Search NASA⌕ Search

SEARCH · Search NASA

Results for “References”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Validation of galvanomagnetic and thermomagnetic transport measurements using Standard Reference Material 3451

In the “method of four coefficients,” electrical resistivity (ρ), Seebeck coefficient (S), Hall coefficient (RH), and Nernst coefficient (Q) of a material are measured and typically fit or modeled with theoretical expressions based on Boltzmann transport theory to glean experimental insights into features of electronic structure and/or charge carrier scattering mechanisms in materials. Although well-defined and readily available reference materials exist for validating measurements of ρ and S, none currently exists for R H or Q. We show that measurements of all four transport coefficients—ρ, S, R H , and Q—can be validated using a single reference sample, namely, the low-temperature Seebeck coefficient Standard Reference Material® (SRM) 3451 (composition Bi 2 Te 3+x ) available from the National Institute for Standards and Technology (NIST) without the need for inter-laboratory sample exchange. Here, R H and Q data for NIST SRM 3451 reported here for the temperature range 80–400 K complement the data already available for ρ and S and will therefore be of interest to researchers desiring to validate new or existing galvanomagnetic and thermomagnetic transport properties measurement systems.

47 OTHER INSTRUMENTATION↗

Optical frequency reference for the national time scale

Incorporation of a strontium optical clock as an optical frequency reference into the primary standard GET 1-2018 is experimentally implemented. A new model is proposed to define a local atomic time scale using an optical reference incorporated into a complex for reproducing primary standard units. Preliminary results of comparing the frequencies of the optical reference and the hydrogen maser entering the composition of primary time and frequency standards are presented. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methane microwave optical master oscillator for fountain references

We have demonstrated a microwave master oscillator operating on optical principles and based on a He – Ne/CH{sub 4} optical frequency standard (λ = 3.39 μm) and femtosecond fibre laser system ( λ = 1.54 μm). The output signal spectrum of the oscillator has the form of an equidistant frequency comb in the range 60 MHz to 10 GHz with a 60-MHz step. Comparison of the frequencies of two master oscillators shows that the short-term output frequency instability for the comb components in the range 0.8 – 1.5 GHz is under 1 × 10{sup −14} at an averaging time of 1 s. We have tested microwave signals from the oscillator using apparatus in the reference facility at the State Time and Frequency Service, All-Russia Research Institute of Physical and Radio Engineering Measurements. A signal at a nominal frequency of 100 MHz synthesised from one comb component was compared to signals from two hydrogen masers with enhanced short-term stability in the reference facility. The short-term frequency stability of the synthesised signal has been shown to be twice better than the stability of the masers and to be limited by the intrinsic instability of the commercial synthesiser of a 100-MHz nominal frequency. Our experiments confirm that the proposed microwave optical master oscillator is potentially attractive for use in systems with increased requirements for short-term frequency stability, in particular in time and frequency fountain references. (optical frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

OPTICAL SPECTRA OF CANDIDATE INTERNATIONAL CELESTIAL REFERENCE FRAME (ICRF) FLAT-SPECTRUM RADIO SOURCES

Continuing our program of spectroscopic observations of International Celestial Reference Frame (ICRF) sources, we present redshifts for 120 quasars and radio galaxies. Data were obtained with five telescopes: the 3.58 m European Southern Observatory New Technology Telescope, the two 8.2 m Gemini telescopes, the 2.5 m Nordic Optical Telescope (NOT), and the 6.0 m Big Azimuthal Telescope of the Special Astrophysical Observatory in Russia. The targets were selected from the International VLBI Service for Geodesy and Astrometry candidate International Celestial Reference Catalog which forms part of an observational very long baseline interferometry (VLBI) program to strengthen the celestial reference frame. We obtained spectra of the potential optical counterparts of more than 150 compact flat-spectrum radio sources, and measured redshifts of 120 emission-line objects, together with 19 BL Lac objects. These identifications add significantly to the precise radio-optical frame tie to be undertaken by Gaia, due to be launched in 2013, and to the existing data available for analyzing source proper motions over the celestial sphere. We show that the distribution of redshifts for ICRF sources is consistent with the much larger sample drawn from Faint Images of the Radio Sky at Twenty cm (FIRST) and Sloan Digital Sky Survey, implying that the ultra-compact VLBI sources are not distinguished from the overall radio-loud quasar population. In addition, we obtained NOT spectra for five radio sources from the FIRST and NRAO VLA Sky Survey catalogs, selected on the basis of their red colors, which yielded three quasars with z > 4.

