Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Separation of Artifacts from Spin–Torque Ferromagnetic Resonance Measurements of Spin–Orbit Torque for the Low–Symmetry Van der Waals Semi–Metal ZrTe 3

Spin-orbit torques generated by exfoliated layers of the low-symmetry semi-metal ZrTe 3 are measured using the spin-torque ferromagnetic resonance (ST-FMR) technique. When the ZrTe 3 has a thickness greater than about 10 nm, artifacts due to spin pumping and/or resonant heating can cause the standard ST-FMR analysis to overestimate the true magnitude of the torque efficiency by as much as a factor of 30, and to indicate incorrectly that the spin-orbit torque depends strongly on the ZrTe 3 layer thickness. Artifact-free measurements can still be achieved over a substantial thickness range by the method developed recently to detect ST-FMR signals in the Hall geometry as well as the longitudinal geometry. ZrTe 3 /Permalloy samples generate a conventional in-plane anti-damping spin torque efficiency ξ$^{FL}_{∥}$ = 0.014 ± 0.004, and an unconventional in-plane field-like torque efficiency |ξ$^{FL}_{∥}$| = 0.003 ± 0.001. As a result, the out-of-plane anti-damping torque is negligible. It is suggested that artifacts similarly interfere with the standard ST-FMR analysis for other van der Waals samples thicker than about 10 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated High‐Throughput Fatigue Testing of Freestanding Thin Films

Abstract Mechanical testing at small length scales has traditionally been resource‐intensive due to difficulties with meticulous sample preparation, exacting load alignments, and precision measurements. Microscale fatigue testing can be particularly challenging due to the time‐intensive, tedious repetition of single fatigue experiments. To mitigate these challenges, this work presents a new methodology for the high‐throughput fatigue testing of thin films at the microscale. This methodology features a microelectromechanical systems‐based Si carrier that can support the simultaneous and independent fatigue testing of an array of samples. To demonstrate this new technique, the microscale fatigue behavior of nanocrystalline Al is efficiently characterized via this Si carrier and automated fatigue testing with in situ scanning electron microscopy. This methodology reduces the total testing time by an order of magnitude, and the high‐throughput fatigue results highlight the stochastic nature of the microscale fatigue response. This manuscript also discusses how this initial capability can be adapted to accommodate more samples, different materials, new geometries, and other loading modes.

Barrios, Alejandro↗

magnetoARPES: Angle Resolved Photoemission Spectroscopy with magnetic field control

Angle-Resolved Photoemission Spectroscopy (ARPES) is a premier technique for understanding the electronic excitations in conductive, crystalline matter, in which the induced photocurrent is collected and dispersed in energy and angle of emission to reveal the energy- and momentum-dependent single particle spectral function A (k,ω). So far, ARPES in a magnetic field has been precluded due to the need to preserve the electron paths between the sample and detector. Here, in this paper we report progress towards “magnetoARPES”, a variant of ARPES that can be conducted in a magnetic field. It is achieved by applying a microscopic probe beam (≲10 μm) to a thinned sample mounted upon a special sample holder that generates magnetic field confined to a thin layer near the sample surface. In this geometry we could produce ARPES in magnetic fields up to around ±100 mT. The magnetic fields can be varied from purely in-plane to nearly purely out-of-plane, by scanning the probe beam across different parts of the device. We present experimental and simulated data for graphene to explore the aberrations induced by the magnetic field. These results demonstrate the viability of the magnetoARPES technique for exploring symmetry breaking effects in weak magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the onset of deformation twinning in the CrFeMnCoNi high-entropy alloy using a novel tensile specimen geometry

Deformation-induced nanoscale twinning is one of the mechanisms responsible for the excellent combination of strength and fracture toughness of the single-phase, face-centered cubic CrMnFeCoNi (Cantor) alloy, especially at cryogenic temperatures. In this work, we use a novel, modified dogbone geometry that allows the sampling of varying stress and strain regions within a single tensile specimen to characterize the onset of twinning in CrMnFeCoNi at 293 K, 198 K and 77 K. Electron backscatter diffraction (EBSD) and backscattered electron (BSE) imaging revealed the presence of deformation nano-twins in regions of the samples that had experienced plastic strains of ~25% at 293 K, ~16% at 198 K, and ~8% at 77 K, which are similar to the threshold strains described by Laplanche et al. ( Acta Mater. 118, 2016, 152–163). From these strains we estimate that the critical tensile stress for the onset of twinning in this alloy is on the order of 750 MPa.

