At least 379 records · Page 21

X ray analysis of balloon-collected particles erroneously considered as an October influx into the lower stratosphere

Individual particles were analyzed on the collection screens in a Jeolco scanning electron microscope using a Kevex Li-drifted silicon energy dispersive X ray detector. It was found that the bulk of the stratospheric samples studied comes from explosive squib devices. It is pointed out that this finding does not invalidate the extensive results obtained by Bigg et al. (1970, 1971) in previous sampling experiments.

Farlow, N. H.↗

Preliminary design study. Shuttle modular scanning spectroradiometer

Fundamental concepts on which to base a detailed design for a Shuttle Modular Scanning Spectroradiometer were developed, and a preliminary design is presented. The recommended design features modularity and flexibility. It includes a 75-cm f/1.7-telescope assembly in an all-reflective Schmidt configuration, a solid state scan system (pushbroom) with high resolution over a 15 deg field of view, and ten detector channels covering the spectral range from 0.45 to 12.5 micrometers. It uses charge transfer device techniques to accommodate a large number of detector elements for earth observation measurements. Methods for in-flight radiometric calibration, for image motion compensation, and for data processing are described. Recommendations for ground support equipment are included, and interfaces with the shuttle orbiter vehicle are illustrated.

Source record↗

The Orthogonal In-Situ Machining of Single and Polycrystalline Aluminum and Copper, Volume 1

Metal cutting is a unique deformation process characterized by large strains, exceptionally high strain rates and few constraints to the deformation. These factors, along with the difficulty of directly measuring the shear angle, make chip formation difficult to model and understand. One technique for skirting the difficulty of post mortem chip measurement is to perform a cutting experiment dynamically in a scanning electron microscope. The performance of the in-situ experiment with full instrumentation allows for component force measurement, orientation measurement (on a round single crystal disk) and a timing device, all superimposed below the deformation on the TV monitor and recorded for future viewing. This allows the sher angle to be directly measured for the screen along with the other needed information.

Cohen, P. H.↗

Holder for Ultrasonic Evaluation of Small-Diameter Tubes

Simple holder eliminates requirement for expensive turntable. Holder works by rotating cylindrical specimens about y-axis. Rotation synchronized with movement of transducer to permit testing without use of turntable. Holder attached to crossmember of scanning bridge with C-clamp. Permits testing of small-diameter tubes rapidly, accurately, and economically. Designed for use with commercially available electromechanical drum-type ultrasonic immersion testing device used for nondestructive evaluation of variety of materials.

Taylor, E. C.↗

Surface texture characterization by angular distributions of scattered light

Work at the National Bureau of Standards to develop an on-line optical measurement device and attendant algorithms for automated optical scattering measurements of machined metal surfaces are described. The surfaces could be milled, ground or lapped, and the system is intended to categorize the resulting surface characteristics. The optical device consists of a He-Ne laser which is shone on a surface. The scattered light is captured by a semicircular array of 87 detector elements rotated over the scanned area. The light signals are processed through a digital voltmeter and then an A/D converter. The signals are then stored for later comparisons with optical scattering data obtained by optical instruments used with stylus instruments for characterizing surface topographies. A theoretical model has been defined which relates light scattering and the characteristics of the surface roughness. Initial experimental results with a sinusoidal surface have indicated that although the system can follow the trend of the roughness, the roughness amplitude is as yet uncertainly defined and the computations require excessive time.

Gilsinn, D. E.↗

Planetary investigation utilizing an imaging spectrometer system based upon charge injection technology

An intrinsic silicon charge injection device (CID) television sensor array has been used in conjunction with a CaMoO4 colinear tunable acousto optic filter, a 61 inch reflector, a sophisticated computer system, and a digital color TV scan converter/computer to produce near IR images of Saturn and Jupiter with 10A spectral resolution and approximately 3 inch spatial resolution. The CID camera has successfully obtained digitized 100 x 100 array images with 5 minutes of exposure time, and slow-scanned readout to a computer. Details of the equipment setup, innovations, problems, experience, data and final equipment performance limits are given.