79 ASTRONOMY AND ASTROPHYSICS↗

The Gaia inertial reference frame and the tilting of the Milky Way disk

While the precise relationship between the Milky Way disk and the symmetry planes of the dark matter halo remains somewhat uncertain, a time-varying disk orientation with respect to an inertial reference frame seems probable. Hierarchical structure formation models predict that the dark matter halo is triaxial and tumbles with a characteristic rate of ∼2 rad H{sub 0}{sup −1} (∼30 μas yr{sup –1}). These models also predict a time-dependent accretion of gas, such that the angular momentum vector of the disk should be misaligned with that of the halo. These effects, as well as tidal effects of the LMC, will result in the rotation of the angular momentum vector of the disk population with respect to the quasar reference frame. We assess the accuracy with which the positions and proper motions from Gaia can be referred to a kinematically non-rotating system, and show that the spin vector of the transformation from any rigid self-consistent catalog frame to the quasi-inertial system defined by quasars should be defined to better than 1 μas yr{sup –1}. Determination of this inertial frame by Gaia will reveal any signature of the disk orientation varying with time, improve models of the potential and dynamics of the Milky Way, test theories of gravity, and provide new insights into the orbital evolution of the Sagittarius dwarf galaxy and the Magellanic Clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

Holographic phase retrieval and reference design

Here, a general mathematical framework and recovery algorithm is introduced for the holographic phase retrieval problem. In this problem, which arises in holographic coherent diffraction imaging, a 'reference' portion of the signal to be recovered via phase retrieval is a priori known from experimental design. A generic formula is additionally derived for the expected recovery error when the measurement data is corrupted by Poisson shot noise. This facilitates an optimization perspective towards reference design and analysis. We employ this optimization perspective towards quantifying the performance of various reference choices.

97 MATHEMATICS AND COMPUTING↗

Reference-free structural variant detection in microbiomes via long-read co-assembly graphs

Motivation: The study of bacterial genome dynamics is vital for understanding the mechanisms underlying microbial adaptation, growth, and their impact on host phenotype. Structural variants (SVs), genomic alterations of 50 base pairs or more, play a pivotal role in driving evolutionary processes and maintaining genomic heterogeneity within bacterial populations. While SV detection in isolate genomes is relatively straightforward, metagenomes present broader challenges due to the absence of clear reference genomes and the presence of mixed strains. In response, our proposed method rhea, forgoes reference genomes and metagenome-assembled genomes (MAGs) by encompassing all metagenomic samples in a series (time or other metric) into a single co-assembly graph. The log fold change in graph coverage between successive samples is then calculated to call SVs that are thriving or declining. Results: We show rhea to outperform existing methods for SV and horizontal gene transfer (HGT) detection in two simulated mock metagenomes, particularly as the simulated reads diverge from reference genomes and an increase in strain diversity is incorporated. We additionally demonstrate use cases for rhea on series metagenomic data of environmental and fermented food microbiomes to detect specific sequence alterations between successive time and temperature samples, suggesting host advantage. Our approach leverages previous work in assembly graph structural and coverage patterns to provide versatility in studying SVs across diverse and poorly characterized microbial communities for more comprehensive insights into microbial gene flux.

