Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

High-resolution X-ray diffraction analysis of Al{sub x}Ga{sub 1−x}N/In{sub x}Ga{sub 1−x}N/GaN on sapphire multilayer structures: Theoretical, simulations, and experimental observations

The work presents a comparative study on the effects of In incorporation in the channel layer of AlGaN/GaN type-II heterostructures grown on c-plane sapphire by Plasma Assisted Molecular Beam Epitaxy. The structural characterizations of these samples were performed by High-Resolution X-Ray Diffraction (HRXRD), X-ray Reflectivity (XRR), Field Emission Scanning Electron Microscopy, and High Resolution Transmission Electron Microscopy. The two-dimensional electron gas in the AlGaN/GaN and AlGaN/InGaN interface was analyzed by electrochemical capacitance voltage and compared with theoretical results based on self-consistent solution of Schördinger–Poisson equations. The carrier profile shows enhanced confinement in InGaN channel (1.4393 × 10{sup 13} cm{sup −2} compared to 1.096 × 10{sup 13} cm{sup −2} in GaN). On the basis of HRXRD measurements, the stress-strain of the layers was examined. The c- and a-lattice parameters of the epilayers as well as in-plane and out-of plane strains were determined from the ω-2θ for symmetric scan and ω-Xθ (X represents the coupling coefficient) for asymmetric scan. Strain, tilt, and correlation lengths were calculated from Williamson–Hall plots, whereas stress was examined from modified plot of the same data assuming Uniform Stress Deformation Model. Moreover, the twist angle was measured from skew symmetric scan of (102), (103), and (105) plane along with (002) symmetric plane. The composition and strain/relaxation state of the epilayers were observed in detail by reciprocal space mapping (RSM). The symmetric (002) triple axis RSM and asymmetric (105 and 114) double axis RSM of grazing incidence and exit geometry were carried out on each sample. The defect density was measured from HRXRD curves of skew symmetric (002) and (102) reflection plane. The Al and In mole fraction and strain states of the layers were calculated by fitting the experimental curves with computer simulations and compared with theoretical findings based on elastic theory. The thicknesses of the layers and roughness of the interfaces were measured from simulation of the nominal structure by fitting with XRR experimental curves. The HRXRD measured thicknesses of the layers were further confirmed by cross sectional electron micrographs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Development of high-resolution x-ray CT system using parallel beam geometry

For fine three-dimensional observations of large biomedical and organic material samples, we developed a high-resolution X-ray CT system. The system consists of a sample positioner, a 5-μm scintillator, microscopy lenses, and a water-cooled sCMOS detector. Parallel beam geometry was adopted to attain a field of view of a few mm square. A fine three-dimensional image of birch branch was obtained using a 9-keV X-ray at BL16XU of SPring-8 in Japan. The spatial resolution estimated from the line profile of a sectional image was about 3 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of the Grazing Incidence Geometry on X-ray Photon Correlation Spectroscopy Measurements

X-ray photon correlation spectroscopy (XPCS) is a versatile tool to measure dynamics on the nanometer to micrometer scale in bulk samples. XPCS has also been applied in grazing incidence (GI) geometry to examine the dynamics of surface layers. However, considering GI scattering experiments more universally, the GI geometry leads to a superposition of signals due to reflection and refraction effects, also known from the distorted-wave Born approximation (DWBA). In this paper, the impact of these reflection and refraction effects on the correlation analysis is determined experimentally by measuring grazing incidence transmission XPCS (GT-XPCS) and grazing incidence XPCS (GI-XPCS) simultaneously for a thin film sample, showing non-equilibrium dynamics. Here the results of the GI and GT geometry comparisons are combined within the framework of the standardly applied, simplified DWBA. These calculations allow identifying the main contributions of the detected signal from the leading scattering terms along the out-of-plane direction q z , which dominate the measured intensity pattern on the detector. In combination with the calculation of the non-linear effect of refraction in GTSAXS and GISAXS, it is possible to identify experimental conditions that can be chosen to run experiments and data analysis as close as possible to transmission XPCS and to explain which limitations for data interpretations are observed. Consequently, the beam exposure can be significantly reduced by using GI geometry only. Calculations of experimental settings prior to experiments are detailed to determine suitable q z regions for a variety of material systems measured in bulk-sensitive GI-XPCS experiments, allowing us to determine the scaling behavior of typical decay times as a function of q that is comparable to the scaling behavior obtained in distortion-free GT-XPCS or transmission XPCS experiments.

