Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantum interference devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

QUPITER -- Space Quantum Sensors for Jovian-Bound Dark Matter

We propose utilizing space quantum sensors to detect ultralight dark matter (ULDM) bound to planetary bodies, focusing on Jupiter as the heaviest planet in the solar system. Leveraging Jupiter's deep gravitational potential and the wealth of experience from numerous successful missions, we present strong sensitivity projections on the mass and couplings of scalar ULDM. Future space missions offer unique opportunities to probe the ULDM interactions using quantum sensors, including superconducting quantum interference device (SQUID) magnetometers. By measuring dark matter-induced magnetic field oscillations, we expect to achieve sensitivity orders of magnitude beyond the terrestrial probes and significantly improve detection prospects of theoretically motivated ULDM candidates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scanning magnetic imaging of Sr2RuO4

We magnetically imaged the ab-plane surface of single crystals of the unconventional superconductor Sr{sub 2}RuO{sub 4}, including one sample with an array of microholes, using scanning superconducting quantum interference device and Hall probe microscopy in a dilution refrigerator at low applied magnetic fields. The images show dilute trapped vortices, as would be expected in conventional type-II superconductors, and no other magnetic features. We found no direct signs of the spontaneous magnetization that would be expected in a time-reversal symmetry-breaking (TRSB) superconductor. These measurements set upper limits on the presence of TRSB signatures in this material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Squid detected NMR and MRI at ultralow fields

Nuclear magnetic resonance (NMR) signals are detected in microtesla fields. Prepolarization in millitesla fields is followed by detection with an untuned dc superconducting quantum interference device (SQUID) magnetometer. Because the sensitivity of the SQUID is frequency independent, both signal-to-noise ratio (SNR) and spectral resolution are enhanced by detecting the NMR signal in extremely low magnetic fields, where the NMR lines become very narrow even for grossly inhomogeneous measurement fields. MRI in ultralow magnetic field is based on the NMR at ultralow fields. Gradient magnetic fields are applied, and images are constructed from the detected NMR signals.

47 OTHER INSTRUMENTATION↗

Quantum Hall–based superconducting interference device

We present a study of a graphene-based Josephson junction with dedicated side gates carved from the same sheet of graphene as the junction itself. These side gates are highly efficient and allow us to modulate carrier density along either edge of the junction in a wide range. In particular, in magnetic fields in the 1- to 2-T range, we are able to populate the next Landau level, resulting in Hall plateaus with conductance that differs from the bulk filling factor. When counter-propagating quantum Hall edge states are introduced along either edge, we observe a supercurrent localized along that edge of the junction. Here, we study these supercurrents as a function of magnetic field and carrier density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconducting (Ba,K)Fe 2 As 2 epitaxial films on single and bicrystal SrTiO 3 substrates

The realization of single crystal and bicrystal films of superconducting materials is of great interest because they allow the investigation of the intragrain performance as well as the understanding of potential limitations in the grain boundary transparency. For many years, the realization of a high-quality (Ba,K)Fe 2 As 2 film has been challenging. Here, the realization of (Ba,K)Fe 2 As 2 epitaxial thin films on single crystal SrTiO 3 (001) and [001]-tilt-type SrTiO 3 bicrystal substrates with high superconducting properties is demonstrated. The epitaxial growth of (Ba,K)Fe 2 As 2 was enabled by implementing an undoped BaFe 2 As 2 buffer layer between the SrTiO 3 substrate and (Ba,K)Fe 2 As 2 film. The film exhibits a high T c of 38.0 K and an extremely high J c of 14.3 MA/cm 2 at 4.2 K. Artificial grain boundaries of (Ba,K)Fe 2 As 2 were also successfully achieved on bicrystals with misorientation angles up to 36.8° by the same preparation methods. The artificial grain boundaries exhibited an identical T c of 38.0 K and an excellent transfer of the grain orientation from the bicrystal substrates with high crystallinity comparable to that of the high-quality Ba(Fe,Co) 2 As 2 films. Furthermore, this enables the investigation of the intrinsic (Ba,K)Fe 2 As 2 grain boundary nature, which will clarify its potential for superconducting applications, like Josephson junctions, wires, and magnets.

