Search NASA⌕ Search

SEARCH · Search NASA

Results for “Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

SU-F-BRA-03: Integrating Novel Electromagnetic Tracking Hollow Needle Assistance in Permanent Implant Brachytherapy Procedures

Purpose: To report on the results of a complete permanent implant brachytherapy procedure assisted by an electromagnetic (EM) hollow needle possessing both 3D tracking and seed drop detection abilities. Methods: End-to-end in-phantom EM-assisted LDR procedures were conducted. The novel system consisted of an EM tracking apparatus (NDI Aurora V2, Planar Field Generator), a 3D US scanner (Philips CX50), a hollow needle prototype allowing 3D tracking and seed drop detection and a specially designed treatment planning software (Philips Healthcare). A tungsten-doped 30 cc spherical agarose prostate immersed in gelatin was used for the treatment. A cylindrical shape of 0.8 cc was carved along its diameter to mimic the urethra. An initial plan of 26 needles and 47 seeds was established with the system. The plan was delivered with the EM-tracked hollow needle, and individual seed drop locations were recorded on the fly. The phantom was subsequently imaged with a CT scanner from which seed positions and contour definitions were obtained. The DVHs were then independently recomputed and compared with those produced by the planning system, both before and after the treatment. Results: Of the 47 seeds, 45 (96%) were detected by the EM technology embedded in the hollow needle design. The executed plan (from CT analysis) differed from the initial plan by 2%, 14% and 8% respectively in terms of V100, D90 and V150 for the prostate, and by 8%, 7% and 10% respectively in terms of D5, V100 and V120 for the urethra. Conclusion: The average DVH deviations between initial and executed plans were within a 5% tolerance imposed for this proof-of-concept assessment. This relatively good concordance demonstrates the feasibility and potential benefits of combining EM tracking and seed drop detection for real-time dosimetry validation and assistance in permanent implant brachytherapy procedures. This project has been entirely funded by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-02: Occupational Conceptus Doses From Fluoroscopically-Guided Interventional Procedures

Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height of the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any fluoroscopically-guided interventional procedure. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

60 APPLIED LIFE SCIENCES↗

WE-DE-201-07: Measurement of Real-Time Dose for Tandem and Ovoid Brachytherapy Procedures Using a High Precision Optical Fiber Radiation Detector

Purpose: Development of a novel on-line dosimetry tool is needed to move toward patient-specific quality assurance measurements for Ir-192 HDR brachytherapy to verify accurate dose delivery to the intended location. This work describes the development and use of a nano-crystalline yttrium oxide inorganic scintillator based optical-fiber detector capable of acquiring real-time high-precision dose measurements during tandem and ovoid (T&O) gynecological (GYN) applicator Ir-192 HDR brachytherapy procedures. Methods: An optical-fiber detector was calibrated by acquiring light output measurements in liquid water at 3, 5, 7, and 9cm radial source-detector-distances from an Ir-192 HDR source. A regression model was fit to the data to describe the relative light output per unit dose (TG-43 derived) as a function of source-detector-distance. Next, the optical-fiber detector was attached to a vaginal balloon fixed to a Varian Fletcher-Suit-Delclos-style applicator (to mimic clinical setup), and localized by acquiring high-resolution computed tomography (CT) images. To compare the physical point dose to the TPS calculated values (TG-43 and Acuros-BV), a phantom measurement was performed, by submerging the T&O applicator in a liquid water bath and delivering a treatment template representative of a clinical T&O procedure. The fiber detector collected scintillation signal as a function of time, and the calibration data was applied to calculate both real-time dose rate, and cumulative dose. Results: Fiber cumulative dose values were 100.0cGy, 94.3cGy, and 348.9cGy from the tandem, left ovoid, and right ovoid dwells, respectively (total of 443.2cGy). A plot of real time dose rate during the treatment was also acquired. The TPS values at the fiber location were 458.4cGy using TG-43, and 437.6cGy using Acuros-BV calculated as Dm,m (per TG-186). Conclusion: The fiber measured dose value agreement was 3% vs TG-43 and −1% vs Acuros-BV. This fiber detector opens up new possibilities for performing patient-specific quality assurance for Ir-192 HDR GYN procedures. Funding from Coulter Foundation, Duke Bio-medical Engineering. Company is being created around the detector technology. Duke holds patents on the technology.

