Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Development of the Intelligent, Preventive Infrared (IR) Inspection System Housed in Hybrid Robotic Platforms

Robots and robotic systems that are designed for inspection, environmental study, and health and safety aid are becoming an increasing necessity. However, there is a number of challenges that accompany robots that are designed for these specific applications. These challenges include: navigating compact, enclosed spaces, travelling over multiple terrains and large obstacles, using the proper sensing and detection methods to assess an environment, and the use of lightweight and durable materials. The robotic platforms currently in development look at all of these challenges and attempt to overcome them. These designs specific use of hybrid robotic platforms, or platform that utilizes soft and rigid materials, allows for a more flexible platform and makes environments more navigable. To further improve the navigation of the platforms and environmental assessment, a novel infrared detection system is housed in the platforms to create a robot that can be used for the applications listed above and more. Objectives: Further develop two types of robotic platforms that utilize additive manufacturing, soft materials, and rigid materials. Continue the development of an intelligent and inhibitory infrared detection system based on an artificial intelligence (AI) algorithm. Continued study and fabrication of active soft materials designed for both sensing and actuation in hybrid robotic systems. Improve additive manufacturing fabrication to design rigid and semi-rigid components for hybrid robotic platforms. Transformable Wheel Robotic Platform: The chassis, wheels, tires and inspection system housing use different additive manufacturing techniques for fabrication. Continued work with additive manufacturing has lead to studies in metal-based printing and modular design and manufacturing. The new platform design with integrated electrical component printed. This will allow integration of the sensor housing onto the platform. Electrical components are being tested for battery life and performance. To improve this performance, such as integration of Lithium Polymer (LiPo) batteries. Snake Robotic Platform: The main focus of the development has centered around liquid-based soft actuators. That act on the principles of electrostatic and hydraulic actuation. A liquid dielectric sits between two compliant electrodes, contained by a flexible polymer shell. The electrodes and film gradually collapse toward each other from one corner of the electrode to the other. When the electrodes and film close together, a majority of the fluid is pushed into the area not covered by an electrode. A thin layer of the liquid dielectric remains between the electrode. The actuators will be stacked to cause large displacement, and move the linkages. The chassis of this platform uses purely additively manufactured linkages. Intelligent, Preventive IR Inspection System: Development of the AI for the system has lead to using a Scikit-Learn which assists in creating predictive models based on Regression, clustering, classification etc. To improve the infrared thermometry for low emissivity sources, work on the fabrication of a tandem photoconductive infrared thermometer was a main focus. Distance-Voltage-Temperature response data has been collected in the range of 7 cm - 100 cm and 200-400 deg. C. Modifications were made to the existing test bench to have a better control over the data. Automated data collection was realized using a Python code and an Arduino controlled stepper motor to increase the sample rate. A protective enclosure has been built around the setup to minimize the effect of the environment on the measurements. To better predict temperature, different AI models are being optimized. The regression model, LARS showed a high accuracy but had convergence issues and only works for the current test set-up. Results: The Transformable Wheel Robot has developed into a more flexible and modular platform. With the improvements to the current work, effort on the tire or soft gripper design been a large focus. The soft grippers will be interchange able to allow for increased performance in identified terrain types. The development of the liquid-based actuators allows the snake robotic platform to achieve the goals of being flexible and able to navigate confined spaces. However, there is room for improvement. Optimization work is currently being done in COMSOL Multiphysics. With the current IR system set-up the LARS model perfectly predicts the data; however, considering the mobility aspect of the project other models will allow for an optimized system. Testing of other model types is currently being done.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flexible Electronics toward Wearable Sensing

