A temporary synchronous clock source for spinning spacecraft
Breadboard model of spaceborne synchronous clock pulse generator for spinning spacecraft
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Breadboard model of spaceborne synchronous clock pulse generator for spinning spacecraft
In this work, design and performance of an annular carbon fiber cathode are presented. Measurements on this cathode were performed in a single high-voltage pulse generator (600 kV, 50 ns, and 50 {omega}) and a repetitive one (350 kV, <10 ns, 180 {omega}, and 100 Hz), respectively. In a single pulse regime, emphasis was placed on the uniformity of electron beam extracted from this cathode. It was found that this cathode could deliver uniform electron beams with current densities exceeding kA/cm{sup 2}. Cesium iodide (CsI) coating eliminated hot spots on the cathode surface, significantly improving the uniformity of electron emission. Under repetitively pulsed operation, this cathode exhibited a good shot-to-shot reproducibility at the pressure of 1.5x10{sup -4} Torr, suggesting an ability of surviving even in poor vacuum. However, once the base pressure rose up to 3.76x10{sup -4} Torr, the cathode performance gradually degraded as the pulse shot proceeded. Besides, some possible explanations for these experimental results are presented. These results show that given proper diode design, carbon fiber with CsI coating has great promise as electron emitter producing high-current electron beams.
This tutorial introduces strong-field-driven high-order harmonics, their experimental generation and characterization techniques, and their main applications including attosecond pulse generation and ultrafast spectroscopy of the target material. We begin from the use of atomic targets, where the first high-order harmonic generation (HHG) experiments were realized in the late 1980s. Then, we briefly discuss the basics of the microscopic generation mechanism and how various steps of the mechanism were exploited in applications such as generating isolated attosecond pulses and probing molecular orbitals. We introduce and describe the standard experimental approaches for condensed phase HHG, where we discuss unique technical challenges of the use of solid-state materials, such as the mitigation of plasma formation and laser damage. We cover the fundamentals of high-harmonic spectroscopy in condensed matter systems, such as wide bandgap dielectrics, semiconductors, liquid media, and 2D-crystals. We provide some examples of rapidly emerging spectroscopic capabilities, such as for probing crystal symmetries, Berry phases, and associated non-trivial topological properties of the source material. Finally, we provide an overview of the research field, including some of the challenges, opportunities, and open questions.
Nanosecond timescale underwater electrical wire explosions of ring-shaped Cu wires were investigated using a pulsed generator with a current amplitude up to 50 kA. It was shown that this type of wire explosion results in the generation of a toroidal shock wave (SW). Time- and space-resolved optical diagnostics were used to determine azimuthal uniformity of the shock wave front and its velocity. It was found that the shock wave preserves its circular front shape in the range of radii 50μm<r<5 mm. At r≤15μm, azimuthal irregularities of the SW front were obtained indicating the appearance of azimuthal instability. A surprising finding is that the shock wave propagates with a constant velocity of v{sub sw}=1.2M, where M is the Mach number. The dynamics of the leading part of the shock wave, based on the oblique shock wave theory, is presented, explaining the constant velocity of the shock wave.
Not Available
A new type of high functionality, fast, compact, and easy programmable arbitrary waveform generator for low noise physical measurements is presented. The generator provides 7 fast differential waveform channels with a maximum bandwidth up to 200 MHz frequency. There are 6 fast pulse generators on the generator board with 78 ps time resolution in both duration and delay, 3 of them with amplitude control. The arbitrary waveform generator is additionally equipped with two auxiliary slow 16 bit analog-to-digital converters and four 16 bit digital-to-analog converters for low frequency applications. Electromagnetic shields are introduced to the power supply, digital, and analog compartments and with a proper filter design perform more than 110 dB digital noise isolation to the output signals. All the output channels of the board have 50 Ω SubMiniature version A termination. The generator board is suitable for use as a part of a high sensitive physical equipment, e.g., fast read out and manipulation of nuclear magnetic resonance or superconducting quantum systems and any other application, which requires electromagnetic interference free fast pulse and arbitrary waveform generation.
The schematic of a multidimensional current pulse generator is studied. A MTKh-90 cold cathode thyratron is used as the current commutator. In the autooscillation mode on a frequency of 380 hertz the generator creates a current to 100 amps per pulse in a control resistance of 1 ohm. The pulse duration is regulated within the limits from 0.1 to 3.0 microseconds.