59 BASIC BIOLOGICAL SCIENCES↗

A haplotype-resolved reference genome for Eucalyptus grandis

Eucalyptus grandis is a hardwood tree used worldwide as pure species or hybrid partner to breed fast-growing plantation forestry crops that serve as feedstocks of timber and lignocellulosic biomass for pulp, paper, biomaterials, and biorefinery products. The current v2.0 genome reference for the species served as the first reference for the genus and has helped drive the development of molecular breeding tools for eucalypts. Using PacBio HiFi long reads and Omni-C proximity ligation sequencing, we produced an improved, haplotype-phased assembly (v4.0) for TAG0014, an early-generation selection of E. grandis. The 2 haplotypes are 571 Mbp (HAP1) and 552 Mbp (HAP2) in size and consist of 37 and 46 contigs scaffolded onto 11 chromosomes (contig N50 of 28.9 and 16.7 Mbp), respectively. These haplotype assemblies are 70-90 Mbp smaller than the diploid v2.0 assembly but capture all except one of the 22 telomeres, suggesting that substantial redundant sequence was included in the previous assembly. A total of 35,929 (HAP1) and 35,583 (HAP2) gene models were annotated, of which 438 and 472 contain long introns (>10 kbp) in gene models previously (v2.0) identified as multiple smaller genes. These and other improvements have increased gene annotation completeness levels from 93.8 to 99.4% in the v4.0 assembly. We found that 6,493 and 6,346 genes are within tandem duplicate arrays (HAP1 and HAP2, respectively, 18.4 and 17.8% of the total) and >43.8% of the haplotype assemblies consists of repeat elements. Analysis of synteny between the haplotypes and the E. grandis v2.0 reference genome revealed extensive regions of collinearity, but also some major rearrangements, and provided a preview of population and pangenome variation in the species.

Lötter, Anneri↗

The Planteome database: an integrated resource for reference ontologies, plant genomics and phenomics

The Planteome project (http://www.planteome.org) provides a suite of reference and species-specific ontologies for plants and annotations to genes and phenotypes. Ontologies serve as common standards for semantic integration of a large and growing corpus of plant genomics, phenomics and genetics data. The reference ontologies include the Plant Ontology, Plant Trait Ontology and the Plant Experimental Conditions Ontology developed by the Planteome project, along with the Gene Ontology, Chemical Entities of Biological Interest, Phenotype and Attribute Ontology, and others. The project also provides access to species-specific Crop Ontologies developed by various plant breeding and research communities from around the world. We provide integrated data on plant traits, phenotypes, and gene function and expression from 95 plant taxa, annotated with reference ontology terms. The Planteome project is developing a plant gene annotation platform; Planteome Noctua, to facilitate community engagement. All the Planteome ontologies are publicly available and are maintained at the Planteome GitHub site (https://github.com/Planteome) for sharing, tracking revisions and new requests. The annotated data are freely accessible from the ontology browser (http://browser.planteome.org/amigo) and our data repository.

Biochemistry & Molecular Biology↗

Natural reference for nuclear high-spin states

We suggest two new representations of the data on rotational nuclei. The first is reference-free and the second arises from a natural reference related to the variable moment of inertia model parameters of the ground-state band of the system. As such, neither representation contains any free parameters. By defining a 'configuration spin' we show how a new ground-state band reference can be applied. Its use allows a complete description of the changes associated with the first, and higher, band crossings. We apply these new representations to discuss the nature of the first band crossing along even-even isotopic chains in the erbium and osmium isotopes and to odd-even nuclei in the vicinity of {sup 158}Er.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

An Adaptive Reference Scheme to Extend the Functional Range of Optical Backscatter Reflectometry in Extreme Environments

