Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Exploring transport mechanisms in atomic precision advanced manufacturing enabled pn junctions

We investigate the different transport mechanisms that can occur in pn junction devices made using atomic precision advanced manufacturing at temperatures ranging from cryogenic to room temperature. We first elucidate the potential cause of the anomalous behavior observed in the forward-bias response of these devices in recent cryogenic temperature measurements, which deviates from the theoretical response of a silicon Esaki diode. These anomalous behaviors include current suppression at low voltages in the forward-bias response and a much lower valley voltage at cryogenic temperatures than theoretically expected for a silicon diode. To investigate the potential causes of these anomalies, we studied the effects of a few possible transport mechanisms, including band-to-band tunneling, bandgap narrowing, potential impact of non-Ohmic contacts, band quantization, impact of leakage, and inelastic trap-assisted tunneling, through semi-classical simulations. We find that a combination of two sets of band-to-band tunneling (BTBT) parameters can qualitatively approximate the shape of the tunneling current at low bias. This can arise from band quantization and realignment due to the strong potential confinement in δ-layers. We also find that the lower-than-theoretically-expected valley voltage can be attributed to modifications in the electronic band structure within the δ-layer regions, leading to a significant bandgap narrowing induced by the high density of dopants. Finally, we extend our analyses to room temperature operation and predict that trap-assisted tunneling (TAT) facilitated by phonon interactions may become significant, leading to a complex superposition of BTBT and TAT transport mechanisms in the electrical measurements.

band gap↗

Precision ultranarrow-linewidth resonance excitation (PURE) preparation of a molecular beam of nitric oxide molecules for inelastic scattering with argon

We recently reported a novel technique that utilizes narrow-linewidth lasers to selectively excite molecules into a pure quantum state with a well-resolved, tunable distribution of velocities [O. A. Krohn and D. W. Chandler, J. Phys. Chem. Lett. 15(50), 12455–12463 (2024)]. We refer to the preparation of molecules by this technique as precision ultranarrow-linewidth resonant excitation (PURE) preparation. Here, in this study, we pair this PURE preparation methodology with active frequency stabilization of the quantum cascade laser that drives the excitation. In doing so, highly velocity-resolved packets of molecules are possible, with the limitations of this velocity resolution set by the stability of the laser locking and the spectral linewidth of the transition. We show that side-of-fringe locking to a Doppler-broadened absorption spectrum of our target molecule is sufficiently stable for PURE preparation of molecules for long timescales (several hours) with highly resolved velocity spreads (σ < 3 m/s). To demonstrate the scientific utility of this new capability, we present differential cross sections from scattering between a neat molecular beam of argon and a velocity-selected beam of nitric oxide (NO) in a pure quantum state. We observe well-resolved quantum diffraction oscillations in the forward-scattered collisions as well as general trends consistent with prior characterized collisions of NO + Ar.

Krohn, Olivia A. [Sandia National Laboratories (SN↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise stellarator quasi-symmetry can be achieved with electromagnetic coils

Magnetic fields with quasi-symmetry are known to provide good confinement of charged particles and plasmas, but the extent to which quasi-symmetry can be achieved in practice has remained an open question. Recent work [M. Landreman and E. Paul, Phys. Rev. Lett. 128, 035001, 2022] reports the discovery of toroidal magnetic fields that are quasi-symmetric to orders-of-magnitude higher precision than previously known fields. We show that these fields can be accurately produced using electromagnetic coils of only moderate engineering complexity, that is, coils that have low curvature and that are sufficiently separated from each other. Our results demonstrate that these new quasi-symmetric fields are relevant for applications requiring the confinement of energetic charged particles for long time scales, such as nuclear fusion. The coils’ length plays an important role for how well the quasi-symmetric fields can be approximated. For the longest coil set considered and a mean field strength of 1 T, the departure from quasi-symmetry is of the order of Earth’s magnetic field. Additionally, we find that magnetic surfaces extend far outside the plasma boundary used by Landreman and Paul, providing confinement far from the core. Simulations confirm that the magnetic fields generated by the new coils confine particles with high kinetic energy substantially longer than previously known coil configurations. In particular, when scaled to a reactor, the best found configuration loses only 0.04% of energetic particles born at midradius when following guiding center trajectories for 200 ms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Improved Boosting to Amplify Signal with Isobaric Labeling (iBASIL) Strategy for Precise Quantitative Single-cell Proteomics

