Search NASA⌕ Search

SEARCH · Search NASA

Results for “Portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

HiPACE++: A portable, 3D quasi-static particle-in-cell code

Modeling plasma accelerators is a computationally challenging task and the quasi-static particle-in-cell algorithm is a method of choice in a wide range of situations. In this work, we present the first performance-portable, quasi-static, three-dimensional particle-in-cell code HiPACE++. By decomposing all the computation of a 3D domain in successive 2D transverse operations and choosing appropriate memory management, HiPACE++ demonstrates orders-of-magnitude speedups on modern scientific GPUs over CPU-only implementations. The 2D transverse operations are performed on a single GPU, avoiding time-consuming communications. The longitudinal parallelization is done through temporal domain decomposition, enabling near-optimal strong scaling from 1 to 512 GPUs. HiPACE++ is a modular, open-source code enabling efficient modeling of plasma accelerators from laptops to state-of-the-art supercomputers.

97 MATHEMATICS AND COMPUTING↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

An automated and portable method for selecting an optimal GPU frequency

Power consumption poses a significant challenge in current and emerging graphics processing unit (GPU) enabled high-performance computing systems. In modern GPUs, dynamic voltage frequency scaling (DVFS) appears to be a reliable control to regulate power consumption and performance. However, the DVFS design space is large - hence, brute-force approaches are infeasible to select the optimal frequency. Furthermore, no single frequency can be universally optimal for applications with varying computational intensities. Thus, the application's complexity and the availability of a wide range of frequency settings are a challenge in selecting the optimal frequency configuration for a given GPU workload. To that end, this paper proposes a systematic approach that consists of three steps. The feature characterization study identifies the fine-grain GPU utilization metrics that influence the power consumption and execution time of a given workload. To understand the performance, power, and energy consumption behaviors of a workload across GPU's DVFS design space, we derived analytical power and performance models using the identified fine-grain features. Here, it is shown that the same set of GPU utilization metrics can estimate both the power consumption and execution time while being agnostic of changes to frequency and input sizes. Applying a power control with the single objective of reducing power may cause performance degradation, leading to more energy consumption. A multi-objective approach is proposed to select the optimal GPU DVFS configuration for a workload that reduces power consumption with negligible degradation in performance. The evaluation was conducted using SPEC ACCEL benchmarks and three real applications - NAMD LAMMPS, and LSTM on NVIDIA GV100, GA100, and AMD MI210 GPUs. On average, real applications showed 29.6% energy savings with a performance loss of 5.2% on GA100 and 22.6% energy savings with a performance loss of 4.7% on GV100. Moreover, the proposed models are portable to real applications, GPU architectures, and vendors, and require metric collection at only the default frequency rather than all supported DVFS configurations. Additionally, we conducted a comparison between our models and the GPU assembly instructions (PTX)-based static models. The results revealed a significant reduction in the average error rates, with a decrease from 19.7% to 3.1% for power models and from 29.4% to 5.2% for performance models.

97 MATHEMATICS AND COMPUTING↗

Improved field-portable system to measure Cs-137 in wildlife

Here, we have developed an improved system to measure Cs-137 in wildlife at the Savannah River Site. This field-portable system consists of a shielded 5 cm by 10 cm by 40 cm NaI detector controlled by an Ametek Ortec Digibase. Measurement of an animal’s radioactivity is made by placing the animal at a predefined location on the detector system for a one minute count-time. The counts, animal type, and animal weight are then used as inputs to an algorithm which calculates the amount of Cs-137 within the whole animal and within the edible meat portion of the animal. The results from these calculations are used to estimate the received dose from eating this animal and is included in the Savannah River Site’s Hunter Dose Tracking System. This system has a detection limit of 0.60 pCi/g (22.20 Bq/kg) with a typical measurement uncertainty of less than 0.32 pCi/g (11.84 Bq/kg).

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Towards performance portability in the Spark astrophysical magnetohydrodynamics solver in the Flash-X simulation framework

Simulations of core-collapse supernovae, and other astrophysical phenomena, are quintessential extreme-scale computing challenges. For core-collapse supernova simulations to be carried out by the ExaStar project under the Exascale Computing Project umbrella, a robust, efficient, and state-of-the-art magnetohydrodynamics solver is a critical requirement. In Flash-X, the primary software instrument for ExaStar, a new magnetohydrodynamics solver has been designed and implemented from the ground up to achieve accuracy and efficiency for simulations of complex astrophysical flows. This new solver, dubbed Spark, uses high-order spatial reconstruction, Runge-Kutta time integration, and an efficient cell-centered approach to satisfying the divergence-free condition for the magnetic fields. Spark was written to be optimized for data locality in cache hierarchy of CPUs. Since data locality optimizations for cache hierarchy are not directly compatible with those of accelerators, we have taken the approach of using program synthesis to avoid massive amounts of code replication that would be necessary if we were to maintain two different versions of the solver. Our program synthesis relies on a simple key-dictionary approach, implemented in python, that enables us to assemble the version of the solver suitable for the target hardware from code fragments identified by specific keys. In this work, we describe the data locality optimizations of the solver for CPUs and accelerators and the program synthesis tools that enable this portability. We also detail the parallel performance of Spark for both CPUs and accelerators.

