Measurement Of Gas Electron Multiplier (GEM) Detector Characteristics

The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm{sup 2} active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm{sup 2} GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and {sup 55}Fe radioactive source. From the {sup 55}Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production And Characterization Of Tungsten-Based Positron Moderators

Experiments of interest in Atomic Physics require production of well-defined low-energy positron beams through a moderation process of high-energy positrons, which can be produced by either the use of a radioactive source or by accelerator based pair production process. Tungsten is one of the most commonly used moderator materials because of its reasonable efficiency, high work function and relatively low cost. In this work we present different methods to produce tungsten-based candidate moderators in a variety of shapes. We also present results from characterizing these candidate moderators by ion beam analysis and microscopy techniques.

43 PARTICLE ACCELERATORS↗

Dose received by occupationally exposed workers at a nuclear medicine department

Personal Dose Equivalent (PDE) values were determined for occupational exposed workers (OEW) at the Nuclear Medicine Department (NMD) of 'Instituto Nacional de Cancerologia' (INCan), Mexico, using TLD-100 thermoluminescent dosemeters. OEW at NMD, INCan make use of radiopharmaceuticals for diagnosis and treatment of diseases. Radionuclides associated to a pharmaceutical compound used at this Department are {sup 131}I, {sup 18}F, {sup 68}Ga, {sup 99m}Tc, {sup 111}In and {sup 11}C with main gamma emission energies between 140 and 511 keV. Dosemeter calibration was performed at the metrology department of 'Instituto Nacional de Investigaciones Nucleares' (ININ), Mexico. Every occupational worker used dark containers with three dosimeters which were replaced monthly for a total of 5 periods. Additionally, control dosemeters were also placed at a site free of radioactive sources in order to determine the background radiation. Results were adjusted to find PDE/day and estimating annual PDE values in the range between 2 mSv (background) and 9 mSv. The mean annual value is 3.51 mSv and the standard deviation SD is 0.78 mSv. Four of the 16 OEW received annual doses higher than the average +1 SD (4.29 mSv). Results depend on OEW daily activities and were consistent for each OEW for the 5 studied periods as well as with PDE values reported by the firm that performs the monthly service. All obtained values are well within the established annual OEW dose limit stated in the {sup R}eglamento General de Seguridad Radiologica{sup ,} Mexico (50 mSv), as well as within the lower limit recommended by the 'International Commission on Radiation Protection' (ICRP), report no.60 (20 mSv). These results verify the adequate compliance of the NMD at INCan, Mexico with the norms given by the national regulatory commission.

61 RADIATION PROTECTION AND DOSIMETRY↗

The half-life of {sup 131g,m}Te

In this work, the half-lives of {sup 131m}Te and {sup 131g}Te were measured. Radioactive sources of {sup 131}Te were obtained using the {sup 130}Te(n,{gamma}){sup 131}Te nuclear reaction. These nuclear parameters have been determined with a better confidence and accuracy than previously available: 18.89 {+-} 0.11 min and 33.18 {+-} 0.13 h, respectively. These results are quite helpful for new calculations that attempt to describe the low-lying levels in {sup 131}I from the decay of {sup 131g,m}Te.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The “accumulation effect” of positrons in the stack of foils, detected by measurements of the positron implantation profile

The profiles of positrons implanted from the radioactive source {sup 22}Na into a stack of foils and plates are the subject of our experimental and theoretical studies. The measurements were performed using the depth scanning of positron implantation profile method, and the theoretical calculations using the phenomenological multi-scattering model (MSM). Several stacks consisting of silver, gold and aluminum foils, and titanium and germanium plates were investigated. We notice that the MSM describes well the experimental profiles; however when the stack consisting of silver and gold foils, the backscattering and linear absorption coefficients differ significantly from those reported in the literature. We suggest the energy dependency of the backscattering coefficient for silver and gold. In the stacks which comprise titanium and germanium plates, there were observed the features, which indicate the presence of the “accumulation effect” in the experimental implantation profile. This effect was previously detected in implantation profiles in Monte Carlo simulations using the GEANT4 tool kit, and it consists in higher localization of positrons close the interface. We suppose that this effect can be essential for positron annihilation in any heterogeneous materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental investigation of silicon photomultipliers as compact light readout systems for gamma-ray spectroscopy applications in fusion plasmas

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr{sub 3} crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%–4% in the energy range E{sub γ} = 3–5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Half-life determination for {sup 108}Ag and {sup 110}Ag