(Ba,K)Fe2As2↗

Reproducibility and calibration of MMC-based high-resolution gamma detectors

Here, we describe a prototype γ-ray detector based on a metallic magnetic calorimeter with an energy resolution of 46 eV at 60 keV and a reproducible response function that follows a simple second-order polynomial. The simple detector calibration allows adding high-resolution spectra from different pixels and different cool-downs without loss in energy resolution to determine γ-ray centroids with high accuracy. As an example of an application in nuclear safeguards enabled by such a γ-ray detector, we discuss the non-destructive assay of 242 Pu in a mixed-isotope Pu sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic resonance imaging without field cycling at less than earth's magnetic field

A strong pre-polarization field, usually tenths of a milli-tesla in magnitude, is used to increase the signal-to-noise ratio in ordinary superconducting quantum interference device-based nuclear magnetic resonance/magnetic resonance imaging experiments. Here, we introduce an experimental approach using two techniques to remove the need for the pre-polarization field. A dynamic nuclear polarization (DNP) technique enables us to measure an enhanced resonance signal. In combination with a π/2 pulse to avoid the Bloch-Siegert effect in a micro-tesla field, we obtained an enhanced magnetic resonance image by using DNP technique with a 34.5 μT static external magnetic field without field cycling. In this approach, the problems of eddy current and flux trapping in the superconducting pickup coil, both due to the strong pre-polarization field, become negligible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrical, optical, and magnetic properties of amorphous yttrium iron oxide thin films and consequences for non-local resistance measurements

We present magnetic characterization, charge resistivity, and optical photoluminescence measurements on amorphous yttrium iron oxide thin films ( ⁠a-Y–Fe–O), with supporting comparisons to amorphous germanium (⁠ a-Ge) films. We measured magnetic properties with both SQUID magnetometry and polarized neutron reflectometry. These results not only confirm that a-Y–Fe–O is a disordered magnetic material with strong predominantly antiferromagnetic exchange interactions and a high degree of frustration, but also that it is best understood electrically as a disordered semiconductor. As with amorphous germanium, a-Y–Fe–O obeys expectations for variable-range hopping through localized electron states over a wide range of temperature. We also clarify the consequences of charge transport through such a semiconducting medium for non-local voltage measurements intended to probe spin transport in nominally insulating magnetic materials. We further compare non-local resistance measurements made with “quasi-dc” automated current reversal to ac measurements made with a lock-in amplifier. These show that the “quasi-dc” measurement has an effective ac current excitation with frequency up to approximately 22 Hz, and that this effective ac excitation can cause artifacts in these measurements including incorrect sign of the non-local resistance. Here, this comprehensive investigation of non-local resistance measurements in a-Y–Fe–O shows no evidence of spin transport on micrometer length scales, which is contrary to our original work, and in line with more recent investigations by other groups.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary searches for spin-dependent interactions using sidebands of nuclear spin-precession signals

Various theories beyond the Standard Model predict new particles with masses in the sub-eV range with very weak couplings to ordinary matter. A new P-odd and T-odd interaction between polarized and unpolarized nucleons proportional to s⃗⋅r̂ is one such possibility, where r⃗=rr̂ is the spatial vector connecting the nucleons, and s⃗ is the spin of the polarized nucleon. Such an interaction involving a scalar coupling gsN at one vertex and a pseudoscalar coupling gpn at the polarized nucleon vertex can be induced by the exchange of spin-0 pseudoscalar bosons. We describe a new technique to search for interactions of this form and present the first measurements of this type. We show that future improvements to this technique can improve the laboratory upper bound on the product gsNgpn by two orders of magnitude for interaction ranges at the 100 micron scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Results of a New Microwave SQUID Multiplexer

We are developing a proof-of-concept microwave SQUID multiplexer containing four SQUIDs coupled to GHz frequency resonant circuits and fed with a single microwave readout line. The resonators are half-wave coplanar waveguide sections and are similar to the structures used for the microwave kinetic inductance detectors developed in our group. Optimal values for the interdigital gap capacitors were determined to maximize the sensitivity of the transmitted and reflected microwave signal with respect to changes in the dynamic resistance of the SQUID. The dc current-bias line for the SQUID has an in-line inductive high frequency filter to minimize coupling between the bias line and resonator. A high frequency modulation scheme is proposed to eliminate the need for individual flux biasing of the SQUIDs, which extends the dynamic range of the readout. In this scheme a common modulation signal is imposed on each SQUID and the received signal is demodulated at one and two times the modulation frequency to maintain sensitivity at any flux state. We present the recent results of the microwave SQUID multiplexer system operating at a readout frequency range of 10 - 11GHz.

superconducting quantum interference device (SQUID↗

Mitigation of Finite Bandwidth Effects in Time-Division-Multiplexed SQUID Readout of TES Arrays

Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.

