market growth and applications. Half of this cost is in the raw materials. For the carbon fiber market to reach the next level of adoption, the cost of both the raw materials and conversion must be reduced. This project considered the combination of low-cost, textile-grade precursors combined with the increased efficiency of plasma oxidation to greatly reduce the cost of carbon fiber. The primary objective of this project was to make industrial-grade carbon fiber (550 ksi tensile strength, 35 Msi tensile modulus) from textile-grade PAN precursors, something that cannot be achieved with conventional oxidation and to date has not been achieved with any technology. To accomplish this, the project team iteratively optimized the process conditions in the plasma oxidation and carbonization stages to maximize the tensile properties of the resultant carbon fibers. This involved implementing experimental designs for both stages, whereby process conditions (e.g. temperature) were varied and correlated to fiber properties. Samples of oxidized PAN fibers (OPFs) were prepared using a small pilot-scale plasma oxidation oven at 4XTechnologies (4XT). The thermal, chemical, and physical properties of OPF samples were analyzed by the University of Tennessee (UTK) and Oak Ridge National Laboratory (ORNL). The OPF samples were then converted to carbon fiber by subsequent low- and high-temperature carbonization using a lab-scale furnace at ORNL. The resultant carbon fibers were tested for tensile strength also at ORNL, and the results were fed back into the experimental design. Of the hundreds of carbon fiber samples produced over the course of the project, the best sample had an average break strength of 479 ksi and modulus of 33 Msi. While the best tensile properties achieved fell short of the final project targets of 550 ksi for break strength and 35 Msi for modulus, the team demonstrated the potential to produce industrial-grade carbon fiber using textile-grade precursors. The best performing fiber samples had tensile properties that are 87% of the goal for tensile strength and 94% of the goal for tensile modulus. With additional optimization work, it is likely that the targets could be achieved, since only a fraction of the process parameter space was explored during this project. 4XT and its affiliate (4M) have already secured funding through private equity, and there is a CRADA (Cooperative Research and Development Agreement) project currently underway with the Carbon Fiber Technology Center (CFTF) at ORNL to continue this research. Additionally, while not an original goal of the project, the carbon fibers for most samples had diameters >8.5μm. This is considerably larger than commercially available carbon fiber products, which can impart unique properties to the composites (e.g. increased compressive strength) and decrease manufacturing costs even further. Moreover, these fibers were oxidized with plasma oxidation using residence times ranging <60mins, which would be considered fast for normal diameter fibers, but it is as much as 5x faster when factoring in the diameter of the fibers.

36 MATERIALS SCIENCE↗

Low-frequency instabilities and plasma turbulence

A theoretical and experimental study is reported of steady-state and time-dependent characteristics of the positive column and the hollow cathode discharge (HCD). The steady state of a non-isothermal, cylindrical positive column in an axial magnetic field is described by three moment equations in the plasma approximation. Volume generation of electron-ion pairs by single-stage ionization, the presence of axial current, and collisions with neutrals are considered. The theory covers the range from the low pressure, collisionless regime to the intermediate pressure, collisional regime. It yields radial profiles of the charged particle velocities, density, potential, electron and ion temperatures, and demonstrates similarity laws for the positive column. The results are compared with two moment theories and with experimental data on He, Ar and Hg found in the literature for a wide range of pressures. A simple generalization of the isothermal theory for an infinitely long cylinder in an axial magnetic field to the case of a finite column with axial current flow is also demonstrated.

Ilic, D. B.↗

Critique of fluid theory of magnetospheric phenomena

It is pointed out that the fluid theory has been successful in magnetospheric problems (such as the shape of the magnetopause) which involve basic considerations such as the conservation of particles, of momentum, and of energy, but that it is inadequate for other problems (such as the energization of auroral particles). Difficulties arise from the fact that it is not always possible to specify 'a volume of plasma' because particles do not remain as neighbors. Misuse of the fluid theory has led to a number of fallacies, such as the idea that the causal order of physical events in cosmic electrodynamics is the reverse of that in the familiar laboratory electrodynamics. This mistaken idea comes from a confusion of a mathematical sequence of calculations with the causal order. A plea is made for a common sense approach to magnetospheric and auroral problems wherein the fluid theory is used whenever it can, but where it is not expected to be adequate for all occasions.

Heikkila, W. J.↗

Self-ducting of large-amplitude whistler waves

Whistler waves are launched from an electric dipole of length L in a large-volume laboratory plasma. With increasing wave amplitude, the radiation pattern narrows and finally forms a duct of diameter approximately equal to L. The ducted waves propagate nearly undamped. The observed nonlinear effects are explained by wave-particle interactions.

Stenzel, R. L.↗

Deconditioning Under Prolonged, Repeated Bed Rest

Cardiovascular deconditioning from prolonged bed rest not counteracted by mild exercise and requires at least 3 weeks for recovery, report contends. Involves more than simple decrease in volume of plasma; neurohumoral mechanisms, loss of mass of skeletal muscles, and general decrease of body's metabolic needs seem to be major contributors.

Sandler, Harold↗

Isotonic And Isokinetic Exercise During Bed Rest

Brief, intense activity prevents deterioration of peak oxygen uptake, a measure of work capacity. Study intended to explore effectiveness of exercise in maintaining fitness during long missions in microgravity so crewmembers able to keep up arduous work of building and expanding Space Station. Showed that intermittent, intense exercise of short duration more effective than similar exercise at lower intensity for longer times measured in previous studies. Intense short-term exercise seems to maintain volumes of plasma and red blood cells at normal levels.

