Physics design of the in-vessel collection optics for the ITER electron cyclotron emission diagnostic

Measurement of the electron cyclotron emission (ECE) is one of the primary diagnostics for electron temperature in ITER. In-vessel, in-vacuum, and quasi-optical antennas capture sufficient ECE to achieve large signal to noise with microsecond temporal resolution and high spatial resolution while maintaining polarization fidelity. Two similar systems are required. One views the plasma radially. The other is an oblique view. Both views can be used to measure the electron temperature, while the oblique is also sensitive to non-thermal distortion in the bulk electron distribution. The in-vacuum optics for both systems are subject to degradation as they have a direct view of the ITER plasma and will not be accessible for cleaning or replacement for extended periods. Blackbody radiation sources are provided for in situ calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive nonlocal means filtering based on local noise level for CT denoising

Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analytical noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the shape and peak frequency of the noise power spectrum better than commercial smoothing kernels, and indicate that the spatial resolution at low contrast levels is not significantly degraded. Both the subjective evaluation using the ACR phantom and the objective evaluation on a low-contrast detection task using a CHO model observer demonstrate an improvement on low-contrast performance. The GPU implementation can process and transfer 300 slice images within 5 min. On patient data, the adaptive NLM algorithm provides more effective denoising of CT data throughout a volume than standard NLM, and may allow significant lowering of radiation dose. After a two week pilot study of lower dose CT urography and CT enterography exams, both GI and GU radiology groups elected to proceed with permanent implementation of adaptive NLM in their GI and GU CT practices. Conclusions: This work describes and validates a computationally efficient technique for noise map estimation directly from CT images, and an adaptive NLM filtering based on this noise map, on phantom and patient data. Both the noise map calculation and the adaptive NLM filtering can be performed in times that allow integration with clinical workflow. The adaptive NLM algorithm provides effective denoising of CT data throughout a volume, and may allow significant lowering of radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fiber optic quench detection via optimized Rayleigh Scattering in high-field YBCO accelerator magnets

Yttrium barium copper oxide (YBCO) coated conductors are known for their ability to operate in the superconducting state at relatively high temperatures, even above the boiling point of liquid nitrogen (77 K). When these same conductors are operated at lower temperatures, they are able to operate in much higher magnetic fields than traditional superconductors like NiTi or Nb 3 Sn. Thus, YBCO superconducting magnets are one of the primary options for generating the high magnetic fields needed for future high energy physics devices. Due to slow quench propagation, quench detection remains one of the primary limitations to YBCO magnets. Fiber optic sensing, based upon Rayleigh scattering, has the potential for spatial resolution approaching the wavelength of light, or very fast temporal resolution at low spatial resolution, and a continuum of combinations in between. This project has studied, theoretically and experimentally, YBCO magnets and Rayleigh scattering quench detection systems to demonstrate feasibility of the systems for YBCO quench protection systems. Under this grant an experimentally validated 3D quench propagation model was used to accurately define the acceptable range of spatial and temporal resolutions for effective quench detection in YBCO magnets and to evaluate present-day and potentially improved YBCO conductors. The data volume and speed requirements for quench detection via Rayleigh scattering required the development of a high performance fiber optic based quench detection/data acquisition system and its integration with an existing voltage tap/thermo-couple based system. In this project, optical fibers are tightly co-wound into YBCO magnet coils, with the fiber on top of the conductor as turn-to-turn insulation. Local changes in the temperature or strain of the conductor are sensed by the optical fiber, which is in close thermal and mechanical contact with the conductor. Intrinsic imperfections in the fiber reflect Rayleigh backscattered laser signals that are shifted by the changes in the fiber that are induced by a local change in the YBCO temperature or strain. One goal of this project was to show that modern technology can be used to interrogate the signals from a (very expensive) YBCO magnet to detect an impending quench in time to protect it from self-destruction. The results show that Rayleigh-backscattering interrogated optical fibers (RIOF) have significant advantages over traditional techniques, including very high spatial resolution and the ability to detect a hot-spot well before the peak local temperature becomes so high that the conductor can be damaged. RIOF quench detection is intrinsically faster than voltage taps, and this intrinsic advantage is greater as the coil size and/or current margin increases. We describe the development and testing program performed under the grant.

