Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

FC Site 4.2 - NLR Scanning Lidar (Halo XR+ 199) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

FC Site 1.9 - NLR Scanning Lidar (Halo XR+ 200) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

Development of mechanized ultrasonic scanning system

Mechanized ultrasonic scanning system inspects the flaw content in the welds of space vehicle booster stages and propellant tanks. It is capable of scanning welds at speeds greater than 1 inch per second.

Evans, R.↗

Circuit enhances vertical resolution in raster scanning systems

Circuit enhances vertical resolution in electron beam, raster scanning systems exhibiting aperture distortion in the vertical direction. A sensitized area /image/ produces a video output when the scan beam nears it, which causes vertical elongation in the reconstructed images of all sensitized areas on the surface.

Alsovsky, W. H.↗

Using the scanning electron microscope on the production line to assure quality semiconductors

The use of the scanning electron microscope to detect metallization defects introduced during batch processing of semiconductor devices is discussed. A method of determining metallization integrity was developed which culminates in a procurement specification using the scanning microscope on the production line as a quality control tool. Batch process control of the metallization operation is monitored early in the manufacturing cycle.

Adolphsen, J. W.↗

A pressure scanning Fabry-Perot magnetometer.

Description of an oscillating magnetic analyzer (KDP crystal plus Glan-Thompson prism) coupled to an echelle-interferometer spectrograph, and of single-slit magnetometer which by pressure variations can be made to scan the entire profiles of the circularly and linearly polarized Zeeman components. Freon gas is used as the scanner gas with wavelength displacements of 0.02 A per 0.1 in. Hg pressure change at the NaD lines. The available scan range is 15 A in the visual spectral region.

Fay, T. D.↗

Two-dimensional area scanning with image dissectors.

An image dissector system for direct two-dimensional area scanning has been fabricated and is briefly described. Examples of application to direct scanning and digitization of photographic images are given.

Tifft, W. G.↗

A dynamic response and eye scanning data base useful in the development of theories and methods for the description of control/display relationships

A set of specially prepared digital tapes is reported which contain synchronized measurements of pilot scanning behavior, control response, and vehicle response obtained during instrument landing system approaches made in a fixed-base DC-8 transport simulator. The objective of the master tape is to provide a common data base which can be used by the research community to test theories, models, and methods for describing and analyzing control/display relations and interactions. The experimental conditions and tasks used to obtain the data and the detailed format of the tapes are described. Conventional instrument panel and controls were used, with simulated vertical gust and glide slope beam bend forcing functions. Continuous pilot eye fixations and scan traffic on the panel were measured. Both flight director and standard localizer/glide slope types of approaches were made, with both fixed and variable instrument range sensitivities.

Klein, R.↗

Scan converting video tape recorder

A video tape recorder is disclosed of sufficient bandwidth to record monochrome television signals or standard NTSC field sequential color at current European and American standards. The system includes scan conversion means for instantaneous playback at scanning standards different from those at which the recording is being made.

Holt, N. I.↗

Use of scan overlap redundancy to enhance multispectral aircraft scanner data

Two criteria were suggested for optimizing the resolution error versus signal-to-noise-ratio tradeoff. The first criterion uses equal weighting coefficients and chooses n, the number of lines averaged, so as to make the average resolution error equal to the noise error. The second criterion adjusts both the number and relative sizes of the weighting coefficients so as to minimize the total error (resolution error plus noise error). The optimum set of coefficients depends upon the geometry of the resolution element, the number of redundant scan lines, the scan line increment, and the original signal-to-noise ratio of the channel. Programs were developed to find the optimum number and relative weights of the averaging coefficients. A working definition of signal-to-noise ratio was given and used to try line averaging on a typical set of data. Line averaging was evaluated only with respect to its effect on classification accuracy.

Lindenlaub, J. C.↗

Spin scan imaging at Jupiter

The general feasibility of spin scan imaging from spinning platforms in outer planet orbiters was investigated. The study was limited to consideration of a typical orbiter mission to Jupiter with an orbit designed to provide repetitive close approaches to the Galilean satellites. Discussed are: (1) data requirements for imaging experiments at Jupiter and its satellites; (2) spin scan camera and baseline camera selection; and (3) operational considerations bearing on imager performance. A physical camera model including relationships identifying the supporting requirements was developed and used to determine the characteristics of the baseline camera.

Sinclair, K. F.↗

Meteorological interpretations of the images from Nimbus 5 electrically scanned microwave radiometer

The Electrically Scanned Microwave Radiometer on the Nimbus 5 satellite measures microwave radiation in a band centered at 1.55 cm. It scans perpendicular to the satellite motion from 50 deg to the left to 50 deg to the right in the 78 steps every 4 seconds producing an image with a best resolution of 25 km. It is shown that these images can be used to delineate areas of rain over the oceans. This data can be used to approximate the location of fronts, the rain/snow boundary and secondary cyclogenesis.

Wilheit, T.↗

High resolution obtained by photoelectric scanning techniques.

Several applications of linear scanning of different types of objects are described; examples include double stars, satellites, the Red Spot of Jupiter and a landing site on the moon. This technique allows one to achieve a gain of about an order of magnitude in resolution over conventional photoelectric techniques; it is also effective in providing sufficient data for removing background effects and for the application of deconvolution procedures. Brief consideration is given to two-dimensional scanning, either at the telescope or of electronographic images in the laboratory. It is suggested that some of the techniques described should be given serious consideration for space applications.

Hall, J. S.↗

Simple model for scanning-angle distribution of planetary albedo gamma-rays.

The planetary atmosphere is scanned from a satellite located at a point at an altitude of 500 km from the subsatellite point on the surface (the altitude of the satellite OSO-3). Results point out the possibility that by scanning a planet from the subsatellite point to the limb with a high resolution gamma ray detector on an orbiting satellite, the mean total baryonic scale height may be unfolded from the angular distribution of the gamma-ray flux without having to determine chemical composition and temperature.

Stecker, F. W.↗

Photosensor aperture shaping to reduce aliasing in optical-mechanical line-scan imaging systems.

Review of optical-mechanical scanning techniques that are generally employed in instruments specifically designed to characterize variations in scene brightness spectrally or radiometrically. Special attention is given to the effect of aliasing on the spatial detail of the reconstructed image. Aliasing may be caused by linescan sampling and can, in turn, severely degrade images that emphasize the spatial characterization of a scene. Photosensor aperture shaping and line-scan spacing are investigated as means for reducing this degradation.

Katzberg, S. J.↗