Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Energy Savings with Highly-Controlled Lighting in an Open-Plan Office

An installation in a Federal building tested the effectiveness of a highly-controlled, workstation-specific lighting retrofit. The study took place in an open-office area with 86 cubicles and low levels of daylight. Each cubicle was illuminated by a direct/indirectpendant luminaire with three 32 watt lamps, two dimmable DALI ballasts, and an occupancy sensor. A centralized control system programmed all three lamps to turn on and off according to occupancy on a workstation-by-workstation basis. Field measurements taken over the course of several monthsdemonstrated 40% lighting energy savings compared to a baseline without advanced controls that conforms to GSA's current retrofit standard. A photometric analysis found that the installation provided higher desktop light levels than the baseline, while an occupant survey found that occupants in general preferred the lighting system to thebaseline.Simple payback is fairly high; projects that can achieve lower installation costs and/or higher energy savings and those in which greenhouse gas reduction and occupant satisfaction are significant priorities provide the ideal setting for workstation-specific lighting retrofits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods and systems for evaluating data transportability in distribution grids

This document describes systems and techniques for evaluating and improving distribution-grid data transportability. These systems and techniques allow engineers to quantify the data transportability of a communication system within or connected to a distribution grid, which represents an ability to transport in real-time telemetry from source locations (e.g., sensors in the distribution grid) to control mechanisms. Distribution engineers can use the sensor readings to perform grid analytics, control operating parameters, and operate protection systems. Distribution engineers can also use the transportability of the communication system to evaluate the observability of the distribution grid, which represents an ability to combine actual measurements and various types of computations (e.g., analytics, estimators, forecasters) from a system model. Distribution engineers can then generate a sensor allocation plan that indicates the number and location of sensors to maximize observability for a fixed sensor cost and/or minimize sensor cost for predetermined observability.

Taft, Jeffrey D.↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

Engineering in Cyber Resilience with Cyber-Informed Engineering

Engineers have super powers to provide cybersecurity resilience with deterministic engineering solutions and to protect systems from the most catastrophic consequences that a cyber saboteur could cause. Come to this session to learn how to use engineering risk management skills to harden your engineered systems from cyberattacks. Objective 1 Identify what system functions could be digitally induced to cause undesired high-impact consequences. Objective 2 Analyze how loss or instability of digital controls in a subsystem could lead to high-impact consequences. Objective 3 Analyze how loss or instability in the digital connectivity between systems could lead to high-impact consequences. Objective 4 Identify engineering controls which could build resilience by eliminating digital loss or instability pathways or reduce the impact of digital loss or instability. This presentation will introduce Cyber-Informed Engineering, described below, and walk participants through specific engineering use cases to show how engineers can consider the potential for cyber sabotage in their existing system designs and enact deterministic engineering-based controls which eliminate pathways for attack or mitigate specific consequences. A wide variety of application use cases will be considered so that audience members can align the material with familiar engineering applications. CIE is an engineering approach that integrates cyber resilience into the conception, design, build, and operation of any physical system that has digital connectivity, sensors, monitoring, or control. CIE offers the opportunity to use engineering to eliminate or mitigate avenues for cyber attack—starting from the earliest stage of design and continuing throughout the system’s lifecycle. Today, engineers and industrial control system (ICS) technicians build engineered systems with specific goals for safety, reliability, and functionality. While systems engineering includes considerable safety and failure mode analysis, cybersecurity risks are often not specifically addressed—particularly the risks of intentional cyber compromise, exploitation, and misuse. Cyber-Informed Engineering pairs well with traditional cyber defenses and offers an extra designed-in protection to eliminate the most catastrophic consequences which can be realized by an adversary should traditional cyber defenses fail.

42 ENGINEERING↗

A high-precision miniaturized rotating coil transducer for magnetic measurements

A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.

06.20.fb/calibration↗

Automated Glovebox Work-cell Design - 18370

Los Alamos National Laboratory (LANL) is the primary plutonium science and manufacturing facility in the United States supporting multiple national security programs. It is responsible for completing a high variety of small-batch manufacturing tasks requiring the handling and precision machining of Special Nuclear Materials (SNM). Given the myriad of tasks that must be completed in a limited workspace, LANL intends to utilize flexible, multi-use robotic work-cells capable of completing a variety of mission critical tasks in a single glovebox with no re-tooling needed between batch jobs. This approach would allow LANL more flexibility in its production schedule and to meet its future production and research objectives. In this paper, we present a system that integrates multiple sensors and other manufacturing peripherals into existing glovebox infrastructure. Currently, a technician can place an object in the work area where vision sensors and supervisory software identify the object and its pose and automatically determine which manufacturing task to complete. Pose uncertainty is addressed in real-time by the task planner, eliminating the need for fixtures. Grasps are validated using pressure sensors, payload sensors, and grasp quality metrics to ensure that objects are not dropped or damaged during manipulation. The robot, sensors, and peripherals are controlled using open-source software built utilizing ROS (Robot Operating System), which minimizes redevelopment and allows for re-use and extensibility. Established capabilities support vision, collision-free path planning, and more, minimizing development time. For this effort, particular attention was given to the integration of general peripheral devices (drill, chuck, etc.), which is critical to efficiently utilizing ROS in manufacturing environments. This integration is achieved with an in-development framework that allows for quick integration of peripherals, including I/O devices and motors. Contact tasks utilize the Generalized Contact Control Framework (GCCF) previously developed at UT Austin. GCCF allows application developers to easily define multiple contact control tasks for a single robot. This paper summarizes the key software components necessary to develop the multi-use work-cell including existing ROS components. UT-developed software for grasp validation, peripheral integration, and contact control is presented in more depth. Finally the glovebox system is demonstrated completing a set of tasks with no fixturing necessary. Primary tasks include surface preparation/ablation, drilling, press-fitting, and sorting, as well as supporting material transfer and inspection tasks. The glovebox work-cell reduces cost, operator dose, ergonomic issues, and time loss due to material transfer between gloveboxes that only support one task. If multiple glovebox work-cells are in use, they have the potential to eliminate bottlenecks and scale production capabilities beyond current limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chapter 14: Wind Turbine Control Systems