Greenleaf, J. E.↗

Exercise during long term exposure to space: Value of exercise during space exploration

There appear to be two general physiological reasons why exercise will be beneficial to space travelers who will experience a weightless and isolated environment for many months or a few years: (1) to alleviate or prevent tissue atrophy (principally bone and muscle), to maintain cardiovascular function, and to prevent deleterious changes in extracellular and cellular fluid volumes and plasma constituents, especially electrolytes; and (2) to maintain whole organism functional physical and physiological status with special reference to neuromuscular coordination (physical skill) and physical fitness (muscle strength and power, flexibility, and aerobic endurance). The latter reason also relates well to the ability of the crew members to resist both general and local fatigue and thus ensure consistent physical performance. Various forms of exercise, performed regularly, could help alleviate boredom and assist the travelers in coping with stress, anxiety, and depression. The type, frequency, duration and intensity of exercise and ways of ensuring that crew members engage in it are discussed.

Source record↗

Experimental and analytical investigation of a modified ring cusp NSTAR engine

A series of experimental measurements on a modified laboratory NSTAR engine were used to validate a zero dimensional analytical discharge performance model of a ring cusp ion thruster. The model predicts the discharge performance of a ring cusp NSTAR thruster as a function the magnetic field configuration, thruster geometry, and throttle level. Analytical formalisms for electron and ion confinement are used to predict the ionization efficiency for a given thruster design. Explicit determination of discharge loss and volume averaged plasma parameters are also obtained. The model was used to predict the performance of the nominal and modified three and four ring cusp 30-cm ion thruster configurations operating at the full power (2.3 kW) NSTAR throttle level. Experimental measurements of the modified engine configuration discharge loss compare well with the predicted value for propellant utilizations from 80 to 95%. The theory, as validated by experiment, indicates that increasing the magnetic strength of the minimum closed reduces maxwellian electron diffusion and electrostatically confines the ion population and subsequent loss to the anode wall. The theory also indicates that increasing the cusp strength and minimizing the cusp area improves primary electron confinement increasing the probability of an ionization collision prior to loss at the cusp.

cathodes↗

Plasma generator with permanent magnet divertor

A divertor for system supporting plasma for fusion employs permanent magnets providing far weaker magnetic field strength than conventionally used in cryogenic magnetic systems through an ability to place the permanent magnets in close proximity to the plasma containment volume.

Forest, Cary Brett↗

Application of acute maximal exercise to protect orthostatic tolerance after simulated microgravity

We tested the hypothesis that one bout of maximal exercise performed at the conclusion of prolonged simulated microgravity would improve blood pressure stability during an orthostatic challenge. Heart rate (HR), mean arterial blood pressure (MAP), norepinephrine (NE), epinephrine (E), arginine vasopressin (AVP), plasma renin activity (PRA), atrial natriuretic peptide (ANP), cardiac output (Q), forearm vascular resistance (FVR), and changes in leg volume were measured during lower body negative pressure (LBNP) to presyncope in seven subjects immediately prior to reambulation from 16 days of 6 degrees head-down tilt (HDT) under two experimental conditions: 1) after maximal supine cycle ergometry performed 24 h before returning to the upright posture (exercise) and 2) without exercise (control). After HDT, the reduction of LBNP tolerance time from pre-HDT levels was greater (P = 0.041) in the control condition (-2.0 +/- 0.2 min) compared with the exercise condition (-0.4 +/- 0.2 min). At presyncope after HDT, FVR and NE were higher (P < 0.05) after exercise compared with control, whereas MAP, HR, E, AVP, PRA, ANP, and leg volume were similar in both conditions. Plasma volume (PV) and carotid-cardiac baroreflex sensitivity were reduced after control HDT, but were restored by the exercise treatment. Maintenance of orthostatic tolerance by application of acute intense exercise after 16 days of simulated microgravity was associated with greater circulating levels of NE, vasoconstriction, Q, baroreflex sensitivity, and PV.

NASA Discipline Cardiopulmonary↗

The colliding planar shocks platform to study warm dense matter at the National Ignition Facility

We have developed an experimental platform at the National Ignition Facility that employs colliding planar shocks to produce warm dense matter with uniform conditions and enable high-precision equation of state measurements. The platform uses simultaneous x-ray Thomson scattering and x-ray radiography to measure the density, electron temperature, and ionization state in warm dense matter. The experimental platform is designed to create a large volume of uniform plasma (approximately 700×700×150μm 3 ) at pressures approaching 100 Mbar and minimize the distribution of plasma conditions in the x-ray scattering volume, significantly improving the precision of the measurements. Here, in this study, we present the experimental design of the platform and compare hydrodynamic simulations to x-ray radiography data from initial experiments studying hydrocarbons, producing uniform densities within ±25% of the average probed condition. We show that the platform creates a homogeneous plasma that can be characterized using x-ray Thomson scattering. Thus, the new platform enables accurate measurements of plasma conditions necessary to test models for the equation of state and ionization potential depression in the warm dense matter regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics through the 1990s: Plasmas and fluids

The volume contains recommendations for programs in, and government support of, plasma and fluid physics. Four broad areas are covered: the physics of fluids, general plasma physics, fusion, and space and astrophysical plasmas. In the first section, the accomplishments of fluid physics and a detailed review of its sub-fields, such as combustion, non-Newtonian fluids, turbulence, aerodynamics, and geophysical fluid dynamics, are described. The general plasma physics section deals with the wide scope of the theoretical concepts involved in plasma research, and with the machines; intense beam systems, collective and laser-driven accelerators, and the associated diagnostics. The section on the fusion plasma research program examines confinement and heating systems, such as Tokamaks, magnetic mirrors, and inertial-confinement systems, and several others. Finally, theory and experiment in space and astrophysical plasma research is detailed, ranging from the laboratory to the solar system and beyond. A glossary is included.