43 PARTICLE ACCELERATORS↗

HPC-EPIC for High Resolution Simulations of Environmental and Sustainability Assessment

Multiple concerns over the impact of wide scale changes in land management have motivated comprehensive analyses of environmental sustainability of food and biofuel production. These call for high-resolution, spatial-temporal information of lands using tools that enable comprehensive analyses of natural resources for decision-making. Most agroecosystem simulation models are point models with a user interface that allows users to provide inputs and examine results for agricultural field scale analyses, and they aren’t able to meet the needs of the regional and national simulation with high spatial resolutions. We describe an efficient computational approach over deployment of the Environmental Policy Integrated Climate (EPIC) model at high-resolution scales using a high performance computing (HPC) technique in this study. We concentrate on an integrated procedure for executing millions of simulations required, but also address building databases for model initialization and forcing the simulations, and post-processing model outputs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Neutron and X-Ray Diffraction Studies of Advanced Materials

The selection of articles in the special topic 'Neutron and X-Ray Studies of Advanced Materials' is based on the materials presented during the TMS 2009 annual meeting in San Francisco, CA, February 15-19, 2009. The development of ultrabrilliant third-generation synchrotron X-ray sources, together with advances in X-ray optics, has created intense X-ray microbeams, which provide the best opportunities for in-depth understanding of mechanical behavior in a broad spectrum of materials. Important applications include ultrasensitive elemental detection by X-ray fluorescence/absorption and microdiffraction to identify phase and strain with submicrometer spatial resolution. X-ray microdiffraction is a particularly exciting application compared with alternative probes of crystalline structure, orientation, and strain. X-ray microdiffraction is nondestructive with good strain resolution, competitive or superior spatial resolution in thick samples, and with the ability to probe below the sample surface. Moreover, the high-energy X-ray diffraction technique provides an effective tool for characterizing the mechanical and functional behavior in various environments (temperature, stress, and magnetic field). At the same time, some neutron diffraction instruments constructed mainly for the purpose of engineering applications can be found at nearly all neutron facilities. The first generation-dedicated instruments designed for studying in-situ mechanical behavior have been commissioned and used, and industrial standards for reliable and repeatable measurements have been developed. Furthermore, higher penetration of neutron beams into most engineering materials provides direct measurements on the distribution of various stresses (i.e., types I, II, and III) beneath the surface up to several millimeters, even tens of millimeters for important industrial components. With X-ray and neutron measurements, it is possible to characterize material behavior at different length scales. It is predicted that the application of these techniques, in combination with theoretical simulations and numerical modeling, will lead to major breakthroughs in materials science in the foreseeable future, which will contribute to the development of materials technology and industrial innovation. Specifically, the use of these techniques provides bulk material properties that further augment new characterization tools including the increased use of atom probe tomography and high-resolution transmission electron microscopy systems. The combination of these techniques greatly assists the material property models that address multi-length-scale mechanisms. Different applications of diffuse scattering for understanding the fundamental materials properties are illustrated in the articles of Welberry et al., Goossens and Welberry, Campbell, Abe et al., Gilles et al., and Zhang et al. Analysis of thin films and two-dimensional structures is described in the articles of Gramlich et al., Brock et al., Vigliante et al., Kuzel et al., and Davydok et al. Recent advances in the line profile analysis are represented by the the articles of Scardi et al., Ungar et al., and Woo et al. Characterization of modern alloys is presented by the articles of Wollmershauser et al., Eidenberger et al., Garlea et al., Jia et al., Soulami et al., Wilson et al., and Wang et al. The collected articles are written by different scientific X-ray and neutron research groups. They represent a general trend in the development and application of diffraction techniques all over the world.

36 MATERIALS SCIENCE↗

Spatial Proteomics towards cellular Resolution

Introduction: Spatial biology is an emerging interdisciplinary field facilitating biological discoveries through the use of spatial omics technologies. Recent advancements in spatial transcriptomics, spatial genomics (e.g. genetic mutations and epigenetic marks), multiplexed immunofluorescence, and spatial metabolomics/lipidomics have enabled high-resolution spatial profiling of gene expression, genetic variation, protein expression, and metabolites/lipids profiles in tissue. These developments contribute to a deeper understanding of the spatial organization within tissue microenvironments at the molecular level. Areas covered: This report provides an overview of the untargeted, bottom-up mass spectrometry (MS)-based spatial proteomics workflow. It highlights recent progress in tissue dissection, sample processing, bioinformatics, and liquid chromatography (LC)-MS technologies that are advancing spatial proteomics toward cellular resolution. Expert opinion: The field of untargeted MS-based spatial proteomics is rapidly evolving and holds great promise. To fully realize the potential of spatial proteomics, it is critical to advance data analysis and develop automated and intelligent tissue dissection at the cellular or subcellular level, along with high-throughput LC-MS analyses of thousands of samples. In conclusion, achieving these goals will necessitate significant advancements in tissue dissection technologies, LC-MS instrumentation, and computational tools.

