Evaluating zinc isotope fractionation under sulfate reducing conditions using a flow-through cell and in situ XAS analysis
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Online nuclear measurements inside experimental channels of MTRs are needed for experimental works (to design set-ups) and for numerical works (input data) in order to better understanding complex phenomena occurring during the accelerated ageing of materials and the irradiation of nuclear fuel. In this paper we focus only on one kind of measurements: nuclear heating performed by means of a radiometric calorimeter. The aims of numerical and experimental works are firstly to optimize the sensor response for new energy deposit ranges and then to miniaturize this sensor for JHR irradiation conditions A first calorimeter, developed previously by the CEA, is studied. It corresponds to a graphite differential calorimeter divided into two twin cells (a reference cell, and a sample one). It is used with a non adiabatic mode or heat flow mode. Experimental calibration of the sample cell is presented. In that case, energy deposit is simulated by Joule effect and the sample cell is inserted into a bath at a regulated temperature and controlled flow. The response of the sensor is shown versus electrical power imposed for two flow regimes (intensive or moderated forced convection). These experimental results are compared to numerical works and improvements are discussed. (authors)
Automatic Generation Control (AGC) is a key control system in the power grid. It is used to calculate the Area Control Error (ACE) based on frequency and tie-line power flow between balancing areas, and then adjust power generation to maintain the power system frequency in an acceptable range. However, attackers might inject malicious frequency or tie-line power flow measurements to mislead AGC to do false generation correction which will harm the power grid operation. Such attacks are hard to be detected since they do not violate physical power system models. In this work, we propose algorithms based on Neural Network and Fourier Transform to detect data forgery attacks in AGC. Different from the few previous work that rely on accurate load prediction to detect data forgery, our solution only uses the ACE data already available in existing AGC systems. In particular, our solution learns the normal patterns of ACE time series and detects abnormal patterns caused by artificial attacks. Evaluations on the real ACE dataset show that our methods have high detection accuracy.
This paper introduces Moving Target Defense (MTD) in distribution system against False Data Injection (FDI) attacks on the supervisory control and data acquisition (SCADA) system. Based on the AC power flow model, a hidden MTD (HMTD) strategy is constructed in combination with network reconfiguration by minimizing the system loss and line power flow differences before and after the HMTD. The proposed HMTD-based network reconfiguration is formulated as a mixed-integer nonlinear programming (MINLP) problem. A refined Genetic Algorithm (GA) is proposed to solve it. Numerical test is conducted in a modified IEEE-66 bus system. The simulation results show that the proposed model reduces the power loss introduced by the HMTD as well as yields a stealthy MTD to the attackers. The impact of HMTD on the system performance is also compared with that of the existing MTD strategies.
This report reviews the potential for distribution-grid phase-angle data that will be available from new micro-synchrophasors (µPMUs) to be utilized in existing distribution-grid planning and operations analysis. This data could augment the current diagnostic capabilities of grid analysis software, used in both planning and operations for applications such as fault location, and provide data for more accurate modeling of the distribution system. µPMUs are new distribution-grid sensors that will advance measurement and diagnostic capabilities and provide improved visibility of the distribution grid, enabling analysis of the grid’s increasingly complex loads that include features such as large volumes of distributed generation. Large volumes of DG leads to concerns on continued reliable operation of the grid, due to changing power flow characteristics and active generation, with its own protection and control capabilities. Using µPMU data on change in voltage phase angle between two points in conjunction with new and existing distribution-grid planning and operational tools is expected to enable model validation, state estimation, fault location, and renewable resource/load characterization. Our findings include: data measurement is outstripping the processing capabilities of planning and operational tools; not every tool can visualize a voltage phase-angle measurement to the degree of accuracy measured by advanced sensors, and the degree of accuracy in measurement required for the distribution grid is not defined; solving methods cannot handle the high volumes of data generated by modern sensors, so new models and solving methods (such as graph trace analysis) are needed; standardization of sensor-data communications platforms in planning and applications tools would allow integration of different vendors’ sensors and advanced measurement devices. In addition, data from advanced sources such as µPMUs could be used to validate models to improve/ensure accuracy, providing information on normally estimated values such as underground conductor impedance, and characterization of complex loads. Although the input of high-fidelity data to existing tools will be challenging, µPMU data on phase angle (as well as other data from advanced sensors) will be useful for basic operational decisions that are based on a trend of changing data.
This work is developing particle flow control and measurement methods for next-generation concentrating solar power systems employing particle-based technologies. Particle receivers are being pursued to provide substantial performance improvements through higher temperatures (>700 °C) for more efficient and cost-effective CSP systems with direct storage for electricity generation, process heating, thermochemistry, and solar fuels production. This specific work will develop technologies that enable more efficient particle receivers and scalable methods to accommodate variable irradiances during commercial on-sun operation. The development of next-generation particle-receiver systems and methods with potentially high consequences for improved performance and cost savings for CSP applications is an appropriate role for the government.