Wattson, R. B.↗

Optical Detection of Blade Flutter

Dynamic strain gages mounted on rotor blades are used as the primary instrumentation for detecting the onset of flutter and defining the vibratory mode and frequency. Optical devices are evaluated for performing the same measurements as well as providing supplementary information on the vibratory characteristics. Two separate methods are studied: stroboscopic imagery of the blade tip and photoelectric scanning of blade tip motion. Both methods give visual data in real time as well as video tape records. The optical systems are described, and representative results are presented. The potential of this instrumentation in flutter research is discussed.

Nieberding, W. C.↗

Zodiacal light dynamics experiment: A wideband imaging Fabry-Perot interferometer

The Solar Probe will provide an ideal platform from which to study dynamics of dust particles near the sun by measuring the detailed character of the Fraunhofer structure of the zodiacal light. The suggested instrument is a wideband imaging Fabry-Perot interferometer with state of the art technology in both the optics and the detector. The instrument would function as a high-resolution imaging device providing wavelength resolution of 0.03 A over about a 20 A range. The wideband imaging capability would provide sky maps of the zodiacal light on a despun spacecraft without mechanical scanning. The Solar Probe mission would allow the velocity distribution of the dust to be mapped along most of the trajectory of the spacecraft.

Torr, D. G.↗

Advanced CID array multispectral pushbroom scanner

An optical imager, called the Scanning Imaging Spectroradiometer (SIS), was built for NASA in the early 1970's. Later, the Solidstate Array Spectroradiometer (SAS) was developed on the basis on a substitution of a Charge Injection Device (CID) array for the vidicon of the SIS. The Advanced Solidstate Array Spectroradiometer (ASAS) represents an improvement of the SAS. ASAS is a solidstate multispectral optical imaging radiometer which is currently the most versatile instrument of its type in the visible part of the spectrum. The instrument is capable of absolute radiometric measurements in all of its 32 bands. ASAS can be easily mounted in small aircraft as well as high altitude craft such as the U-2, taking into account also the possibility of a use in the Space Shuttle. The instrument consists of three separate subsystems. Attention is given to the optics, the detector array, data storage, data retrieval, and system performance.

Stewart, S. E.↗

Processing Laser-Velocimetric Data By Vector Scanning

Velocity plots obtained in minutes instead of hours. Velocity scanning technique for processing flow-field data from pulsed-laser-velocimetry images into two-dimensional velocity-vector maps. Requires no special equipment other than charge-coupled-device (CCD) camera, circuitry to digitize output of camera, and computer. Once image data digitized, all processing done in computer.

Wernet, Mark P.↗

Solar flare gamma-ray and hard x ray imaging with the GRID-on-a-balloon

A primary scientific objective for solar flare research during the rapidly approaching maximum in solar activity is the imaging of gamma-ray and hard x ray sources of solar flare emissions. These goals will be pursued by the Gamma Ray Imaging Device (GRID) instrument, one of three instruments recently selected for NASA's Max '91 Solar Balloon Program. The GRID instrument is based on the technique of Fourier transform imaging and utilizes scanning modulation grid collimator optics to provide full-Sun imaging with 1.9-arcsecond resolution over the energy range from 20 to 700 keV at time resolutions from 0.1 to 2 s. The GRID telescope will employ 32 subcollimators, each composed of a matched pair of high-Z collimator grids separated by 5.2 meters and a phoswich scintillation spectrometer detector having no spatial resolution. The subcollimators and integrally-mounted fine aspect system are contained within a telescope canister which will be pointed to 0.1 degree accuracy and cyclically scanned to produce source modulation. The 32 subcollimators provide a uniform distribution of grid slit orientations and a logarithmic distribution of slit spacings corresponding to angular dimensions of 1.9 arcseconds to several arcminutes. The instrument is several orders of magnitude more sensitive than the HXIS instrument on the Solar Maximum Mission (SMM) and nearly 10 times more sensitive than any similar instrument scheduled to fly during the next solar maximum. The payload, designed for long-duration high-altitude balloon capability, is scheduled for its first science flight (8 to 14 days duration) from the Antarctic in January of 1992.