Wearable sensors play a crucial role in realizing personalized medicine, as they can continuously collect data from the human body to capture meaningful health status changes in time for preventive intervention. However, motion artifacts and mechanical mismatches between conventional rigid electronic materials and soft skin often lead to substantial sensor errors during epidermal measurement. Because of its unique properties such as high flexibility and conformability, flexible electronics enables a natural interaction between electronics and the human body. Here, we summarize our recent studies on the design of flexible electronic devices and systems for physical and chemical monitoring. Material innovation, sensor design, device fabrication, system integration, and human studies employed toward continuous and noninvasive wearable sensing are discussed. A flexible electronic device typically contains several key components, including the substrate, the active layer, and the interface layer. The inorganic-nanomaterials-based active layer (prepared by a physical transfer or solution process) is shown to have good physicochemical properties, electron/hole mobility, and mechanical strength. Flexible electronics based on the printed and transferred active materials has shown great promise for physical sensing. For example, integrating a nanowire transistor array for the active matrix and a conductive pressure-sensitive rubber enables tactile pressure mapping; tactile-pressure-sensitive e-skin and organic light-emitting diodes can be integrated for instantaneous pressure visualization. Such printed sensors have been applied as wearable patches to monitor skin temperature, electrocardiograms, and human activities. In addition, liquid metals could serve as an attractive candidate for flexible electronics because of their excellent conductivity, flexibility, and stretchability. Liquid-metal-enabled electronics (based on liquid-liquid heterojunctions and embedded microchannels) have been utilized to monitor a wide range of physiological parameters (e.g., pulse and temperature). Despite the rapid growth in wearable sensing technologies, there is an urgent need for the development of flexible devices that can capture molecular data from the human body to retrieve more insightful health information. We have developed a wearable and flexible sweat-sensing platform toward real-time multiplexed perspiration analysis. An integrated iontophoresis module on a wearable sweat sensor could enable autonomous and programmed sweat extraction. A microfluidics-based sensing system was demonstrated for sweat sampling, sensing, and sweat rate analysis. Roll-to-roll gravure printing allows for mass production of high-performance flexible chemical sensors at low cost. These wearable and flexible sweat sensors have shown great promise in dehydration monitoring, cystic fibrosis diagnosis, drug monitoring, and noninvasive glucose monitoring. Future work in this field should focus on designing robust wearable sensing systems to accurately collect data from the human body and on large-scale human studies to determine how the measured physical and chemical information relates to the individual's specific health conditions. Further research in these directions, along with the large sets of data collected via these wearable and flexible sensing technologies, will have a significant impact on future personalized healthcare.

47 OTHER INSTRUMENTATION↗

Assessment of Flow-Enhanced Sensors for Actinide Quantification in MSRs

This report serves as the deliverable for Milestone M2RS-22AN0401062 that is part of Work Package RS-22AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone is to assess the capabilities of flow-enhanced electrochemical sensors (FEES) to quantify actinides in molten salt reactors. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits in order to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. To support this work, Argonne constructed a molten salt flow system to serve as a testbed for the development of safeguards and process monitoring-relevant sensors in challenging molten salt flow conditions. Through extensive flow testing using UCl3-bearing salts, Argonne has been able to show that the FEES are able to make good measurements of salt composition. Concentration measurements with a mean absolute error of 0.09 wt% have been achieved for representative fuel salt mixtures across a range of UCl3 loadings. Repeatability was also good, with the relative standard deviation from repeated measurements being less than 1.0%. These sensors have also been shown to be able to measure the flow rate of the salt within the flow system’s transfer line. Although the accuracy of the sensors has been good, the sensors have thus far not been able to achieve performance good enough to satisfy the nuclear material accountancy requirements in 10 CFR 74. To do so, accuracy levels of 0.1% must be achieved; the FEES when operated in Argonne’s flow system have so far only been able to achieve relative errors of approximately 5.0%. Much of the error that has been observed at this stage is due to challenges in maintaining a stable salt composition in the molten salt flow system, and it is not believed that there are any inherent flaws in the sensor design. Nonetheless, the high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will likely be needed to push the measurement accuracy to the needed level.