Transition-edge sensors↗

Electrostatic gate-controlled quantum interference in a high-mobility two-dimensional electron gas at the (La 0.3 ⁢Sr 0.7 )(Al 0.65 ⁢Ta 0.35 )O 3 /SrTiO 3 interface

Here, we report quantum oscillations in magnetoresistance that are periodic in magnetic field (𝐵), observed at the interface between (La 0.3 ⁢Sr 0.7 )(Al 0.65 ⁢Ta 0.35 )O 3 and SrTiO 3 . Unlike Shubnikov–de Haas oscillations, which appear at magnetic fields > 7 T and diminish quickly as the temperature rises, these 𝐵-periodic oscillations emerge at low fields and persist up to 10 K. Their amplitude decays exponentially with both temperature and field, specifying dephasing of quantum interference. Increasing the carrier density through electrostatic gating results in a systematic reduction in both the amplitude and frequency of the oscillations, with complete suppression beyond a certain gate voltage. We attribute these oscillations to the Altshuler-Aronov-Spivak effect, likely arising from naturally formed closed-loop paths due to the interconnected quasi-one-dimensional conduction channels along SrTiO 3 domain walls. The relatively long phase coherence length (≃ 1.8 µ⁢m at 0.1 K), estimated from the oscillation amplitude, highlights the potential of complex oxide interfaces as a promising platform for exploring quantum interference effects and advancing device concepts in quantum technologies, such as mesoscopic interferometers and quantum sensors.

36 MATERIALS SCIENCE↗

Gate-tunable Veselago interference in a bipolar graphene microcavity

The relativistic charge carriers in monolayer graphene can be manipulated in manners akin to conventional optics. Klein tunneling and Veselago lensing have been previously demonstrated in ballistic graphene pn-junction devices, but collimation and focusing efficiency remains relatively low, preventing realization of advanced quantum devices and controlled quantum interference. Here, we present a graphene microcavity defined by carefully-engineered local strain and electrostatic fields. Electrons are manipulated to form an interference path inside the cavity at zero magnetic field via consecutive Veselago refractions. The observation of unique Veselago interference peaks via transport measurement and their magnetic field dependence agrees with the theoretical expectation. We further utilize Veselago interference to demonstrate localization of uncollimated electrons and thus improvement in collimation efficiency. Our work sheds new light on relativistic single-particle physics and provide a new device concept toward next-generation quantum devices based on manipulation of ballistic electron trajectory.

36 MATERIALS SCIENCE↗

Strong Aharonov-Bohm quantum interference in simply connected LaAlO 3 /SrTiO 3 structures

We report Aharonov-Bohm (AB) type quantum interference in simply connected devices created at the LaAlO 3 /SrTiO 3 interface using conductive atomic force microscope (c-AFM) lithography. The oscillations are multiperiodic functions of magnetic field strength, and they exhibit a substantial magnetic hysteresis with frequencies that depend on the magnetic sweep direction. The oscillation amplitude for the lowest two frequencies approaches $e^2/h$, consistent with the theoretical maximum for the AB effect, and harmonics up to third order are observable. Broadband quasiperiodic behavior is reported in a fraction of simply connected electron waveguide devices that exhibit magnetic asymmetries. Curiously, nanoscale ring devices that are multiply connected lack signatures of AB quantum interference. In this work, the interference phenomena are associated with an inhomogeneous magnetic landscape within theLaAlO 3 /SrTiO 3 nanostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin-helical detection in a semiconductor quantum device with ferromagnetic contacts

Spin-helical states, which arise in quasi-one-dimensional (1D) channels with spin-orbital (SO) coupling, underpin efforts to realize topologically protected quantum bits based on Majorana modes in semiconductor nanowires. Detecting helical states is challenging due to non-idealities present in real devices. Past efforts have focused on devices with normal contacts. In contrast, here we show by means of tight-binding calculations that by using ferromagnetic contacts it is possible to detect helical modes with high sensitivity even in the presence of realistic device effects, such as quantum interference. We show that by taking advantage of the spin-selective transmission properties of helical states, new transport signatures become possible. In addition, we show that spin-polarized contacts provide a unique path to investigate the spin-texture and spin-momentum locking properties of helical states. Our results are of interest not only for the ongoing development of Majorana qubits, but also for realizing possible spin-based quantum devices, such as quantum spin modulators and interconnects based on spin-helical channels.

36 MATERIALS SCIENCE↗