Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

On the sources of ultraviolet absorption in spectra of Titan and the outer planets

In response to observations of the ultraviolet deficiencies shown by all of the outer planets and Titan, models have been proposed to explain the low albedos in terms of absorption by particles in the upper atmospheres of these objects. These particles are generally believed to be photochemically formed from gases in the upper atmospheres, primarily methane and hydrogen. Such processes may also be operative on Titan. Results of some laboratory experiments on proton irradiation of mixtures of gases including CH4, H2, and NH3 have shown that liquid and solid materials are produced that are strong ultraviolet absorbers. However, the material produced from the CH4 + H2 mixture was colorless, indicating that species containing elements other than carbon and hydrogen are necessary for the production of color. Two such elements are nitrogen (as NH3 or N2) and sulfur (as H2S); colored materials have been produced from such mixtures. None of these materials has spectral properties identical to those shown by the planets. Therefore it is necessary that mixtures (and/or cloud layers) of the photochemical materials be present.

Scattergood, T.↗

ANALYTICAL NEUTRONIC STUDIES CORRELATING FAST NEUTRON FLUENCE TO MATERIAL DAMAGE IN CARBON, SILICON, AND SILICON CARBIDE

This study evaluates how fast neutron fluence >0.1 MeV correlates to material damage (i.e., the total fluence spectrum folded with the respective material’s displacements-per- atom [dpa] damage response function) for the specific material fluence spectra encountered in Next Generation Nuclear Plant (NGNP) service and the irradiation tests conducted in material test reactors (MTRs) for the fuel materials addressed in the white paper. It also reports how the evaluated correlations of >0.1 MeV fluence to material damage vary between the different spectral conditions encountered in material service versus testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding reconstructed Dante spectra using high resolution spectroscopy

The Dante is an 18 channel filtered diode array used at the National Ignition Facility (NIF) to measure the spectrally and temporally resolved radiation flux between 50 eV and 20 keV from various targets. The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and a reconstruction algorithm applied to the recorded voltages from each channel. The reconstructed spectra are very low resolution with features consistent with the instrument response and are not necessarily consistent with the spectral emission features from the plasma. Errors may exist between the reconstructed spectra and the actual emission features due to assumptions in the algorithm. Recently, a high resolution convex crystal spectrometer, VIRGIL, has been installed at NIF with the same line of sight as the Dante. Spectra from L-shell Ag and Xe have been recorded by both VIRGIL and Dante. Comparisons of these two spectroscopic measurements yield insights into the accuracy of the Dante reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response function of a tunable diode laser spectrometer from an iterative deconvolution procedure

A deconvolution procedure commonly used for resolution enhancement of spectra has been applied to the determination of the response function of a tunable diode laser spectrometer. The method is sufficiently fast and simple for routine application when correcting for nonnegligible instrumental broadening. Absolute linestrengths of CH4 in the 1327/cm region and line positions of HNO3 in the 1335/cm region, measured with the aid of the deconvolution technique, are reported here.

May, Randy D.↗

Quasi-Elastic Neutron Scattering Studies of the Slow Dynamics of Supercooled and Glassy Aspirin

Aspirin, also known as acetylsalicylic acid (ASA), is not only a wonderful drug, but also a good glass former. Therefore, it serves as an important molecular system to study the near-arrest and arrested phenomena. In this paper, a high-resolution quasi-elastic neutron scattering (QENS) technique is used to investigate the slow dynamics of supercooled liquid and glassy aspirin from 410 K down to 350 K. The measured QENS spectra can be analyzed with a stretched exponential model. We find that (i) the stretched exponent (Q) is independent of the wave vector transfer Q in the measured Q-range, and (ii) the structural relaxation time (Q) follows a power law dependence on Q. Consequently, the Q-independent structural relaxation time 0 can be extracted for each temperature to characterize the slow dynamics of aspirin. The temperature dependence of 0 can be fitted with the mode coupling power law, the Vogel-Fulcher-Tammann equation and a universal equation for fragile glass forming liquids recently proposed by M. Tokuyama in the measured temperature range. The calculated dynamic response function T(Q,t) using the experimentally determined self-intermediate scattering function of the hydrogen atoms of aspirin shows a direct evidence of the enhanced dynamic fluctuations as the aspirin is increasingly supercooled, in agreement with the fixed-time mean squared displacement x2 and non-Gaussian parameter 2 extracted from the elastic scattering.