97 MATHEMATICS AND COMPUTING↗

Programming approaches for scalability, performance, and portability of combustion physics codes

Here, this paper presents the process, strategy, and results associated with porting a typical combustion physics flow solver to current state-of-the-art and future massively-parallel computer architectures. Major focus is placed on the distinct algorithmic structure of these types of codes and how it can be integrated with modern programming paradigms for heterogeneous platforms (i.e., distributed many-core systems with accelerators). An end-to-end case study is presented that exemplifies the process in a generic manner, which then serves as a clear guide with respect to the strategy and best practices leading to a robust and adaptable framework that performs well, is durable over time, is portable, and requires minimal human-effort. This end is accomplished beginning with the use of a mature, validated, structured, multiblock code framework optimized for application of both Large Eddy Simulation (LES) and Direct Numerical Simulation (DNS). This code has been ported to a variety of platforms over the past decade, including most recently the Oak Ridge Leadership Computing Facility’s “Summit” Platform. The experience gained on these multiple platforms provides general insights and thus the results presented are not specific to any one code or platform other than the overarching trend toward distributed many-core systems with accelerators in order to move toward exascale performance. The resultant performance and scalability of the ported code is demonstrated on a real-world application; a state-of-the-art rotating detonation rocket engine simulation that matches the complex geometry and boundary conditions imposed as part of a companion experimental campaign.

97 MATHEMATICS AND COMPUTING↗

WEEE and portable batteries in residual household waste: Quantification and characterisation of misplaced waste

Highlights: • We analyse 26.1 Mg of residual waste from 3129 Danish households. • We quantify and characterise misplaced WEEE and portable batteries. • We compare misplaced WEEE and batteries to collection through dedicated schemes. • Characterisation showed that primarily small WEEE and light sources are misplaced. • Significant amounts of misplaced batteries were discarded as built-in WEEE. - Abstract: A total of 26.1 Mg of residual waste from 3129 households in 12 Danish municipalities was analysed and revealed that 89.6 kg of Waste Electrical and Electronic Equipment (WEEE), 11 kg of batteries, 2.2 kg of toners and 16 kg of cables had been wrongfully discarded. This corresponds to a Danish household discarding 29 g of WEEE (7 items per year), 4 g of batteries (9 batteries per year), 1 g of toners and 7 g of unidentifiable cables on average per week, constituting 0.34% (w/w), 0.04% (w/w), 0.01% (w/w) and 0.09% (w/w), respectively, of residual waste. The study also found that misplaced WEEE and batteries in the residual waste constituted 16% and 39%, respectively, of what is being collected properly through the dedicated special waste collection schemes. This shows that a large amount of batteries are being discarded with the residual waste, whereas WEEE seems to be collected relatively successfully through the dedicated special waste collection schemes. Characterisation of the misplaced batteries showed that 20% (w/w) of the discarded batteries were discarded as part of WEEE (built-in). Primarily alkaline batteries, carbon zinc batteries and alkaline button cell batteries were found to be discarded with the residual household waste. Characterisation of WEEE showed that primarily small WEEE (WEEE directive categories 2, 5a, 6, 7 and 9) and light sources (WEEE directive category 5b) were misplaced. Electric tooth brushes, watches, clocks, headphones, flashlights, bicycle lights, and cables were items most frequently found. It is recommended that these findings are taken into account when designing new or improving existing special waste collection schemes. Improving the collection of WEEE is also recommended as one way to also improve the collection of batteries due to the large fraction of batteries found as built-in. The findings in this study were comparable to other western European studies, suggesting that the recommendations made in this study could apply to other western European countries as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid

Onsite rapid detection of herbicide and herbicide residuals in environmental and biological specimens is important for agriculture, environment, food safety, and health care. Traditional method for herbicide detection requires expensive laboratory equipment and a long turn-round time. In this work, we developed a single-stripe microliter plate smartphone colorimetric device for rapid and low-cost in-field test. This portable smartphone platform is capable of screening 8 samples in a microplate single-stripe. The device combined the advantages of small size (50×100×160 mm3) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and Rhodamine B, for green and red channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for an herbicide, 2,4-Dichlorophenoxyacetic acid detection in the range of 1 ppb to 80 ppb. Spiked samples of tap water, rat serum, plasma and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all spiked samples using the microplate reader and from 93.7% to 106.9% using the smartphone device. This work validated that the smartphone optical sensing platform is comparable to the commercial microplate reader, it is eligible for onsite rapid and low-cost detection of herbicide for environmental evaluation and biological monitoring.