60 APPLIED LIFE SCIENCES↗

A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.

60 APPLIED LIFE SCIENCES↗

A Comparison of Three Types of Computer-Based Procedures: An Experiment Using the Rancor Microworld Simulator

The nuclear power industry has historically used paper-based procedures, but a shift towards computer-based procedures (CBPs) has the potential to reduce human errors, alleviate mental workload, and improve work performance. Twenty-seven participants were randomly assigned to one of three CBP types using the Rancor Microworld Simulator, and each performed two different types of operational scenarios (startup and loss of feedwater). The three CBP types varied in levels of digitalization. It was hypothesized that there would be less favorable impressions of the most basic procedures, and that these would demonstrate lower usability than types with greater digitalization. Overall, our predictions were partially supported with some interesting caveats, specifically with some performance benefits for CBPs that provided indicators but not embedded controls. We discuss our findings in terms of optimal levels of digitalization/automation within nuclear operations and suggest pathways for future directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Catalytic Template Searching as an Enzyme Function Prediction Procedure

We present an enzyme protein function identification algorithm, Catalytic Site Identification (CatSId), based on identification of catalytic residues. The method is optimized for highly accurate template identification across a diverse template library and is also very efficient in regards to time and scalability of comparisons. The algorithm matches three-dimensional residue arrangements in a query protein to a library of manually annotated, catalytic residues – The Catalytic Site Atlas (CSA). Two main processes are involved. The first process is a rapid protein-to-template matching algorithm that scales quadratically with target protein size and linearly with template size. The second process incorporates a number of physical descriptors, including binding site predictions, in a logistic scoring procedure to re-score matches found in Process 1. This approach shows very good performance overall, with a Receiver-Operator-Characteristic Area Under Curve (AUC) of 0.971 for the training set evaluated. The procedure is able to process cofactors, ions, nonstandard residues, and point substitutions for residues and ions in a robust and integrated fashion. Sites with only two critical (catalytic) residues are challenging cases, resulting in AUCs of 0.9411 and 0.5413 for the training and test sets, respectively. The remaining sites show excellent performance with AUCs greater than 0.90 for both the training and test data on templates of size greater than two critical (catalytic) residues. The procedure has considerable promise for larger scale searches.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Background Radiation Observations Procedure

This procedure will provide guidance concerning the collection of preliminary background radiation data for the Second Line of Defense (SLD) Program. Making preliminary background radiation observations is important during initial visits where radiation portal monitors (RPMs) are being considered for installation to highlight clear problem areas of high radiation that could impact RPM performance. The information collected during initial site surveys is used to document clear problem areas and guide design discussions with the stakeholders during the visit. This information also helps to guide the conceptual design of proposed locations for RPM and secondary inspection sites. This procedure groups the processes of the preliminary background radiation observations into the following steps: 1. previsit preparations and logistics, 2. procedures, and 3. use of data.

Instrumentation Related to Nuclear Science & Techn↗

Health Code Number (HCN) Development Procedure

This report provides the detailed description of health code numbers (HCNs) and the procedure of how each HCN is assigned. It contains many guidelines and rationales of HCNs. HCNs are used in the chemical mixture methodology (CMM), a method recommended by the department of energy (DOE) for assessing health effects as a result of exposures to airborne aerosols in an emergency. The procedure is a useful tool for proficient HCN code developers. Intense training and quality assurance with qualified HCN developers are required before an individual comprehends the procedure to develop HCNs for DOE.

chemical mixture methodology↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of the MPACT Resonance Data Generation Procedure

Currently, heterogeneous models are being used to generate resonance self-shielded cross-section tables as a function of background cross sections for important nuclides such as 235 U and 238 U by performing the CENTRM (Continuous Energy Transport Model) slowing down calculation with the MOC (Method of Characteristics) spatial discretization and ESSM (Embedded Self-Shielding Method) calculations to obtain background cross sections. And then the resonance self-shielded cross section tables are converted into subgroup data which are to be used in estimating problem-dependent self-shielded cross sections in MPACT (Michigan Parallel Characteristics Transport Code). Although this procedure has been developed and thus resonance data have been generated and validated by benchmark calculations, assessment has never been performed to review if the resonance data are properly generated by the procedure and utilized in MPACT. This study focuses on assessing the procedure and a proper use in MPACT.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Procedure for Performing Security Camera Optical Performance Analysis Tests