Wind turbines are complex, nonlinear, dynamic systems forced by gravity, stochastic wind disturbances, and gravitational, centrifugal, and gyroscopic loads. The aerodynamic behavior of wind turbines is nonlinear, unsteady, and complex. Turbine rotors are subjected to a complicated three-dimensional turbulent wind inflow field that drives fatigue loading. Wind turbine modeling is also complex and challenging. Accurate models must contain many degrees of freedom (DOF) to capture the most important dynamic effects. The rotation of the rotor adds complexity to the dynamics modeling. Designs of control algorithms for wind turbines must account for these complexities. Algorithms must capture the most important turbine dynamics without being too complex and unwieldy. Off-the-shelf commercial soft ware is seldom adequate for wind turbine dynamics modeling. Instead, specialized dynamic simulation codes are usually required to model all the important nonlinear effects. As illustrated in Figure 14-1, a wind turbine control system consists of sensors, actuators and a system that ties these elements together. A hardware or software system processes input signals from the sensors and generates output signals for actuators. The main goal of the controller is to modify the operating states of the turbine to maintain safe turbine operation, maximize power, mitigate damaging fatigue loads, and detect fault conditions. A supervisory control system starts and stops the machine, yaws the turbine when there is a significant yaw misalignment, detects fault conditions, and performs emergency shut-downs. Other parts of the controller are intended to maximize power and reduce loads during normal turbine operation.

17 WIND ENERGY↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building an Adaptive Optics Demonstrator System

Adaptive optics is used to correct the wavefront of a beam of light. It originated in the field of astronomy to correct for atmospheric turbulence. This project was to construct an adaptive optics (AO) system kit from Thorlabs. An AO system consists of three parts: a deformable mirror (DM), a wavefront sensor (WFS), and control software. This system is to be used for future teaching purposes to help others learn about adaptive optics. The AO system came with instruction manuals, which were followed to build and calibrate the system. The instructions included building and aligning the system, how to install and use the software, and how to calibrate deformable mirror. A calibrated system for this project means having the deformable mirror imaged onto the wavefront sensor, with the center of the mirror on the center of the WFS. Also, a flat wavefront, which is achieved by eliminating the tip/tilt of the mirror. Eliminating the tip/tilt reduces the RMS amplitude to a value below 0.200 microns. This causes the wavefront to fold in on itself. We set up a focal plane detector behind beam splitter as a demonstration of what would be seen if this were used with a telescope. The image that should be seen on the focal plane detector is the beam with a diffraction pattern called and Airy Function. The AO system is now ready to be used to teach others about adaptive optics.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration technique of wall shear stress sensors using oscillating plate

Disclosed are a system and methods for calibrating wall shear stress sensors. The system includes an oscillating plate coupled to an actuator and mounted on a rolling elements, and one or more sensors coupled to a height adjusting device. The system can further comprise a height control rod coupled to a height control base and a sensor holder configured to house the one or more sensors and supported on a connector, the connector configured to be rotatably disposed about the height control rod. The system can be calibrated by causing the actuator to oscillate the oscillating plate at a frequency, sensing, using the one or more sensors, shear stress at a wall, the shear stress at the wall being associated with a velocity field, and determining a theoretical wall shear stress based on fluid properties, the frequency, and the height of the one or more sensors above the oscillating plate.

