Search NASA⌕ Search

SEARCH · Search NASA

Results for “Prototypes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

A novel electro-hydraulic unit design based on a shaftless integration of an internal gear machine and a permanent magnet electric machine

In recent years, increasingly stringent emission regulations have spurred an electrification trend in off-highway vehicle technology. To address challenges such as the high cost of power electronics components, limited battery capacity, and the substantial modifications required for the vehicles, there is a pressing need to develop high-speed, cost-effective, compact, and efficient electro-hydraulic units capable of powering vehicle functions. In response to these demands, this paper introduces an innovative morphology for an electro-hydraulic unit and outlines the integration method for a crescent-type internal gear machine with a permanent magnet synchronous electric machine. The proposed morphology aims to minimize component count through a shaftless solution while incorporating a cooling system that utilizes the same working fluid as the hydraulic machine. The design approach utilizes a genetic algorithm optimization process to maximize overall energy efficiency and compactness. Insights gained from the optimization results shed light on the relationship between key design parameters and unit performance, enhancing the understanding of this electro-hydraulic unit. A prototype of the unit was manufactured and tested, demonstrating a volumetric efficiency ranging from 81 % to 97 % at a maximum rotational velocity of the pinion of 6000 rpm. Finally, these results validate both the morphology and the design approach, indicating the feasibility of designing compact electro-hydraulic units that leverage hydraulic machines with higher maximum rotational velocities than commercially available counterparts as a mean to enhance efficiency and compactness.

30 DIRECT ENERGY CONVERSION↗

Experimental characterization and analysis of phase change material-based thermal energy storage system for refrigerated display case

Refrigerated display cases that are used to store and exhibit food products in supermarkets and retail spaces consume a significant portion of the buildings’ total electricity. Importantly, the refrigeration-related energy cost and demand charges are greatly affected by the time-of-use electricity pricing and demand rates, which are at their maximum during peak hours, typically when refrigeration energy consumption is also high. Using energy storage to shift the refrigeration load from peak to off-peak hours can greatly reduce the operational costs in the supermarket. This study demonstrates a phase change material-based thermal energy storage (TES) system, specifically designed in stackable units, that can be integrated with an open vertical refrigerated display case. We perform numerical and experimental characterization that includes finite-difference modeling for the TES, prototype fabrication, and laboratory evaluation, followed by a preliminary system-level analysis to predict the impact of TES on the refrigerated case performance, energy use, and energy cost. The results show that the dedicated latent TES for refrigerated cases can provide a specific energy of 50.4 Wh/kg and a specific power of 15.5 W/kg. The TES can be charged during 12 h of the off-peak period and discharged at various rates during 4 to 6 h of the peak period, thereby shifting the refrigeration load from the peak to the off-peak period. Consequently, annual cost savings up to 19% can be achieved, depending on the thermal load, the summer/winter peak electricity pricing, and the transition temperature of the phase change material used.

25 ENERGY STORAGE↗

Investigation of a thermocapacitive cycle by aqueous supercapacitors for multifunctional heat pump and energy storage

Thermocapacitive cycles are promising thermal and energy storage cycles using supercapacitors, which can achieve thermal efficiencies over 50% of the Carnot limit. There is a lack of work investigating the use of thermocapacitive effects in practical heat pumps. Here, this paper explores the design of thermocapacitive cells with higher temperature changes to be better suited for heat pumping applications. To evaluate the cell designs on temperature changes, pouch type cells are prototyped and modeled, and tested using a micro-calorimeter. A peak adiabatic temperature span of a LiCl aqueous cell is 2.7 °C. By arranging the cells in a cascade manner, the projected adiabatic temperature span can reach up to 12 °C with a heating density of 15 kW m −3 and an energy storage density of 0.83 kWh m −3 . Models predict that this could be increased to 30 °C and 1.65 kWh m −3 through improvements to cell capacitance and thermopower. Incorporating the energy storage capabilities into heating and cooling devices can be beneficial to building thermal management as energy storage becomes increasingly important for energy system integration.

