Development of Process for Cleanup of Sodium-CO 2 Reaction Products

This study describes Argonne’s recent experience in cleaning several kilograms of sodium mixed with solid reaction products formed bysodium-CO 2 interaction. One of the reaction products is carbon monoxide (CO) and precautions have to be taken to protect personnel from exposure to CO. Ethanol was an effective method to clean and dispose of small amounts of residual reaction products embedded in a sodium matrix. Ideally, the residual sodium should be melted out of the parts as possible in order to reduce the amount of time it would take to clean with ethanol since this process is slow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Brayton Cycles Utilizing Supercritical Carbon Dioxide

This white paper documents a detailed and extensive Brayton cycle analysis that was performed to better understand at a fundamental level the dependence of the Brayton cycle performance on operating conditions, working fluid, supercritical fluid properties, and some cycle non-idealities. This work was performed to better understand the factors controlling Brayton cycle performance and optimal operating conditions, particularly for cycles utilizing supercritical CO 2 (sCO 2 ) as the working fluid. The focus of this study is on cycle performance, particularly efficiency. No cost estimates were performed. However, as a single indirect measure of cycle cost, some sensitivity analyses on specific power (net output divided by working fluid mass flow rate) were included.

42 ENGINEERING↗

sCO 2 Cycle Analysis – Preliminary Results

This is a presentation on a '10 MWe sCO 2 Demo analysis'. The sCO 2 cycle modeled is a Recompression Brayton Cycle. A baseline cycle is base on a series of parameters that were assumed as reasonable from preliminary runs and know literature values. Sensitivities to key parameters were then made. These included pressure ratio, system pressure drop, minimum recuperator temperature approach., and turbine inlet temperature. The idea of cost surrogate variables is also introduced.

42 ENGINEERING↗

Techno-economic Evaluation of Utility-Scale Power Plants Based on the Indirect sCO 2 Brayton Cycle - Report

This report presents the results of a techno-economic analysis (TEA) of a coal-fired utility scale power plant based on the indirect supercritical carbon dioxide (sCO 2 ) Brayton cycle using an oxy-fired circulating fluidized bed (CFB). A baseline plant configuration was examined as well as three variations to the sCO 2 power cycle examining the impact of reheat (Rht), main compressor intercooling (IC), and a combination of reheat and main compressor intercooling (RhtIC). Each plant configuration was assessed at two turbine inlet temperatures of 620 °C and 760 °C.

20 FOSSIL-FUELED POWER PLANTS↗

Initial Argonne Sodium Draining Tests: Analysis of Test Results and Comparison with Water Draining Behavior

Three initial sodium draining experiments have been carried out in which sodium was drained from a 0.46 m high 4.6 mm inner diameter vertical stainless steel tube wetted by the sodium representative of a sodium channel in a compact diffusion-bonded sodium-to-CO 2 heat exchanger. Prior to the startup of sodium testing, shakedown tests were conducted with water. In all three sodium experiments, the sodium drained efficiently from the channel. Sodium and water both drain efficiently from a 4.6 mm inner diameter vertical stainless steel tube. This is an important and good result for the design of compact diffusion-bonded heat exchanger sodium channels. Sodium drains more efficiently than water. This is also an important and good result for the design of compact diffusion-bonded heat exchanger sodium channels. The draining phenomena observed with sodium and water are significantly different. The draining of water involves an initial rapid slug draining phase followed by a linear rate draining phase followed by a slow draining phase involving draining of rivulets and drops. This behavior has previously been reported in the literature for viscous fluids. The draining of sodium involves an initial rapid slug draining phase but no discernable linear rate draining phase. There is a subsequent slow draining phase. However, unlike the slow draining phase with water that involves a number of rivulets and drops, the slow draining phase with sodium in two out of three sodium tests mainly involves a single discrete event in which a mass of sodium drains from the tube. This single discrete draining event encompasses most of the sodium mass remaining inside of the tube following the rapid slug draining phase. The existence of a single discrete draining event during the slow draining phase with sodium versus several rivulet and drop draining events with water is thought to simply reflect the fact that significantly lower mass fractions of liquid are left behind inside of the tube following the rapid slug draining phase with sodium relative to water. For the sodium tests, the progress of wetting of the stainless steel by sodium was monitored by means of the voltage drop across the tube outer diameter measured by pairs of opposing electrodes welded to the tube outer surface at three different elevations. The electrode data remarkably reveals phenomena during the sodium draining. The downward passage of the sodium slug trailing edge past each electrode was observed from which a mean slug trailing edge velocity could be determined. The subsequent slower increase in voltage drop suggests draining and thinning of a sodium film left behind upon the tube inner surface; wiggles in the voltage drop data are suggestive of the descent of waves on the film. It is thought that the draining sodium film collects as a mass likely near the lower end of the tube and detaches corresponding to the single discrete draining event observed in the load cell data. The minimum circular channel inner diameter for the draining of water and sodium without the formation of lenses that bridge the channel and may remain inside of the tube without draining is predicted with a correlation to be 2.2 mm. The highest priority for future sodium draining testing is to investigate other channel geometries such as a rectilinear channel or a semicircular channel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY 2017 Progress Report on the Argonne Sodium Draining and Refilling Experiments