08 HYDROGEN↗

Investigations of Cadmium Manganese Telluride Crystals for Room-temperature Radiation Detection

Cadmium manganese telluride (CMT) has high potential as a material for room-temperature nuclear-radiation detectors. We investigated indium-doped CMT crystals taken from the stable growth region of the ingot and compared its characteristics with that from the last-to-freeze region. We employed different techniques, including synchrotron white-beam x-ray topography (SWBXT), current-voltage (I-V) measurement, and low-temperature photoluminescence spectra, and we also assessed their responses as detectors of radiation exposure. The crystal from the stable growth region proved to be superior to that from the last-to-freeze region; it is a single-grain crystal, free of twins, and displayed a resistivity higher by one order of magnitude. The segregation of indium dopant in the ingot might be responsible for its better resistivity. Furthermore, we recorded a good response in the detector fabricated from the crystal taken from the stable growth region; its ({mu}{tau})e value was 2.6 x 10{sup -3} cm{sup 2}/V, which is acceptable for thin detectors, including their application in medicine.

36 MATERIALS SCIENCE↗

Response of panels to turbulence-induced, surface-pressure fluctuations and resulting acoustic radiation to the flow field.

The response of finite rectangular panels, excited by turbulent boundary layers and the resulting acoustical radiation into the flow field is studied. The method of normal modes and the technique of spectral analysis are used to compute the power spectra of the panel amplitude and strain response. Computed results are compared with the corresponding response measurements for panels exposed to attached and separated flows at supersonic speeds and attached flow at subsonic speeds. The thin plate and the convected wave equations are coupled through the boundary condition on the panel to give a formula for the radiation pressure power spectra. A formula for the acoustical damping ratio of the panel is obtained through the principle of virtual work.-

Chyu, W. J.↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Green’s function methods for excited states and x-ray spectra of functional materials

Many interesting properties of functional materials, such as dynamic response and thermodynamic behavior, depend on their excited state properties. These functional properties are often related to excitations in the system, such as phonons and plasmons, which lead to inelastic losses, lifetime, and other dynamic effects. The excitations are pure many-body correlation effects that are missing from independent particle theories. They are revealed in x-ray spectra such as photoemission and absorption, where they show up as satellites beyond the quasi-particle approximation. Our main focus in this work is the use of Green's function methods to describe these effects. In particular, we discuss how the cumulant Green's function provides a unified treatment of such dynamic correlation effects in many contexts. Besides a robust theoretical framework, these methods also yield widely applicable tools for practical calculations of many functional properties of materials. Furthermore, this methodology is illustrated with a number of applications ranging from optical and x-ray spectra to thermodynamic properties, and dynamic response. Some recent extensions for more correlated systems are also briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CHIANTI-AN ATOMIC DATABASE FOR EMISSION LINES. XI. EXTREME-ULTRAVIOLET EMISSION LINES OF Fe VII, Fe VIII, AND Fe IX OBSERVED BY HINODE/EIS

A detailed study of emission lines from Fe VII, Fe VIII, and Fe IX observed by the EUV Imaging Spectrometer on board the Hinode satellite is presented. Spectra in the ranges 170-212 A and 246-292 A show strongly enhanced lines from the upper solar transition region (temperatures 5.4 <= log T <= 5.9) allowing a number of new line identifications to be made. Comparisons of Fe VII lines with predictions from a new atomic model reveal new plasma diagnostics, however there are a number of disagreements between theory and observation for emission line ratios insensitive to density and temperature, suggesting improved atomic data are required. Line ratios for Fe VIII also show discrepancies with theory, with the strong lambda185.21 and lambda186.60 lines underestimated by 60%-80% compared to lines between 192 and 198 A. A newly identified multiplet between 253.9 and 255.8 A offers excellent temperature diagnostic opportunities relative to the lines between 185 and 198 A, however the atomic model underestimates the strength of these lines by factors of 3-6. Two new line identifications are made for Fe IX at wavelengths 176.959 A and 177.594 A, while seven other lines between 186 and 200 A are suggested to be due to Fe IX but for which transition identifications cannot be made. The new atomic data for Fe VII and Fe IX are demonstrated to significantly modify models for the response function of the Transition Region And Coronal Explorer 195 A imaging channel, affecting temperature determinations from this channel. The data will also affect the response functions for other solar EUV imaging instruments such as SOHO/EIT, STEREO/EUVI, and the upcoming AIA instrument on the Solar Dynamics Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultraviolet absorption of common spacecraft contaminants