Optical frequency domain reflectometry (OFDR) measurements are performed by recording the interference pattern of light backscattered by density fluctuations or Bragg gratings along the length of an optical fiber. Changes in local temperature or strain in the fiber cause shifts in the backscattered light spectrum, which can be calibrated to the applied temperature or strain. Comparing the backscattered optical spectra from each reflection site with a reference (unstrained) spectrum allows for quantification of local spectral shifts. While mature OFDR-based technologies can provide high-precision spatially distributed measurements over kilometer lengths, the post-processing approaches used to recover spectral shifts from raw optical intensity data can limit the use of OFDR in harsh environments. This paper presents a novel approach to post-processing OFDR data which extends the usability of optical fibers exposed to harsh environments. This approach is the first to use the spectral shift quality, calculated for two OFDR measurements, to identify an appropriate reference scan from which the spectral shift can be determined. Here, three experimental data sets are used to test the algorithm: (1) an optical fiber heated to >950°C, (2) an aluminum-embedded optical fiber under strain from differential thermal expansion, and (3) an optical fiber exposed to a total neutron flux of 2×10 13 n/cm 2 /s over 40 hours in a nuclear test reactor. Results show that using a metric of quality to select an appropriate reference measurement extends the functional range of OFDR strain and temperature sensors. Furthermore, this algorithm can be applied to existing OFDR data.

47 OTHER INSTRUMENTATION↗

Sequence Impedance Measurement of Utility-Scale Wind Turbines and Inverters – Reference Frame, Frequency Coupling, and MIMO/SISO Forms

Sequence impedance responses with or without considering frequency coupling in both MIMO and SISO forms are increasingly used for the stability analysis of three-phase power electronic systems; however, many aspects of sequence impedance measurement are not fully explored. It is not clear if the sequence impedance has a reference frame similar to the dq impedance. If so, the role of the grid voltage angle estimation in aligning the sequence impedance reference frame has not been discussed. Additionally, existing methods for measuring the sequence impedance with frequency coupling are complicated, are not feasible for large wind turbines and inverters, and provide the sequence impedance responses in only either MIMO or SISO form. This paper presents a sequence impedance measurement method that considers the frequency coupling, performs reference frame alignment, demonstrates the impact of the grid voltage angle estimation, and obtains the sequence impedance response in both MIMO and SISO forms. This paper demonstrates the proposed method and practical problems associated with the sequence impedance measurement of utility-scale wind turbines and inverters on a 1.9-MW Type III wind turbine and a 2.2-MVA inverter using an impedance measurement system built around a 7-MW/13.8-kV grid simulator and a 5-MW dynamometer.

17 WIND ENERGY↗

A Wide Temperature, Radiation Tolerant, CMOS-compatible Precision Voltage Reference for Extreme Environment Instrumentation Systems

Many design techniques have been incorporated into modern CMOS design practices to improve radiation tolerance of integrated circuits. Annular-gate NMOS structures have been proven to be significantly more radiation tolerant than the standard straight-gate variety. Many circuits can be designed using the annular-gate NMOS and the inherently radiation tolerant PMOS. Band-gap reference circuits, however, typically require p-n junction diodes. These p-n junction diodes are the dominating factor in radiation degradation in band-gap reference circuits. This paper proposes a different approach to band-gap reference design to alleviate the radiation susceptibility presented by the p-n junction diodes.

radiation hardened by design↗

Definition of System Angle Reference for Distribution Level Synchronized Angle Measurement Applications

Distribution phasor measurement units (DPMUs) provide power grid operators unprecedented system monitoring opportunities with local-area, synchronized, low latency, and high-resolution measurements. All raw angle measurements in DPMUs need a common angle reference for comparison since the phase is likely to be shifted by transformers in distribution network. To obtain a robust reference under conditions of data loss or local oscillation, this letter proposes a definition of system angle reference for DPMU. The effectiveness of this system angle is confirmed via real measurement data collected by DPMUs.