36 MATERIALS SCIENCE↗

Dosimetric measurements of an n-butyl cyanoacrylate embolization material for arteriovenous malformations

Purpose: The therapeutic regimen for cranial arteriovenous malformations often involves both stereotactic radiosurgery and endovascular embolization. Embolization agents may contain tantalum or other contrast agents to assist the neurointerventionalists, leading to concerns regarding the dosimetric effects of these agents. This study investigated dosimetric properties of n-butyl cyanoacrylate (n-BCA) plus lipiodol with and without tantalum powder. Methods: The embolization agents were provided cured from the manufacturer with and without added tantalum. Attenuation measurements were made for the samples and compared to the attenuation of a solid water substitute using a 6 MV photon beam. Effective linear attenuation coefficients (ELAC) were derived from attenuation measurements made using a portal imager and derived sample thickness maps projected in an identical geometry. Probable dosimetric errors for calculations in which the embolized regions are overridden with the properties of water were calculated using the ELAC values. Interface effects were investigated using a parallel plate ion chamber placed at set distances below fixed samples. Finally, Hounsfield units (HU) were measured using a stereotactic radiosurgery CT protocol, and more appropriate HU values were derived from the ELAC results and the CT scanner’s HU calibration curve. Results: The ELAC was 0.0516 ± 0.0063 cm{sup −1} and 0.0580 ± 0.0091 cm{sup −1} for n-BCA without and with tantalum, respectively, compared to 0.0487 ± 0.0009 cm{sup −1} for the water substitute. Dose calculations with the embolized region set to be water equivalent in the treatment planning system would result in errors of −0.29% and −0.93% per cm thickness of n-BCA without and with tantalum, respectively. Interface effects compared to water were small in magnitude and limited in distance for both embolization materials. CT values at 120 kVp were 2082 and 2358 HU for n-BCA without and with tantalum, respectively; dosimetrically appropriate HU values were estimated to be 79 and 199 HU, respectively. Conclusions: The dosimetric properties of the embolization agents are very close to those of water for a 6 MV beam. Therefore, treating the entire intracranial space as uniform in composition will result in less than 1% dosimetric error for n-BCA emboli smaller than 3.4 cm without added tantalum and n-BCA emboli smaller than 1.1 cm with added tantalum. Furthermore, when effective embolization can be achieved by the neurointerventionalist using n-BCA without tantalum, the dosimetric impact of overriding material properties will be lessened. However, due to the high attenuation of embolization agents with and without added tantalum for diagnostic energies, artifacts may occur that necessitate additional imaging to accurately identify the spatial extent of the region to be treated.

07 ISOTOPE AND RADIATION SOURCES↗

Validated ligand geometries for macromolecular refinement restraints and molecular-mechanics force fields

In macromolecular structure refinement, the low observation-to-parameter ratio and the lack of high-resolution data are countered by using a priori information in the form of restraints. Having accurate geometries of the chemical entities in the sample is paramount for generating accurate chemical restraints and, therefore, accurate macromolecular structures. In particular, it is desirable to have accurate restraints for known and novel ligand entities. Quantum mechanics (QM) can minimize the energy of a ligand by adjusting its geometry, and these geometries can be used to generate restraints for macromolecular refinement. This article describes a library of approximately 37 000 small molecules extracted from the Chemical Component Dictionary in the Protein Data Bank and minimized by density-functional QM. The library includes restraint files for use in crystallography or cryo-EM refinement, along with files suitable for molecular-dynamics simulation. Because the geometries are validated using the Cambridge Structural Database, the restraints library provides users with both functional restraints and minimized geometries. This work also provides procedures for generating new and accurate restraints.

