Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Structure in the COBE differential microwave radiometer first-year maps

Results of the first year of data from the differential microwave radiometers on the Cosmic Background Explorer are presented. Statistically significant structure that is well described as scale-invariant fluctuations with a Gaussian distribution is shown. The rms sky variation, smoothed to a total 10-deg FWHM Gaussian, is 30 +/-5 micro-K for Galactic latitude greater than 20-deg data with the dipole anisotropy removed. The rms cosmic quadrupole amplitude is 13 +/-4 micro-K. The angular autocorrelation of the signal in each radiometer channel and cross-correlation between channels are consistent and give a primordial fluctuation power-law spectrum with index of 1.1 +/-0.5, and an rms-quadrupole-normalized amplitude of 16 +/-4 micro-K. These features are in accord with the Harrison-Zel'dovich spectrum predicted by models of inflationary cosmology.

Smoot, G. F.↗

MMIC Receiver For Water-Vapor Radiometer

MMIC receiver puts out signal, frequency of which proportioned to brightness temperature of sky at input frequency of 31 GHz. Miniaturization enhances thermal stability and stability of calibration of water-vapor radiometer. Potential for mass production at relatively low cost. Facilitating widespread use of MMIC water vapor radiometers in meteorology and aviation, deployed at several global sites to improve capability of general circulation models and at airports to monitor icing conditions by measuring supercooled liquid water in clouds.

Sukamto, Lin M.↗

The Split Window Microwave Radiometer (SWMR) for hurricane wind speed measurement from space

The monitoring of hurricanes demands considerable resources each year by the National Oceanic and Atmospheric Administration. Even with the extensive use of satellite and airborne probing of those storms, there is still much uncertainty involved in predicting landfall for timely evacuation of people subject to the threat. The concept of the Split Window Microwave Radiometer (SWMR) is to add an additional capability of remotely measuring surface winds to hopefully improve prediction capabilities or at least define the severity of the storm while it is far from land. Some of the present science and observational needs are addressed in this report as are remote sensing limitations which impact the design of a minimal system which can be launched into low earth orbit by a low cost launch system. This study has concluded that wind speed and rain rate maps of hurricanes can be generated with an X-Band radiometer system with an antenna whose aperture is 2 m on a side.

Swift, Calvin T.↗

All-solid-state radiometers for environmental studies to 700 GHz

We report results with an all-solid-state radiometer for measurements of the ClO molecule at 649 GHz. The project is part of a program to provide low-noise, low-weight, low-power radiometers for space operation, and special effort has been expended on the development of high-efficiency solid-state frequency multipliers and Schottky-barrier mixers with low local oscillator power requirements. The best measured system noise temperature was 1750 K with the mixer and preamplifier cooled to 77 K. The mixer diode was easily pumped into saturation, indicating that the design has excellent prospects of operating at higher frequencies - our present design goal being 1 THz. We comment on the principal design features of such systems and will report on stratospheric measurements performed with this system.

Zimmermann, Ralph↗

ESTAR: The Electronically Scanned Thinned Array Radiometer for remote sensing measurement of soil moisture and ocean salinity

The product of a working group assembled to help define the science objectives and measurement requirements of a spaceborne L-band microwave radiometer devoted to remote sensing of surface soil moisture and sea surface salinity is presented. Remote sensing in this long-wavelength portion of the microwave spectrum requires large antennas in low-Earth orbit to achieve acceptable spatial resolution. The proposed radiometer, ESTAR, is unique in that it employs aperture synthesis to reduce the antenna area requirements for a space system.

Swift, C. T.↗

A ratioing radiometer for use with a solar diffuser

The use of an on-board solar diffuser has been proposed to monitor the in-flight calibration of satellite sensors. This paper presents the preliminary specifications and design for a ratioing radiometer, to be used to determine the change in radiance of the solar diffuser. The issues involved in spectral channel selection are discussed and the effects of stray light are presented. An error analysis showing the benefit of the ratioing radiometer is included.

Palmer, James M.↗

Spatial sampling errors for a satellite-borne scanning radiometer

The Clouds and Earth's Radiant Energy System (CERES) scanning radiometer is planned as the Earth radiation budget instrument for the Earth Observation System, to be flown in the late 1990's. In order to minimize the spatial sampling errors of the measurements, it is necessary to select design parameters for the instrument such that the resulting point spread function will minimize spatial sampling errors. These errors are described as aliasing and blurring errors. Aliasing errors are due to presence in the measurements of spatial frequencies beyond the Nyquist frequency, and blurring errors are due to attenuation of frequencies below the Nyquist frequency. The design parameters include pixel shape and dimensions, sampling rate, scan period, and time constants of the measurements. For a satellite-borne scanning radiometer, the pixel footprint grows quickly at large nadir angles. The aliasing errors thus decrease with increasing scan angle, but the blurring errors grow quickly. The best design minimizes the sum of these two errors over a range of scan angles. Results of a parameter study are presented, showing effects of data rates, pixel dimensions, spacecraft altitude, and distance from the spacecraft track.