Mass spectrometry (MS)-based proteomics has great potential for overcoming the limitations of antibody-based immunoassays for antibody-independent, comprehensive, and quantitative proteomic analysis of single cells. Indeed, recent advances in nanoscale sample preparation have enabled effective processing of single cells. In particular, the concept of using boosting/carrier channels in isobaric labeling to increase the sensitivity in MS detection has also been increasingly used for quantitative proteomic analysis of small-sized samples including single cells. However, the full potential of such boosting/carrier approaches has not been significantly explored, nor has the resulting quantitation quality been carefully evaluated. Herein, we have further evaluated and optimized our recent boosting to amplify signal with isobaric labeling (BASIL) approach, originally developed for quantifying phosphorylation in small number of cells, for highly effective analysis of proteins in single cells. This improved BASIL (iBASIL) approach enables reliable quantitative single-cell proteomics analysis with greater proteome coverage by carefully controlling the boosting-to-sample ratio (e.g. in general <100×) and optimizing MS automatic gain control (AGC) and ion injection time settings in MS/MS analysis (e.g. 5E5 and 300 ms, respectively, which is significantly higher than that used in typical bulk analysis). By coupling with a nanodroplet-based single cell preparation (nanoPOTS) platform, iBASIL enabled identification of ~2500 proteins and precise quantification of ~1500 proteins in the analysis of 104 FACS-isolated single cells, with the resulting protein profiles robustly clustering the cells from three different acute myeloid leukemia cell lines. This study highlights the importance of carefully evaluating and optimizing the boosting ratios and MS data acquisition conditions for achieving robust, comprehensive proteomic analysis of single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Precision Polishing of Ablator Capsules via in situ Process Monitoring and Machine Learning–Based Optimization

In inertial confinement fusion (ICF) experiments seeking output gains of unity and beyond, the quality of the ablator capsule is paramount for minimizing the hydrodynamic mix that quenches the central hot spot. Defects in the form of foreign particles or missing mass on the surface and within the wall of the capsule are primary offenders. High-density carbon capsules made for ICF experiments at the National Ignition Facility are precision polished to achieve surface smoothness on the order of a few nanometers as well as to minimize isolated defects in the form of pits. Given the critical role of this process, we are developing smart manufacturing techniques with the goal of elevating the efficiency of this process. Our approach is to use MEMS (micro-electromechanical systems)–based sensors to capture the fine vibration signals generated during the polishing process and combine them with synchronized visual feedback as needed. Beyond using these sensors for process monitoring, we use specific deep learning methods to analyze the data and extract correlations with both the process parameters and the final performance of the polishing run. Here, in this work, we describe the multiple fronts we have explored in this regard and the results we have gotten so far. This approach promises to have the potential to ultimately provide real-time feedback that can be used to ensure the progress of the run as well as a means for faster optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision Tests of the Nonlinear Mode Coupling of Anisotropic Flow via High-Energy Collisions of Isobars

Valuable information on dynamics of expanding fluids can be inferred from the response of such systems to perturbations in their initial geometry. We apply this technique in high-energy 96 Ru+ 96 Ru and 96 Zr+ 96 Zr collisions to scrutinize the expansion dynamics of the quark-gluon plasma, where the initial geometry perturbations are sourced by the differences in deformations and radial profiles between 96 Ru and 96 Zr, and the collective response is captured by the change in anisotropic flow V n between the two collision systems. Using a transport model, we analyze how the nonlinear coupling between lower-order flow harmonics V 2 and V 3 to the higher-order flow harmonics V 4 and V 5 , expected to scale as V 4 NL = χ 4 V 2 2 and V 5NL = χ 5 V 2 V 3 , gets modified as one moves from 96 Ru+ 96 Ru to 96 Zr+ 96 Zr systems. We find that these scaling relations are valid to high precision: variations of order 20% in V 4NL and V 5NL due to differences in quadrupole deformation, octupole deformation, and nuclear skin modify χ 4 and χ 5 by about 1–2%. Percent-level deviations are however larger than the expected experimental uncertainties and could be measured. Therefore, collisions of isobars with different nuclear structures are a unique tool to isolate subtle nonlinear effects in the expansion of the quark-gluon plasma that would be otherwise impossible to access in a single collision system.

