Search NASA⌕ Search

SEARCH · Search NASA

Results for “R value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Technology Solutions Case Study: Hygrothermal Performance of a Double-Stud Cellulose Wall

Moisture problems within the building shell can be caused by a number of factors including excess interior moisture that is transported into the wall through air leakage and vapor drive, bulk water intrusion from leaks and wind-driven rain, capillary action from concrete to wood connections, and through wetted building materials such as siding wetted from rain splash back. With the increasing thickness of walls, moisture issues could increase. Several builders have successfully used “double-wall” systems to more practically achieve higher R-values in thicker framed walls. A double wall typically consists of a load-bearing external frame wall constructed with 2 × 4 framing at 16 in. on center using conventional methods. After the building is enclosed, an additional frame wall is constructed several inches inside the load-bearing wall. Several researchers have used moisture modeling software to conduct extensive analysis of these assemblies; however, little field research has been conducted to validate the results. In this project, the Building America research team Consortium for Advanced Residential Buildings monitored a double-stud assembly in climate zone 5A to determine the accu¬racy of moisture modeling and make recommendations to ensure durable and efficient assemblies.

Building America↗

Technology Solutions Case Study: Cladding Attachment Over Thick Exterior Insulating Sheathing

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. Insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. Although the approach has proven effective, there is resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly. In this project, researchers from Building Science Corporation, a Building America team, investigated these issues to better understand the mechanics behind this method of cladding attachment

BSC↗

New Whole-House Solutions Case Study: Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

BA-PIRC↗

Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.

BA-PIRC↗

Heavy metals and trace elements in the groundwater in El Paso, Texas

The chemical elements studied here (Al, As, Ba, Cd, Cr, Cu, Fe, Pb, Mn, Hg, Ni, Se, Ag, Zn, Li, B) include toxic heavy metals and non-toxic elements which have occurred at high levels in El Paso, TX groundwater (Fe, Cu, Mn, As, Pb; up to 24,000, 17,000, 3200, 95, and 1000 ppb respectively). The objective of this study is to investigate the origins of these heavy metals in the groundwater. Previous works found some of these metals in the rocks of the mountains that recharge the watershed, and sufficient evidence for natural origins of arsenic in the groundwater. Statistical analyses in this report are consistent with natural origin also for the heavy metals studied but cannot dismiss human activity as a contributing factor. Interesting correlations with R-value>0.60, p-value<0.01 warrant further analysis.

Marquez B, Elia↗

Probabilistic Risk Assessment of Spent Fuel Pool Cooling System Failure Considering Safety and Security Initiating Events

In order to quantify the probable risk associated with a safety system, nuclear safety risk evaluation process is applied which is generally performed in three steps. The first step is to calculate the damage frequency of a critical system. This step is followed by the radioactive source term estimation due to the potential system damage. The final step is the assessment of off-site consequences. The safety risk formula is shown by Eq. (1). P{sub F} is the probability of safety system failure (the probability used describes a random, independent event), and C is the consequence value. R{sub SAF} = P{sub F} * C (1) The security risk associated with an attack on critical infrastructure and/or special nuclear materials theft is usually evaluated using three- term risk equation (probability of attack, probability of adversary success, and consequence). A security threat and the related initiating events are not considered in a pure safety risk analysis. The vulnerability of the physical protection system is performed independently even though the consequence resulting from a security initiating event can be similar to a safety related initiating event and thus gets double counted. The security risk can be calculated using Eq. (2) R{sub SEC} = P{sub A} * P{sub S} * C (2) PA is the probability of attack, P{sub S} is the probability of adversary success (P{sub S} = 1 - P{sub I} P{sub N}). P{sub I} being the probability of interruption which accounts for the probabilities of detection of all timely detection elements along an adversary path. PN being the probability of neutralization: the result of engagement of the response force with the adversaries after the interruption has occurred. C is the consequence magnitude from a successful attack. The two security probabilities do not describe random, independent events. As a result, because of the differences in the randomness and independence of the respective safety and security probabilities, the safety and the security risks are currently calculated separately. The consequence term in nuclear safety and security risk evaluation have the same definition. An effort is made here to study the effect on the overall risk by considering security initiating events along with the subsequent failure of the intermediate safety element. The target selected is a spent fuel storage pool for analyzing the public risk arising from the interplay between nuclear security and safety initiating events. EASI (Estimate of Adversary Sequence Interruption) model is used to calculate the probability of interruption related to a security system that leads to the calculation of the security initiating event frequency. Further progression of this initiating security event to a top event is analyzed using a Probabilistic Safety Assessment (PSA) tool, SAPHIRE (version 8) to obtain a joint pool damage frequency. For the progression of events leading to a top event, the failure of the intermediate safety elements is assumed to be external random events such as heavy load drop and fire events. The objectives of this study is to (1) determine the double accounting of frequency of failure, risk and allocated resources in the scenario of a non-random security initiating event leading to a safety random event chain (2) compare the damage frequency from pure security with the frequency of combined security-safety failure event and pure safety failure events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Retrofittable Thermal Switches for Dynamic Building Envelopes Integrated with Thermal Energy Storage: Preprint

