Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reduced models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Reduced order modeling of a fluidized bed particle receiver for concentrating solar power with thermal energy storage

Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.

14 SOLAR ENERGY↗

Late day measurement of excised branches results in uncertainty in the estimation of two stomatal parameters derived from response curves in Populus deltoides Bartr. x Populus nigra L.

Many terrestrial biosphere models depend on an understanding of the relationship between stomatal conductance and photosynthesis. However, unlike the measurement of photosynthetic parameters, such as the maximum carboxylation capacity, where standard methods (e.g., CO 2 response or ACi curves) are widely accepted, a consensus method for empirically measuring parameters representing stomatal response has not yet emerged. Most models of stomatal response to environment represent stomatal conductance as being bounded by a lower intercept parameter (g 0 ), and linearly scaled based on a multivariate term described by the stomatal slope parameter (g 1 ). Here we employ the widely used Unified Stomatal Optimization model, to test whether g 1 and g 0 parameters are impacted by the choice of measurement method, either on an intact branch, or a cut branch segment stored in water. We measured paired stomatal response curves on intact and excised branches of a hybrid poplar clone (Populus deltoides Bartr. x Populus nigra L. OP367), measured twice over a diurnal period. We found that predawn branch excision did not significantly affect measured g 0 and g 1 when measured within 4 h of excision. Measurement in the afternoon resulted in significantly higher values of g 1 and lower values of g0, with values changing by 55% and 56% respectively. Excision combined with afternoon measurement resulted in a marked effect on parameter estimates, with g1 increasing 89% from morning to afternoon and a 25% lower g 1 for cut branches than those measured in situ. We also show that in hybrid poplar the differences in parameter estimates obtained from plants measured under different conditions can directly impact models of canopy function, reducing modeled transpiration by 18% over a simulated 12.5-hour period. While these findings are only for a single isohydric woody species, our findings suggest that stomatal optimality parameters may not remain constant throughout the day.

54 ENVIRONMENTAL SCIENCES↗

User’s Manual for Seal_Flux: A Seal Barrier Reduced-Order Model

This report provides a brief description on the use of the Seal_Flux computer program developed as part of the effort to quantify the risk of geologic storage of carbon dioxide (CO 2 ) under the U.S. Department of Energy’s (DOE) National Risk Assessment Partnership (NRAP). The Seal_Flux code simulates the flow of CO 2 through a low permeability rock horizon or seal formation overlying the storage reservoir into which CO 2 is injected. A two-phase, relative permeability approach with Darcy’s law is used for one-dimensional (1D) flow computations of CO 2 through the horizon in the vertical direction. The code also allows the simulation of time-dependent processes that can influence such flow.

54 ENVIRONMENTAL SCIENCES↗