Physics↗

Towards precise and accurate calculations of neutrinoless double-beta decay

We present the results of a National Science Foundation Project Scoping Workshop, the purpose of which was to assess the current status of calculations for the nuclear matrix elements governing neutrinoless double-beta decay and determine if more work on them is required. After reviewing important recent progress in the application of effective field theory, lattice quantum chromodynamics, and ab initio nuclear-structure theory to double-beta decay, we discuss the state of the art in nuclear-physics uncertainty quantification and then construct a roadmap for work in all these areas to fully complement the increasingly sensitive experiments in operation and under development. The roadmap includes specific projects in theoretical and computational physics as well as the use of Bayesian methods to quantify both intra- and inter-model uncertainties. Here, the goal of this ambitious program is a set of accurate and precise matrix elements, in all nuclei of interest to experimentalists, delivered together with carefully assessed uncertainties. Such calculations will allow crisp conclusions from the observation or non-observation of neutrinoless double-beta decay, no matter what new physics is at play.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-precision vapor pressure measurement apparatus with facile and inexpensive construction

This study describes an apparatus for high-precision variable temperature measurement of liquid vapor pressure. The apparatus can be used to measure the vapor pressure using only 0.5 ml of the liquid sample. To evaluate the accuracy of the device measurement, water and 2-propanol are utilized as standard liquids, and their vapor pressure is measured with a maximum uncertainty of ~1%. This apparatus can be replicated using inexpensive and commonly used laboratory fittings and fixtures, making it an indispensable tool for synthetic chemists and chemical engineers involved in the iterative synthesis of compounds, targeting different vapor–liquid equilibrium regimes.

Engineering↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Precision gamma-ray constraints for sub-GeV dark matter models

The indirect detection of dark matter particles with mass below the GeV scale has recently received significant attention. Future space-borne gamma-ray telescopes, including All-Sky-ASTROGAM, AMEGO, and GECCO, will probe the MeV gamma-ray sky with unprecedented precision, offering an exciting test of particle dark matter in the MeV-GeV mass range. While it is typically assumed that dark matter annihilates into only one Standard Model final state, this is not the case for realistic dark matter models. Here we analyze existing indirect detection constraints and the discovery reach of future detectors for the well-motivated Higgs and vector-portal models using our publicly-available code Hazma. In particular, we show how to leverage chiral perturbation theory to compute the dark matter self-annihilation cross sections into final states containing mesons, the strongly-interacting Standard Model dynamical degrees of freedom below the GeV scale. We find that future telescopes could probe dark matter self-annihilation cross sections orders of magnitude smaller than those presently constrained by cosmic microwave background, gamma-ray and terrestrial observations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision cosmology with primordial GW backgrounds in presence of astrophysical foregrounds

The era of Gravitational-Wave (GW) astronomy will grant the detection of the astrophysical GW background from unresolved mergers of binary black holes, and the prospect of probing the presence of primordial GW backgrounds. In particular, the low-frequency tail of the GW spectrum for causally-generated primordial signals (like a phase transition) offers an excellent opportunity to measure unambiguously cosmological parameters as the equation of state of the universe, or free-streaming particles at epochs well before recombination. We discuss whether this programme is jeopardised by the uncertainties on the astrophysical GW foregrounds that coexist with a primordial background. We detail the motivated assumptions under which the astrophysical foregrounds can be assumed to be known in shape, and only uncertain in their normalisation. In this case, the sensitivity to a primordial signal can be computed by a simple and numerically agile procedure, where the optimal filter function subtracts the components of the astrophysical foreground that are close in spectral shape to the signal. We show that the degradation of the sensitivity to the signal in presence of astrophysical foregrounds is limited to a factor of a few, and only around the frequencies where the signal is closer to the foregrounds. Our results highlight the importance of modelling the contributions of eccentric or intermediate-mass black hole binaries to the GW background, to consolidate the prospects to perform precision cosmology with primordial GW backgrounds.