36 MATERIALS SCIENCE↗

Fast-neutron multiplicity counter for active measurements of uranium oxide certified material

We developed a fast-neutron multiplicity counter (FNMC) based on stilbene and EJ-309 organic 11 scintillators. The system can detect and discriminate correlated photon and neutron multiplets emitted by fission 12 reactions. We used the system to estimate the fissile mass of uranium oxide samples in active interrogation mode at the 13 Zero Power Physics Reactor of Idaho National Laboratory (INL). Two sets of certified reference material (CRM) 14 samples were characterized. The U-235 enrichment of the first set is constant at 93.2 wt%, and the UO 2 mass ranges 15 between 0.5 and 4 kg. The second set includes samples of increasing enrichment (from 20 wt% to 97 wt%) and constant 16 UO 2 mass of 230 g. We used two AmLi sources to induce fission reactions in the samples. Despite the intense gamma17 ray background of the UO 2 and interrogating sources, the system could measure induced fission neutrons emerging from 18 the interrogated samples without additional shielding surrounding the sample and only relying on pulse shape 19 discrimination to classify neutron and gamma-ray pulses. Here, the overall neutron count rate and time-correlated counts are 20 well correlated with the sample fissile mass. We also proved that CRM samples can be used to build a calibration curve 21 to assay the U-235 mass of unknown samples of different mass, geometry and enrichment, with an average bias error of 22 8%, for U-235 mass higher than 390 g.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation between Active Center Structure and Enhanced Dioxygen Binding in Co(salen) Nanoparticles: Characterization by In Situ Infrared, Raman, and X-ray Absorption Spectroscopies

The structure and ligand environment of Co(salen) nanoparticles and unprocessed Co(salen) have been determined by the combined application of infrared, Raman, X-ray absorption near edge structure (XANES), and extended X-ray absorption fine structure (EXAFS) spectroscopies, and X-ray diffraction (XRD) experiments before and during interaction with O2. The Co(salen) nanoparticles were prepared by the precipitation with compressed antisolvent (PCA) technique using commercially obtained Co(salen) [denoted as unprocessed Co(salen)] as the parent compound. The unprocessed Co(salen) particles exist as dimer species with a square-pyramidal coordination geometry that display no measurable O2 binding at room temperature. In sharp contrast, the Co(salen) nanoparticles show near-stoichiometric O2 adsorption, as demonstrated by microbalance gas binding experiments. The spectroscopy results indicate the presence of CoII centers with distorted tetrahedral geometry in the Co(salen) nanoparticles with no evidence of metallic Co clusters, confirmed by the lack of Co-Co contributions at bonding distances in the EXAFS spectra and the presence of characteristic features of CoII in the XANES spectra. The EXAFS data also indicate that there are on average two Co-N and two Co-O bonds with a distance of 1.81 {+-} 0.02 and 1.90 {+-} 0.02 Angstroms, respectively, consistent with typical metal salen structures. Upon O2 binding on the Co(salen) nanoparticles, the XANES results indicate oxidation of the CoII to CoIII, consistent with the vibrational data showing new bands associated with oxygen species bonded to Co centers and the increase in the oxygen coordination number from 1.8 to 2.9 in the EXAFS data. The results indicate that the enhanced O2 binding properties of Co(salen) nanoparticles are related to the unique distorted tetrahedral geometry, which is not observed in the unprocessed samples that contain mainly dimers with square planar geometry. The results presented here provide a fundamental relationship between active center structure and properties of novel molecule-based nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Composition And Electrical Properties Of Dust From Tokamak Compass