Freidkes, Brett R.↗

Theoretical study on the top- and enclosed-contacted single-layer MoS{sub 2} piezotronic transistors

Recently, the piezotronic effect has been observed in two-dimensional single-layer MoS{sub 2} materials, which have potential applications in force and pressure triggered or controlled electronic devices, sensors, and human-machine interfaces. However, classical theory faces the difficulty in explaining the mechanism of the piezotronic effect for the top- and enclosed-contacted MoS{sub 2} transistors, since the piezoelectric charges are assumed to exist only at the edge of the MoS{sub 2} flake that is far from the electronic transport pathway. In the present study, we identify the piezoelectric charges at the MoS{sub 2}/metal-MoS{sub 2} interface by employing both the density functional theory and finite element method simulations. This interface is on the transport pathway of both top- and enclosed-contacted MoS{sub 2} transistors, thus it is capable of controlling their transport properties. This study deepens the understanding of piezotronic effect and provides guidance for the design of two-dimensional piezotronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recovery Act: Federspiel Controls (now Vigilent) and State of California Department of General Services Data Center Energy Efficient Cooling Control Demonstration. Final technical project report

Eight State of California data centers were equipped with an intelligent energy management system to evaluate the effectiveness, energy savings, dollar savings and benefits that arise when powerful artificial intelligence-based technology measures, monitors and actively controls cooling operations. Control software, wireless sensors and mesh networks were used at all sites. Most sites used variable frequency drives as well. The system dynamically adjusts temperature and airflow on the fly by analyzing real-time demands, thermal behavior and historical data collected on site. Taking into account the chaotic interrelationships of hundreds to thousands of variables in a data center, the system optimizes the temperature distribution across a facility while also intelligently balancing loads, outputs, and airflow. The overall project will provide a reduction in energy consumption of more than 2.3 million kWh each year, which translates to $240,000 saved and a reduction of 1.58 million pounds of carbon emissions. Across all sites, the cooling energy consumption was reduced by 41%. The average reduction in energy savings across all the sites that use VFDs is higher at 58%. Before this case study, all eight data centers ran the cooling fans at 100% capacity all of the time. Because of the new technology, cooling fans run at the optimum fan speed maintaining stable air equilibrium while also expending the least amount of electricity. With lower fan speeds, the life of the capital investment made on cooling equipment improves, and the cooling capacity of the data center increases. This case study depicts a rare technological feat: The same process and technology worked cost effectively in eight very different environments. The results show that savings were achieved in centers with diverse specifications for the sizes, ages and types of cooling equipment. The percentage of cooling energy reduction ranged from 19% to 78% while keeping temperatures substantially within the limits recommended by the American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) for data center facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TESTING OF THE RADBALL TECHNOLOGY AT SAVANNAH RIVER NATIONAL LABORATORY

The United Kingdom's National Nuclear Laboratory (NNL) has developed a remote, nonelectrical, radiation-mapping device known as RadBall (patent pending), which offers a means to locate and quantify radiation hazards and sources within contaminated areas of the nuclear industry. Positive results from initial deployment trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and the anticipated future potential use of RadBall throughout the U.S. Department of Energy Complex have led to the NNL partnering with the Savannah River National Laboratory (SRNL) to further test, underpin, and strengthen the technical performance of the technology. The study completed at SRNL addresses key aspects of the testing of the RadBall technology. The first set of tests was performed at Savannah River Nuclear Solutions Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics. The objective of these preliminary tests was to identify the optimal dose and collimator thickness. The second set of tests involved a highly contaminated hot cell. The objective of this testing was to characterize a hot cell with unknown radiation sources. The RadBall calibration experiments and hot cell deployment were successful in that for each trial radiation tracks were visible. The deployment of RadBall can be accomplished in different ways depending on the size and characteristics of the contaminated area (e.g., a hot cell that already has a crane/manipulator available or highly contaminated room that requires the use of a remote control device with sensor and video equipment to position RadBall). This report also presents SRNL-designed RadBall accessories for future RadBall deployment (a harness, PODS, and robot).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

APTAMER-BASED SERRS SENSOR FOR THROMBIN DETECTION

We describe an aptamer-based Surface Enhanced Resonance Raman Scattering (SERRS) sensor with high sensitivity, specificity, and stability for the detection of a coagulation protein, human a-thrombin. The sensor achieves high sensitivity and a limit of detection of 100 pM by monitoring the SERRS signal change upon the single step of thrombin binding to immobilized thrombin binding aptamer. The selectivity of the sensor is demonstrated by the specific discrimination of thrombin from other protein analytes. The specific recognition and binding of thrombin by the thrombin binding aptamer is essential to the mechanism of the aptamer-based sensor, as shown through measurements using negative control oligonucleotides. In addition, the sensor can detect 1 nM thrombin in the presence of complex biofluids, such as 10% fetal calf serum, demonstrating that the immobilized, 5{prime}-capped, 3{prime}-capped aptamer is sufficiently robust for clinical diagnostic applications. Furthermore, the proposed sensor may be implemented for multiplexed detection using different aptamer-Raman probe complexes.

59 BASIC BIOLOGICAL SCIENCES↗

Forewarning of Failure in Complex Systems

As the critical infrastructures of the United States have become more and more dependent on public and private networks, the potential for widespread national impact resulting from disruption or failure of these networks has also increased. Securing the nation s critical infrastructures requires protecting not only their physical systems but, just as important, the cyber portions of the systems on which they rely. A failure is inclusive of random events, design flaws, and instabilities caused by cyber (and/or physical) attack. One such domain is failure in critical equipment. A second is aging bridges. We discuss the workings of such a system in the context of the necessary sensors, command and control and data collection as well as the cyber security efforts that would support this system. Their application and the implications of this computing architecture are also discussed, with respect to our nation s aging infrastructure.

99 GENERAL AND MISCELLANEOUS↗