The main incentive for utilization of compact diffusion-bonded sodium-to-CO 2 heat exchangers for a Sodium-Cooled Fast Reactor (SFR) with a supercritical carbon dioxide ( s CO 2 ) Brayton cycle power converter is the potential for reduction in heat exchanger size and cost relative to traditional shell-and-tube technology. There is an incentive for the designer to reduce the width of the sodium and CO 2 channels as much as possible to realize the greatest size and cost reductions. However, there are practical limits on minimum channel size due to fundamental phenomena particular to sodium and CO 2 . One is that the channel size must be large enough to enable the rapid draining of sodium from the heat exchanger sodium channels in the event that a sodium leak is detected in an intermediate sodium heat transport system loop, in order to rapidly drain the sodium into the loop sodium storage vessel/tank and thereby limit the sodium mass released that could potentially burn if exposed to air. Information about the minimum sodium channel size can only be obtained by actually draining sodium from representative wetted stainless steel sodium channels under prototypical conditions. It is not possible to obtain such information through modeling and simulation or through simulant experiments. The ANL Sodium Draining and Refilling experiment facility has been designed and is being assembled to obtain data on the draining of sodium from compact diffusion-bonded sodium-to-carbon dioxide heat exchanger sodium channels including the mass of sodium drained versus time, the mass of sodium retained inside of the channels, and the potential for sodium to bridge the channel, freeze, and form a plug inside the channel versus the channel size. This information is needed to determine the minimum sodium channel size required to meet the requirements for sodium draining without bridges being left inside of the channels. Initial shakedown testing has been initiated using water and glass and plastic tubes before transitioning to sodium and stainless steel test sections. For the latter, the test sections will be heated to high temperature to promote rapid sodium wetting of the stainless steel prior to draining. Testing with sodium will be initiated in FY 2018.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Project: Enabling Technologies for Oxy-fired Pressurized Fluidized Bed Combustor Systems (Final Project)

GTI and team members CanmetENERGY and Linde worked on developing technologies at the pilot-scale to significantly improve the performance and economics of current oxy-fired pressurized fluidized bed combustor systems and reduce scale up risk. The technologies include: an In-bed Supercritical CO 2 (SCO 2 ) Heat Exchanger, the objective being to quantify SCO 2 heat transfer coefficients and pressure drop in an Oxygen-fired pressurized fluidized bed combustor (Oxy-PFBC) environment to anchor design rules for scale up; Staged Coal Combustion, the objective being to develop design rules for placement of staged coal combustion injectors to appropriately distribute heat throughout the bed to maintain an oxidizing environment and avoid slagging; and an Isothermal Deoxidation Reactor, the objective being to define operational limits on flue gas O 2 concentration for an isothermal catalyst bed and demonstrate heat recovery from this deoxidation unit. In-bed SCO 2 heat exchanger manifolds were successfully manufactured and installed in the combustor at CanmetENERGY. Staged fuel injectors were designed and fabricated. A task to test an oxygen carrier in the fluidized bed was also planned. A Quasi-Isothermal Deoxidation Reactor (Q-IDR) concept was developed and fabricated, consisting of two adiabatic catalytic reactors with a single inter-stage cooler with SCO 2 as the coolant. The project was stopped prior to testing these technologies due to damage to the hardware on the related Oxy-PFBC Phase II project (DE-FE0009448).