Orwig, Larry E.↗

Boiling on Microconfigured Composite Surfaces Enhanced

Boiling heat transfer is one of the key technologies for the two-phase active thermal-control system used on space platforms, as well as for the dynamic power systems aboard the International Space Station. Because it is an effective heat transfer mode, boiling is integral to many space applications, such as heat exchangers and other cooling devices. Nucleate boiling near the critical heat flux (CHF) can transport very large thermal loads with a much smaller device and much lower pumping power than for single-phase heat exchangers. However, boiling performance sharply deteriorates in a reduced-gravity environment, and operation in the CHF regime is somewhat perilous because of the risk of burnout to the device surface. New materials called microconfigured metal-graphite composites can enhance boiling. The photomicrograph shows the microconfiguration (x3000) of the copper-graphite (Cu-Gr) surface as viewed by scanning electronic microscope. The graphite fiber tips appear as plateaus with rugged surfaces embedded in the copper matrix. It has been experimentally demonstrated that this type of material manifests excellent boiling heat transfer performance characteristics and an increased CHF. Nonisothermal surfaces were less sensitive to variations of wall superheat in the CHF regime. Because of the great difference in conductivity between the copper base and the graphite fiber, the composite surfaces have a nonisothermal surface characteristic and, therefore, will have a much larger "safe" operating region in the CHF regime. In addition, the thermocapillary forces induced by the temperature differences between the fiber tips and the metal matrix play an important role in bubble detachment, and may not be adversely affected in a reduced-gravity environment. All these factors indicate that microconfigured composites may improve the reliability and economy (dominant factors in all space applications) of various thermal components found on spacecraft during future missions.

Chao, David F.↗

Optical grating evaluator - A device for detailed measurement of diffraction grating efficiencies in the vacuum ultraviolet

A device for detailed measurement of diffraction grating efficiencies and over-all performance in the VUV has been designed and constructed at the Naval Research Laboratory. The system employs semiautomated mechanisms to scan the face of the grating with a narrow monochromatic beam, and an efficiency map of the grating surface is produced on a strip chart recorder. Grating efficiency in the various diffracted orders and intensity of light scattered between orders may also be measured. A unique feature is the ability to determine the angle and effectiveness of grating blaze and variations in blaze under different conditions of illumination.

Michels, D. J.↗

Recent developments in space-borne zodiacal light photometry

The zodiacal light experiment to be flown aboard the International Solar Polar Mission in 1985 is presented. Overall objectives of the Zodiacal Light/Background Starlight Experiment include the study of the brightness, polarization, and color of the diffuse sky brightness and the determination of the spatial distributions and physical properties of the interplanetary dust as a function of spacecraft position in and out of the ecliptic. To meet these objectives, a multicolor sky-scanning photopolarimeter will be carried on the NASA spacecraft which will provide optimized stray light suppression and a capability for changing the viewing cone angle based on the use of a stepping device. Brightness and polarization measurements will be made for 11 center wavelengths in the UV and visible with 5.6 deg circular and 1.0 sq deg rectangular fields of view.

Schwehm, G. H.↗

Images of the future - Two decades in astronomy

Future instruments for the 100-10,000 A UV-wavelength region will require detectors with greater quantum efficiency, smaller picture elements, a greater wavelength range, and greater active area than those currently available. After assessing the development status and performance characteristics of vidicons, image tubes, electronographic cameras, digicons, silicon arrays and microchannel plate intensifiers presently employed by astronomical spacecraft, attention is given to such next-generation detectors as the Mosaicked Optical Self-scanned Array Imaging Camera, which consists of a photocathode deposited on the input side of a microchannel plate intensifier. The problems posed by the signal processing and data analysis requirements of the devices foreseen for the 21st century are noted.