59 BASIC BIOLOGICAL SCIENCES↗

Modified Visible and Infrared Optical Design for the ITER Upper Ports

This document reports the results of a follow-on optical design study of visible-light and infrared optics for the ITER upper ports, performed by LLNL under contract for the US ITER Project Office. The major objectives of this work are to move the viewing aperture closer to the plasma so that the optical path does not cut through any adjacent blanket shield module other than the module designated for the port; move optics forward into the port tube to increase the aperture size and therefore improve the spatial resolution; assess the trade-off between spatial resolution and spatial coverage by reducing the field of view; and create a mechanical model with a neutron labyrinth. Here we show an optical design incorporating all these aspects. The new design fits into a 360 mm ID tube, as did the previous design. The entrance aperture is increased from 10 mm to 21 mm, with a corresponding increase in spatial resolution. The Airy disk diameter for 3.8 {micro}m wavelength IR light is 5.1 mm at the most distant target point in the field of view. The field of view is reduced from 60 toroidal degrees (full toroidal coverage with 6 cameras) to 50 toroidal degrees. The 10 degrees eliminated are those nearest the camera, which have the poorest view of the divertor plate and in fact saw little of the plate. The Cassegrain telescope that was outside the vacuum windows in the previous design is now in vacuum, along with lenses for visible light. The Cassegrain for visible light is eliminated. An additional set of optical relay lenses is added for the visible and for the IR.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging x-ray Thomson scattering spectrometer design and demonstration (invited)

In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connecting Galactic Outflows and Star Formation: Inferences from Hα Maps and Absorption-line Spectroscopy at 1 ≲ z ≲ 1.5

We investigate the connection between galactic outflows and star formation using two independent data sets covering a sample of 22 galaxies between 1 ≲ z ≲ 1.5. The Hubble Space Telescope WFC3/G141 grism provides low spectral resolution, high spatial resolution spectroscopy yielding Hα emission-line maps from which we measure the spatial extent and strength of star formation. In the rest-frame near-UV, Keck/DEIMOS observes Fe ii and Mg ii interstellar absorption lines, which provide constraints on the intensity and velocity of the outflows. We compare outflow properties from individual and composite spectra with the star formation rate (SFR) and SFR surface density (Σ{sub SFR}), as well as the stellar mass and specific SFR (sSFR). The Fe ii and Mg ii equivalent widths (EWs) increase with both SFR and Σ{sub SFR} at ≳3σ significance, while the composite spectra show larger Fe ii EWs and outflow velocities in galaxies with higher SFR, Σ{sub SFR}, and sSFR. Absorption-line profiles of the composite spectra further indicate that the differences between subsamples are driven by outflows rather than the interstellar medium. While these results are consistent with those of previous studies, the use of Hα images makes them the most direct test of the relationship between star formation and outflows at z > 1 to date. Future facilities such as the James Webb Space Telescope and the upcoming Extremely Large Telescopes will extend these direct, Hα-based studies to lower masses and SFRs, probing galactic feedback across orders of magnitude in galaxy properties and augmenting the correlations we find here.

47 OTHER INSTRUMENTATION↗

Combined Chemical and Topographic Imaging at Atmospheric Pressure via Microprobe Laser Desorption/Ionization Mass Spectrometry-Atomic Force Microscopy

The operational characteristics and imaging performance are described for a new instrument comprising an atomic force microscope (AFM) coupled with a pulsed laser and a linear ion trap mass spectrometer. The AFM operating mode is used to produce topographic surface images having nanometer-scale spatial and height resolution. Spatially resolved mass spectra of ions, produced from the same surface via microprobe-mode laser desorption/ionization at atmospheric pressure, are then used to create a 100 x 100 m chemical image. The effective spatial resolution of the image (~2 m) was constrained by the limit of detection (estimated to be 109 1010 ions) rather than by the diameter of the focused laser spot or the step size of the AFM sample stage. Thus, it is expected that improvements in imaging performance can be realized by implementation of post-ionization methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Filterscope diagnostic system on the Experimental Advanced Superconducting Tokamak (EAST)