Moore, Colin E.↗

Thin, Flexible Sensors and Actuators as ‘Instrumented’ Surgical Sutures for Targeted Wound Monitoring and Therapy

Proper healing of incised skin is critical to the natural processes of tissue repair. Concepts in flexible silicon electronics enable integration of actuators, sensors and a variety of semiconductor devices onto thin strips of plastic or biopolymers, to yield ‘instrumented’ suture threads for monitoring and accelerating the wound healing in this context. Bifacial systems of this type demonstrate various classes of functionality, in live animal models. Furthermore, detailed modelling of the mechanics reveals stress and strain distributions in such applications, to support design strategies for robust operation.

60 APPLIED LIFE SCIENCES↗

Demonstrating Advanced Sensors for In-Situ Monitoring Towards Qualification of Nuclear Relevant Components

The U.S. Department of Energy’s Office of Nuclear Energy Advanced Materials and Manufacturing Technologies (AMMT) program is pursuing qualification of laser powder bed fusion (LPBF) components for nuclear applications. A major focus of this effort is the use of in situ process monitoring and machine learning–based tools to establish real-time quality assurance. The primary objective of this report is to identify and evaluate the most relevant in situ sensor systems for LPBF, and to document the deployment of these systems across platforms critical to the AMMT program. This work demonstrates how in situ monitoring can detect process anomalies, track geometry-dependent flaws, and identify limiting combinations of processing parameters—particularly those related to energy density and complex geometries (e.g., overhanging structures). To support this goal, a diverse suite of sensor modalities was evaluated across LPBF platforms, including visible and near-infrared (NIR) imaging, fringe projection profilometry, long-wavelength infrared (LWIR) thermography, and high-speed photodiode/pyrometry systems. These sensor streams were integrated with Peregrine, a machine-agnostic software platform that, among other capabilities, can generate real-time process anomaly classification. This report documents sensor deployments on multiple AMMT flagship platforms, including the Concept Laser M2 and Renishaw AM400/AM250 systems. Calibration builds with complex, flaw-prone geometries such as unsupported overhangs, stepped features, and thin walls, were used to evaluate how well Peregrine and its associated sensors could detect process anomalies and other instabilities under varied energy densities. It will be shown how Peregrine reliably identifies common process anomalies such as recoater streaking, superelevation, etc., and can be used in post-build analysis for anomaly spatial distributions throughout the build height to better understand the impact of geometry and processing parameter choice on the build. This work demonstrates measurable progress toward the vision that components can be born-qualified by establishing a real-time monitoring framework, identifying limiting process conditions, and laying the foundation for sensor fusion–enabled prediction pipelines that are scalable across platforms and applicable to nuclear-relevant components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Silicon on-chip bandpass filters for the multiplexing of high sensitivity photonic crystal microcavity biosensors

A method for the dense integration of high sensitivity photonic crystal (PC) waveguide based biosensors is proposed and experimentally demonstrated on a silicon platform. By connecting an additional PC waveguide filter to a PC microcavity sensor in series, a transmission passband is created, containing the resonances of the PC microcavity for sensing purpose. With proper engineering of the passband, multiple high sensitivity PC microcavity sensors can be integrated into microarrays and be interrogated simultaneously between a single input and a single output port. The concept was demonstrated with a 2-channel L55 PC biosensor array containing PC waveguide filters. The experiment showed that the sensors on both channels can be monitored simultaneously from a single output spectrum. Less than 3 dB extra loss for the additional PC waveguide filter is observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Persistent DynAMICS

Persistent DynAMICS is a lightweight software platform that enables distributed sensing systems to operate as a unified, responsive network. It integrates with existing sensors, data systems, and processing tools as an overlay, without requiring hardware replacement or increasing user burden. As data is collected, the system identifies situations that require additional attention and directs selected sensors to gather more information. For example, if a sensor detects an unusual condition along a pipeline, the system can task nearby sensors or different sensing modalities to confirm the event and focus data collection where it is needed. To support this, the platform forms temporary groups of sensors that work together to address specific objectives. Once complete, these groups are dissolved and resources are reassigned as needed. Communication is handled through an integrated messaging framework with client and server components, enabling reliable operation and data continuity even in low-bandwidth or intermittent connectivity environments.

