Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scan Mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Optical Tweezers Array and Nimble Tweezers Probe Generated by Spatial- Light Modulator

An optical tweezers is being developed at the NASA Glenn Research Center as a visiblelight interface between ubiquitous laser technologies and the interrogation, visualization, manufacture, control, and energization of nanostructures such as silicon carbide (SiC) nanotubes. The tweezers uses one or more focused laser beams to hold micrometer-sized particles called tools (sometimes called tips in atomic-force-microscope terminology). A strongly focused laser beam has an associated light-pressure gradient that is strong enough to pull small particles to the focus, in spite of the oppositely directed scattering force; "optical tweezers" is the common term for this effect. The objective is to use the tools to create carefully shaped secondary traps to hold and assemble nanostructures that may contain from tens to hundreds of atoms. The interaction between a tool and the nanostructures is to be monitored optically as is done with scanning probe microscopes. One of the initial efforts has been to create, shape, and control multiple tweezers beams. To this end, a programmable spatial-light modulator (SLM) has been used to modify the phase of a laser beam at up to 480 by 480 points. One program creates multiple, independently controllable tweezer beams whose shapes can be tailored by making the SLM an adaptive mirror in an interferometer (ref. 1). The beams leave the SLM at different angles, and an optical Fourier transform maps these beams to different positions in the focal plane of a microscope objective. The following figure shows two arrays of multiple beams created in this manner. The patterns displayed above the beam array control the intensity-to-phase transformation required in programming the SLM. Three of the seven beams displayed can be used as independently controllable beams.

Decker, Arthur J.↗

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

NASA Tech Briefs, March 2009

Topics covered include: Improved Instrument for Detecting Water and Ice in Soil; Real-Time Detection of Dust Devils from Pressure Readings; Determining Surface Roughness in Urban Areas Using Lidar Data; DSN Data Visualization Suite; Hamming and Accumulator Codes Concatenated with MPSK or QAM; Wide-Angle-Scanning Reflectarray Antennas Actuated by MEMS; Biasable Subharmonic Membrane Mixer for 520 to 600 GHz; Hardware Implementation of Serially Concatenated PPM Decoder; Symbolic Processing Combined with Model-Based Reasoning; Presentation Extensions of the SOAP; Spreadsheets for Analyzing and Optimizing Space Missions; Processing Ocean Images to Detect Large Drift Nets; Alternative Packaging for Back-Illuminated Imagers; Diamond Machining of an Off-Axis Biconic Aspherical Mirror; Laser Ablation Increases PEM/Catalyst Interfacial Area; Damage Detection and Self-Repair in Inflatable/Deployable Structures; Polyimide/Glass Composite High-Temperature Insulation; Nanocomposite Strain Gauges Having Small TCRs; Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling; Modeling Unsteady Cavitation and Dynamic Loads in Turbopumps; Continuous-Flow System Produces Medical-Grade Water; Discrimination of Spore-Forming Bacilli Using spoIVA; nBn Infrared Detector Containing Graded Absorption Layer; Atomic References for Measuring Small Accelerations; Ultra-Broad-Band Optical Parametric Amplifier or Oscillator; Particle-Image Velocimeter Having Large Depth of Field; Enhancing SERS by Means of Supramolecular Charge Transfer; Improving 3D Wavelet-Based Compression of Hyperspectral Images; Improved Signal Chains for Readout of CMOS Imagers; SOI CMOS Imager with Suppression of Cross-Talk; Error-Rate Bounds for Coded PPM on a Poisson Channel; Biomorphic Multi-Agent Architecture for Persistent Computing; and Using Covariance Analysis to Assess Pointing Performance.

Source record↗

Millimeter-wave passive ultra-compact imaging technology for synthetic vision & mobile platforms