Distributed photovoltaic systems (DPV) can cause adverse grid impacts, including voltage or thermal violations. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current methods for determining hosting capacity tend to be conservative by either only considering infrequent worst-case snapshots in time and/or only capturing coarse time and spatial resolution. Additionally, current hosting capacity methods do not accurately capture the time-dependence making them unable to capture the behavior of voltage regulating equipment and of some advanced controls mitigations. This can trigger delays from unnecessary engineering analysis or deter solar installations in areas that are actually suitable. We propose a quasi-static-timeseries (QSTS) based PV hosting capacity methodology to address these issues. With this approach, we conduct power flow analysis over the course of a full year, to capture time-varying parameters and control device actions explicitly. We show that this approach can more fully capture grid impacts of DPV than traditional methods.
A multi-institutional plasma combustion team was awarded a research project from the DOE/NNSA GIPP (Global Initiative for Prolifereation Prevention) office. The Institute of High Current Electronics (Tomsk, Russia); Leonardo Technologies, Inc. (an American-based industrial partner), in conjunction with the Los Alamos National Laboratory are participating in the project to develop novel plasma assisted combustion technologies. The purpose of this project is to develop prototypes of marketable systems for more stable and cleaner combustion of syngas/biofuels and to demonstrate that this technology can be used for a variety of combustion applications - with a major focus on contemporary gas turbines. In this paper, an overview of the project, along with descriptions of the plasma-based combustors and associated power supplies will be presented. Worldwide, it is recognized that a variety of combustion fuels will be required to meet the needs for supplying gas-turbine engines (electricity generation, propulsion), internal combustion engines (propulsion, transportation), and burners (heat and electricity generation) in the 21st Century. Biofuels and biofuel blends have already been applied to these needs, but experience difficulties in modifications to combustion processes and combustor design and the need for flame stabilization techniques to address current and future environmental and energy-efficiency challenges. In addition, municipal solid waste (MSW) has shown promise as a feedstock for heat and/or electricity-generating plants. However, current combustion techniques that use such fuels have problems with achieving environmentally-acceptable air/exhaust emissions and can also benefit from increased combustion efficiency. This project involves a novel technology (a form of plasma-assisted combustion) that can address the above issues. Plasma-assisted combustion (PAC) is a growing field that is receiving worldwide attention at present. The project is focused on research necessary to develop a novel, high-efficiency, low-emissions (near-zero, or as low as reasonably achievable), advanced combustion technology for electricity and heat production from biofuels and fuels derived from MSW. For any type of combustion technology, including the advanced technology of this project, two problems of special interest must be addressed: developing and optimizing the combustion chambers and the systems for igniting and sustaining the fuel-burning process. For MSW in particular, there are new challenges over gaseous or liquid fuels because solid fuels must be ground into fine particulates ({approx} 10 {micro}m diameter), fed into the advanced combustor, and combusted under plasma-assisted conditions that are quite different than gaseous or liquid fuels. The principal idea of the combustion chamber design is to use so-called reverse vortex gas flow, which allows efficient cooling of the chamber wall and flame stabilization in the central area of the combustor (Tornado chamber). Considerable progress has been made in design ing an advanced, reverse vortex flow combustion chamber for biofuels, although it was not tested on biofuels and a system that could be fully commercialized has never been completed.
Advancement of U.S. scientific, security, and economic interests through a robust space exploration program requires high performance propulsion systems to support a variety of robotic and crewed missions beyond low Earth orbit. In NASA’s recent Mars Design Reference Architecture (DRA) 5.0 study (NASA-SP-2009-566, July 2009), nuclear thermal propulsion (NTP) was again selected over chemical propulsion as the preferred in-space transportation system option because of its high thrust and high specific impulse (-900 s) capability, increased tolerance to payload mass growth and architecture changes, and lower total initial mass in low Earth orbit. An extensive nuclear thermal rocket technology development effort was conducted from 1955-1973 under the Rover/NERVA Program. The Small Nuclear Rocket Engine (SNRE) was the last engine design studied by the Los Alamos National Laboratory during the program. At the time, this engine was a state-of-the-art design incorporating lessons learned from the very successful technology development program. Past activities at the NASA Glenn Research Center have included development of highly detailed MCNP Monte Carlo transport models of the SNRE and other small engine designs. Preliminary core configurations typically employ fuel elements with fixed fuel composition and fissile material enrichment. Uniform fuel loadings result in undesirable radial power and temperature profiles in the engines. Engine performance can be improved by some combination of propellant flow control at the fuel element level and by varying the fuel composition. Enrichment zoning at the fuel element level with lower enrichments in the higher power elements at the core center and on the core periphery is particularly effective. Power flattening by enrichment zoning typically results in more uniform propellant exit temperatures and improved engine performance. For the SNRE, element enrichment zoning provided very flat radial power profiles with 551 of the 564 fuel elements within 1% of the average element power. Results for this and alternate enrichment zoning options for the SNRE are compared.