In this work, the half-life of the short-lived silver radionuclides {sup 108}Ag and {sup 110}Ag were measured by following the activity of samples after they were irradiated in the IEA-R1 reactor. The results were then fitted using a non-paralizable dead time correction to the regular exponential decay and the individual half-life values obtained were then analyzed using both the Normalized Residuals and the Rajeval techniques, in order to reach the most exact and precise final values. To check the validity of dead-time correction, a second correction method was also employed by means of counting a long-lived {sup 60}Co radioactive source together with the samples as a livetime chronometer. The final half-live values obtained using both dead-time correction methods were in good agreement, showing that the correction was properly assessed. The results obtained are partially compatible with the literature values, but with a lower uncertainty, and allow a discussion on the last ENSDF compilations' values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Future short baseline neutrino searches with nuclear decays

Several anomalies coming from neutrino experiments may be pointing towards new physics: these hints suggest the existence of one (or more) sterile neutrinos. We discuss some of the experiments proposed to verify (or disproof) this hypothesis by using an intense radioactive source in proximity of large neutrino detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Silicon detectors for monitoring neutron beams in n-TOF beamlines

During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing {sup 6}Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stress analysis for wall structure in mobile hot cell design

Malaysian Nuclear Agency is developing a Mobile Hot Cell (MHC) in order to handle and manage Spent High Activity Radioactive Sources (SHARS) such as teletherapy heads and irradiators. At present, there are only two units of MHC in the world, in South Africa and China. Malaysian Mobile Hot cell is developed by Malaysian Nuclear Agency with the assistance of IAEA expert, based on the design of South Africa and China, but with improved features. Stress analysis has been performed on the design in order to fulfil the safety requirement in operation of MHC. This paper discusses the loading analysis effect from the sand to the MHC wall structure.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of Martian meteorites with earth composition: Study of effective atomic numbers in the energy range 1 keV-100 GeV

Effective atomic (Z{sub eff}) and electron numbers (N{sub eff}) for 24 Martian meteorites have been determined in the energy range from 1 keV to 100 GeV and also for sixteen significant energies of commonly used radioactive sources. The values of Z{sub eff} and N{sub eff} for all sample were obtained from the DirectZeff program. The obtained results for Martian meteorites have been compared with the results for Earth composition and similarities or differences also evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of radiological data of some amino acids in the energy range 0.122-1.330MeV

Radiological parameters such as μ{sub m}, σ{sub t}, σ{sub e}, Z{sub eff} and N{sub eff} of amino acids, namely Lysine (C{sub 6}H{sub 15}N{sub 2}O{sub 2}), Histidine (C{sub 6}H{sub 9}N{sub 3}O{sub 2}) and Arginine (C{sub 6}H{sub 15}N{sub 4}O{sub 2}), were measured using NaI (Tl)-based gamma spectrometry. Radioactive sources used in the study are {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 54}Mn, {sup 60}Co and {sup 22}Na. Gamma ray transmission method in a narrow beam good geometry set up was used in the study. The measured data were compared against XCOM-based data. The agreement is within 2%.

07 ISOTOPE AND RADIATION SOURCES↗

Study of some health physics parameters of bismuth-ground granulated blast furnace slag shielding concretes

The Bismuth-ground granulated blastfurnace slang (Bi-GGBFS) concrete samples were prepared. The weight percentage of different elements present in Bi-GGBFS Shielding concretewas evaluated by Energy Dispersive X-ray Microanalysis (EDX). The exposure rate and absorbed dose rate characteristics were calculated theoretically for radioactive sources namely {sup 241}Am and {sup 137}Cs. Our calculations reveal that the Bi-GGBFS concretes are effective in shielding material for gamma radiations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monte Carlo simulation of simultaneous radiation detection in the hybrid tomography system ClearPET-XPAD3/CT

Using the Geant4 based simulation framework SciFW1, a detailed simulation was performed for a detector array in the hybrid tomography prototype for small animals called ClearPET / XPAD, which was built in the Centre de Physique des Particules de Marseille. The detector system consists of an array of phoswich scintillation detectors: LSO (Lutetium Oxy-ortosilicate doped with cerium Lu{sub 2}SiO{sub 5}:Ce) and LuYAP (Lutetium Ortoaluminate of Yttrium doped with cerium Lu{sub 0.7}Y{sub 0.3}AlO{sub 3}:Ce) for Positron Emission Tomography (PET) and hybrid pixel detector XPAD for Computed Tomography (CT). Simultaneous acquisition of deposited energy and the corresponding time - position for each recorded event were analyzed, independently, for both detectors. interference between detection modules for PET and CT. Information about amount of radiation reaching each phoswich crystal and XPAD detector using a phantom in order to study the effectiveness by radiation attenuation and influence the positioning of the radioactive source {sup 22}Na was obtained. The simulation proposed will improve distribution of detectors rings and interference values will be taken into account in the new versions of detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Development and Experimental Validation of a Heat Transfer Model for Spilled Molten Salt Pools