Substantial technical progress was made on all of the three high-risk subsystems of this program. The subsystems include dielectric antenna, G-band receiver, and electro-optic image processor. Progress is approximately on-schedule for both the receiver and the electro-optic processor development, while greater than anticipated challenges have been discovered in the dielectric antenna development. Much of the information in this report was covered in greater detail in the One-Year Review Meeting held at TTC on 22 February 1996. The performance goals of the dielectric antenna project are: Scan Angle -- 20 deg. desired; Loss -- 6 dB end to end (3 dB average); Frequency -- 206-218 GHz (6% bandwidth); Beam width -- 0.25 deg.; and Length -- 12 inches. The scan angle requirement was chosen to satisfy the needs of aircraft pilots. This requirement, coupled with the presently limited bandwidth processors (1 GHz state-of-the-art and 12 GHz in development in this program) forces the antenna to be dielectric (high scan angle air-filled waveguide-based antennas would be too lossy and their performance would vary too much as a function of frequency). A high dielectric constant (e.g., 10) was initially chosen for the dielectric material. This choice lead to the following fabrication challenges: total thickness variation (TTV) tolerance is 1 micrometer; coupler spacing tolerance is 1 micrometer; width tolerance is larger, but unknown, and the surfaces must have mirror finish. Also of importance is the difficulty in obtaining raw materials that satisfy the overall length requirement of 12 inches while simultaneously satisfying the above specifications.

Olsen, Randall↗

Applying the SOFIA Coordinate System to the HIRMES Instrument

The High-resolution Mid-infrared Spectrometer (HIRMES) will be in-flight aboard the Stratospheric Observatory for Infrared Astronomy (SOFIA) in late 2019, which will allow for observations of the structure and evolution of protoplanetary disks. SOFIA has a different coordinate system from the system being used to build HIRMES and needs to be defined and applied to HIRMES. This is necessary because the first mirror, which is aiming the incoming light onto the slit wheel by allowing for tip and tilt adjustments, cannot rotate. Thus, the SOFIA coordinate system allows for this additional degree of freedom and allows for the slit wheel to be in line with the telescope. Using a laser radar, multiple measurements around the instrument were taken of tooling balls, which quantified an uncertainty with the measurements. Also, a laser radar was used to scan the entirety of the instrument. The center of the front flange was determined using the measurements and scans of the instrument, which was used to determine the origin of the SOFIA coordinate system and its uncertainty. By knowing the center of the front flange, an off-center, rotated coordinate system was created, matching the mechanics' schematics for the system. Going forward, this coordinate system will allow for continued alignment of the instrument in preparation for flight and for accurate measurements when aboard SOFIA.

Wraback, Elizabeth↗

X-Ray Testing Constellation-X Optics at MSFC's 100-m Facility

In addition to the 530-m-long X-Ray Calibration Facility (XRCF), NASA's Marshall Space Flight Center (MSFC) operates a 104-m-long (source-to-detector) X-ray-test facility. Originally developed and still occasionally used for stray-light testing of visible-fight optical systems, the so-called "Stray-Light Facility" now serves primarily as a convenient and inexpensive facility for performance evaluation and calibration of X-ray optics and detectors. The facility can accommodate X-ray optics up to about 1-m diameter and 12-m focal length. Currently available electron-impact sources at the facility span the approximate energy range 0.2 to 100 keV, thus supporting testing of soft- and hard-X-ray optics and detectors. Available MSFC detectors are a front-illuminated CCD (charge-coupled device) and a scanning CZT (cadmium--zinc--telluride) detector, with low-energy cut-offs of about 0.8 and 3 keV, respectively. In order to test developmental optics for the Constellation-X Project, led by NASA's Goddard Space Flight Center (GSFC), MSFC undertook several enhancements to the facility. Foremost among these was development and fabrication of a five-degree-of-freedom (5-DoF) optics mount and control system, which translates and tilts the user-provided mirror assembly suspended from its interface plate. Initial Constellation-X tests characterize the performance of the Optical Alignment Pathfinder Two (OAP2) for the large Spectroscopy X-ray Telescope (SXT) and of demonstration mirror assemblies for the Hard X-ray Telescope (HXT). With the Centroid Detector Assembly (CDA), used for precision alignment of the Chandra (nee AXAF) mirrors, the Constellation-X SXT Team optically aligned the individual mirrors of the OAPZ at GSFC. The team then developed set-up and alignment procedures, including transfer of the alignment from the optical alignment facility at GSFC to the X-ray test facility at MSFC, using a reference flat and fiducials. The OAPZ incorporates additional ancillary features --- fixed aperture mask and movable sub-aperture mask --- to facilitate X-ray characterization of the optics. Although the OAPZ was designed to- have low sensitivity to temperature offsets and gradients, analyses showed the necessity of active temperature control for the X-ray performance testing. Thus, the Smithsonian Astrophysical Observatory (SAO) implemented a thermal control and monitoring system, designed to hold the OAP2 close to its assembly.