Amber↗

Effect of Shear Displacement and Stress Changes on Fracture Hydraulic Aperture and Flow Anisotropy

Fluid flow in fractures has the potential to drastically change the economic, environmental, and safety risks associated with a subsurface operation. This work focuses on the analysis of experimental shear fracturing and subsequent shear displacement of a shale specimen that contains multiple pre-existing natural fractures. A triaxial direct shear apparatus with concurrent µCT imaging allowed continuous monitoring of sample permeability and changes in fracture geometry during fracture creation, displacement, and changes in stress. Steady-state, low Reynolds number fluid flow simulations were used to determine the changes of each individual fracture’s hydraulic aperture due to displacement and effective stress. The development of anisotropy in the hydraulic aperture of a generated shear fracture was determined for shear displacements of 0.38, 0.74, and 2.04 mm. At high confining stress (30 MPa), shear displacement significantly reduced the hydraulic aperture of the shear fracture to below flow detectable limits and X-ray imaging resolution (23 × 23 × 23 µm 3 ). The shear generated fracture was found to be more sensitive to changes in effective stress compared to the pre-existing natural fractures. Existing models derived from fluid flow equations accounting for stochastic fracture roughness were able to partially fit the simulated flow properties of the pre-existing fractures, but no model was found to fit the flow properties of the newly formed shear fracture. These results are the first report of simultaneous changes in the geometry and flow properties of surrounding, parallel natural fractures as a shear fracture is generated with varying stress and shear displacement conditions.

58 GEOSCIENCES↗

Toward Molecule-Specific Geochemistry of Heavy Ends: Application to the Upstream Oil Industry

Detailed molecular analysis of the composition of petroleum is typically performed on only the light (volatile) fraction, using analyses involving gas chromatography (GC). Heavier (nonvolatile) components such as kerogen, bitumen, and asphaltenes, which are relevant to conventional reservoirs and particularly to unconventional gas shale and tight oil formations, are not amenable to analysis by GC and instead are typically studied by more phenomenological techniques. This report describes a suite of analytical techniques that can provide sufficient average molecular information on the heavy ends (defined as the nonvolatile fraction) to be useful for a variety of industrial applications, expanding the discipline of molecule-specific geochemistry into the non-GC amenable fractions of petroleum materials. Heavy ends are composed of the elements C, H, N, S, and O, and the bonding environments of each can be measured by various solid state spectroscopies: nuclear magnetic resonance (NMR) and infrared (IR) spectroscopies for C, H, and O; X-ray absorption near-edge structure (XANES) spectroscopy for S and N. Additionally, advances in mass spectrometry, including techniques such as laser desorption laser ionization mass spectrometry (L2MS), can be used to measure the molecular weight and dominant molecular architecture of asphaltenes. Moreover, higher-order structures can be measured: samples of kerogen with representative pore geometry can be prepared, and those pore systems are analyzed with techniques such as X-ray diffraction and neutron scattering. Colloidal structures of asphaltenes can be measured with a variety of techniques, which reveal a hierarchical aggregation structure. These analyses provide sufficient structural data to enable structure–property and structure–function relationships to be determined, which can be applied to the characterization of conventional and unconventional resources. In gas shale and tight oil formations, which contain abundant inorganic minerals as well as kerogen, diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) is used for simultaneous analysis of mineralogy, kerogen content, and maturity, typically performed at the wellsite. In conventional reservoirs, spatial variations in the asphaltene concentration measured by downhole fluid analysis logging tools are being interpreted with a recently developed equation of state to address upstream issues such as reservoir connectivity, tar mat formation, and fault block migration. Furthermore, as more heavy end analyses are developed, further scientific knowledge and industrial applications of heavy end geochemistry are anticipated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting the X-ray Absorption Spectrum of Ozone with Single Configuration State Functions