A filterscope diagnostic system has been mounted to observe the line emission and visible bremsstrahlung emission from plasma on the experimental advanced superconducting tokamak during the 2014 campaign. By this diagnostic system, multiple wavelengths including D{sub α} (656.1 nm), D{sub γ} (433.9 nm), He II (468.5 nm), Li I (670.8 nm), Li II (548.3 nm), C III (465.0 nm), O II (441.5 nm), Mo I (386.4 nm), W I (400.9 nm), and visible bremsstrahlung radiation (538.0 nm) are monitored with corresponding wavelength filters. All these multi-channel signals are digitized at up to 200 kHz simultaneously. This diagnostic plays a crucial role in studying edge localized modes and H-mode plasmas, due to the high temporal resolution and spatial resolution that have been designed into it.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Inventory of AI-ready Benchmark Data for US Fires, Heatwaves, and Droughts

Extreme weather events, including fires, heatwaves, and droughts, have significant impacts on earth, environmental, and energy systems. Mechanistic and predictive understanding, as well as probabilistic risk assessment of these extreme weather events, are crucial for detecting, planning for, and responding to these extremes. Records of extreme weather events provide an important data source for understanding present and future extremes, but the existing data needs preprocessing before it can be used for analysis. Moreover, there are many nonstandard metrics defining the levels of severity or impacts of extremes. In this study, we compile a comprehensive benchmark data inventory of extreme weather events, including fires, heatwaves, and droughts. The dataset covers the period from 2001 to 2020 with a daily temporal resolution and a spatial resolution of 0.5°×0.5° (~55km×55km) over the continental United States (CONUS), and a spatial resolution of 1km × 1km over the Pacific Northwest (PNW) region, together with the co-located and relevant meteorological variables. By exploring and summarizing the spatial and temporal patterns of these extremes in various forms of marginal, conditional, and joint probability distributions, we gain a better understanding of the characteristics of climate extremes. The resulting AI/ML-ready data products can be readily applied to ML-based research, fostering and encouraging AI/ML research in the field of extreme weather. This study can contribute significantly to the advancement of extreme weather research, aiding researchers, policymakers, and practitioners in developing improved preparedness and response strategies to protect communities and ecosystems from the adverse impacts of extreme weather events. Usage Notes We presented a long term (2001-2020) and comprehensive data inventory of historical extreme events with daily temporal resolution covering the separate spatial extents of CONUS (0.5°×0.5°) and PNW(1km×1km) for various applications and studies. The dataset with 0.5°×0.5° resolution for CONUS can be used to help build more accurate climate models for the entire CONUS, which can help in understanding long-term climate trends, including changes in the frequency and intensity of extreme events, predicting future extreme events as well as understanding the implications of extreme events on society and the environment. The data can also be applied for risk accessment of the extremes. For example, ML/AI models can be developed to predict wildfire risk or forecast HWs by analyzing historical weather data, and past fires or heateave , allowing for early warnings and risk mitigation strategies. Using this dataset, AI-driven risk assessment models can also be built to identify vulnerable energy and utilities infrastructure, imrpove grid resilience and suggest adaptations to withstand extreme weather events. The high-resolution 1km×1km dataset ove PNW are advantageous for real-time, localized and detailed applications. It can enhance the accuracy of early warning systems for extreme weather events, helping authorities and communities prepare for and respond to disasters more effectively. For example, ML models can be developed to provide localized HW predictions for specific neighborhoods or cities, enabling residents and local emergency services to take targeted actions; the assessment of drought severity in specific communities or watersheds within the PNW can help local authorities manage water resources more effectively.

Lin, Xinming↗

Aberration corrected scanning transmission electron microscopy and electron energy loss spectroscopy studies of epitaxial Fe/MgO/(001)Ge heterostructures