O'Dell, Stephen↗

Thin film deployable reflector model for ET gamma ray imaging telescope system (ET-GRITS)

The Marshall Space Flight Center is developing a thin film reflector for a Gamma Ray Imaging Telescope System (GRITS) using the Shuttle External Tank (ET). The concept is to install an inflatable reflector in the ET that could be transferred from the orbiter in orbit. This is a study of a scale model reflector for the ET GRITS application. The approach is to form 1/2 mil film into a spherical mirror mounted on a seven-foot diameter metal ring. The ring mount is sealed and slightly evacuated to pressurize the film into shape. Several different fabrication techniques were investigated using seamed gore designs to form the reflector. Also studied was casting a film into a seamless circular sheet. The goal for this model was to achieve a one milliradian (rms) surface curvature error over 90 percent of the reflector area. This curvature was measured by a laser scanning instrument. The results show how different reflector designs and fabrication techniques contribute to surface curvature and focusing errors.

Huegele, Vinson B.↗

Surface control techniques for the segmented primary mirror in the large lunar telescope

The large lunar telescope is a proposed moon-based telescope which incorporates a sixteen-meter segmented primary mirror. An error budget is developed for the active control system of the primary mirror. A control methodology for the primary mirror is then described which utilizes piston sensors for measuring the relative piston error between adjacent segments as well as a separate sensor which measures the tilt of each segment with respect to the pointing direction of the telescope. A trade study is conducted in which the following types of tilt sensors are examined to determine their applicability to this program: stellar wavefront sensors, such as a Hartmann-Shack or a shearing interferometer; holographic optical elements; interferometers; scanning systems; and some nonoptical systems which electronically measure the relative tilt between adjacent segments. In addition, two independent methods of quantitatively verifying the performance of the telescope using either a phase retrieval algorithm or an image sharpening technique, both of which are based on the quality of a stellar image, are presented.

Gleckler, Anthony D.↗

Overview of the MSTI 2 on-orbit alignment

The Miniature Sensor Technology Integration (MSTI) 2 Spacecraft is a small 3-axis stabilized spacecraft designed to track mid-range missiles and estimate their state vectors. In order to accurately estimate the target state vector, the MSTI 2 spacecraft must have highly accurate knowledge of its own attitude. Errors in its attitude knowledge arise primarily from the errors in its Attitude Control System (ACS) sensors. The ACS sensors on the spacecraft include a scanning Earth Sensor (ES), a Sun Sensor (SS), and two 2-axis gyros. The On-Orbit Alignment (OOA) generated an error map of the ES and estimated the biases of the SS and the misalignment of the gyros. This paper discusses some of the error sources, and the techniques used to reduce the effects of these errors. The payload carried by the MSTI2 spacecraft is a high fidelity camera, which was aimed at the target using gimballed mirrors. By aiming it at a celestial target, the payload was used as a high-accuracy single-axis attitude reference. This attitude reference was compared to the attitude reference of the ACS sensors, and the errors were attributed to the ACS sensors.

Rygaard, Christopher A.↗

Observation of Persistent Zero Modes and Superconducting Vortex Doublets in UTe 2

Superconducting vortices can reveal electron pairing details and nucleate topologically protected states. Yet, vortices of bulk spin-triplet superconductors have never been visualized at the atomic scale. Recently, UTe 2 has emerged as a prime spin-triplet superconductor, but its superconducting order parameter is elusive, and whether time-reversal symmetry (TRS) is broken remains unsettled. Here, in this work, we visualize vortices on the (011) surface of ultraclean UTe 2 single crystals (T c = 2.1 K) using scanning tunneling microscopy (STM). We introduce $\frac{d^{2}𝐼}{d𝑉^{2}}$ imaging as an effective technique for vortex visualization in superconductors with substantial residual zero-energy density of states (DOS), as in UTe 2 . Anisotropic single-flux-quantum vortices, with coherence lengths of ∼12 nm (4 nm) parallel (perpendicular) to the a -axis, form a triangular vortex lattice (VL) under a small out-of-plane magnetic field. The invariance of vortex structures and VL under changes of field polarity and cooling history strongly supports time-reversal invariant superconductivity under zero field. At vortex cores (VCs), nonsplit, spectrally sharp zero-bias conductance peaks (ZBPs) persist up 8 T that are consistent with symmetry-protected Majorana zero modes (MZMs) in a topological vortex line. Close examination of vortex structures reveals a mirror-asymmetric doublet─one with ZBPs and another with an enhanced apparent gap, possibly originating from a field-induced multicomponent order parameter.