Organic contamination of ultraviolet optical systems is discussed. Degradation of signal by reflection, scattering, interference, and absorption is shown. The first three processes depend on the physical state of the contaminant while absorption depends on its chemical structure. The latter phenomenon is isolated from the others by dissolving contaminants in cyclohexane and determining absorption spectra from 2100A to 3600A. A variety of materials representing the types of contaminants responsible for most spaceflight hardware problems is scanned and the spectra is presented. The effect of thickness is demonstrated for the most common contaminant, di(2 ethyl hexyl)phthalate, by scanning successive dilutions.

Colony, J. A.↗

Infrared emission spectra of candidate interstellar aromatic molecules

Interstellar dust is responsible, through surface reactions, for the creation of molecular hydrogen, the main component of the interstellar clouds in which new stars form. Intermediate between small, gas-phase molecules and dust are the polycyclic aromatic hydrocarbons (PAHs). Such molecules could account for 2-30% of the carbon in the Galaxy, and may provide nucleation sites for the formation of carbonaceous dust. Although PAHs have been proposed as the sources of the unidentified infrared emission bands that are observed in the spectra of a variety of interstellar sources, the emission characteristics of such molecules are still poorly understood. Here we report laboratory emission spectra of several representative PAHs, obtained in conditions approximating those of the interstellar medium, and measured over the entire spectral region spanned by the unidentified infrared bands. We find that neutral PAHs of small and moderate size can at best make only a minor contribution to these emission bands. Cations of these molecules, as well as much larger PAHs and their cations, remain viable candidates for the sources of these bands.

Non-NASA Center↗

SNM Movement Detection/Radiation Sensors and Advanced Materials Portfolio Review, CdMnTe (CMT) Gamma Ray Detectors

The project goals are: (1) Develop CMT radiation detectors - Demonstrate feasibility (Phase 1 is complete) and Improve material properties and device performance; (2) This project will lead to novel radiation detectors - high detection efficiency, high energy-resolution, ambient-temperature operation, and low production cost; and (3) Such detectors are needed in areas of nonproliferation and national security for detection of SNM. Research highlights are: (1) We achieved our Phase-I goal - Demonstration of CMT detector performance approaching that of CZT detectors; (2) Demonstrated that In-doped CMT is much closer to its anticipated performance as radiation detectors than other alternative materials, TlBr and HgI{sub 2} - Large crystal volumes, 10{sup 10}{Omega}{center_dot}cm, 3 x 10{sup -3}cm{sup 2}/V, and stable response; and (3) Conducted material and device characterization experiments - Detectors: I-V, {mu}{sub e}, ({mu}{tau}){sub e}, internal E fields, energy spectra, and high-resolution x-ray response mapping data and Materials - DLTS, TCT, PL, EPDs, XRD, PCD and IR transmission.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Improved photo-degradation of dyes over Ag-loaded NiTiO3:V nanorods on visible-light-irradiation