42 ENGINEERING↗

Phase Locking of a THz QC-VECSEL to a Microwave Reference

We report high-resolution frequency study and phase locking have been performed on a terahertz (THz) quantum-cascade vertical-external-cavity surface-emitting laser (QC-VECSEL) operating around 2.5 THz. A subharmonic diode mixer is used to down convert the THz signal to a 100 MHz intermediate frequency that is phase locked to a stable 100 MHz microwave reference. Between 90% and 95% of the QC-VECSEL signal is locked within 2 Hz of the multiplied RF reference, and amplitude fluctuations on the order of 1%–10% are observed, depending on the bias point of the QC-VECSEL. The bandwidth of the locking loop is ~1 MHz. Many noise peaks in the IF signal are observed, likely corresponding to mechanical resonances in the 10 Hz–10 kHz. These peaks are generally -30 to -60 dB below the main tone and are below the phase noise level of the multiplied RF reference that ultimately limits the phase noise of the locked QC-VECSEL.

42 ENGINEERING↗

A cell wall reference profile for Miscanthus bioenergy crops highlights compositional and structural variations associated with development and organ origin

Summary Miscanthus spp. are promising lignocellulosic energy crops, but cell wall recalcitrance to deconstruction still hinders their widespread use as bioenergy and biomaterial feedstocks. Identification of cell wall characteristics desirable for biorefining applications is crucial for lignocellulosic biomass improvement. However, the task of scoring biomass quality is often complicated by the lack of a reference for a given feedstock. A multidimensional cell wall analysis was performed to generate a reference profile for leaf and stem biomass from several miscanthus genotypes harvested at three developmentally distinct time points. A comprehensive suite of 155 monoclonal antibodies was used to monitor changes in distribution, structure and extractability of noncellulosic cell wall matrix glycans. Glycan microarrays complemented with immunohistochemistry elucidated the nature of compositional variation, and in situ distribution of carbohydrate epitopes. Key observations demonstrated that there are crucial differences in miscanthus cell wall glycomes, which may impact biomass amenability to deconstruction. For the first time, variations in miscanthus cell wall glycan components were comprehensively characterized across different harvests, organs and genotypes, to generate a representative reference profile for miscanthus cell wall biomass. Ultimately, this portrait of the miscanthus cell wall will help to steer breeding and genetic engineering strategies for the development of superior energy crops.

Plant Sciences↗

Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations

Purpose: To develop a computed tomography (CT) organ dose estimation method designed to readily provide organ doses in a reference adult male and female for different scan ranges to investigate the degree to which existing commercial programs can reasonably match organ doses defined in these more anatomically realistic adult hybrid phantomsMethods: The x-ray fan beam in the SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code MCNPX2.6. The simulated CT scanner model was validated through comparison with experimentally measured lateral free-in-air dose profiles and computed tomography dose index (CTDI) values. The reference adult male and female hybrid phantoms were coupled with the established CT scanner model following arm removal to simulate clinical head and other body region scans. A set of organ dose matrices were calculated for a series of consecutive axial scans ranging from the top of the head to the bottom of the phantoms with a beam thickness of 10 mm and the tube potentials of 80, 100, and 120 kVp. The organ doses for head, chest, and abdomen/pelvis examinations were calculated based on the organ dose matrices and compared to those obtained from two commercial programs, CT-EXPO and CTDOSIMETRY. Organ dose calculations were repeated for an adult stylized phantom by using the same simulation method used for the adult hybrid phantom. Results: Comparisons of both lateral free-in-air dose profiles and CTDI values through experimental measurement with the Monte Carlo simulations showed good agreement to within 9%. Organ doses for head, chest, and abdomen/pelvis scans reported in the commercial programs exceeded those from the Monte Carlo calculations in both the hybrid and stylized phantoms in this study, sometimes by orders of magnitude. Conclusions: The organ dose estimation method and dose matrices established in this study readily provides organ doses for a reference adult male and female for different CT scan ranges and technical parameters. Organ doses from existing commercial programs do not reasonably match organ doses calculated for the hybrid phantoms due to differences in phantom anatomy, as well as differences in organ dose scaling parameters. The organ dose matrices developed in this study will be extended to cover different technical parameters, CT scanner models, and various age groups.

61 RADIATION PROTECTION AND DOSIMETRY↗