Wang, Yijia↗

PDFDataExtractor: A Tool for Reading Scientific Text and Interpreting Metadata from the Typeset Literature in the Portable Document Format

The layout of portable document format (PDF) files is constant to any screen, and the metadata therein are latent, compared to mark-up languages such as HTML and XML. No semantic tags are usually provided, and a PDF file is not designed to be edited or its data interpreted by software. However, data held in PDF files need to be extracted in order to comply with opensource data requirements that are now government-regulated. In the chemical domain, related chemical and property data also need to be found, and their correlations need to be exploited to enable data science in areas such as data-driven materials discovery. Such relationships may be realized using text-mining software such as the “chemistry-aware” natural-language-processing tool, ChemDataExtractor; however, this tool has limited data-extraction capabilities from PDF files. This study presents the PDFDataExtractor tool, which can act as a plug-in to ChemDataExtractor. It outperforms other PDF-extraction tools for the chemical literature by coupling its functionalities to the chemical-named entityrecognition capabilities of ChemDataExtractor. The intrinsic PDF-reading abilities of ChemDataExtractor are much improved. The system features a template-based architecture. This enables semantic information to be extracted from the PDF files of scientific articles in order to reconstruct the logical structure of articles. While other existing PDF-extracting tools focus on quantity mining, this template-based system is more focused on quality mining on different layouts. PDFDataExtractor outputs information in JSON and plain text, including the metadata of a PDF file, such as paper title, authors, affiliation, email, abstract, keywords, journal, year, document object identifier (DOI), reference, and issue number. With a self-created evaluation article set, PDFDataExtractor achieved promising precision for all key assessed metadata areas of the document text.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Porting ATLAS Fast Calorimeter Simulation to GPUs with Performance Portable Programming Models

FastCaloSim is a parameterized simulation of the particle energy response and of the energy distribution in the ATLAS calorimeter. It is a relatively small and self-contained package with massive inherent parallelism and captures the essence of GPU offloading via important operations like data transfer, memory initialization, floating point operations, and reduction. It was identified by the High Energy Physics Center for Computational Excellence project as a good testbed for evaluating the performance and ease of portability of programming models. In this paper, we will discuss the results of our evaluation of the porting process to Kokkos, SYCL, Alpaka, OpenMP and std::par (nvc++), and compare performance on NVIDIA, AMD and Intel GPUs, as well as multicore CPUs.

97 MATHEMATICS AND COMPUTING↗

Packaging HEP Heterogeneous Mini-apps for Portable Benchmarking and Facility Evaluation on Modern HPCs

High Energy Physics (HEP) experiments are making increasing use of GPUs and GPU dominated High Performance Computer facilities. Both the software and hardware of these systems are rapidly evolving, creating challenges for experiments to make informed decisions as to where they wish to devote resources. In its first phase, the High Energy Physics Center for Computational Excellence (HEP-CCE) produced portable versions of a number of heterogeneous HEP mini-apps, such as p2r, FastCaloSim, Patatrack and the WireCell Toolkit, that exercise a broad range of GPU characteristics, enabling cross platform and facility benchmarking and evaluation. However, these miniapps still require a significant amount of manual intervention to deploy on a new facility. We present our work in developing turn-key deployments of these mini-apps, where by means of containerization and automated configuration and build techniques such as Spack, we are able to quickly test new hardware, software, environments and entire facilities with minimal user intervention, and then track performance metrics over time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hydra: An AI-Based Framework for Interpretable and Portable Data Quality Monitoring

Hydra is an advanced framework designed for training and managing AI models for near real time data quality monitoring at Jefferson Lab. Deployed in all four experimental halls, Hydra has analyzed over 2 million images and has extended its capabilities to offline monitoring and validation. Hydra utilizes computer vision to continually analyze sets of images of monitoring plots generated 24/7 during experiments. Generally, these sets of images are produced at a rate and quantity that is exceedingly difficult for shift crews to effectively monitor. Significant effort has been devoted to enhancing Hydra’s user interface, to ensure that it provides clear, actionable insights for shift workers and other users. Gradient Weighted Class Activation Maps (GradCAM) provide added interpretability, allowing users to visualize important regions of the image for classification. Hydra has been containerized to enable the creation of portable demos and seamless integration with container-based technologies such as Kubernetes and Docker. With the user interface enhancements and containerization, Hydra can be rapidly deployed for new use cases and experiments. This talk will describe the Hydra framework, its user interface and experience, and the challenges inherent in its design and deployment.