Aberration correction in the scanning transmission electron microscope combined with electron energy loss spectroscopy allows simultaneous mapping of the structure, the chemistry and even the electronic properties of materials in one single experiment with spatial resolutions of the order of one Angstrom. Here the authors will apply these techniques to the characterization of epitaxial Fe/MgO/(001)Ge and interfaces with possible applications for tunneling junctions, and the authors will show that epitaxial MgO films can be grown on a (001)Ge substrates by molecular beam epitaxy and how it is possible to map the chemistry of interfaces with atomic resolution. Epitaxial growth of insulator oxides on semiconductors constitutes a key issue within the field of electronics, and a considerably large effort has been devoted to harness the growth of high-k oxides on Si. Ge, due to its high electronic and hole mobility, is a very interesting alternative as a potential substrate for future high performance complementary metal-oxide-semiconductor field-effect transistors. However, a major issue is to avoid the high resistivity at the source and drain contacts ensuing from the pinning of the Fermi level at the valence-band maximum. It has been suggested that this problem could be fixed by depositing a thin insulating tunneling barrier between the Ge substrate and the metal contacts. In this case, single crystal epitaxy would represent an additional benefit, since it would lead to a reduction of interfacial defects and improved performance of the tunneling barrier. MgO has been suggested to fulfill such requisites. Furthermore, MgO has been demonstrated to be a good substrate for epitaxial growth of transition metals thin films, such as Fe and Co, thus avoiding the potential problem of chemical reactivity with Ge. In such a scenario, epitaxial deposition of high quality MgO films on Ge substrates is highly desirable. But in addition, successful epitaxial growth of MgO on a semiconductor would also constitute a plus for applications in spintronics, since the injection of a spin polarized current from a ferromagnetic electrode to a non-magnetic semiconductor requires the presence of a potential barrier. MgO represents a convenient choice because the symmetry filtering properties at the interface with transition metals would allow an efficient spin filtering effect. For this approach to succeed, a suitable semiconducting substrate where MgO can be grown epitaxially must be found. And again, while GaAs and Si have been investigated for such role, Ge has not received much attention so far. In this study the authors report on the atomic resolution characterization of high quality interfaces in Fe/MgO/(001)Ge heterostructures. The study of the defects, the inhomogeneities and the interface structure of such junctions is a must to pave the way toward future applications. For this aim, the combination of scanning transmission electron microscopy (STEM) and electron energy loss spectroscopy (EELS) is a most useful tool, since it allows these features to be probed with atomic resolution. Spherical aberration correction in the STEM allows for increased contrast, allowing even single atoms to be detected both in imaging and spectroscopy.

36 MATERIALS SCIENCE↗

On the use of peak-force tapping atomic force microscopy for quantification of the local elastic modulus in hardened cement paste

A surface of epoxy-impregnated hardened cement paste was investigated using a novel atomic force microscopy (AFM) imaging mode that allows for the quantitative mapping of the local elastic modulus. The analyzed surface was previously prepared using focussed ion beam milling. The same surface was also characterized by electron microscopy and energy-dispersive X-ray spectroscopy. We demonstrate the capability of this quantitative nanomechanical mapping to provide information on the local distribution of the elastic modulus (from about 1 to about 100 GPa) with a spatial resolution in the range of decananometers, that corresponds to that of low-keV back-scattered electron imaging. Despite some surface roughness which affects the measured nanomechanical properties it is shown that topography, adhesion and Young's modulus can be clearly distinguished. The quantitative mapping of the local elastic modulus is able to discriminate between phases in the cement paste microstructure that cannot be distinguished from the corresponding back-scattered electron images.

36 MATERIALS SCIENCE↗

Radiation stability of CsBr:Eu needle image plates

Needle image plates (NIPs) based on CsBr:Eu are a good alternative to the BaFBr:Eu powder image plates due to their higher sensitivity and improved spatial resolution. The x-ray radiation stability of the NIPs produced by Agfa Gevaert was investigated and it was found that the radiation stability of the optimized NIPs is as high as that of the commercial CsI:Tl single crystals and much higher than reported in literature for the CsBr:Eu NIPs. The dependence of the sensitivity of the NIPs on the accumulated dose was determined for three different types of x-ray irradiation. It is shown that degradation of the sensitivity starts at about 10 Gy and it is the strongest for the most hard x-ray beam. If the energy absorbed by a NIP is taken into account, the degradation does not depend on the hardness of the applied x-ray beam. It is suggested that the main reason for the observed high radiation stability of the CsBr:Eu NIPs is the use of the oxygen-free Eu{sup 2+}-containing precursor CsEuBr{sub 3} for the doping in the manufacturing process.

36 MATERIALS SCIENCE↗

Tailoring a plasma focus as hard x-ray source for imaging

An investigation on temporal and spatial properties of hard x-rays (15-88 keV) emitted in a 5.3 kJ plasma focus using Si pin diodes and a pinhole camera is reported. The maximum yield of hard x-rays of 15-88 keV range is estimated about 4.7 J and corresponding efficiency for x-ray generation is 0.09%. The x-rays with energy >15 keV have 15-20 ns pulse duration and approx1 mm source size. This radiation is used for contact x-ray imaging of biological and compound objects and spatial resolution of approx50 mum is demonstrated.