79 ASTRONOMY AND ASTROPHYSICS↗

Expected ${\boldsymbol H \xrightarrow{} {\boldsymbol{\mu^+\mu^-}}} $ measurement precision with ${\boldsymbol { e^{+}e^{-}}{\bf \xrightarrow{}}{ \boldsymbol{Z(q\bar{q})H}}}$ production at the CEPC *

Here, a search for the dimuon decay of the Standard Model Higgs boson is performed using Monte Carlo simulated events to mimic data corresponding to an integrated luminosity of 5.6 ab -1 collected with the Circular Electron-Positron Collider detector in e + e - collisions at $\sqrt{s}$ =240 GeV. This study investigates the e + e - →ZH, Z → $q\bar{q}$, H → μ + μ - process, and the expected significance considering only the statistical uncertainty in the data for a background-only hypothesis for a Higgs boson with a mass of 125 GeV is found to be 6.1 σ, corresponding to a precision of 19%. The systematic impacts from the background Monte Carlo statistical fluctuations are estimated to be negligible. Moreover, the dependence of the measurement accuracy on the muon momentum resolution of the CEPC detector is investigated. It is found that the muon momentum resolution must be better than 204 MeV to discover the H →μμ process at the nominal integrated luminosity. If the resolution is 100% worse than the designed parameter, the integrated luminosity must be greater than 7.2 ab -1 to reach 5σ significance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision measurement of the W boson mass using the full CDF Run II data set

The mass of the W boson, a mediator of the weak force between elementary particles, is tightly constrained by the symmetries of the standard model of particle physics. After the observation of the Higgs boson, the last missing component of the model, the measurement of the W boson mass provides a stringent test of the model. A measurement of the W boson mass is presented, which used data corresponding to 8.8 fb$^{-1}$ of integrated luminosity, collected in proton-antiproton collisions at a 1.96 TeV center-of-mass energy with the CDF II detector at the Fermilab Tevatron collider. A sample of approximately 4 million W boson candidates was used to obtain a Wboson mass of 80433.5±6.4$_{stat}$ ±6.9$_{syst}$ = 80433.5±9.4 MeV, the precision of which exceeds that of all previous measurements combined. This measurement is in significant tension with the standard model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assembled to meet strict accuracy and precision requirements: wire spacing of 3 mm ± 0.5 mm and wire tension of 7 N ± 1 N across 3,964 wires per APA, and flatness within 0.5 mm over the 4 m × 2.5 m extent of each APA . Here, we describe the design, manufacture and assembly of these key detector components, with a focus on the quality assurance at each stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DCTRGAN: improving the precision of generative models with reweighting

Significant advances in deep learning have led to more widely used and precise neural network-based generative models such as Generative Adversarial Networks (Gans). We introduce a post-hoc correction to deep generative models to further improve their fidelity, based on the Deep neural networks using the Classification for Tuning and Reweighting (Dctr) protocol. The correction takes the form of a reweighting function that can be applied to generated examples when making predictions from the simulation. We illustrate this approach using Gans trained on standard multimodal probability densities as well as calorimeter simulations from high energy physics. We show that the weighted Gan examples significantly improve the accuracy of the generated samples without a large loss in statistical power. This approach could be applied to any generative model and is a promising refinement method for high energy physics applications and beyond.

47 OTHER INSTRUMENTATION↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

Signal processing to reduce dark noise impact in precision timing

We introduce a technique to mitigate the effects of low frequency noise on precision timing. The example of Dark Count Noise Rate (DCR) in Silicon Photomultipliers (SiPMs) is emphasized. This technique exploits the correlation between time shifts on the leading edge of a signal and the residual slope of the baseline (due to noise) which remains after baseline subtraction. In fast timing applications (such as for Time-of-flight particle ID) the signal arrival time is typically captured on the signal leading edge. The signal risetime is often fixed by the physics of the sensor and input circuit. Then accurate pulse timing can be achieved by correcting a leading edge threshold time (depending on a slope proportional to both the Amplitude and the risetime) to a “constant fraction” time. This compensation for time walk due to amplitude fluctuations breaks down once we introduce interference from low frequency noise on the leading edge. In this paper we demonstrate that an additional measurement of the slope at threshold can be used to correct for this noise jitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