Manalo, Natividad D.↗

Scanning mirror design considerations for a geostationary spaceborne radiometer

This paper will address the design considerations and challenges for a radiometer scanning mirror in a Geostationary (GEO) orbit. With increasingly demanding imaging requirements, mirror designs that are insensitive to the harsh thermal environment will be required. The compatibility of various mirror designs for a precision radiometer will be examined and discussed. The design solutions considered will include material, geometry and thermal design tradeoffs.

Hookman, R. A.↗

ESTAR - A synthetic aperture microwave radiometer for measuring soil moisture

The measurement of soil moisture from space requires putting relatively large microwave antennas in orbit. Aperture synthesis, an interferometric technique for reducing the antenna aperture needed in space, offers the potential for a practical means of meeting these requirements. An aircraft prototype, electronically steered thinned array L-band radiometer (ESTAR), has been built to develop this concept and to demonstrate its suitability for the measurement of soil moisture. Recent flights over the Walnut Gulch Watershed in Arizona show good agreement with ground truth and with measurements with the Pushbroom Microwave Radiometer (PBMR).

Le Vine, D. M.↗

Millimeter-wave imaging radiometer for cloud, precipitation and atmospheric water vapor studies

A millimeter-wave imaging radiometer (MIR) developed by NASA Goddard Space Flight Center is described. The MIR is a nine-channel total power radiometer developed for atmospheric research. Three dual-pass band channels are centered about the strongly opaque 183-GHz water vapor absorption line; the frequencies are 183 +/- 1, +/- 3, and +/- 7 GHz. Another channel is located on the wing of this band at 150 GHz. These four channels have varying degrees of opacity from which the water vapor profile can be inferred. The design and salient characteristics of this instrument are discussed, together with its expected benefits.

Racette, P. E.↗

Multiparameter radar and advanced microwave precipitation radiometer observations of tropical convection

Combinations of both active and passive microwave sensors have been proposed for experiments such as the tropical rainfall measuring mission (TRMM). During the summer 1991 Convection and Precipitation/Electrification Experiment (CaPE) in central Florida, both cold- and warm-rain precipitation processes were studied with the NCAR CP-2 multiparameter radar, operating at 3 and 10 GHz. The Advanced Microwave Precipitation Radiometer (AMPR), which operates at 10.7, 19.35, 37.1, and 85.5 GHz, was flown aboard NASA's ER-2 high-altitude aircraft over storms being scanned by the CP-2 radar. Top-of-atmosphere multifrequency TB from the AMPR is presented along with coincident CP-2 radar observations. Joint analysis of both radar and radiometer data sets allows refinement of new and existing precipitation retrieval techniques which will utilize the multifrequency TB from an integrated spaceborne microwave radiometer/radar system.

Vivekanandan, J.↗

Spatial spectra from a satellite scanning radiometer

A method for computing spatial spectra from measurement based on a scanning radiometer is presented which takes into account the instrument field-of-view, time response, and the scan pattern. To compute the mean of the field, measurements away from nadir are weighted more heavily than those near nadir. The proposed method is capable of defining the limits beyond which the Fourier components cannot be extracted from the data. Results show that, for the Earth Radiation Budget Experiment scanning radiometer at an altitude of 600 km, spectral features with wavelengths greater than 100 km can be measured without errors due to incorporation of unobservable portions of the spectrum into results.

Smith, G. L.↗

Phase aligner for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Phase Aligner (PA) or the Electronically Scanned Thinned Array Radiometer instrument has been designed and tested. Implemented in a single Xilinx XC3042PC84-125 Field Programmable Gate Array (FPGA), it is a dual-port register file which allows independent storage and phase coherent retrieval of antenna array data by the Central Processing Unit (CPU). It has dimensions of 4 x 20 bits and can be used at clock frequencies as high as 25 MHz. The ESTAR is a passive synthetic-aperture radiometer designed to sense soil moisture and ocean salinity at L-band.