Digital security camera technologies proliferate the security marketplace with manufacturers extoling the functions, features, specifications and virtues of their cameras. A process to comparatively analyze security camera technologies using international camera analysis standards and methods provides a defensible means to assess camera image quality on a technically comparable basis. The procedures in this document use ISO standard camera test charts and camera image analysis software to perform test chart image analysis for comparative camera assessment. Step-by-step procedures for acquiring test chart images in the laboratory and producing analysis data using analysis software GUI controls and interfaces for comparative analysis of security camera image quality are detailed in this document. The procedures have been validated through the test and analysis of fixed box and 180 degree field of view multi-imager cameras as well as, fixed and varifocal lenses and analog-to-digital video encoder image quality performance attributes.

42 ENGINEERING↗

Accelerated Aging of Fast Pyrolysis Bio-Oil Using Carbonyl Titration: Laboratory Analytical Procedure (LAP)

This laboratory analytical procedure covers the accelerated aging of fast pyrolysis bio-oils. Bio-oils undergo reactions that result in physical and chemical changes over time. These changes typically result in an increase in molecular weight, decrease in some functional groups such as carbonyls, and an increase in viscosity; additionally, the aging process often leads to phase separation. Studies have shown that accelerated aging of bio-oils using this method closely mimics room temperature aging for long periods of time (over 3 years). This procedure has been developed for the accelerated aging of fast pyrolysis bio-oils only. Fast pyrolysis bio-oils are more reactive than other bio-oils (e.g., catalytic fast pyrolysis) and undergo aging much more rapidly. Therefore, this procedure should only be used for fast pyrolysis bio-oil samples.

09 BIOMASS FUELS↗

SCALE Procedure for Verified, Archived, Library of Inputs and Data (VALID)

This procedure provides a framework for preparing, reviewing, and storing model inputs and derived data so that individuals with authorized access to the Verified, Archived, Library of Inputs and Data (VALID) repository can use the inputs and data with confidence in their analyses. This procedure uses documented checks and reviews to ensure that the inputs and data were correctly generated using appropriate references. Configuration management is implemented to prevent inadvertent modification of the inputs and data or inclusion of models that have not been reviewed. This procedure also provides guidance to be followed if errors are identified or if input or data revisions are needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Suggested Record-Keeping Procedures for DDOE Energy Programs

Sixteen different programs designed to increase energy efficiency and reduce the energy cost burden for District of Columbia residents, businesses, and non-profit organizations are currently provided by the District Department of the Environment's (DDOE's) Energy Office. In the spring of 2008, DDOE asked Oak Ridge National Laboratory (ORNL) to provide assistance in its ongoing efforts to track the progress of those programs. Effective record-keeping can provide information to help managers improve their programs, be very useful in preparing quarterly reports documenting program achievements, and facilitate the performance of periodic evaluations that measure how well the various programs are achieving their objectives. The first major task in this study was to review existing documents describing DDOE's energy programs, to become familiar with the purpose and procedures of each one. The relevant documents included existing program evaluation plans, recent evaluations of DDOE's energy programs, relevant Public Service Commission orders, local regulatory filings, filings by other interested parties, and evaluation-related documents from other states. The next step was to conduct in-depth interviews with all DDOE energy program managers to obtain detailed information on each program's information needs, existing record-keeping procedures, and data collection capabilities. Those interviews were followed by discussions with DDOE evaluation staff to identify their key information requirements. Based on program goals and activities, evaluation and reporting needs, and other relevant factors revealed through the document review and in-depth interviews, we identified key items for each program on which the record-keeping effort should focus. The frequency of data collection was determined by the needs of program managers and evaluators as well as by reporting requirements. Appropriate analytical approaches to use with the data collected for each program were identified based on the evaluation-related documents reviewed and the experience of ORNL evaluators. Ideas on data entry and storage procedures were provided by interviews with information technology experts and a past ORNL examination of U.S. Department of Energy record-keeping practices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Lightning arrestor connector lead magnesium niobate qualification pellet test procedures.

