Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Rocket plume spectrometry: A system permitting engine condition monitoring, as applied to the technology test bed engine

The appearance of visible objects in the exhaust plume of space shuttle main engines (SSME) during test firings is discussed. A program was undertaken to attempt to identify anomalous material resulting from wear, normal or excessive, of internal parts, allowing time monitoring of engine condition or detection of failure precursors. Measurements were taken during test firings at Stennis Space Center and at the Santa Suzanna facility in California. The results indicated that a system having high spectral resolution, a fast time response, and a wide spectral range was required to meet all requirements, thus two special systems have been designed and built. One is the Optical Plume Anomaly Detector (OPAD). The other instrument, which is described in this report, is the superspectrometer, an optical multichannel analyzer having 8,192 channels covering the spectral band 250 to 1,000 nm.

Powers, W. T.↗

Inversion of imaging spectrometry data using singular value decomposition

The use of imaging spectrometers, which acquire data that are both spectrally contiguous images and spatially contiguous spectra, for quantitative remote sensing of the earth is addressed. Such data sets cannot be analyzed fully using either existing spectroscopic or image techniques. Singular value decomposition (SVD) is used here for spectral unmixing and determination of the spatial scales of mixing. It is shown that when it is used to invert the mixing endmember library, SVD allows more insight into library characteristics and more control of the inversion process than other commonly used matrix inversion techniques.

Boardman, Joe W.↗

Negative thermal ion mass spectrometry of osmium, rhenium, and iridium

This paper describes a technique for obtaining, in a conventional surface ionization mass spectrometer, intense ion beams of negatively charged oxides of Os, Re, and Ir by thermal ionization. It is shown that the principal ion species of these ions are OsO3(-), ReO4(-), and IrO2(-), respectively. For Re-187/Os-187 studies, this technique offers the advantage of isotopic analyses without prior chemical separation of Re from Os.

Creaser, R. A.↗

Exploring the lunar mantle with secondary ion mass spectrometry - A comparison of lunar picritic glass beads from the Apollo 14 and Apollo 17 sites

Results are presented from SIMS analyses of major, minor, and trace elements in lunar picritic glass beads obtained from the Apollo 14 (A-14) and Apollo 17 (A-17) landing sites. The results obtained indicate that the glasses from each site differed significantly in their Ba/Sr and light-REE/heavy-REE ratios. The differences between the A-14 and the A-17 glasses appear to be the result of a higher KREEP component in all the A-14 glasses, indicating that the mantle source of the A-14 site is intrinsically different from the A-17 mantle source.

Shearer, C. K.↗

High Resolution Imaging Spectrometer (HIRIS) - A major advance in imaging spectrometry

HIRIS, a facility instrument on the Earth Observing System Platform, will enable scientists to both identify and interpret changes, in the global environment, at a level of detail unavailable with previous instrumentation. This instrument will make localized measurements of biological, ecological, climatological, hydrological, and geological properties, and, with its finer wavelength sampling and full spectral coverage over the wavelength region of interest, will allow these properties to be identified and studied quantitatively from space. The data obtained will be downlinked from space, processed, catalogued, stored in active archives for easy access, and distributed to users.

Rockey, Donald E.↗

Analysis of model Titan atmospheric components using ion mobility spectrometry

The Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS) was proposed as an analytical technique for the analysis of Titan's atmosphere during the Cassini Mission. The IMS is an atmospheric pressure, chemical detector that produces an identifying spectrum of each chemical species measured. When the IMS is combined with a GC as a GC-IMS, the GC is used to separate the sample into its individual components, or perhaps small groups of components. The IMS is then used to detect, quantify, and identify each sample component. Conventional IMS detection and identification of sample components depends upon a source of energetic radiation, such as beta radiation, which ionizes the atmospheric pressure host gas. This primary ionization initiates a sequence of ion-molecule reactions leading to the formation of sufficiently energetic positive or negative ions, which in turn ionize most constituents in the sample. In conventional IMS, this reaction sequence is dominated by the water cluster ion. However, many of the light hydrocarbons expected in Titan's atmosphere cannot be analyzed by IMS using this mechanism at the concentrations expected. Research at NASA Ames and PCP Inc., has demonstrated IMS analysis of expected Titan atmospheric components, including saturated aliphatic hydrocarbons, using two alternate sample ionizations mechanisms. The sensitivity of the IMS to hydrocarbons such as propane and butane was increased by several orders of magnitude. Both ultra dry (waterless) IMS sample ionization and metastable ionization were successfully used to analyze a model Titan atmospheric gas mixture.

Kojiro, D. R.↗

Lunar surface - Sputtering and secondary ion mass spectrometry

Laboratory and Apollo observations are combined to describe the sputtering of the lunar surface and the composition of the ejecta with special reference to O. The atmospheric inventory appears to be dominated by micrometeorite vaporization of lunar grains. Sputtering effects are observable in the local plasma due to ion ejection, in the extended atmosphere through energetic neutral ejection, and on grain surfaces through the chemical fractionation of the redoposited sputter-ejecta. Ionization of the micrometeorite-vapor also contributes to the local plasma.