In spite of the fact that fusion is a subject of the study for many years, there are still a lot of open questions. One of the interesting topics in fusion research is a presence of dust grains in reactors. In the paper, dust grains born in tokamak Compass are studied and compared with samples of a spherical geometry and well known composition. A unique experimental setup was used for investigations of charging properties of such grains and the SEM and EDX spectroscopy was applied for a study of grain composition. We focus on the secondary emission because this process plays a prominent role when a portion of energetic electrons is present in surroundings of a particular grain. It was shown that depending on the grain size and material, energetic electrons charge the grains to positive potentials comparable with the energy of impinging electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Complete Monte Carlo Simulation of Neutron Scattering Experiments

In the far past, it was not possible to accurately correct for the finite geometry and the finite sample size of a neutron scattering set-up. The limited calculation power of the ancient computers as well as the lack of powerful Monte Carlo codes and the limitation in the data base available then prevented a complete simulation of the actual experiment. Using e.g. the Monte Carlo neutron transport code MCNPX [1], neutron scattering experiments can be simulated almost completely with a high degree of precision using a modern PC, which has a computing power that is ten thousand times that of a super computer of the early 1970s. Thus, (better) corrections can also be obtained easily for previous published data provided that these experiments are sufficiently well documented. Better knowledge of reference data (e.g. atomic mass, relativistic correction, and monitor cross sections) further contributes to data improvement. Elastic neutron scattering experiments from liquid samples of the helium isotopes performed around 1970 at LANL happen to be very well documented. Considering that the cryogenic targets are expensive and complicated, it is certainly worthwhile to improve these data by correcting them using this comparatively straightforward method. As two thirds of all differential scattering cross section data of {sup 3}He(n,n){sup 3}He are connected to the LANL data, it became necessary to correct the dependent data measured in Karlsruhe, Germany, as well. A thorough simulation of both the LANL experiments and the Karlsruhe experiment is presented, starting from the neutron production, followed by the interaction in the air, the interaction with the cryostat structure, and finally the scattering medium itself. In addition, scattering from the hydrogen reference sample was simulated. For the LANL data, the multiple scattering corrections are smaller by a factor of five at least, making this work relevant. Even more important are the corrections to the Karlsruhe data due to the inclusion of the missing outgoing self-attenuation that amounts to up to 15%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic behavior of NiCu nanowire arrays: Compositional, geometry and temperature dependence

Arrays of Ni{sub 100−x}Cu{sub x} nanowires ranging in composition 0 ≤ x ≤ 75, diameter from 35 to 80 nm, and length from 150 nm to 28 μm have been fabricated by electrochemical co-deposition of Ni and Cu into self-ordered anodic aluminum oxide membranes. As determined by X-ray diffraction and Transmission Electron Microscopy, the crystalline structure shows fcc cubic symmetry with [111] preferred texture and preferential Ni or Cu lattice depending on the composition. Their magnetic properties such as coercivity and squareness have been determined as a function of composition and geometry in a Vibrating Sample Magnetometer in the temperature range from 10 to 290 K for applied magnetic fields parallel and perpendicular to the nanowires axis. Addition of Cu into the NiCu alloy up to 50% enhances both parallel coercivity and squareness. For the higher Cu content, these properties decrease and the magnetization easy axis becomes oriented perpendicular to the wires. In addition, coercivity and squareness increase by decreasing the diameter of nanowires which is ascribed to the increase of shape anisotropy. The temperature dependent measurements reflect a complex behavior of the magnetic anisotropy as a result of energy contributions with different evolution with temperature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantitative electron density characterization of soft tissue substitute plastic materials using grating-based x-ray phase-contrast imaging

Many scientific research areas rely on accurate electron density characterization of various materials. For instance in X-ray optics and radiation therapy, there is a need for a fast and reliable technique to quantitatively characterize samples for electron density. We present how a precise measurement of electron density can be performed using an X-ray phase-contrast grating interferometer in a radiographic mode of a homogenous sample in a controlled geometry. A batch of various plastic materials was characterized quantitatively and compared with calculated results. We found that the measured electron densities closely match theoretical values. The technique yields comparable results between a monochromatic and a polychromatic X-ray source. Measured electron densities can be further used to design dedicated X-ray phase contrast phantoms and the additional information on small angle scattering should be taken into account in order to exclude unsuitable materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A laboratory 8 keV transmission full-field x-ray microscope with a polycapillary as condenser for bright and dark field imaging