25 ENERGY STORAGE↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Multidisciplinary Design, Analysis, and Optimization (MDO) for Co-Designed Transmission & Distribution Electric Grid Planning

This paper describes early experiences and example use cases applying multi-disciplinary design analysis and optimization (MDO) to the integrated design of power grids. Adapted from aerospace, MDO enables combining multiple existing tools into a coordinated optimization. Here we use MDO to simultaneously capture integrated transmission-distribution and investment-engineering trade-offs in an automated framework. Example use cases showcase prototype interactions among existing grid models using MDO and hint at the types of integrated analyses enabled by this approach. In addition, we share experiences and thoughts on grid-specific challenges and opportunities to help advance further work in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dehumidification energy storage using a stratified liquid desiccant tank

Liquid desiccants can play an important role in reducing dehumidification energy requirements in the built environment. Because they are in a liquid state, the desiccant can be easily stored and then used to dehumidify buildings during peak energy consumption periods. By maintaining stratification between concentrated and diluted desiccant solutions, a single tank can be used to store liquid desiccant for energy storage purposes. Using a stratified tank instead of separate tanks for dilute and concentrated solutions will reduce storage costs and increase energy storage densities for liquid desiccant systems. This paper describes the experimental validation and one-dimensional modeling of a stratified liquid desiccant tank. The stratified tank prototype developed achieved 80 % of the theoretical energy storage density based on an imposed desiccant concentration change. Here, the stratified tank model was able to reasonably reproduce the experimental results. Using this model, the impact of varying operational conditions on the energy density of the stratified liquid desiccant energy storage was evaluated. Depending on the operating conditions, stratified liquid desiccant energy storage using aqueous LiCl up to 40 wt% can achieve energy storage densities in excess of 330 kWh/m 3 .

25 ENERGY STORAGE↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics↗

Design, optimization, and validation of a triply periodic minimal surface based heat exchanger for extreme temperature applications

Heat exchanger (HX) innovation offers potential for significant improvements in energy efficiency for a host of applications including but not limited to aviation and power generation cycles. Triply Periodic Minimal Surfaces (TPMS) have received significant attention in recent years due to their incredibly high surface area density, which makes them very attractive from a heat transfer point of view. Recent efforts have largely focused on thermal-hydraulic characterization of the many available TPMS and the testing of small-scale HX prototypes. However, practical implementation remains largely unexplored, partially due to the extreme computational cost associated with accurately simulating these complex structures. In this work, we present the design, simulation, and optimization of a TPMS-HX for high temperature (900 °C) and pressure (25 MPa) applications. Detailed analysis of HX sub-sections is conducted to define the smallest repeatable section which may be used to characterize the thermal-hydraulic performance of the entire HX, enabling rapid design and iteration with significantly reduced computational cost. Compared to preliminary results for a water-to-water experiment, calibrated heat transfer and pressure drop predictions were within ±5 % and ±10 %, respectively. Optimization results show a 10x increase in volumetric power density over the initial design, which is verified against a parametric exhaustive search of the HX design space. Furthermore, it was found that reducing the unit cell hydraulic diameter cell plays the largest role in increasing heat transfer, increasing the surface area density and enabling a more compact and efficient HX.