Johnson, R. E.↗

Determination of C1-C4 alkanes by ion mobility spectrometry

Results are presented from a comparison between two ion-mobility-spectrometer (IMS) methods of sample ionisation: a conventional IMS with very dry helium and an IMS using metastable helium ionization. As one of the tests, a mixture of several hydrocarbons expected to be the components of Titan's atmosphere (made of ethane, ethylene, acetylene, propane, n-butane, isobutane, and propyne in concentrations from 20 to 200 ppm) was analyzed by both methods. Results from the dry-He IMS showed that the dry-helium approach was more adequate for the analysis of these gases than the metastable-helium IMS approach. In the metastable-He approach, in which several versions of He ionization reaction were tested, the spectra produced were not as clear as the conventional IMS spectra, due to the fact that the strong electric field introduced in the reaction region to generate metastable helium affected the gating, resolution, and collection of the ions.

Kojiro, Daniel R.↗

Fourier transform spectrometry for fiber-optic sensor systems

An integrated-optic Mach-Zehnder interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This type of spectrometer has an advantage over conventional grating spectrometers because it is better suited for use with time-division-multiplexed sensor networks. In addition, this spectrometer has the potential for low cost due to its use of a component that could be manufactured in large quantities for the optical communications industry.

Beheim, Glenn↗

Demonstration of Fabry-Perot interferometric spectrometry technology

As rocket engine components experience wear or failure, anomalous materials may be entrained in the plume. Historically, visible plume anomalies have preceded many rocket engine failures, some of which have been catastrophic. Development of a small, rugged, high-speed, high resolution Fabry-Perot interferometer (FPI) based spectrometer capable of detecting the spectral signatures of eroding engine components during rocket engine test and/or flight operations is described. An operational plume spectrometer fabricated with miniaturized optics has been successfully tested. An extensive test series was conducted to define the limits of the spectrometer with respect to time-response and resolution. The data collected during testing were correlated with measurements obtained using sensitive ground equipment in order to benchmark the spectrometer's performance against a known device. The FPI demonstrated the reliability required for a flight instrument by functioning satisfactorily at or near the rocket engine test stand environment. Several of the optical components are interchangeable, allowing collection of a greater variety of plume signals. Also, the FPI's high resolution capabilities suggest it is suitable for application to both absorption and emission spectroscopy.

Petersen, T. V.↗

Simulation of UV atomic radiation for application in exhaust plume spectrometry

Quantitative analysis of exhaust plume spectral data has long been a goal of developers of advanced engine health monitoring systems which incorporate optical measurements of rocket exhaust constituents. Discussed herein is the status of present efforts to model and predict atomic radiation spectra and infer free-atom densities from emission/absorption measurements as part of the Optical Plume Anomaly Detection (OPAD) program at Marshall Space Flight Center (MSFC). A brief examination of the mathematical formalism is provided in the context of predicting radiation from the Mach disk region of the SSME exhaust flow at nominal conditions during ground level testing at MSFC. Computational results are provided for Chromium and Copper at selected transitions which indicate a strong dependence upon broadening parameter values determining the absorption-emission line shape. Representative plots of recent spectral data from the Stennis Space Center (SSC) Diagnostic Test Facility (DTF) rocket engine are presented and compared to numerical results from the present self-absorbing model; a comprehensive quantitative analysis will be reported at a later date.

Wallace, T. L.↗

Remote sensing x ray fluorescence spectrometry for future lunar exploration missions

Measurement of discrete line X-ray emission from space can be used to obtain both qualitative and quantitative elemental surface composition information. Remote orbital X-ray elemental analysis is the measurement of characteristic X-rays following the interaction of solar X-rays with the surface of a given solid body. Thus, X-ray emission from a surface is strongly dependent on the incident solar spectrum as well as on the chemical composition of the surface. In this paper, the relationship between the solar flux and the major lunar element fluorescence and scattered X-ray flux is characterized. A model was developed to calculate lunar surface X-ray fluorescence emission spectra under a variety of solar conditions and, in particular, conditions that might be expected for a Lunar Scout mission proposed for 1995 or 1996. This time period should be during solar minimum.

Clark, Pamela E.↗

Ground truth spectrometry and imagery of eruption clouds to maximize utility of satellite imagery

Field experiments with thermal imaging infrared radiometers were performed and a laboratory system was designed for controlled study of simulated ash clouds. Using AVHRR (Advanced Very High Resolution Radiometer) thermal infrared bands 4 and 5, a radiative transfer method was developed to retrieve particle sizes, optical depth and particle mass involcanic clouds. A model was developed for measuring the same parameters using TIMS (Thermal Infrared Multispectral Scanner), MODIS (Moderate Resolution Imaging Spectrometer), and ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer). Related publications are attached.