This article introduces a laboratory setup of a transmission full-field x-ray microscope at 8 keV photon energy. The microscope operates in bright and dark field imaging mode with a maximum field of view of 50 μm. Since the illumination geometry determines whether the sample is illuminated homogeneously and moreover, if different imaging methods can be applied, the condenser optic is one of the most significant parts. With a new type of x-ray condenser, a polycapillary optic, we realized bright field imaging and for the first time dark field imaging at 8 keV photon energy in a laboratory setup. A detector limited spatial resolution of 210 nm is measured on x-ray images of Siemens star test patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in high-resolution RIXS for the study of excitation spectra under high pressure

Hard x-ray resonant inelastic x-ray scattering (RIXS) is a promising x-ray spectroscopic tool for measuring low-energy excitation spectra at high pressure which have been stymied heretofore by the technical difficulties inherent in measuring a sample held at high pressure in a diamond anvil cell. The currently available facilities of high resolution (< 200 meV) RIXS has been used to probe low-energy excitation spectra from the diamond anvil cell, by virtue of advanced photon detection instrumentations of high-brilliance synchrotron x-ray radiation sources. Compared to a structural elastic scattering and x-ray emission, RIXS is a photon hungry technique and high-resolution RIXS under high pressure is at its infancy stage. In this review, the fundamentals of RIXS including instrumentation of high-resolution RIXS are presented and then experimental details of diamond anvil cell, sample preparation and measurement geometry are discussed. Experimental data of 3d and 5d transition metal oxides are presented. Finally, future improvements in high-resolution RIXS instrumentation for the high pressure experiment is discussed.

electronic and magnetic excitations↗

THE DIFFERENCES IN THE TORUS GEOMETRY BETWEEN HIDDEN AND NON-HIDDEN BROAD LINE ACTIVE GALACTIC NUCLEI

We present results from the fitting of infrared (IR) spectral energy distributions of 21 active galactic nuclei (AGNs) with clumpy torus models. We compiled high spatial resolution (∼0.3–0.7 arcsec) mid-IR (MIR) N-band spectroscopy, Q-band imaging, and nuclear near- and MIR photometry from the literature. Combining these nuclear near- and MIR observations, far-IR photometry, and clumpy torus models enables us to put constraints on the torus properties and geometry. We divide the sample into three types according to the broad line region (BLR) properties: type-1s, type-2s with scattered or hidden broad line region (HBLR) previously observed, and type-2s without any published HBLR signature (NHBLR). Comparing the torus model parameters gives us the first quantitative torus geometrical view for each subgroup. We find that NHBLR AGNs have smaller torus opening angles and larger covering factors than HBLR AGNs. This suggests that the chance to observe scattered (polarized) flux from the BLR in NHBLR could be reduced by the dual effects of (a) less scattering medium due to the reduced scattering volume given the small torus opening angle and (b) the increased torus obscuration between the observer and the scattering region. These effects give a reasonable explanation for the lack of observed HBLR in some type-2 AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

Establishing the structure of GeS{sub 2} at high pressures and temperatures : a combined approach using x-ray and neutron diffraction.

The change in structure of glassy GeS{sub 2} with pressure increasing to {approx_equal}5 GPa at ambient temperature was explored by using in situ neutron and x-ray diffraction. Under ambient conditions, the glass structure is made from a mixture of corner- and edge-sharing Ge(S{sub 1/2}){sub 4} tetrahedra where 47(5)% of the Ge atoms are involved in edge-sharing configurations. The network formed by these tetrahedra orders on an intermediate range as manifested by the appearance of a pronounced first sharp diffraction peak in the measured total structure factors at a scattering vector k = 1.02(2) {angstrom}{sup -1} which has a large contribution from Ge-Ge correlations. The intermediate range order breaks down when the pressure on the glass increases above {approx}2 GPa but there does not appear to be a significant alteration of the Ge-S coordination number or corresponding bond length with increasing density. The results for the glass are consistent with a densification mechanism in which there is a replacement of edge-sharing by corner-sharing Ge centered tetrahedral motifs and/or a reduction in the Ge-{cflx S}-Ge bond angle between corner-sharing tetrahedral motifs with increasing pressure. The change in structure with increasing temperature at a pressure of {approx_equal}5 GPa was also investigated by means of in situ x-ray diffraction as the glass crystallized and then liquefied. At 5.2(1) GPa and 828(50) K the system forms a tetragonal crystal, with space group I{bar 4}2d and cell parameters a = b = 4.97704(12) and c = 9.5355(4) {angstrom}, wherein corner-sharing Ge(S{sub 1/2}){sub 4} tetrahedra pack to form a dense three-dimensional network. A method is described for correcting x-ray diffraction data taken in situ under high pressure, high temperature conditions for a cylindrical sample, container and gasket geometry with a parallel incident beam and with a scattered beam that is defined using an oscillating radial collimator. A method is also outlined for obtaining coordination numbers from direct integration of the peaks in measured x-ray total pair distribution functions.