Buildings in the United States consume about 40 quadrillion BTU of primary energy annually, which accounts for the nation's 40% of total energy use, 75% of all electricity use, and 35% of the net carbon emissions. Deploying thermal energy storage in the form of phase change material (PCM) in building envelopes is an effective method to reduce space heating/cooling loads, provide load shedding, and shift demand to periods of lower energy cost. However, the full potential of PCM-integrated envelopes can only be realized if the PCM undergoes complete phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Conventional thermal insulation (with a fixed thermal resistance) limits PCM utilization, particularly with the increasing emphasis on higher R-value in building envelopes, which negatively affects the energy-saving potential of a PCM-integrated envelope. In contrast, dynamic building envelopes integrated with PCMs provide the option of varying the thermal resistance based on the indoor and outdoor conditions, thereby enhancing utilization of free ambient cooling and heating to charge/discharge the PCM thermal storage, reducing the buildings' heating and cooling load, and shifting the peak energy demand. In this study, we demonstrate innovative retrofittable thermal switches in the form of the insertable plugs inside an insulation to provide variable thermal resistance depending on the operating temperature and direction of temperature gradient, thus allowing preferential directional heat flow. Notably, they are passive in nature, requiring no external power, and work solely based on the ambient temperature.

buildings↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Thermal Performance of Spandrel Assemblies in Glazed Wall Systems: Laboratory Test Design – Challenges and Test Results

Accurate thermal performance calculation procedures for opaque spandrel areas in curtain wall and window wall systems are essential for rating systems when comparing spandrel systems. However, there is a lack of consensus in thermal modeling needed for accurately characterizing heat transfer through spandrel assemblies due to the complex arrangement of materials and structural components. Several studies indicate that conventional 2D thermal simulations may overestimate R-values by 30% compared to physical testing and 3D simulations. Detailed simulations and well-curated laboratory test data are necessary to build confidence in simulation models, which will later be used to develop correlations to improve widely used conventional 2D thermal simulations. This study aims to experimentally test heat transfer through various spandrel assemblies to validate 3D simulation models. Also, the challenges of conducting a thorough testing design along with the solutions would be documented. The team developed a design for testing spandrel assemblies, making appropriate modifications to the existing heat, air, and moisture (HAM) chamber to accommodate the testing needs. Two moveable baffles were designed and fabricated to guide airflow direction parallel to the test article surface. The data acquisition capabilities in the chamber were upgraded to add more than two hundred sensors to the climate and indoor side of the chamber. The goal is to provide a quality dataset for validating complex 3D modeling simulations, which will be used to develop improved thermal simulation techniques that more accurately represent the thermal behavior of spandrel assemblies and their integration within the building envelope. This paper will summarize the results for the boundary conditions of the testing and the temperature variation across different locations of the spandrel assemblies.

Kunwar, Niraj [ORNL] (ORCID:0000000263457652)↗

Improved Structures of Full-Length P97, An AAA ATPase: Implications for Mechanisms of Nucleotide-Dependent Conformational Change

The ATPases associated with various cellular activities (AAA) protein p97 has been implicated in a variety of cellular processes, including endoplasmic reticulum-associated degradation and homotypic membrane fusion. p97 belongs to a subgroup of AAA proteins that contains two nucleotide binding domains, D1 and D2. We determined the crystal structure of D2 at 3.0 {angstrom} resolution. This model enabled rerefinement of full-length p97 in different nucleotide states against previously reported low-resolution diffraction data to significantly improved R values and Ramachandran statistics. Although the overall fold remained similar, there are significant improvements, especially around the D2 nucleotide binding site. The rerefinement illustrates the importance of knowledge of high-resolution structures of fragments covering most of the whole molecule. The structures suggest that nucleotide hydrolysis is transformed into larger conformational changes by pushing of one D2 domain by its neighbor in the hexamer, and transmission of nucleotide-state information through the D1-D2 linker to displace the N-terminal, effector binding domain.