42 ENGINEERING↗

Ultra-high efficiency hydrogen production using a large-scale solid oxide electrolysis cell system

Efficient and cost-effective production of clean hydrogen is key to decarbonizing the production of hard-to-abate industries, such as chemicals, fuels, steel, cement and many other commodities that form the basis of modern societies. High-temperature steam electrolysis (HTSE) has recently become commercially available and offers opportunities for producing hydrogen at higher efficiency and lower cost than competing low temperature technologies. In this work, we report world record setting hydrogen production efficiency from large-scale prototype HTSE systems based on solid oxide electrolysis cell (SOEC) technology. Independent tests performed at Idaho National Laboratory (INL) employed a Bloom Energy 100 kW SOEC system to achieve a hydrogen production direct current specific electric energy consumption as low as 36.7 kWh per kilogram of hydrogen. Remarkably, similar high efficiencies in the range of 36–39 kW/kg-H2 were obtained over a wide range of hydrogen production rates and even during dynamic ramping as the hydrogen production and electric power consumption of the system were varied between 20 % and 100 % of nominal conditions. Furthermore, these test results validate previous projections that commercial SOEC systems can produce clean hydrogen at efficiencies approaching 100 % for less than 2 U S. dollars per kilogram when located near sources of inexpensive, low-grade heat and clean electricity.

08 HYDROGEN↗

Democratizing uncertainty quantification

Uncertainty Quantification (UQ) is vital to safety-critical model-based analyses, but the widespread adoption of sophisticated UQ methods is limited by technical complexity. In this paper, we introduce UM-Bridge (the UQ and Modeling Bridge), a high-level abstraction and software protocol that facilitates universal interoperability of UQ software with simulation codes. It breaks down the technical complexity of advanced UQ applications and enables separation of concerns between experts. UM-Bridge democratizes UQ by allowing effective interdisciplinary collaboration, accelerating the development of advanced UQ methods, and making it easy to perform UQ analyses from prototype to High Performance Computing (HPC) scale. In addition, we present a library of ready-to-run UQ benchmark problems, all easily accessible through UM-Bridge. These benchmarks support UQ methodology research, enabling reproducible performance comparisons. We demonstrate UM-Bridge with several scientific applications, harnessing HPC resources even using UQ codes not designed with HPC support.

Benchmarks↗

PDB-IHM: A System for Deposition, Curation, Validation, and Dissemination of Integrative Structures

Structures of many large biomolecular assemblies are now being determined using integrative approaches. In these approaches, information derived from multiple experimental and computational methods is combined to compute three-dimensional structures of multi-protein complexes and other macromolecular machines. A standalone prototype data resource for integrative structures called PDB-Dev was built, based on recommendations of the Integrative and Hybrid Methods (IHM) Task Force of the Worldwide Protein Data Bank (wwPDB). This effort included developing data standards and software tools for collecting, curating, validating, visualizing, archiving, and disseminating integrative structures that span diverse spatiotemporal scales and conformational states. Mechanisms have been created to validate integrative structures based on the experimental data underpinning them. Building upon this foundational framework, PDB-Dev has been further expanded to handle large dynamic macromolecular systems and integrative structures that combine, for example, experimental restraints with atomic coordinates computed by machine learning algorithms. Data standards and supporting tools have also been extended to capture information about biomolecular dynamics, such as conformational transitions and related kinetic data derived from biophysical methods. Recently, PDB-Dev was unified with the PDB archive and rebranded as PDB-IHM (pdb-ihm.org), further promoting FAIR (Findable, Accessible, Interoperable, and Reusable) principles of data stewardship for integrative structural biology.

IHMCIF↗

Post-irradiation examination of UN-Mo-W fuels for space nuclear propulsion

The National Aeronautics and Space Administration's return to space nuclear propulsion stems from the need for a more efficient method of space travel. Nuclear thermal propulsion systems have been shown to be two times more efficient than chemical propulsion. NASA's Sirius program was created to fabricate and test fuels for space nuclear propulsion, specifically to determine their performance under prototypical startup conditions. The Sirius project featured 4 test capsules, Sirius-1 featured uranium nitride fuel dispersed in a matrix of tungsten and rhenium, while Sirius-2A, -2B, and -3 featured uranium nitride-molybdenum-tungsten fuel (UN-Mo-W). This study discusses the Sirius-2A and -2B irradiation experiments at the Idaho National Laboratory, specifically their performance under irradiation at the Transient Reactor Test Facility. It was found that the fuel samples overall did not exhibit significant cracking, though the Sirius-2A fuel did have one large crack on the surface of the fuel. There was minimal hydrogen absorption in the samples, though it is unknown if the absorption occurred during irradiation or during fabrication. Mechanical testing indicated that the UN fuel demonstrated ceramic behavior as expected, and the Mo/W matrix demonstrated linear elastic behavior to failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Grain boundary self-diffusion and point defect interactions in α -U via molecular dynamics