97 MATHEMATICS AND COMPUTING↗

Comprehensive Characterization of Silicon Photomultipliers for Nuclear Security Applications

Scintillation detectors are an essential instrument in a variety of fields, serving as an effective means of detecting radiation for industrial, defense, medical, and basic-research applications. Light sensors are an integral part of all scintillation detectors and can affect detector performance as much as the scintillator itself. The photomultiplier tube (PMT) has been the standard light sensor for over half a century, but alternatives have been developed recently, and the silicon photomultiplier (SiPM) is perhaps the most promising of these new technologies. SiPMs can produce gains of the same order of magnitude as most PMTs and have shown reduced noise levels in the newest generations. Additionally, they posses benefits characteristic of solid-state devices such as insensitivity to magnetic fields, mechanical ruggedness, compactness, low operating voltages, and high quantum efficiencies. The timing properties of light sensors are an important characteristic for many applications, including nuclear security. For example, accurate timing is necessary for time of flight experiments, scatter cameras, and background suppression. This work aims to characterize the time resolution of many commercially available new-generation SiPMs, specifically in a time coincidence setting. SiPMs have been acquired from five leading manufacturers possessing a variety of pixel and microcell sizes. Results are presented with an organic scintillator p-terphenyl and coincidence time resolution of less than 300 picoseconds is achieved. Comparison with PMTs shows that the PMT pair tested has a superior time resolution of 83 picoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The overvoltage protection module for the power supply system for the pixel detector at Belle II experiment at KEK

In this paper the overvoltage protection modules (OVP) for the power supply (PS) system of the Belle II pixel detector (PXD) are described. The aim of the OVP is to protect the detector and associated electronics against overvoltage conditions. Most critical in the system are voltages supplying the front-end ASICs. The PXD detector consists of the DEPFET sensor modules with integrated chips like the Drain Current Digitizer, the Switcher and the Data Handling Processor. These chips, implemented in modern sub-micron technologies, are quite vulnerable to variations in the supply voltages. The PXD will be placed in the Belle II experiment as close as possible to the interaction point, where access during experiment is very limited or even impossible, thus the PS and OVP systems exploit the remote-sensing method. Overvoltage conditions are due to failures of the PS itself, wrong setting of the output voltages or transient voltages coming out of hard noisy environment of the experiment. The OVP modules are parts of the PS modules. For powering the PXD 40 PS modules are placed 15 m outside the Belle II spectrometer. Each one is equipped with the OVP board. All voltages (22) are grouped in 4 domains: Analog, Digital, Steering and Gate which have independent grounds. The OVP boards are designed from integrated circuits from Linear Technology. All configurations were simulated with the Spice program. The control electronics is designed in a Xilinx CPLD. Two types of integrated circuits were used. LT4356 surge stopper protects loads from high voltage transients. The output voltages are limited to a safe value and also protect loads against over current faults. For less critical voltages, the LTC2912 voltage monitors are used that detect under-voltage and overvoltage events. It has to be noted that the OVP system is working independently of any other protection of the PS system, which increases its overall reliability. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated SQUID/Sensor Metallic Magnetic Microcalorimeter for Gamma-Ray Spectroscopy

Metallic magnetic microcalorimeters (MMCs) achieve energy resolution comparable to transition-edge sensors (TESs) but rely on different measurement physics that may allow MMCs to surpass TESs in some future applications. We have recently completed fabrication of new MMC γ-ray detector arrays using several exploratory sensor designs. All designs integrate the SQUID and sensor on the same chip and use a superconducting cap layer on the paramagnet, but explore different combinations of combined/separate sensing and magnetization coils and direct/flux transformer coupling to the input SQUIDs. This report describes the design and initial testing of one of these devices, which has so far demonstrated an energy resolution of 38 eV at 60 keV near 10 mK using natural-abundance silver–erbium paramagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Savannah River Site H-Canyon Advancing Technologies for Remote Inspections - 20345