Weistrop, D.↗

Using neural networks to assist in OPAD data analysis

The space shuttle main engine (SSME) became the subject of plume emission spectroscopy in 1986 when researchers from NASA-Marshall Space Flight Center (MSFC), Arnold Engineering Development Center (AEDC), and Rocketdyne went to the SSME test stands at the NASA-Stennis Space Center and at Rocketdyne's Santa Susan Field Laboratory to optically observe the plume. Since then, plume spectral acquisitions have recorded many nominal tests and the qualitative spectral features of the SSME plume are now well established. Significant discoveries made with both wide-band and narrow-band plume emission spectroscopy systems led MSFC to promote the Optical Plume Anomaly Detection (OPAD) program with a goal of instrumenting all SSME test stands with customized spectrometer systems. A prototype OPAD system is now installed on the SSME Technology Test Bed (TTB) at MSFC. The OPAD system instrumentation consists of a broad-band, optical multiple-channel analyzer (OMA) and a narrow-band device called a polychrometer. The OMA is a high-resolution (1.5-2.0 Angstroms) 'super-spectrometer' covering the near-ultraviolet to near-infrared waveband (2800-7400 Angstroms), providing two scans per second. The polychrometer consists of sixteen narrow-band radiometers: fourteen monitoring discrete wavelengths of health and condition monitoring elements and two dedicated to monitoring background emissions. All sixteen channels are capable of providing 500 samples per second. To date, the prototype OPAD system has been used during 43 SSME firings on the TTB, collecting well over 250 megabytes of plume spectral data. One goal of OPAD data analysis is to determine interatively with the help of a computer code, SPECTRA4, developed at AEDC. Experience has shown that iteration with SPECTRA4 is an incredibly labor intensive task and not one to be performed by band. What is really needed is the 'inverse' of SPECTRA4 but the mathematical model for this inverse mapping is tenuous at best. However, the robustness of PSECTRA4 run in the 'forward' direction means that accurate input/output mappings can be obtained. If the mappings were inverted (i.e., input becomes output and output becomes input) then an 'inverse' of SPECTRA4 would be at hand but the 'model' would be specific to the data utilized and would in no way be general. Building a generalized model based upon known input/output mappings while ignoring the details of the governing physical model is possible through the use of a neural network. The research investigation described involves the development of a neural network to provide a generalized 'inverse' of SPECTRA4. The objectives of the research were to design an appropriate neural network architecture, train the network, and then evaluate its performance.

Whitaker, Kevin W.↗

Effect of Alignment on Transport Properties of Carbon Nanotube/Metallic Junctions

Ballistic and spin coherent transport in single walled carbon nanotubes (SWCNT) are predicted to enable high sensitivity single-nanotube devices for strain and magnetic field sensing. Based upon these phenomena, electron beam lithography procedures have been developed to study the transport properties of purified HiPCO single walled carbon nanotubes for development into sensory materials for nondestructive evaluation. Purified nanotubes are dispersed in solvent suspension and then deposited on the device substrate before metallic contacts are defined and deposited through electron beam lithography. This procedure produces randomly dispersed ropes, typically 2 - 20 nm in diameter, of single walled carbon nanotubes. Transport and scanning probe microscopy studies have shown a good correlation between the junction resistance and tube density, alignment, and contact quality. In order to improve transport properties of the junctions a technique has been developed to align and concentrate nanotubes at specific locations on the substrate surface. Lithographic techniques are used to define local areas where high frequency electric fields are to be concentrated. Application of the fields while the substrate is exposed to nanotube-containing solution results in nanotube arrays aligned with the electric field lines. A second electron beam lithography layer is then used to deposit metallic contacts across the aligned tubes. Experimental measurements are presented showing the increased tube alignment and improvement in the transport properties of the junctions.

Wincheski, Buzz↗

Computer control of a scanning electron microscope for digital image processing of thermal-wave images

Using a recently developed technology called thermal-wave microscopy, NASA Lewis Research Center has developed a computer controlled submicron thermal-wave microscope for the purpose of investigating III-V compound semiconductor devices and materials. This paper describes the system's design and configuration and discusses the hardware and software capabilities. Knowledge of the Concurrent 3200 series computers is needed for a complete understanding of the material presented. However, concepts and procedures are of general interest.

Gilbert, Percy↗