X-ray absorption spectra (XAS) of biradicaloid species are often thought to represent a challenge to theoretical methods. This has led to the testing of recently developed multireference techniques on the XAS of ozone, but reproduction of the experimental spectral profile has proven difficult. We utilize a minimal model consisting of a single configuration state function (CSF) per excited state to model core-level excitations of ozone, with the orbitals of each CSF optimized using the restricted open-shell Kohn–Sham (ROKS) method. This protocol leads to semiquantitative agreement with experimental XAS. In fact, we find that low-lying core-hole excited states in biradicaloids can be approximated with individual CSFs, despite the presence of multireference character in the ground state. Here, we also report that the 1s → π* and 1s → σ* transitions have quite distinct widths for O 3 . This reveals the importance of sampling over a representative range of geometries from the vibrational ground state for properly assessing the accuracy of electronic structure methods against experiments instead of the popular procedure of uniformly broadening stick spectra at the equilibrium geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broadband Wide-Angle VElocity Selector (BWAVES) neutron spectrometer designed for the SNS Second Target Station

A recently proposed wide-angle velocity selector (WAVES) device for choosing the velocity of detected neutrons after they have been scattered by the sample paves the way for inverted geometry neutron spectrometers with continuously adjustable final neutron wavelength. BWAVES broadband inverted geometry spectrometer proposed for the Second Target Station at the Spallation Neutron Source at Oak Ridge National Laboratory is designed using WAVES to simultaneously probe dynamic processes spanning 4.5 decades in time (energy transfer). This makes BWAVES a uniquely flexible instrument which can be viewed as either a quasielasitc neutron scattering (QENS) spectrometer with a practically unlimited (overlapping with the vibrational excitations) range of energy transfers, or a broadband inelastic vibrational neutron spectrometer with QENS capabilities, including a range of accessible momentum transfer (Q) and a sufficiently high energy resolution at the elastic line. The new capabilities offered by BWAVES will expand the application of neutron scattering in ways not possible with existing neutron spectrometers.

36 MATERIALS SCIENCE↗

A fully coupled thermal–microstructural–mechanical finite element process model for directed energy deposition additive manufacturing of Ti–6Al–4V

A fully coupled thermal–microstructural–mechanical finite element modelling framework is developed to investigate the distortion and residual stresses during directed energy deposition (DED) of multi-phase Ti–6Al–4V alloy. The Johnson–Cook constitutive model is used to predict the yield strength of each phase as a function of strain, strain rate and temperature where the flow stress is calculated by a linear mixing rule based on the volumetric phase fractions. A thin-walled rectangular sample is chosen as the reference geometry and the results are compared with experimentally measured in situ thermal history and distortion data, where a reasonable agreement is achieved. The proposed modelling framework with physics-based material constitutive model provides useful information for a better understanding of process–microstructure–property relations in additive manufacturing by DED.

Tunay, Merve↗

About a method for compressing X-ray computed microtomography data

The management of scientific data is of high importance especially for experimental techniques that produce big data volumes. Such a technique is x-ray computed tomography (CT) and its community has introduced advanced data formats which allow for better management of experimental data. Rather than the organization of the data and the associated meta-data, the main topic on this work is data compression and its applicability to experimental data collected from a synchrotron-based CT beamline at the Elettra-Sincrotrone Trieste facility (Italy) and studies images acquired from various types of samples. This study covers parallel beam geometry, but it could be easily extended to a cone-beam one. The reconstruction workflow used is the one currently in operation at the beamline. Contrary to standard image compression studies, this manuscript proposes a systematic framework and workflow for the critical examination of different compression techniques and does so by applying it to experimental data. Beyond the methodology framework, this study presents and examines the use of JPEG-XR in combination with HDF5 and TIFF formats providing insights and strategies on data compression and image quality issues that can be used and implemented at other synchrotron facilities and laboratory systems. In conclusion, projection data compression using JPEG-XR appears as a promising, efficient method to reduce data file size and thus to facilitate data handling and image reconstruction

data compression↗

Development and Understanding of Nb 3 Sn films for radiofrequency applications through a sample-host 9-cell cavity