In 2017, the DOE Environmental Management Office of Technology Development (DOE-EM TD) sponsored the H-Canyon Advanced Technology Demonstration (ATD) to demonstrate to DOE facilities the value of using new commercial-off-the-shelf (COTS) and near-ready technologies to solve difficult problems and enhance worker safety. The DOE Savannah River Site (SRS) H-Canyon Air Exhaust Tunnel (HCAEX) inspection task was identified as representative of the hazardous, human denied environments which could benefit from advanced technologies. The HCAEX underground concrete tunnel is visually inspected biannually using a camera mounted on a remotely operated vehicle (ROV) designed and built by SRNL. While tunnel images have provided valuable visual information, it is desirable to have a higher order of understanding of the environment to support a more thorough structural integrity (SI) analysis and for long term planning purposes. As part of the ATD, the Concrete Integrated Product Team (CIPT) was formed to identify and evaluate available sensors and methods mature enough to remotely obtain tunnel concrete characterization data of high value and with a high probability of success. The team included SMEs and H-Canyon stakeholders in the field of concrete, nondestructive examination (NDE), structural integrity, sensors and remote systems from SRNL, SRNS, LANL, DOE-SR and the Army Corps of Engineering. The CIPT completed an in-depth identification of customer concrete inspection needs and potential technology solutions. Sensors and methods were evaluated on performance, data usefulness, cost and the feasibility of a successful deployment given the unique tunnel access challenges and environment. Two technologies were identified as promising by the CIPT for near term demonstration and evaluation: Lidar (Light Detection and Ranging) 3-dimensional (3D) mapping and remote robotic deployment of NDE instrumentation. Laser spectroscopy to characterize tunnel surface chemical changes was also of interest, but presently cost prohibitive. This paper will include a discussion of the two efforts underway to evaluate and implement the CIPT recommendations. First, the status of the November 2019 deployment of Lidar at a single location into the tunnel is presented. This initial deployment provided the team a learning curve and lessons learned on the challenges of tunnel deployment to include remote operation and data collection, stabilization of the sensor in high air flow (∼30 mph), ability to achieve a tolerance accuracy of 0.25-inches, and the probability to identify change in tunnel dimensions over time. Secondly, a discussion on the development of the Robotic Arm Concrete Inspection Test Bed capable of deploying NDE instruments to examine custom concrete forms will be presented. Concrete forms simulating the rough concrete surfaces, strength, composition and potential structural defects that can be found at our DOE EM facilities have been designed and built for the test bed. Two state-of-the art concrete NDE instruments have been identified as having potential to work on rough concrete walls, they are being tested and characterized as to their ability to provide desired structural integrity data to include wall thickness and defect identification on the developed test beams. Lastly, lessons learned, and the path forward will be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Semi autonomous mine detection system

CMMAD is a risk reduction effort for the AMDS program. As part of CMMAD, multiple instances of semi autonomous robotic mine detection systems were created. Each instance consists of a robotic vehicle equipped with sensors required for navigation and marking, a countermine sensors and a number of integrated software packages which provide for real time processing of the countermine sensor data as well as integrated control of the robotic vehicle, the sensor actuator and the sensor. These systems were used to investigate critical interest functions (CIF) related to countermine robotic systems. To address the autonomy CIF, the INL developed RIK was extended to allow for interaction with a mine sensor processing code (MSPC). In limited field testing this system performed well in detecting, marking and avoiding both AT and AP mines. Based on the results of the CMMAD investigation we conclude that autonomous robotic mine detection is feasible. In addition, CMMAD contributed critical technical advances with regard to sensing, data processing and sensor manipulation, which will advance the performance of future fieldable systems. As a result, no substantial technical barriers exist which preclude – from an autonomous robotic perspective – the rapid development and deployment of fieldable systems.