Rose, William I.↗

Stratospheric minor species vertical distributions during polar winter by balloon borne UV-Vis spectrometry

A light, relatively cheap and easy to operate balloonborne UV-visible spectrometer was designed for investigating ozone photochemistry in the Arctic winter. The instrument was flown 11 times during the European Arctic Stratospheric Ozone Experiment (EASOE) in winter 1991-92 in Northern Scandinavia. The first simultaneous measurements of vertical distributions of aerosols, PSC's, O3, NO2 and OClO inside the vortex during flight no. 6 on 16 January, in cold conditions are reported, which show that nitrogen oxides were almost absent (lower than 100 ppt) in the stratosphere below 22 km, while a layer of relatively large OClO concentration (15 ppt) was present at the altitude of the minimum temperature.

Pommereau, J. P.↗

Four years of ground-based total ozone measurements by visible spectrometry in Antarctica

Visible spectrometers SAOZ have been developed at Service d'Aeronomie for permanent ground-based ozone monitoring at all latitudes up to the polar circle in winter. Observations are made by looking at the sunlight scattered at zenith in the visible range, twice a day, at sunrise and sunset. Compared to ozone observations in the UV generally in use, visible observations in the small Chappuis bands at twilight have the advantages of being independent of stratospheric temperature, little contaminated by tropospheric ozone and multiple scattering, and of permitting observations even in winter at the polar circle. SAOZ instruments have been installed since 1988 at several stations in the Antarctic and the Arctic. More than four years data at Dumont d'Urville in Terre Adelie (67 deg S) are now available. The station is generally located at the edge of the vortex in spring and therefore the ozone hole is seen there only occasionally. The lowest values (140 DU) were reported in early October 1991. According to these first regular observations throughout the whole winter ozone seems to increase in late autumn and winter. Its decay does not start before the end of August. Although of smaller amplitude than with the previous version five data, the ratio between the groundbased and satellite/TOMS measurements displays a systematic seasonal variation correlated partly to the sun zenith angle of observations from orbit and partly to the temperature of the stratosphere. Since ground-based measurements are always made at 90 deg SZA, the SZA dependence must come from the satellite data interpretation (TOMS observations are between 43 to 88 deg SZA). The temperature dependence could be partly due to variations of ozone absorption cross-sections in the ultraviolet used by the satellite spectrometer, and partly to a systematic seasonal cycle of the air mass factor use in the interpretation of the ground based observations. However, the last contribution appears to be too small to compensate the ozone increase in winter reported by SAOZ, which is then real.

Goutail, F.↗

Secondary ion mass spectrometry (SIMS) analysis of hypervelocity microparticle impact sites on LDEF surfaces

Two dimensional elemental ion maps have been recorded for hundreds of microparticle impact sites and contamination features on LDEF surfaces. Since the majority of the analyzed surfaces were metal-oxide-silicon (MOS) impact detectors from the Interplanetary Dust Experiment, a series of 'standard' and 'blank' analyses of these surfaces are included. Hypervelocity impacts of forsterite olivine microparticles on activated flight sensors served as standards while stylus and pulsed laser simulated 'impacts' served as analytical blanks. Results showed that despite serious contamination issues, impactor residues can be identified in greater than 1/3 of the impact sites. While aluminum oxide particles could not be detected on aluminum surfaces, they were detected on germanium surfaces from row 12. Remnants of manmade debris impactors consisting of paint chips and bits of metal were identified on surfaces from LDEF Rows 3 (west or trailing side), 6 (south), 9 (ram or leading side), 12 (north) and the space end. Higher than expected ratios of manmade microparticle impacts to total microparticle impacts were found on the space end and the trailing side. These results were consistent with time-tagged and time-segregated microparticle impact data from the IDE and other LDEF experiments. A myriad of contamination interferences were identified and their effects on impactor debris identification mitigated during the course of this study. These interferences include pre-, post and inflight deposited surface contaminants as well as indigenous heterogeneous material contaminants. Non-flight contaminations traced to human origins, including spittle and skin oils, contributed significant levels of alkali-rich carbonaceous interferences. A ubiquitous layer of in-flight deposited silicaceous contamination varied in thickness with location on LDEF, even on a micro scale. In-flight deposited (low velocity) contaminants include urine droplets and bits of metal film from eroded thermal blankets.

Simon, C. G.↗

The effect of sample holder material on ion mobility spectrometry reproducibility

When a positive detection of a narcotic occurs during the search of a vessel, a decision has to be made whether further intensive search is warranted. This decision is based in part on the results of a second sample collected from the same area. Therefore, the reproducibility of both sampling and instrumental analysis is critical in terms of justifying an in depth search. As reported at the 2nd Annual IMS Conference in Quebec City, the U.S. Coast Guard has determined that when paper is utilized as the sample desorption medium for the Barringer IONSCAN, the analytical results using standard reference samples are reproducible. A study was conducted utilizing papers of varying pore sizes and comparing their performance as a desorption material relative to the standard Barringer 50 micron Teflon. Nominal pore sizes ranged from 30 microns down to 2 microns. Results indicate that there is some peak instability in the first two to three windows during the analysis. The severity of the instability was observed to increase as the pore size of the paper is decreased. However, the observed peak instability does not create a situation that results in a decreased reliability or reproducibility in the analytical result.

Jadamec, J. Richard↗