36 MATERIALS SCIENCE↗

The I{sub C}R{sub N} value in intrinsic Josephson tunnel junctions in Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} (Bi2212) mesas.

The c-axis current-voltage I(V) characteristics have been obtained on a set of mesas of varying height sculpted on Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} (Bi2212) crystals intercalated with HgB{sub 2}. The intercalation, along with the small number of junctions in the mesa, N = 6-30, minimizes the degree of self-heating, leading to a consistent Josephson critical current, I{sub C}, among junctions in the mesa. The Bi2212 crystals with a bulk T{sub C} = 74 K are overdoped and display negligible pseudogap effects allowing an accurate measure of the normal state resistance, R{sub N}. These properties make the mesas nearly ideal for the determination of the Josephson I{sub C}R{sub N} product. We find I{sub C}R{sub N} values consistently {approx}30% of the quasiparticle gap parameter, {Delta}/e, which was measured independently using a mechanical contact, break junction technique. The latter was necessitated by higher bias heating effects in the mesas which prevented direct measurements of the superconducting gap. These values are among the highest reported and may represent the maximum intrinsic value for I{sub C}R{sub N}. The results indicate that the c-axis transport is a mixture of coherent and incoherent tunneling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of temperature, frequency, flux density, and excitation waveform on the core loss and dynamic B-H loops of supermalloy

The availability of experimental data which characterize the performance of soft magnetic materials for the combined conditions of temperature and frequency over a wide flux density range for different types of excitation is almost nonexistent. An experimental investigation of an 80-20 Ni-Fe alloy (Supermalloy) was conducted over the temperature (T) range of 23 to 300 C, frequency (f) range of 1 to 50 kHz, and maximum flux densities (B(sub M)) from 0.1 T up to 0.7 T for both sine and square wave voltage excitation. The investigation focused on the effects of (B(sub M)), f, T, and excitation waveform on the specific core loss (SCL) and dynamic B-H loops. The results show that the ratio (R) of sine to square wave excitation specific core loss was always greater than unity for a given f and T and identical values of B(sub M). The values of R ranged from 1.07 to 1.34. The classical theory of core loss separation into a hysteresis and eddy current loss component was used to theoretically determine the lower and upper bounds on R, against which the experimental R-values were compared. The experimental R-values were also used to make a comparison of the core loss of a sine and square wave voltage driven transformer.

Schwarze, Gene E.↗

Effects of Adverse Pressure Gradient on the Incompressible Reattaching Flow Over a Rearward-Facing Step

The turbulent, incompressible reattaching flow over a rearward-facing step has been studied by many researchers over the years. One of the principal quantities determined in these experiments has been the distance from the step to the point (or region) where the separated shear layer reattaches to the surface (x(r)). The values for x(r)/h, where h is the step height, have covered a wider range than can reasonably be attributed to experimental technique or inaccuracy. Often the reason for a largely different value of x(r)/h can be attributed to an incompletely developed turbulent layer, or a transitional or laminar boundary layer. However, for the majority of experiments where the boundary layer is believed to be fully developed and turbulent, x(r)/h still varies several step heights; generally, 5 1/2 approximately < x(r)/h approximately < 7 1/2. This observed variation has usually been attributed to such variables as l/h (step length to height, h/delta (step height to initial boundary-layer thickness), R(e)(theta)), or the experimental technique for determining reattachment location. However, there are so many different combinations of variables in the previous experiments that it was not possible to sort out the effects of particular conditions on the location of reattachment. In the present experiment velocity profiles have been measured in and around the region of separated flow. Results show a large influence of adverse pressure gradient on the reattaching flow over a rearward-facing step that has not been reported previously. Further, the many previous experiments for fully developed, turbulent flow in parallel-walled channels have shown a range of reattachment location that has not been explained by differences in initial flow conditions. Although these initial flow conditions might contribute to the observed variation of reattachment location, it appears that the pressure gradient effect can explain most of that variation.