42 ENGINEERING↗

Performance Evaluation of Comparative Vacuum Monitoring and Piezoelectric Sensors for Structural Health Monitoring of Rotorcraft Components

The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

Glancing Angle Deposition in Gas Sensing: Bridging Morphological Innovations and Sensor Performances

Glancing Angle Deposition (GLAD) has emerged as a versatile and powerful nanofabrication technique for developing next-generation gas sensors by enabling precise control over nanostructure geometry, porosity, and material composition. Through dynamic substrate tilting and rotation, GLAD facilitates the fabrication of highly porous, anisotropic nanostructures, such as aligned, tilted, zigzag, helical, and multilayered nanorods, with tunable surface area and diffusion pathways optimized for gas detection. This review provides a comprehensive synthesis of recent advances in GLAD-based gas sensor design, focusing on how structural engineering and material integration converge to enhance sensor performance. Key materials strategies include the construction of heterojunctions and core–shell architectures, controlled doping, and nanoparticle decoration using noble metals or metal oxides to amplify charge transfer, catalytic activity, and redox responsiveness. GLAD-fabricated nanostructures have been effectively deployed across multiple gas sensing modalities, including resistive, capacitive, piezoelectric, and optical platforms, where their high aspect ratios, tailored porosity, and defect-rich surfaces facilitate enhanced gas adsorption kinetics and efficient signal transduction. These devices exhibit high sensitivity and selectivity toward a range of analytes, including NO2, CO, H2S, and volatile organic compounds (VOCs), with detection limits often reaching the parts-per-billion level. Emerging innovations, such as photo-assisted sensing and integration with artificial intelligence for data analysis and pattern recognition, further extend the capabilities of GLAD-based systems for multifunctional, real-time, and adaptive sensing. Finally, current challenges and future research directions are discussed, emphasizing the promise of GLAD as a scalable platform for next-generation gas sensing technologies.

Chemistry↗

Colossal Magnetoresistive Manganite Based Fast Bolometric X-ray Sensors for Total Energy Measurements of Free Electron Lasers

Bolometric detectors based on epitaxial thin films of rare earth perovskite manganites have been proposed as total energy monitors for X-ray pulses at the Linac Coherent Light Source free electron laser. We demonstrate such a detector scheme based on epitaxial thin films of the perovskite manganese oxide material Nd{sub 0.67}Sr{sub x0.33}MnO{sub 3}, grown by pulsed laser deposition on buffered silicon substrates. The substrate and sensor materials are chosen to meet the conflicting requirements of radiation hardness, sensitivity, speed and linearity over a dynamic range of three orders of magnitude. The key challenge in the material development is the integration of the sensor material with Si. Si is required to withstand the free electron laser pulse impact and to achieve a readout speed three orders of magnitude faster than conventional cryoradiometers for compatibility with the Linac Coherent Light Source pulse rate. We discuss sensor material development and the photoresponse of prototype devices. This Linac Coherent Light Source total energy monitor represents the first practical application of manganite materials as bolometric sensors.

36 MATERIALS SCIENCE↗

OPEN leaf : an open‐source cloud‐based phenotyping system for tracking dynamic changes at leaf‐specific resolution in Arabidopsis

SUMMARY The first draft of the Arabidopsis genome was released more than 20 years ago and despite intensive molecular research, more than 30% of Arabidopsis genes remained uncharacterized or without an assigned function. This is in part due to gene redundancy within gene families or the essential nature of genes, where their deletion results in lethality (i.e., thedark genome). High‐throughput plant phenotyping (HTPP) offers an automated and unbiased approach to characterize subtle or transient phenotypes resulting from gene redundancy or inducible gene silencing; however, access to commercial HTPP platforms remains limited. Here we describe the design and implementation ofOPEN leaf, an open‐source phenotyping system with cloud connectivity and remote bilateral communication to facilitate data collection, sharing and processing.OPEN leaf, coupled with our SMART imaging processing pipeline was able to consistently document and quantify dynamic changes at the whole rosette level and leaf‐specific resolution when plants experienced changes in nutrient availability. Our data also demonstrate that VIS sensors remain underutilized and can be used in high‐throughput screens to identify and characterize previously unidentified phenotypes in a leaf‐specific time‐dependent manner. Moreover, the modular and open‐source design ofOPEN leafallows seamless integration of additional sensors based on users and experimental needs.

Plant Sciences↗