20 FOSSIL-FUELED POWER PLANTS↗

Supercritical Carbon Dioxide Primary Power Large-Scale Pilot Plant

The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO 2 ) large-scale pilot. This transformational technology uses sCO 2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO 2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO 2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO 2 can offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO 2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO 2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO 2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO 2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system.

01 COAL, LIGNITE, AND PEAT↗

Ultra High-Temperature Magnetic Bearing System for s-CO 2 Turbines/Expanders. Phase II Final Report

The goal of this project is to design and construct of a prototype of ultra-high temperature permanent magnet (UHT–PM), which provides the force to pull the spinning shaft towards the target position in the magnetic bearing (MB) clearance circle. This project will develop a PM biased MB system, that is actively cooled to the 550°C maximum operating temperature limit of PMs. The MB test environment will include 700°C, 40krpm and 4,000 psi requirements to advance the supercritical carbon dioxide (sCO 2 ) and other types of Brayton power cycle systems. The proposed novel MBs combine PMs for supplying the bias field and electromagnets for supplying the control field, both in UHT conditions. The choice of material is the UHT Sm-Co PMs (US patent 6,451,132) due to their significantly better thermal stability. The 6-pole homopolar design permits uninterrupted force delivery via a redundant control capability (US patent 7,429,811) even if 3 poles were to fail. The Phase I efforts was to focus on development and demonstration of component technologies and detailed design of full scale components and a demonstrator test rig for use in Phase II. UHT–PMs were produced and used in the MB actuator. The operating environment of the EEC-T550 Sm-Co magnet material could be extended by implementing active cooling. Electromagnetic coils imbedded in the MB provide forces to stabilize the shaft position at the target via sensing and control stages. Shaft position sensors enable to identify the present position of the spinning shaft relative to its desired target position in the MB clearance circle (air gap). Auxiliary bearings will be installed to provide a backup support system in the event that power to the MB fails or there is a fault in a device providing current to the MB coils. For control, reliability and safety reasons the sensors and auxiliary bearings are typically located as close as possible to the MBs, which exposes them to the same environmental conditions. Development of only the actuator for the UHT environment is an inadequate approach to complete integration of the MB system in the turbine/expander. Therefore the UHT sensor and auxiliary bearing were designed and developed along with the actively cooled, UHT-PM actuator development. Although shaft position sensors are commercially available (Kaman) they may cost up to $10k per channel, and a full 5 axis magnetic suspension is best implemented with up to 20 sensors. Once successfully completed, this project will significantly extend the operating environment capability for turbomachinery applications such as nuclear power, concentrated solar thermal, fossil fuel, geothermal, and shipboard propulsion. The further advancement of UHT-PM-MB will also strengthen the US position in PM technology, which is presently heavily dominated by China. The UHT Sm-Co magnet material that will be utilized in the proposed work has been developed exclusively by the project proposer. Many actuators, motors, generators and other MB applications will greatly benefit from the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovative Method for Welding in Generation 3 CSP to Enable Reliable Manufacturing of Solar Receivers to withstand Daily Cycling at Temperatures Above 700°C (Final Technical Report)