We report the experimental results on generating pulsed terahertz (THz) radiation, frequency-tunable within the range 0.5−2 THz. The THz pulse generation was implemented using the method of optical rectification of femtosecond laser pulses in the nonlinear organic crystal OH1. The frequency tuning of the THz radiation was provided by adaptive phase – amplitude modulation of the pump pulses from the Cr : forsterite laser system with a radiation wavelength of 1230 nm using the acoustooptical dispersion delay line. (paper)
In this project, we have investigated a broad range of atomic, molecular, and optical (AMO) processes of current significance in strong-field and ultrafast science and technology. The main goals are to develop new theoretical formalisms and accurate computational methods for ab initio and in-depth non-perturbative study of time-resolved multiphoton quantum dynamics and spectroscopy, very-high-order harmonic generation, optimal control of ultrafast attosecond pulse generation, and resonance-enhanced below threshold harmonics in intense ultrashort laser fields. We have worked on the following projects and we have published 20 top 15 % SCI journal articles during the last 3.5 years (Jan. 1, 2016 to June 30, 2019), including one article in top raking Physical Review Letters, and 3 articles in top ranking (Nature) Scientific Reports, and one Physical Review A article was chosen as Editors’ suggestion paper, etc. (a) Development of new time-dependent methods for accurate and efficient solution of multi-dimensional time-dependent Schrödinger equation and time-dependent density functional theory. (b) Non-perturbative treatment of very-high order (1000th – 5000th order) harmonic generation and broadband supercontinuum spectra from XUV to soft x-ray regime. (c) Development of synchrosqueezing transform (SST) for precision time-frequency analysis of electron multi-rescattering dynamics. (d) Exploration of the dynamical origin of resonance-enhanced near- and below-threshold harmonics. (e) Probing the high-order harmonics generation in disordered semiconductor. (f) Multiphoton ionization of one-electron relativistic diatomic quasi-molecules in strong laser fields. and, (g) New development of non-adiabatic density functional theory. The theoretical and simulation projects we have pursued are closely related to the ongoing experimental researches in several leading laboratories in the US and Europe, etc. It is expected that the outcome of this project will provide timely and significant new information and insight for the advancement of strong-field atomic and molecular physics and ultrafast science and technology.
The characterization of a dynamic surface displacement transducer (IQI Model 501) by a noncontact method is presented. The transducer is designed for ultrasonic as well as acoustic emission measurements and, according to the manufacturer, its characteristic features include a flat frequency response range which is from 50 to 1000 kHz and a quality factor Q of less than unity. The characterization is based on the behavior of the transducer as a receiver and involves exciting the transducer directly by transient pulse input stress signals of quasi-electrostatic origin and observing its response in a digital storage oscilloscope. Theoretical models for studying the response of the transducer to pulse input stress signals and for generating pulse stress signals are presented. The characteristic features of the transducer which include the central frequency f sub o, quality factor Q, and flat frequency response range are obtained by this noncontact characterization technique and they compare favorably with those obtained by a tone burst method which are also presented.
Experiments have been performed at Idaho National Laboratory to study methodology and instrumentation for performing neutron active interrogation die-away analyses for the purpose of detecting shielded fissionable material. Here we report initial work using a portable DT electronic neutron generator with a He-3 fast neutron detector to detect shielded fissionable material including >2 kg quantities of enriched uranium and plutonium. Measurements have been taken of bare material as well as of material hidden within a large plywood cube. Results from this work have demonstrated the efficacy of the die-away neutron measurement technique for quickly detecting the presence of special nuclear material hidden within plywood shields by analyzing the time dependent neutron signals in-between neutron generator pulses. Using a DT electronic neutron generator operating at 300 Hz with a yield of approximately 0.36 x 10**8 neutrons per second, 2.2 kg of enriched uranium hidden within a 0.60 m x 0.60 m x 0.70 m volume of plywood was positively detected with a measurement signal 2-sigma above the passive background within 1 second. Similarly, for a 500 second measurement period a lower detection limit of approaching the gram level could be expected with the same simple set-up.