36 MATERIALS SCIENCE↗

hIPPYlib-MUQ: A Bayesian Inference Software Framework for Integration of Data with Complex Predictive Models under Uncertainty

Bayesian inference provides a systematic framework for integration of data with mathematical models to quantify the uncertainty in the solution of the inverse problem. However, the solution of Bayesian inverse problems governed by complex forward models described by partial differential equations (PDEs) remains prohibitive with black-box Markov chain Monte Carlo (MCMC) methods. We present hIPPYlib-MUQ, an extensible and scalable software framework that contains implementations of state-of-the art algorithms aimed to overcome the challenges of high-dimensional, PDE-constrained Bayesian inverse problems. These algorithms accelerate MCMC sampling by exploiting the geometry and intrinsic low-dimensionality of parameter space via derivative information and low rank approximation. The software integrates two complementary open-source software packages, hIPPYlib and MUQ. hIPPYlib solves PDE-constrained inverse problems using automatically-generated adjoint-based derivatives, but it lacks full Bayesian capabilities. MUQ provides a spectrum of powerful Bayesian inversion models and algorithms, but expects forward models to come equipped with gradients and Hessians to permit large-scale solution. By combining these two complementary libraries, we created a robust, scalable, and efficient software framework that realizes the benefits of each and allows us to tackle complex large-scale Bayesian inverse problems across a broad spectrum of scientific and engineering disciplines. To illustrate the capabilities of hIPPYlib-MUQ, we present a comparison of a number of MCMC methods available in the integrated software on several high-dimensional Bayesian inverse problems. These include problems characterized by both linear and nonlinear PDEs, various noise models, and different parameter dimensions. The results demonstrate that large (~ 50×) speedups over conventional black box and gradient-based MCMC algorithms can be obtained by exploiting Hessian information (from the log-posterior), underscoring the power of the integrated hIPPYlib-MUQ framework.

97 MATHEMATICS AND COMPUTING↗

Comparing optical four-flux model results with experimental data obtained by integrating sphere measurements

Four-flux theory is a way to model scattering through multiple layers of a system based on diffuse and collimated properties. When compared with measurement results obtained using an integrating sphere or a goniophotometer, an approximation is often made as the physical instrument cannot separate the collimated component from the diffuse light scattered in the forward direction. This paper tries to clarify the meaning of the word diffuse for the different cases and outlines simple corrections to improve the accuracy when comparing four-flux models and measured data based on sample haze and the geometry of the integrating sphere.

Bilokur, Maryna (ORCID:0000000191839650)↗

Non-destructive evaluation of specific surface area of porous powder systems using experimental and virtual air permeametry

The correlation of flow-permeable surface area (FSSA) of porous initiator powder to its performance is well-established. More specifically, with age, such powders tend to coarsen (i.e., lose surface area), with an accompanying deterioration in performance. Commercially available permeametry apparatuses, such as that from Fisher Scientific or a more modern version from Micromeritics suffers from a few drawbacks, including: (1) the need to work with a fixed mass equivalent of 1 cm 3 of solid material; (2) the need to re-compact the material to monitor aging effects (which can introduce unwanted errors in the derived results); (3) a superfluous design that involves a reference plug, and for the older Fisher Scientific model, the need to eyeball water meniscus height that can lead to inaccuracies; (4) calibrated and tested only for samples packed in cylindrical geometries.

36 MATERIALS SCIENCE↗