Kuehn, Donald M.↗

2021 Monthly Rice Production in Chinese Coastal Provinces

This paper explores the dynamics of rice production in the Chinese provinces of Liaoning, Jilin, Heilongjiang, Shanghai, Jiangsu, and Zhejiang and seeks to predict monthly rice production in the months of April through October using precipitation and Normalized Difference Vegetation Index as the predictor variables available. We utilize ridge and lasso regression models to predict the rice yield. Results indicate that a lasso regression model with an R 2 value of 0.9991501 with an adjusted R 2 value of 0.9991502 and a ridge regression model with an R 2 value of 0.9865443 with an adjusted R 2 value of 0.9870637 are possible. The lasso regression model does not account for all predictor variables while the ridge regression model does. Both models could be expanded upon to include more observations.

Tubbs, Heidi↗

A New Generation of Building Insulation by Foaming Polymer Blend Materials with CO 2

Advanced thermal insulation is among the most effective technologies in transforming our nation’s energy system and contributing to DOE’s stated goal of 50% less building energy consumption by 2030. The installation of an advanced thermal insulation would prevent energy waste without the need for any maintenance, and ISTN conservatively estimates that the commercialization of such a new technology would contribute to annual U.S. energy savings of 0.361 Quads and $8 billion in annual economic savings. The key challenge to improving building insulation is to maintain and surpass the industry standard of R-5 per inch insulation value in a cost-competitive manner. Improvements in R-value without cost-efficiency are not likely to impact the market given the cost-sensitive nature of the construction industry (insulation is already the lowest-cost component of the building envelope). However, significantly higher insulating value at competitive costs is extremely appealing to the market given the greater potential to save on energy consumption and costs over the long-term. Thus, our goal is to develop a super-thermal insulation with 50% greater insulation value (R-9 to R-10 per inch) and manufacturing costs that are equal on a per-R-value basis (< $0.70/ft 2 ).

36 MATERIALS SCIENCE↗

Seeing red in M32: Constraints on the stellar content from near- and mid-infrared observations and applications for studies of more distant galaxies {sup ,} {sup ,}

The properties of asymptotic giant branch (AGB) stars in the Local Group galaxy M32 are investigated using ground- and space-based observations that span the 1-8 μm wavelength interval, with the goal of demonstrating the utility of infrared observations as probes of stellar content. Comparisons with isochrones indicate that the brightest resolved stars in M32 have ages of a few gigayears and are younger on average than AGB stars with the same intrinsic brightness in the outer disk of M31. Accounting for stellar variability is shown to be essential for modeling AGB luminosity functions (LFs). Model LFs that assume the star-forming history measured by Monachesi et al. and the variability properties of Galactic AGB stars match both the K and [5.8] LFs of M32. Models also suggest that the slope of the [5.8] LF between M{sub [5.8]} = –8.5 and –10.0 is sensitive to the mix of stellar ages, and a sizeable fraction of the stars in M32 must have an age older than 7 Gyr in order to match the [5.8] LF. The structural properties of M32 in the infrared are also investigated. The effective radii that are computed from near-infrared and mid-infrared isophotes are similar to those measured at visible wavelengths, suggesting that the stellar content of M32 is well mixed. However, isophotes at radii >16'' (>60 pc) in the near- and mid-infrared are flatter than those at visible wavelengths. The coefficient of the fourth-order cosine term in the Fourier expansion of isophotes changes from 'boxy' values at r < 16'' to 'disky' values at r > 48''in [3.6] and [4.5]. The mid-infrared colors near the center of M32 do not vary systematically with radius, providing evidence of a well mixed stellar content in this part of the galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic coercivity and ferromagnetic species in lunar materials

Lunar samples have reduced coercive force, high values of R sub H (ratio of remanent coercive force to coercive force), and constriction in their magnetic hysteresis loops due to the presence of superparamagnetic and multidomain iron grains. The high R sub H values are also attributable to the magnetic shape effects of the iron grains. Spheres, cubes, and needles, as well as more irregular metal grains were observed. The coercive force values are quite meaningless unless the size and shape distributions are determined. The R sub H and the ratio of saturation remanence to saturation magnetization values can be considered characteristic of the size and shape modes of the ferromagnetic grains in a natural sample, and a classification of natural materials based on their hysteresis characteristics is presented with special reference to lunar samples.

Wasilewski, P.↗