UTe2↗

Robust, sub-angstrom level mid-spatial frequency profilometry

A noncontacting measurement approach is presented that involves the measurement of the local curvature of the test piece by simultaneously measuring its slope at two slightly displaced locations. As the sensing beams are scanned along the test piece, a profile of curvature is built, from which the height profile is deduced by double integration. The sensing of curvature eliminates the need for a reference surface, and makes the approach insensitive to all types of vibration and drift, both in surface height and in surface slope. The approach is considered to be well suited to measuring grazing incidence optics with highly different transverse and longitudinal radii of curvature. Implementation features including a steering mirror and a movable detector provide for servo tracking of test pieces as fast as F-0.5, with radii as small as 20 mm (convex or concave).

Glenn, Paul↗

Comparison of VIIRS Prelaunch RVS Among Independent Studies

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on the NPOESS (National Polar-orbiting Operational Environmental Satellite System), upgraded and developed recently from heritage instruments including AVHRR, OLS, MODIS, and SeaWiFS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and will be used on-orbit to characterize the response for the all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed and their results were compared and validated. This document provides RVS results from three groups: the NPP Instrument Calibration Support Team (NICST), Raytheon, and the Aerospace Corporation. A comparison of the RVS results obtained using a 2nd order polynomial fit to measurement data is conducted for each band, detector, and half angle mirror (HAM) side. The associated RVS fitting residuals are examined and compared with the relative differences in RVS found between independent studies. Results show that the agreement is within 0.1% and comparable with fitting residuals for all bands except for RSB band M9, where a difference of 0.2% results from the application of the atmospheric water vapor correction for laboratory conditions during the test by Raytheon. NICST has slightly larger RSB RVS uncertainties but still well within the 0.3% total uncertainty allowed for the RVS characterization defined in the Performance Verification Plan.

Wu, Aisheng↗

NASA Tech Briefs, June 2012

Topics covered include: iGlobe Interactive Visualization and Analysis of Spatial Data; Broad-Bandwidth FPGA-Based Digital Polyphase Spectrometer; Small Aircraft Data Distribution System; Earth Science Datacasting v2.0; Algorithm for Compressing Time-Series Data; Onboard Science and Applications Algorithm for Hyperspectral Data Reduction; Sampling Technique for Robust Odorant Detection Based on MIT RealNose Data; Security Data Warehouse Application; Integrated Laser Characterization, Data Acquisition, and Command and Control Test System; Radiation-Hard SpaceWire/Gigabit Ethernet-Compatible Transponder; Hardware Implementation of Lossless Adaptive Compression of Data From a Hyperspectral Imager; High-Voltage, Low-Power BNC Feedthrough Terminator; SpaceCube Mini; Dichroic Filter for Separating W-Band and Ka-Band; Active Mirror Predictive and Requirement Verification Software (AMP-ReVS); Navigation/Prop Software Suite; Personal Computer Transport Analysis Program; Pressure Ratio to Thermal Environments; Probabilistic Fatigue Damage Program (FATIG); ASCENT Program; JPL Genesis and Rapid Intensification Processes (GRIP) Portal; Data::Downloader; Fault Tolerance Middleware for a Multi-Core System; DspaceOgreTerrain 3D Terrain Visualization Tool; Trick Simulation Environment 07; Geometric Reasoning for Automated Planning; Water Detection Based on Color Variation; Single-Layer, All-Metal Patch Antenna Element with Wide Bandwidth; Scanning Laser Infrared Molecular Spectrometer (SLIMS); Next-Generation Microshutter Arrays for Large-Format Imaging and Spectroscopy; Detection of Carbon Monoxide Using Polymer-Composite Films with a Porphyrin-Functionalized Polypyrrole; Enhanced-Adhesion Multiwalled Carbon Nanotubes on Titanium Substrates for Stray Light Control; Three-Dimensional Porous Particles Composed of Curved, Two-Dimensional, Nano-Sized Layers for Li-Ion Batteries 23 Ultra-Lightweight; and Ultra-Lightweight Nanocomposite Foams and Sandwich Structures for Space Structure Applications.