For the advanced tokamak operation in Korea Superconducting Tokamak Advanced Research (KSTAR), up to 6 MW of electron cyclotron heating (ECH) is planned. The ECH launcher should be able to operate in steady state and serve as a central/off-axis heating and current drive, q-profile control, and control of the neoclassical tearing mode (NTM) and sawtooth. The water cooled launchers have been upgraded to include continuous operation with precise, high-speed real-time control of the beams by integration with the plasma control system (PCS) for supporting the experiments, in particular for suppressing NTM. Here, the launcher was successfully operated for 78 s with about 650 kW EC power, where the temperature of the coolant, with a flow rate of 9.6 lpm, is saturated and approximately 2 °C. The launcher control system had a maximum control cycle of 5 kHz and a motor latency of about 10 ms, and the poloidal scanning speed of the beam was 20 °/s. Additionally, for the higher localization of power deposition, the curvature and size of the mirrors in the launcher were optimized. This paper presents the ECH launcher design and its control system with the operation results.
This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.
This paper presents a solution for reducing energy loss in the hydraulic control system of agricultural tractors and their implements. The solution is referred to as a multi-pressure rail (MPR) and provides power to the hydraulic functions following a pressure control logic, as opposed to the traditional flow control logic typical of hydraulic systems used in off-road vehicles. The proposed hydraulic control system allows for elimination of redundant flow control valves in the state-of-the-art system, which cause excessive throttling losses leading to poor overall energy efficiency. Related work on MPR technology targets construction vehicles, where the MPR solution can allow energy recovery during overrunning loads and better engine management. This paper alternatively addresses the case of agricultural applications where functions mostly operate under resistive load conditions with slow dynamics, which offers an opportunity to target throttle losses. For this purpose, the paper introduces a variable pressure control strategy to handle the instantaneous pressure at each rail. To develop both the controller and the hydraulic system architecture, a stationary test rig is conceived and used to validate a numerical simulation model of the MPR system and its control strategy. Particular focus is given to the dynamic behavior of the system during the switches of a function between different pressure rails, which needs to ensure reduced oscillations of the flow provided to each hydraulic function. Once validated, the simulation model is used to predict the energy savings of the MPR solution in an actual application: a 435 hp hydraulic tractor powering a 16-row planter, for which operating features during typical drive cycles were available to the authors. The results show up to 59% total power reduction at the pump shaft, corresponding to 89.8% system efficiency gain.
A nuclear power system includes a reactor vessel that includes a reactor core mounted therein. The reactor core includes nuclear fuel assemblies configured to generate a nuclear fission reaction. The reaction vessel does not include any control rod assemblies therein. The nuclear power system further includes a riser positioned above the reactor core, a primary coolant flow path, a primary coolant that circulates through the primary coolant flow path to receive heat from the nuclear fission reaction and release the received heat to generate electric power in a power generation, and a control system communicably coupled to the power generation system and configured to control a power output of the nuclear fission reaction independent of any control rod assemblies.
The invention relates to a nuclear plant in which the power of a nuclear reactor is controlled via demand of a connected electric grid. A naturally circulating nuclear reactor coolant loop is linked to a water/steam loop by means of a steam generator. The water/steam loop consists of an electric power generating unit and a water recirculating and steam control system. The generator is coupled to an external power grid. As power requirements of the grid change, a controller linked to the generator and a three way valve divides steam flow between the expansion turbine and a feedwater heater to boost or retard the power output. Altering the steam flow changes the pressure and temperature in the water/steam system and thus the coolant flow rate. The change in coolant flow allows the reactor core to regulate its reactivity to reach a state of equilibrium to the demand for electric power.
Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.
With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.
Ensuring long-term voltage stability is critical for reliable operations of power grids. High share of distributed energy resources (DERs) can create complicated system operation modes that may invalidate the traditional long-term voltage stability analysis based on typical operation modes. To address this challenge, this paper investigates how to compute the shortest path to the voltage stability boundary in the DER aggregated load space with large dispersion. Instead of working in the Euclidean space, we establish the analysis and computations on the algebraic power flow manifold to better capture the curvature change of the shortest path along the direction of losing stability. A modified optimal control framework is presented for obtaining the ground-truth of the smooth shortest path on the manifold. To efficiently and accurately solve for the shortest path, we further leverage the geometric features of the power flow manifold and propose a tri-sectional approximation model that is scalable for large-scale systems. Several numerical examples, up to the 1354-bus system, with different DER penetration levels and high dimensional renewable power injection variations are evaluated. The simulation results demonstrate that the tri-sectional approximation achieves high accuracy and efficiency to approximate the shortest path to the voltage stability boundary.
The growth in distributed energy resources has the potential to reduce system stresses caused by transmission grid congestion by supplying power and voltage regulation closer to load centers. However, the additional voltage regulation provided by these resources can mask the onset of voltage collapse. Local voltage support flattens the slope in the upper region of the power-voltage nose curve. Coordinating voltage-regulation behavior with the droop-control scheme in distributed resources improves the observation of voltage collapse margins. Incorporating distributed resource models in the continuation power flow analysis, allows the exploration of the power transfer gains by the application of distributed resources. The analysis provides insight to the impact of droop control on the behavior of the power-voltage curve and voltage collapse. The analysis is applied to a fixed speed induction generator wind farm with separate reactive compensation and the interconnection to the local power system. Results reveal that coordinating the droop control strategy allows the distributed resource to significantly increase the voltage collapse margin without hiding the threat of voltage stability problems.