Britton, Thomas [Thomas Jefferson National Acceler↗

Medipix2/USB Portable Radiation Camera

Advances in the field of semiconductor technologies in the last years make possible to develop new types of ionizing radiation detectors. The Medipix2 readout ASIC is an example of such a device. It is the hybrid single photon counting imaging chip (sensor and readout chips are fabricated separately). With an appropriate sensor chip on the top, it can count single X-ray photons, without any noise or dark current, at high fluxes (several Gigaphotons per cm{sup 2} per second). It also offers excellent radiation hardness and good position resolution (256x256 pixels, each pixel has a 55x55 {mu}m{sup 2} area). To make the Medipix2 imaging chip more portable for specific applications a microprocessor controlled read-out system based on the USB (Universal Serial Bus) interface has been developed. It integrates all necessary detector support into one compact device (75x46 mm{sup 2}). All power supplies including sensor bias (up to 100 V) are internally derived from the voltage provided by the USB connection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanofocus of tenth of joules and a portable plasma focus of few joules for field applications

A repetitive pinch plasma focus that works with stored energy less than 1 J per shot has be developed at the Chilean Nuclear Energy Commission. The main features of this device, repetitive Nanofocus, are 5 nF of capacity, 5 nH of inductance, 5-10 kV charging voltage, 60-250 mJ stored energy, 5-10 kA current peak, per shot. The device has been operated at 20 Hz in hydrogen and deuterium. X-ray radiographs of materials of different thickness were obtained. Neutrons were detected using a system based upon {sup 3}He proportional counter in chare integrated mode. However, the reproducibility of this miniaturized device is low and several technological subjects have to be previously solved in order to produce neutrons for periods greater than minutes. Further studies in the Nanofocus are being carried out. In addition, a device with a stored energy of a few joules is being explored. A preliminary compact, low weight (3 kg), portable PF device (25 cmx5 cmx5 cm) for field applications has been designed. This device was designed to operate with few kilovolts (10 kV or less) with a stored energy of 2 J and a repetition rate of 10 Hz without cooling. A neutron flux of the order of 10{sup 4}-10{sup 5} n/s is expected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Portable UV-visible spectrometer for measuring absorbance and dichroism of Langmuir monolayers at air-water interfaces.

An UV-visible spectrometer for measuring absorbance and dichroism of Langmuir monolayers under in situ conditions is described. The spectrometer utilizes a stand-alone multipass sensor, which is placed in a Langmuir trough and coupled with light source and spectrometer head via fiber optics. Implementation of the multipass scheme in the absorbance sensor makes it possible to obtain reliable quantitative spectroscopic data of the Langmuir monolayers with absorbance as low as 1 mOD. Such high sensitivity makes the developed sensor very useful for UV-visible spectral studies of a wide variety of chromophores. The new technique was applied to several model systems: fatty acid monolayers containing amphiphilic dyes DiI or BODIPY and also a monolayer of a synthetic amphiphilic porphyrin-binding peptide BBC16. Implementation of UV-visible absorbance spectroscopy measurements in situ together with x-ray scattering technique was used to confirm the bound state of the chromophore, and determine the exact position of the latter in the peptide matrix. Fiber optics design of the spectrometer provides portability and compatibility with other experimental techniques making it possible to study samples with a geometry unsuitable for conventional spectroscopic measurements and located in experimental environments with spatial limitations, such as synchrotron x-ray scattering stations.

36 MATERIALS SCIENCE↗

A PORTABLE MICROWAVE INTERFERENCE SCANNING SYSTEM FOR NONDESTRUCTIVE TESTING OF MULTI-LAYERED DIELECTRIC MATERIALS

A portable, microwave interference scanning system, that can be used in situ, with one-sided, non-contact access, has been developed. It has demonstrated capability of damage detection on composite ceramic armor. Specimens used for validation included specially fabricated surrogates, and non-ballistic impact-damaged specimens. Microwave data results were corroborated with high resolution direct-digital x-ray imaging. Microwave interference scanning detects cracks, laminar features and material properties variations. This paper will present details of the system and discuss results obtained.

36 MATERIALS SCIENCE↗

Development of a Portable 950 keV X-band Linac for NDT

We are developing a portable 950 keV X-band (9.4 GHz) linac X-ray source for on-site nondestructive testing of erosion of metal pipes at a petrochemical complex. To develop it, we adopted a compact X-band 9.4 GHz magnetron of 250 kW for RF generation device. The whole device, including power supply and cooling devices, were also downsized. The dose rate of X-ray converted in a tungsten target is designed to be 0.2 Gy/min at 1-m distance. We designed an accelerating tube that uses the {pi} mode for the lower energy part and the {pi}/2 mode cavity for the higher energy. We manufactured the accelerating tube and carried out beam acceleration tests, confirming that the electron beam was accelerated up to 950 keV.

43 PARTICLE ACCELERATORS↗