Enhanced knowledge preservation for DOE DP technical component activities has recently received much attention. As part of this recent knowledge preservation effort, improved documentation of the sample preparation and electrical testing procedures for lead magnesium niobate--lead titanate (PMN/PT) qualification pellets was completed. The qualification pellets are fabricated from the same parent powders used to produce PMN/PT lightning arrestor connector (LAC) granules at HWF&T. In our report, the procedures for fired pellet surface preparation, electrode deposition, electrical testing and data recording are described. The dielectric measurements described in our report are an information only test. Technical reasons for selecting the electrode material, electrode size and geometry are presented. The electrical testing is based on measuring the dielectric constant and dissipation factor of the pellet during cooling from 280 C to 220 C. The most important data are the temperature for which the peak dielectric constant occurs (Curie Point temperature) and the peak dielectric constant magnitude. We determined that the peak dielectric constant for our procedure would be that measured at 1 kHz at the Curie Point. Both the peak dielectric constant and the Curie point parameters provide semi-quantitative information concerning the chemical and microstructural homogeneity of the parent material used for the production of PMN/PT granules for LACs. Finally, we have proposed flag limits for the dielectric data for the pellets. Specifically, if the temperature of the peak dielectric constant falls outside the range of 250 C {+-} 30 C we propose that a flag limit be imposed that will initiate communication between production agency and design agency personnel. If the peak dielectric constant measured falls outside the range 25,000 {+-} 10,000 we also propose that a flag limit be imposed.

36 MATERIALS SCIENCE↗

Procedure for Assessing the Suitability of Battery Second Life Applications after EV First Life

Using batteries after their first life in an Electric Vehicle (EV) represents an opportunity to reduce the environmental impact and increase the economic benefits before recycling the battery. Many different second life applications have been proposed, each with multiple criteria that have to be taken into consideration when deciding the most suitable course of action. In this article, a battery assessment procedure is proposed that consolidates and expands upon the approaches in the literature, and facilitates the decision-making process for a battery after it has reached the end of its first life. The procedure is composed of three stages, including an evaluation of the state of the battery, an evaluation of the technical viability and an economic evaluation. Options for battery configurations are explored (pack direct use, stack of battery packs, module direct use, pack refurbish with modules, pack refurbish with cells). By comparing these configurations with the technical requirements for second life applications, a reader can rapidly understand the tradeoffs and practical strategies for how best to implement second life batteries for their specific application. Lastly, an economic evaluation process is developed to determine the cost of implementing various second life battery configurations and the revenue for different end use applications. An example of the battery assessment procedure is included to demonstrate how it could be carried out.

25 ENERGY STORAGE↗

Improving an Acoustic Vehicle Detector Using an Iterative Self-Supervision Procedure

In many non-canonical data science scenarios, obtaining, detecting, attributing, and annotating enough high-quality training data is the primary barrier to developing highly effective models. Moreover, in many problems that are not sufficiently defined or constrained, manually developing a training dataset can often overlook interesting phenomena that should be included. To this end, we have developed and demonstrated an iterative self-supervised learning procedure, whereby models are successfully trained and applied to new data to extract new training examples that are added to the corpus of training data. Successive generations of classifiers are then trained on this augmented corpus. Using low-frequency acoustic data collected by a network of infrasound sensors deployed around the High Flux Isotope Reactor and Radiochemical Engineering Development Center at Oak Ridge National Laboratory, we test the viability of our proposed approach to develop a powerful classifier with the goal of identifying vehicles from continuously streamed data and differentiating these from other sources of noise such as tools, people, airplanes, and wind. Using a small collection of exhaustively manually labeled data, we test several implementation details of the procedure and demonstrate its success regardless of the fidelity of the initial model used to seed the iterative procedure. Finally, we demonstrate the method’s ability to update a model to accommodate changes in the data-generating distribution encountered during long-term persistent data collection.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Apollo Operations Handbook Lunar Module (LM 11 and Subsequent) Vol. 2 Operational Procedures

The Apollo Operations Handbook (AOH) is the primary means of documenting LM descriptions and procedures. The AOH is published in two separately bound volumes. This information is useful in support of program management, engineering, test, flight simulation, and real time flight support efforts. This volume contains crew operational procedures: normal, backup, abort, malfunction, and emergency. These procedures define the sequence of actions necessary for safe and efficient subsystem operation.

Source record↗