Though metallic U-Zr fuel has been used in nuclear reactors since the 1960s, many of its fundamental and thermodynamic properties are still unknown. The a-U phase, which has a highly anisotropic crystal structure and physical properties, is present in U-Zr fuel. The character and behavior of a-U grain boundaries will strongly impact fuel thermophysical performance under irradiation. Here, we study the interaction of point defects with grain boundaries, diffusion along grain boundaries, and the predicted diffusional creep behavior of a-U via molecular dynamics. We calculate the segregation energy of vacancies and interstitials to grain boundaries and quantify the biased sink strength of the grain boundaries, and observe that this sink strength is not strongly dependent on the grain boundary orientation. We also find that grain boundary diffusivity is strongly dependent on the grain boundary energy and grain boundary orientation. The presence of point defects within the grain boundary can induce diffusion in grain boundaries with low formation energies and can enhance diffusion in high-energy grain boundaries. We also find that diffusional creep of a-U at prototypical metallic fuel operation conditions is extremely high and could help explain observed metallic fuel swelling behaviors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An integrated approach to examine fuel-cladding chemical interaction in HT9/U-10Zr metallic fast reactor fuels: Coupling machine learning with electron microscopy and local mechanical properties analysis

The metallic U-Zr nuclear fuel alloy has garnered renewed interest as a promising candidate for next-generation sodium-cooled fast reactors. Recent studies and technology assessments have identified several areas requiring improvements, enhanced knowledge, and reliable data to strengthen the U-Zr fuel design basis for qualification and commercial applications. One of the most challenging phenomena impacting this fuel system’s performance is fuel-cladding chemical interaction (FCCI). This work aimed to harvest FCCI data by examining selected HT9/U-10Zr (wt. %) fuel samples of prototypic full-length fuel pins through an integrated approach. This approach integrated scanning electron microscopy (SEM) microstructure characterization with localized mechanical properties examination to deepen understanding of FCCI phenomenon in HT9/U-10Zr fuel system. Particularly, this study focused on MFF fuel pins irradiated at Fast Flux Test Facility (FFTF), which aimed to qualify metallic fuel as a driver fuel for FFTF and to assess its viability for larger-scale fast reactors. Electron microscopy provided high confidence in detecting and distinguishing the different FCCI layers, while small-scale mechanical testing (SSMT) probed the mechanical properties of these layers. SEM examination of a MFF-2 pin 192167, with a time averaged inner cladding temperature (TICT) slightly over 500°C, revealed minimal cladding-side FCCI (cladding wastage). In contrast, significantly thicker cladding wastage comprising two distinct sublayers was observed in samples from the thermally hot MFF-3 pin 193045 and MFF-5 pin 195011 where the TICT ranged from 610-635°C. SSMT indicated complete embrittlement in the sublayer adjacent to the fuel and a tendency toward embrittlement in the other sublayer. Additionally, a new machine learning method was developed, validated, and used to quantify cladding wastage thickness. The machine learning method reliably predicted the wastage thickness across various fuel pins and sample cross-sections. Furthermore, the available cladding wastage data from HT9/U-10Zr fuel system demonstrated a strong temperature dependency. However, the dataset remains small, and ongoing research activities are essential to further understand the FCCI phenomenon and develop a reliable FCCI model for enhanced fuel performance simulation under various conditions.

36 - MATERIALS SCIENCE↗