A new, fast, single-pulse x-ray diffraction (XRD) diagnostic for determining phase transitions in shocked polycrystalline materials has been developed. The diagnostic consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, producing line and bremsstrahlung x-ray emission in a 35-ns pulse. The characteristic Kα lines from the selected anodes of silver and molybdenum are used to produce the diffraction patterns, with thin foil filters employed to remove the characteristic Kβ line emission. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 3-mm by 6-mm spot and 1° full-width-half-maximum (FWHM) angular divergence in a Bragg-reflecting geometry. For the experiments described in this report, the angle between the incident beam and the sample surface was 8.5°. A Debye-Scherrer diffraction image was produced on a phosphor located 76 mm from the polycrystalline sample surface. The phosphor image was coupled to a charge-coupled device (CCD) camera through a coherent fiberoptic bundle. Dynamic single-pulse XRD experiments were conducted with thin foil samples of tin, shock loaded with a 1-mm vitreous carbon back window. Detasheet high explosive with a 2-mm-thick aluminum buffer was used to shock the sample. Analysis of the dynamic shock-loaded tin XRD images revealed a phase transformation of the tin beta phase into an amorphous or liquid state. Identical experiments with shock-loaded aluminum indicated compression of the face-centered-cubic (fcc) aluminum lattice with no phase transformation.
A single-pulse x-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line and bremsstrahlung x-ray emission in a 40-ns pulse. A selected anode of either silver or molybdenum produces characteristic K lines used for diffraction. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2-mm by 5-mm spot and 1° full-width-half-maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock-loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.
Operation and components of density probe high voltage pulse generator, manipulator control, and pressure transducers used for flow visualization
Transferring high-level waste (HLW) between storage tanks or to treatment facilities is a common practice performed at the Department of Energy (DoE) sites. Changes in the chemical and/or physical properties of the HLW slurry during the transfer process may lead to the formation of blockages inside the pipelines resulting in schedule delays and increased costs. To improve DoE's capabilities in the event of a pipeline plugging incident, FIU has continued to develop two novel unplugging technologies: an asynchronous pulsing system and a peristaltic crawler. The asynchronous pulsing system uses a hydraulic pulse generator to create pressure disturbances at two opposite inlet locations of the pipeline to dislodge blockages by attacking the plug from both sides remotely. The peristaltic crawler is a pneumatic/hydraulic operated crawler that propels itself by a sequence of pressurization/depressurization of cavities (inner tubes). The crawler includes a frontal attachment that has a hydraulically powered unplugging tool. In this paper, details of the asynchronous pulsing system's ability to unplug a pipeline on a small-scale test-bed and results from the experimental testing of the second generation peristaltic crawler are provided. The paper concludes with future improvements for the third generation crawler and a recommended path forward for the asynchronous pulsing testing. (authors)
The generation of an extreme water state (130 GPa, 5000 K, and 3.4 g/cm{sup 3}) which is characterized as dense plasma at the axis of a converging shock wave is reported. A 4 kJ pulse generator was used to explode a 40 Cu-wire array, generating a cylindrical shock wave. The measured shock wave trajectory and energy deposited into the water flow were used in hydrodynamic simulations coupled with the equation of state to determine the water parameters. The temperature estimated using the emission data of water in the vicinity of the implosion axis agrees with the simulation results, indicating shock wave symmetry in such extreme conditions.
Modern concepts for next generation pulsed power (NGPP) are slated to deliver up to ten times the energy of Z today. An increase of this magnitude is concerning insofar that Z currently exhibits sizable amounts of inner magnetically insulated transmission line (MITL) loss current on the order of 5-10%. Loss phenomenon in these systems are complex and electrode heating and subsequent thermal desorption are a leading cause. Rapid heat-driven thermal desorption of contaminants scales as the square of the current. Therefore, even a modest doubling of drive current would yield an ~ 4X in non-linear surface electrode heating, quickening thermal desorption-based current loss. Exacerbating these physics is a current inability to measure ultra fast heating rates (>20°C/ns), which are paramount to benchmarking and code validation critical to NGPP design – as an empirical approach is not viable. Therefore, Ultrafast Photoluminescent Surface Heating Optical Thermometry (UP-SHOT) was developed as a new diagnostic for measurement of GHz-scale electrode heating. The discovery of UP-SHOT leveraged expertise in Engineering Science, Material Science, Pulsed-Power, and the Center for Integrated Nanotechnologies. This report includes information on: 1) The preparation of zinc oxide (ZnO) films, characterization, post-deposition treatments 2) Time-resolved photoluminescence at elevated temperatures and thermographic sensitivity
Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined before and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.