Inconel® Alloy 740H® (alloy 740H) was the first age-hardenable nickel-based alloy approved by the ASME Boiler & Pressure Vessel Code for use in pressure-boundary applications. Over the past ~20 years the alloy has been optimized for weldability and high-temperature stability, approved for use in different applications. Development of a supply chain combined with the advantageous properties of the alloy (high-temperature creep strength, oxidation and corrosion resistance, etc.) have resulted in the alloy being applied to new high-temperature power cycle demonstration projects, and of particular interest are applications to concentrating solar power (CSP) to enable higher-efficiency Generation 3 CSP systems and the corresponding supercritical CO 2 (sCO 2 ) power cycle components (heat exchangers, piping, etc.). The high allowable stresses of alloy 740H also make it a desirable material for current Generation 2 CSP solar power receivers to improve cyclic capability and/or reduce receiver height. Recent experiences in demonstration projects utilizing alloy 740H identified cracking issues during welding and fabrication. In this project, a detailed study was done to confirm and clarify the Stress Relaxation Cracking (SRxC) mechanism, also known as stress relief cracking or strain-age cracking (SAC), during post-weld heat-treatment (PWHT). This involved detailed microscopy and advanced characterization to understand the root cause(s) of three failures obtained from industry. Based in-part on these findings, a targeted laboratory based SRxC test method was utilized to evaluate variables such as heat-to-heat variations, strain level, PWHT temperature, and starting material condition on three heats of alloy 740H. Industrial shop welding of cold-worked plates was also conducted. The research showed the following: SRxC was confirmed as the cracking mechanism for all field failures; Stress state (from residual stresses, constraint, deformation, and local stress concentrations) was playing a significant role in field failures and laboratory testing confirmed increasing susceptibility for all heats with increasing strain levels. High levels of microstructural strain were identified at crack initiation locations, in some cases leading to local recrystallization; Precipitate free zones (PFZs) at grain boundaries were found at relaxation cracks and crack initiation locations uniquely associated with SRxC in alloy 740H. Laboratory testing reproduced this microstructural feature which had only previously been reported in long-term creep testing of weldments. Advanced nano-scale characterization confirmed the presence of a moving boundary leading to coarsening of precipitates and PFZs where damage accumulated; The research suggested heat-to-heat variations due to local chemistry and processing may influence SRxC susceptibility, but more work is needed to fully clarify these effects. To disseminate the key learnings from this research to the scientific and engineering communities and alloy 740H end users, multiple technical publications and presentations were made, an industrial alloy 740H users meeting was held, and a new industry guideline specification document which can be directly implemented by end-users of alloy 740H was produced.

14 SOLAR ENERGY↗

High Inlet Temperature Combustor for Direct-Fired Supercritical Oxy-Combustion

It is envisioned that supercritical CO 2 (sCO 2 ) electric power plant efficiencies can exceed 52% with 99% carbon capture using direct-fired oxy-combustion. Such efficiencies would be competitive with Natural Gas Combined Cycles (NGCC) and operate with nearly zero carbon emissions. To achieve high plant efficiencies, turbine inlet conditions must approach 1,200 °C at 250 bar. Such conditions, while desirable from a systems perspective, exceed the current state of the art in turbine design and materials qualification. The team of Southwest Research Institute ® (SwRI ® ), Georgia Institute of Technology (Georgia Tech), Spectral Energies, LLC (Spectral), GE Global Research (GE-GRC), and the University of Central Florida (UCF) sought to demonstrate an intermediate step toward these high efficiency plants with the development of a 1 MWth, subscale direct-fired oxy-fuel combustor. The efforts focused largely on the development of an auto-ignition based combustion system capable of providing the targeted 1200 °C and the pilot-scale plant to operate the combustor. While the project was stopped short of the commissioning and demonstration work, the advances made in this effort will reduce risks associated with chemical kinetics, thermal management, water separation, flue gas cleanup, materials selection, and corrosion in future demonstration efforts for the direct-fired oxy-fuel combustion cycles. The following report documents the design, analysis, and installation efforts completed during the project periods of performance.

03 NATURAL GAS↗

Low‐cost, Long Duration Electrical Energy Storage Using a CO 2 ‐based Pumped Thermal Energy Storage

The increasing deployment of non‐dispatchable, intermittent renewable energy generation sources to address climate change is placing pressure upon electrical grids’ ability to match supply with demand. The need to deploy large quantities of long duration energy storage assets is rapidly approaching, and innovative methods of energy storage that are low cost, efficient, safe and environmentally benign are needed urgently. CO 2 ‐based Pumped Thermal Energy Storage (PTES) is a low cost, efficient and environmentally safe energy storage technology. PTES uses an electrically‐driven CO 2 heat pump to charge thermal reservoirs that are later used as resources to generate electricity using a CO 2 heat engine. In this program, Echogen and collaborators refined the design of a utility‐scale CO 2 PTES system and demonstrated key technologies that will be required for successful commercial development in a laboratory‐scale system. Component and system‐level performance was evaluated over multiple charge/discharge cycles, with favorable results. Echogen is continuing to develop and commercialize this technology at utility scale.