A spill of radionuclide-bearing molten salt is one of the major postulated events that needs to be analyzed for liquid fluorine salt-cooled high-temperature reactor (FHR) or molten salt reactor licensing purposes. In this postulated event, radioactive source term materials (RSTMs) in the molten salt are discharged from the reactor vessel to the reactor building. The release of RSTMs from the spilled salt pool to the gas space in the reactor building is expected to be controlled by the cooling behavior of the spilled salt, including the growth and shrinkage of the solid crust on the surface of the spilled salt pool. This paper presents a simulation model for spilled salt pool heat transfer and validation efforts. The validation data come from two molten salt spill tests that were performed recently: the PELE2 test by the Rapid Experimental Laboratory of Kairos Power LLC (KP) and the Argonne salt cooling test conducted by Argonne National Laboratory. The former was a large-scale test involving kilograms of molten spilled FLiNaK salt, and the latter was a relatively smaller-scale test targeting various processes associated with a salt spill event. Both tests generated valuable data sets that can be used to assess salt cooling and validate evaluation models. This paper provides a new one-dimensional model that can simulate the cooling process of a spilled salt pool as well as the thermal responses of heat structures, such as the stainless steel liner and the concrete below the salt. The model has been implemented as part of KP-SAM code, which is a branch of the systems code SAM specific to KP FHR. In conclusion, the simulation results of the model are compared with the data of the PELE2 and Argonne tests, and reasonable agreements are observed between the model and test data.

heat transfer model↗

Cutaneous and local radiation injuries

The threat of a large-scale radiological or nuclear (R/N) incident looms in the present-day climate, as noted most recently in an editorial in Scientific American (March 2021). These large-scale incidents are infrequent but affect large numbers of people. Smaller-scale R/N incidents occur more often, affecting smaller numbers of people. There is more awareness of acute radiation syndrome (ARS) in the medical community; however, ionising radiation-induced injuries to the skin are much less understood. Here, this article will provide an overview of radiation-induced injuries to the skin, deeper tissues, and organs. The history and nomenclature; types and causes of injuries; pathophysiology; evaluation and diagnosis; current medical management; and current research of the evaluation and management are presented. Cutaneous radiation injuries (CRI) or local radiation injuries (LRI) may lead to cutaneous radiation syndrome, a sub-syndrome of ARS. These injuries may occur from exposure to radioactive particles suspended in the environment (air, soil, water) after a nuclear detonation or an improvised nuclear detonation (IND), a nuclear power plant incident, or an encounter with a radioactive dispersal or exposure device. These incidents may also result in a radiation-combined injury; a chemical, thermal, or traumatic injury, with radiation exposure. Skin injuries from medical diagnostic and therapeutic imaging, medical misadministration of nuclear medicine or radiotherapy, occupational exposures (including research) to radioactive sources are more common but are not the focus of this manuscript. Diagnosis and evaluation of injuries are based on the scenario, clinical picture, and dosimetry, and may be assisted through advanced imaging techniques. Research-based multidisciplinary therapies, both in the laboratory and clinical trial environments, hold promise for future medical management. Great progress is being made in recognising the extent of injuries, understanding their pathophysiology, as well as diagnosis and management; however, research gaps still exist.

61 RADIATION PROTECTION AND DOSIMETRY↗

Directional Neutron Detection and TPC Developments and LLNL

LLNL is involved with a number of TPC projects spanning basic science to homeland security. This talk outlines the TPC work at LLNL and specifically focuses on the neutron TPC. A number of TPC projects are now underway at Lawrence Livermore National Laboratory (LLNL) and there is currently a ramp up in the infrastructure both in equipment and people to support these efforts. In place are high pressure vessels for xenon studies up to 50bar, larger vessels up to 100 litters at 10bar, clean room facilities, extensive electronics development, dedicated lab space and a assortment of radioactive sources.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