Highlights: • Ag/NiTiO{sub 3}:V nanorods were prepared by electrospinning synthesis. • The crystalline crystal structure was refined. • The optical absorption and band structure were clarified. • Photocatalysis was greatly enhanced in Ag/NiTiO{sub 3}:V nanorods. • The photocatalysis activities and mechanisms were discussed. - Abstract: Pure and V-doped NiTiO{sub 3} (NiTiO{sub 3}:V) nanorods were synthesized via electrospinning synthesis using sol–gel precursors, followed by sintering the samples at 600 °C. And the subsequent Ag-loaded NiTiO{sub 3}:V nanorods were prepared by the chemical precipitation method (Ag/NiTiO{sub 3}:V). The phase formations were studied via X-ray powder diffraction (XRD) measurements. The Rietveld refinements were conducted to investigate the structural characteristics. The surface property of the nanorods was measured via morphologies and X-ray photon spectrascope (XPS) measurements. The absorption spectra of products indicate sufficient optical response in visible wavelength region. The indirect allowed band gap (2.18 eV) of NiTiO{sub 3} originates from the characteristic charge-transfer (CT) transitions of O{sup 2−} → Ti{sup 4+} (UV region) and Ni{sup 2+} → Ti{sup 4+} (visible light region). While Ag/NiTiO{sub 3}:V composites have a smaller band energy of 2.09 eV. The photocatalytic activities were investigated by photo-degradation of Rhodamine B (RhB) dye solutions under visible-light irradiation. The Ag/NiTiO{sub 3}:V nanorods were efficient for the photo-degradation of RhB dye solutions. EIS measurements were used to analyze the charge-carrier migration at the interfaces. The improved photocatalysis of Ag/NiTiO{sub 3}:V is ascribed to the narrowed band energy and enhanced efficiencies of the charge separations due to the Ag-coupling and V-doping in NiTiO{sub 3} lattices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Surface science insight note: Optimizing XPS instrument performance for quantification of spectra

X-ray photoelectron spectroscopy (XPS) provides quantitative information from photoemission peaks and shapes observed within the background due to the inelastic scattering of photoelectrons. To quantify the signal, both photoemission peaks and background in spectra must be adjusted for instrumental transmission variations that are a consequence of changes in efficiency when recording electrons with different kinetic energy. While it is generally assumed that correcting spectroscopic data for transmission is a necessary part of quantification by XPS, there are consequences for the quantification of spectra measured using an instrument for which transmission has significant curvature. In this Insight, the implications of curvature in transmission characteristics are discussed and a method based on XPS microscopy is proposed that ensures the transmission response of an instrument is free from significant curvature. An example of an instrument for which a flat transmission response is presented is achieved through collecting spectra using lens modes designed to measure stigmatic images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the construction of a new stellar classification template library for the LAMOST spectral analysis pipeline

The LAMOST spectral analysis pipeline, called the 1D pipeline, aims to classify and measure the spectra observed in the LAMOST survey. Through this pipeline, the observed stellar spectra are classified into different subclasses by matching with template spectra. Consequently, the performance of the stellar classification greatly depends on the quality of the template spectra. In this paper, we construct a new LAMOST stellar spectral classification template library, which is supposed to improve the precision and credibility of the present LAMOST stellar classification. About one million spectra are selected from LAMOST Data Release One to construct the new stellar templates, and they are gathered in 233 groups by two criteria: (1) pseudo g – r colors obtained by convolving the LAMOST spectra with the Sloan Digital Sky Survey ugriz filter response curve, and (2) the stellar subclass given by the LAMOST pipeline. In each group, the template spectra are constructed using three steps. (1) Outliers are excluded using the Local Outlier Probabilities algorithm, and then the principal component analysis method is applied to the remaining spectra of each group. About 5% of the one million spectra are ruled out as outliers. (2) All remaining spectra are reconstructed using the first principal components of each group. (3) The weighted average spectrum is used as the template spectrum in each group. Using the previous 3 steps, we initially obtain 216 stellar template spectra. We visually inspect all template spectra, and 29 spectra are abandoned due to low spectral quality. Furthermore, the MK classification for the remaining 187 template spectra is manually determined by comparing with 3 template libraries. Meanwhile, 10 template spectra whose subclass is difficult to determine are abandoned. Finally, we obtain a new template library containing 183 LAMOST template spectra with 61 different MK classes by combining it with the current library.

79 ASTRONOMY AND ASTROPHYSICS↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Nonstationary ascent wind analysis.

A statistical approach for computing launch vehicle response to inflight winds is presented. In the response analysis the zonal component of the ascent wind velocity is modeled as a nonstationary random process. Model parameters are computed by processing available measured wind data. Pertinent pitch plane response statistics are computed and their value in constructing fatigue load spectra for a reusable launch vehicle is demonstrated. A method for using the response statistics to estimate structural reliability is also discussed. The accuracy and the cost saving potential of the probabilistic structural dynamics approach are assessed by performing comparisons with digital simulation results.

Howell, L. J.↗