Source record↗

NASA Tech Briefs, May 2012

Topics covered include: An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently; On-Wafer Measurement of a Multi-Stage MMIC Amplifier with 10 dB of Gain at 475 GHz; Software to Control and Monitor Gas Streams; Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column; Anomaly Detection in Test Equipment via Sliding Mode Observers; Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems; Goldstone Solar System Radar Waveform Generator; Fast and Adaptive Lossless Onboard Hyperspectral Data Compression System; Iridium Interfacial Stack - IrIS; Downsampling Photodetector Array with Windowing; Optical Phase Recovery and Locking in a PPM Laser Communication Link; High-Speed Edge-Detecting Line Scan Smart Camera; Optical Communications Channel Combiner; Development of Thermal Infrared Sensor to Supplement Operational Land Imager; Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Histogrammatic Method for Determining Relative Abundance of Input Gas Pulse; Predictive Sea State Estimation for Automated Ride Control and Handling - PSSEARCH; LEGION: Lightweight Expandable Group of Independently Operating Nodes; Real-Time Projection to Verify Plan Success During Execution; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Web-Based Customizable Viewer for Mars Network Overflight Opportunities; Fabrication of a Cryogenic Terahertz Emitter for Bolometer Focal Plane Calibrations; Fabrication of an Absorber-Coupled MKID Detector; Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays; Method of Bonding Optical Elements with Near-Zero Displacement; Free-Mass and Interface Configurations of Hammering Mechanisms; Wavefront Compensation Segmented Mirror Sensing and Control; Long-Life, Lightweight, Multi-Roller Traction Drives for Planetary Vehicle Surface Exploration; Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications; Electrochemical Ultracapacitors Using Graphitic Nanostacks; Improved Whole-Blood-Staining Device; Monitoring Location and Angular Orientation of a Pill; Molecular Technique to Reduce PCR Bias for Deeper Understanding of Microbial Diversity; Laser Ablation Electrodynamic Ion Funnel for In Situ Mass Spectrometry on Mars; High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle; PRTs and Their Bonding for Long-Duration, Extreme-Temperature Environments; Mid- and Long-IR Broadband Quantum Well Photodetector; 3D Display Using Conjugated Multiband Bandpass Filters; Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow; Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators; Dual-Compartment Inflatable Suitlock; Large-Strain Transparent Magnetoactive Polymer Nanocomposites; Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine; Time Distribution Using SpaceWire in the SCaN Testbed on ISS; and Techniques for Solution- Assisted Optical Contacting.

Source record↗

Analysis of open-loop conical scan pointing error and variance estimators

General pointing error and variance estimators for an open-loop conical scan (conscan) system are derived and analyzed. The conscan algorithm is modeled as a weighted least-squares estimator whose inputs are samples of receiver carrier power and its associated measurement uncertainty. When the assumptions of constant measurement noise and zero pointing error estimation are applied, the variance equation is then strictly a function of the carrier power to uncertainty ratio and the operator selectable radius and period input to the algorithm. The performance equation is applied to a 34-m mirror-based beam-waveguide conscan system interfaced with the Block V Receiver Subsystem tracking a Ka-band (32-GHz) downlink. It is shown that for a carrier-to-noise power ratio greater than or equal to 30 dB-Hz, the conscan period for Ka-band operation may be chosen well below the current DSN minimum of 32 sec. The analysis presented forms the basis of future conscan work in both research and development as well as for the upcoming DSN antenna controller upgrade for the new DSS-24 34-m beam-waveguide antenna.

Alvarez, L. S.↗

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping↗

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/- 9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping↗

Tuning Interface Electronic Properties via Chiral Two‐Dimensional Metal‐Organic Frameworks

Control over structural symmetries in nanomaterials offers a powerful approach to engineer electronic properties. For instance, breaking of mirror symmetries in two-dimensional (2D) materials with a hexagonal lattice can lead to nontrivial electronic topologies and correlated-electron phenomena. Yet, the impact of structural chirality on the electronic properties of 2D materials and interfaces remains underexplored. Here, how chiral phases of a 2D metal-organic framework (MOF) with a hexagonal lattice—consisting of hexaazatriphenylene molecules coordinated to Cu atoms—scatter, confine, and perturb the Shockley surface state (SS) electrons of an underlying Ag(111) substrate is investigated. Via low-temperature scanning tunneling microscopy and spectroscopy, noncontact atomic force microscopy, and numerical calculations based on an electronic plane-wave expansion method, modifications of the Ag(111) SS band structure are shown and quantified, including gap openings and lifts of band degeneracies, driven exclusively by the structural chirality of the 2D MOF phases. These findings highlight how structural symmetries, in particular chirality, affect electronic states at material interfaces, expanding on the toolkit for designing 2D materials with tailored electronic properties.

band structure engineering↗