25 ENERGY STORAGE↗

Heat Transfer of Supercritical Carbon Dioxide in 3D-Printed Tubes with Internal Ribs and Yttria Stabilized Zirconia Coating

This technical report describes measurements performed in NETL’s Heat Exchanger Experimental Test (HEET) facility using supercritical carbon dioxide as the working fluid. 3D printed tubes with internal ribs and yttria stabilized zirconia (YSZ) exterior coatings were employed in the heat exchanger. Heat transfer and friction factor enhancements from the internal ribs were characterized over a range of flow conditions. Additionally, the thermal resistance from the YSZ coating was characterized for both a freshly applied coating and a coating subjected to thermal aging.

36 MATERIALS SCIENCE↗

Technologies for Enhanced Condensation in sCO 2 Power Cycles

The direct fired supercritical carbon dioxide power cycle has higher efficiency, compact machinery footprint, and is resilient under transient operation. It has been shown that improving the cycle main cooler significantly improves performance, including increased cycle efficiency, decreased cost of electricity and decreased cooler outlet temperatures. One way to improve this process is through enhanced condensation techniques and management of condensation fluid. This manuscript provides an overview of active and passive enhanced condensation technologies, with a focus on the passive approaches. compared to passive approaches, active approaches can have higher heat transfer enhancement, but the additional power and infrastructure can be problematic. The passive approaches identified include microfins (helical and herringbone), corrugated tubing, dimpled tubing and pin fins. After comparison it is found that the microfin geometry has the best performance characteristics followed by the additively manufactured pin fins. It is noted that current literature around additively manufactured enhancements is lacking, and investigation of conventional as well as novel geometries fabricated in this manner may be worth further investigation. Benchmark correlations for these geometries are identified and their limitations outlined. For further investigation, a matrix of test articles is presented for possible experimentation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Inlet Guide Vane Performance for Discharge Compressor Operation near the Dome of an sCO 2 Pumped Heat Energy Storage

Southwest Research Institute® (SwRI®) developed and tested a Variable Inlet Guide Vane (IGV herein) assembly on an integrally-geared sCO 2 compressor (IGC) to demonstrate compressor operation at both the compressor design point and near the dome and to define the operating limits of the compressor by monitoring for two-phase flow, flow turbulence from the IGVs, and compressor choke and surge as the CO 2 inlet temperature is varied. Performance testing was conducted on an existing integrally-geared, two-stage main compressor designed for near-critical-point operation with CO 2 . This testing campaign validated the IGV design and operation, as well as improved the understanding and confidence in operating compressors and predicting performance characteristics near the critical point where fluid properties change rapidly with temperature. In addition to improving the robust operating limits of an sCO 2 compressor, the development of an IGV for the IGC system improved off-design compressor efficiency by 12%.

25 ENERGY STORAGE↗

Novel Modular Heat Engines with sCO 2 Bottoming Cycle Utilizing Advanced Oil-Free Turbomachinery

This report presents the thermal, mechanical, and electric machine design of a 27krpm rotating test rig aimed at reducing technical risks with hermetic oil-free super-critical carbon dioxide (sCO 2 ) turbomachinery. The test rig rotor system is based on a conceptual turbomachine design discussed that evaluates a sCO 2 waste heat recovery (WHR) unit for land-based gas turbines at natural gas (NG) compressor stations. The key novelty of the hermetic sCO 2 turbomachine concept is the utilization of additively manufactured CO 2 gas bearings and a CO 2 -immersed direct-drive permanent magnet (PM) electric machine. The previous effort on conceptual design identified 3 main technical risks, which included thrust bearing load capacity, rotordynamics, and thermal performance of the system. Therefore, key requirements of the test vehicle include the ability to test the rotor system in a 400psi (27.6 bar) hermetic CO 2 operating environment, apply up to 1,500 lbs (6.7 kN) of rotor thrust loads, capability to assess rotordynamics with radial gas bearings, inclusion of instrumentation to assess thrust bearing load capability, and flexibility for varying secondary cooling flows to confirm thermal model predictions. Design topics such as rotordynamics, bearing design, and electric machine design are addressed, while highlighting critical elements. In addition, additive build trials for Inconel 718 radial and thrust bearings were performed to prove the manufacturability of the bearing design concepts. The results of the design efforts yield a test rig concept with ability to operate at 27,000 rpm, apply thrust loads to 1,500 lbs, deliver CO 2 up to 800psi, and modulate cooling flows.