Chren, William A., Jr.↗

Calibration of a helium-cooled infrared spatial radiometer and grating spectrometer

Methods used by the Space Dynamics Laboratory of Utah State University (SDL/USU) to calibrate infrared sensors are described, using the Infrared Background Signature Survey (IBSS) spatial radiometer and grating spectrometer as examples. A calibration equation and a radiometric model are given for each sensor to describe their responsivity in terms of individual radiometric parameters. The calibration equation terms include dark offset, linearity, absolute responsivity, and measurement uncertainty, and the radiometric model domains include spatial, spectral, and temporal domains. A portable calibration facility, designed and fabricated by SDL/USU, provided collimated, extended, diffuse scatter, and Jones sources in a single cryogenic dewar. This multi-function calibrator allowed calibration personnel to complete a full calibration of the IBSS infrared radiometer and spectrometer in two 15-day periods. A calibration data system was developed to control and monitor the calibration facility, and to record and analyze sensor data.

Jacobsen, Larry↗

Science objectives and performance of a radiometer and window design for atmospheric entry experiments

The Radiative Heating Experiment, RHE, aboard the Aeroassist Flight Experiment, AFE, (now cancelled) was to make in-situ measurements of the stagnation region shock layer radiation during an aerobraking maneuver from geosynchronous to low earth orbit. The measurements were to provide a data base to help develop and validate aerothermodynamic computational models. Although cancelled, much work was done to develop the science requirements and to successfully meet RHE technical challenges. This paper discusses the RHE scientific objectives and expected science performance of a small sapphire window for the RHE radiometers. The spectral range required was from 170 to 900 nm. The window size was based on radiometer sensitivity requirements including capability of on-orbit solar calibration.

Craig, Roger A.↗

Large area mapping of soil moisture using the ESTAR passive microwave radiometer

Investigations designed to study land surface hydrologic-atmospheric interactions, showing the potential of L band passive microwave radiometry for measuring surface soil moisture over large areas, are discussed. Satisfying the data needs of these investigations requires the ability to map large areas rapidly. With aircraft systems this means a need for more beam positions over a wider swath on each flightline. For satellite systems the essential problem is resolution. Both of these needs are currently being addressed through the development and verification of Electronically Scanned Thinned Array Radiometer (ESTAR) technology. The ESTAR L band radiometer was evaluated for soil moisture mapping applications in two studies. The first was conducted over the semiarid rangeland Walnut Gulch watershed located in south eastern Arizona (U.S.). The second was performed in the subhumid Little Washita watershed in south west Oklahoma (U.S.). Both tests showed that the ESTAR is capable of providing soil moisture with the same level of accuracy as existing systems.

Jackson, T. J.↗

A conceptual thermal design study of an electronically scanned thinned array radiometer

This report describes conceptual thermal design study for an Electronically Scanned Thinned Array Radiometer (ESTAR). ESTAR is an instrument concept for the measurement of soil moisture from space using synthetic aperture radiometry. The thermal design goal is to minimize the orbital temperature variation of the radiometer receivers using established materials and techniques. Two design approaches have been investigated; the first uses the waveguide as a heat sink, and the second uses a nadir facing radiator on the receiver assembly. The second approach minimizes the receiver's impact on the waveguide temperatures. Predicted temperatures for all receivers are presented for the two cases indicating the transient thermal environments the receivers would experience during an orbit. In addition, the effects of the receiver heat dissipation on the waveguide temperatures are shown.

Gould, D. C.↗

TOPEX/POSEIDON microwave radiometer performance and in-flight calibration

Results of the in-flight calibration and performance evaluation campaign for the TOPEX/POSEIDON microwave radiometer (TMR) are presented. Intercomparisons are made between TMR and various sources of ground truth, including ground-based microwave water vapor radiometers, radiosondes, global climatological models, special sensor microwave imager data over the Amazon rain forest, and models of clear, calm, subpolar ocean regions. After correction for preflight errors in the processing of thermal/vacuum data, relative channel offsets in the open ocean TMR brightness temperatures were noted at the approximately = 1 K level for the three TMR frequencies. Larger absolute offsets of 6-9 K over the rain forest indicated a approximately = 5% gain error in the three channel calibrations. This was corrected by adjusting the antenna pattern correction (APC) algorithm. AS 10% scale error in the TMR path delay estimates, relative to coincident radiosondes, was corrected in part by the APC adjustment and in part by a 5% modification to the value assumed for the 22.235 FGHz water vapor line strength in the path delay retrieval algorithm. After all in-flight corrections to the calibration, TMR global retrieval accuracy for the wet tropospheric range correction is estimated at 1.1 cm root mean square (RMS) with consistent peformance under clear, cloudy, and windy conditions.

Ruf, C. S.↗