Nb 3 Sn is a promising advanced material under development for superconducting radiofrequency cavities. Past efforts have been focused primarily on small development-scale cavities, but large, often multi-celled cavities, are needed for particle accelerator applications. In this work, we report on successful Nb 3 Sn coatings on Nb in a 1 m-long 9-cell Nb sample-host cavity at Fermilab. The geometry of the first coating with only one Sn source made it possible to study the influence of Sn flux on the microstructure. Based on these results, we postulate a connection between recently observed anomalously large thin grains and uncovered niobium spots observed in the past by other authors (Trenikhina et al 2018 Supercond. Sci. Technol. 32 015004). A phenomenological model to explain how these anomalously large grains could form is proposed. Overall, this model is invoked to provide possible explanations for literature results from several groups and to guide key process parameters to achieve uniform vapor-diffusion coatings, when applied to complex structures as the multi-cell cavity under study.

43 PARTICLE ACCELERATORS↗

FIRST MAGNETIC FIELD MODELS FOR RECENTLY DISCOVERED MAGNETIC {beta} CEPHEI AND SLOWLY PULSATING B STARS

In spite of recent detections of magnetic fields in a number of {beta} Cephei and slowly pulsating B (SPB) stars, their impact on stellar rotation, pulsations, and element diffusion has not yet been sufficiently studied. The reason for this is the lack of knowledge of rotation periods, the magnetic field strength distribution and temporal variability, and the field geometry. New longitudinal field measurements of four {beta} Cephei and candidate {beta} Cephei stars, and two SPB stars were acquired with FORS 2 at the Very Large Telescope. These measurements allowed us to carry out a search for rotation periods and to constrain the magnetic field geometry for four stars in our sample.

79 ASTRONOMY AND ASTROPHYSICS↗

The completed SDSS-IV extended baryon oscillation spectroscopic survey: geometry and growth from the anisotropic void–galaxy correlation function in the luminous red galaxy sample

ABSTRACT We present an analysis of the anisotropic redshift-space void–galaxy correlation in configuration space using the Sloan Digital Sky Survey extended Baryon Oscillation Spectroscopic Survey (eBOSS) Data Release 16 luminous red galaxy (LRG) sample. This sample consists of LRGs between redshifts 0.6 and 1.0, combined with the high redshift z > 0.6 tail of the Baryon Oscillation Spectroscopic Survey Data Release 12 CMASS sample. We use a reconstruction method to undo redshift-space distortion (RSD) effects from the galaxy field before applying a watershed void-finding algorithm to remove bias from the void selection. We then perform a joint fit to the multipole moments of the correlation function for the growth rate fσ8 and the geometrical distance ratio DM/DH, finding $f\sigma _8(z_\rm {eff})=0.356\pm 0.079$ and $D_M/D_H(z_\rm {eff})=0.868\pm 0.017$ at the effective redshift $z_\rm {eff}=0.69$ of the sample. The posterior parameter degeneracies are orthogonal to those from galaxy clustering analyses applied to the same data, and the constraint achieved on DM/DH is significantly tighter. In combination with the consensus galaxy BAO and full-shape analyses of the same sample, we obtain fσ8 = 0.447 ± 0.039, DM/rd = 17.48 ± 0.23, and DH/rd = 20.10 ± 0.34. These values are in good agreement with the ΛCDM model predictions and represent reductions in the uncertainties of $13{{\ \rm per\ cent}}$, $23{{\ \rm per\ cent}}$, and $28{{\ \rm per\ cent}}$, respectively, compared to the combined results from galaxy clustering, or an overall reduction of 55 per cent in the allowed volume of parameter space.

Nadathur, Seshadri↗