Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standardization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Improving perfusion defect detection with respiratory motion correction in cardiac SPECT at standard and reduced doses

Background: In cardiac SPECT perfusion imaging, respiratory motion can cause non-uniform blurring in the reconstructed myocardium. We investigate the potential benefit of respiratory correction with respiratory-binned acquisitions, both at standard dose and at reduced dose, for defect detection and for left ventricular (LV) wall resolution. Methods: We applied two reconstruction methods for respiratory motion correction: post-reconstruction motion correction (PMC) and motion-compensated reconstruction (MCR), and compared with reconstruction without motion correction (Non-MC). We quantified the presence of perfusion defects in reconstructed images by using the total perfusion deficit (TPD) scores and conducted receiver-operating-characteristic (ROC) studies using TPD. We quantified the LV spatial resolution by using the FWHM of its cross-sectional intensity profile. Results: The values in the area-under-the-ROC-curve (AUC) achieved by MCR, PMC, and Non-MC at standard dose were 0.835, 0.830, and 0.798, respectively. Similar AUC improvements were also obtained by MCR and PMC over Non-MC at 50%, 25%, and 12.5% of full dose. Improvements in LV resolution were also observed with motion correction. Conclusions: Respiratory-binned acquisitions can improve perfusion-defect detection accuracy over traditional reconstruction both at standard dose and at reduced dose. Motion correction may contribute to achieving further dose reduction while maintaining the diagnostic accuracy of traditional acquisitions. [French] French Abstract: Contexte: Les mouvements respiratoires peuvent entrainer des artefacts de uniformité lors de la reconstruction des images de perfusion myocardique en SPECT. Dans cet article, nous rapportons nos résultats sur le bénéfice potentiel du « gating » respiratoire avec des doses standards et réduites de radio-pharmaceutiques pour la détection des anomalies de perfusion et les mesures de la paroi ventriculaire gauche. Méthodes: Nous avons appliqué deux méthodes de reconstruction pour la correction du mouvement respiratoire: la première fait appel a une correction après reconstruction des images (PMC) ; la seconde fait appel à la correction des images avant reconstruction (MRC). Les deux approches ont été comparées à la reconstruction sans correction de mouvement (Non-MC). Nous avons quantifié les déficits de perfusion myocardiques sur les images reconstruites avec le système des scores de déficit de perfusion et analysé les résultats en utilisant les courbes ROC. Nous avons quantifié la résolution spatiale du VG en utilisant le FWHM du profil d’intensité de sa section transversale. Résultats: Les valeurs des surfaces en dessous des courbes ROC (AUC) obtenues par MCR, PMC et Non-MC avec doses standard de radio-pharmaceutiques étaient de 0,835, 0,830 et 0,798, respectivement. Des améliorations similaires de l’AUC ont également été obtenues par MCR et PMC sur Non-MC avec 50%, 25% et 12,5% des doses entières. Les mesures de résolution spatiale de la paroi du VG ont également été améliorées avec la correction des mouvements respiratoires. Conclusions: La correction des images de perfusion myocardiques en SPECT par « gating » respiratoire paraît améliorer la quantification des déficits perfusionels à la fois à dose standard et à dose réduite de radio-pharmaceutiques. L’application de cette correction devrait permettre de réduire les doses de radio-pharmaceutiques utilisées tout en maintenant la précision diagnostique des acquisitions traditionnelles. [Spanish] Spanish Abstract: Antecedentes: En los estudios de perfusión cardiaca por SPECT, los movimientos respiratorios pueden causar distorsión no uniforme en el miocardio reconstruido. Investigamos el beneficio potencial de la corrección respiratoria con adquisición de imágenes sincronizadas con la respiración, tanto a dosis estándar como a dosis reducida, para detección de defectos y para resolución de pared de ventrículo izquierdo (VI). Métodos: Aplicamos dos métodos de reconstrucción para corrección de movimientos respiratorios: Corrección de movimiento post reconstrucción (PMC) y reconstrucción compensada a movimiento (MCR), y los comparamos con la reconstrucción sin corrección de movimiento (Non-MC). Cuantificamos la presencia de defectos de perfusión en las imágenes reconstruidas usando los scores de déficit total de perfusión (TPD) y análisis ROC usando el TPD. Cuantificamos la resolución espacial del VI usando la anchura a media altura de su perfil de intensidad transversal. Resultados: Los valores en el área bajo la curva ROC (ABC) obtenidos por MCR, PMC y Non-MC a dosis estándar fueron 0.835, 0.830 y 0.798, respectivamente. Mejorías similares del ABC también se obtuvieron por MCR y PMC, sobre Non-MC a 50%, 25% y 12.5% de la dosis completa. Las mejorías en la resolución del VI fueron observadas también con corrección del movimiento. Conclusiones: Las adquisiciones sincronizadas con la respiración pueden mejorar la precisión de la detección de defectos de perfusión sobre las reconstrucciones tradicionales tanto a dosis estándar como a dosis reducida. La corrección de movimiento puede contribuir a lograr mayor reducción de la dosis manteniendo la precisión diagnóstica de las adquisiciones tradicionales. [Chinese] Chinese Abstract: 背景: 在心脏 SPECT 灌注成像中, 呼吸运动会导致心肌重建的不均匀模糊。我们研究了无论是标准剂量还是减少剂量的情况下, 呼吸跟踪采集的呼吸校正用于图像缺损检测和左心室 (LV) 室壁分辨率的潜在益处。 方法: 我们使用了两种呼吸运动校正的重建方法:重建后运动校正 (PMC) 和运动补偿重建 (MCR), 并与没有运动校正的重建 (Non-MC) 进行比较。 通过总灌注缺损 (TPD) 评分和其接受者操作特性曲线 (ROC) 来量化重建图像中的灌注缺陷。通过LV横截面强度分布的 FWHM来量化 LV 空间分辨率。 结果: MCR, PMC 和 Non-MC 在标准剂量下所获得的 ROC 曲线下面积 (AUC) 的值分别为0.835, 0.830 和 0.798。 在全剂量下, MCR, PMC和 Non-MC也获得类似的 AUC 提高, 分别为 50%, 25% 和 12.5%。 在运动校正下, LV的分辨率也得到了改善。 结论: 在标准剂量和减少剂量的情况下, 呼吸跟踪采集可以改善灌注缺损检测的准确性。 运动校正可能有助于进一步实现减少剂量的目标, 同时保证通过传统检测方法的诊断准确性。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Breast Sentinel Lymph Node Coverage by Standard Radiation Therapy Fields

Background: Biopsy of the breast sentinel lymph node (SLN) is now a standard staging procedure for early-stage invasive breast cancer. The anatomic location of the breast SLN and its relationship to standard radiation fields has not been described. Methods and Materials: A retrospective review of radiotherapy treatment planning data sets was performed in patients with breast cancer who had undergone SLN biopsy, and those with a surgical clip at the SLN biopsy site were identified. The location of the clip was evaluated relative to vertebral body level on an anterior-posterior digitally reconstructed radiograph, treated whole-breast tangential radiation fields, and standard axillary fields in 106 data sets meeting these criteria. Results: The breast SLN varied in vertebral body level position, ranging from T2 to T7 but most commonly opposite T4. The SLN clip was located below the base of the clavicle in 90%, and hence would be excluded from standard axillary radiotherapy fields where the inferior border is placed at this level. The clip was within the irradiated whole-breast tangent fields in 78%, beneath the superior-posterior corner multileaf collimators in 12%, and outside the tangent field borders in 10%. Conclusions: Standard axillary fields do not encompass the lymph nodes at highest risk of containing tumor in breast cancer patients. Elimination of the superior-posterior corner MLCs from the tangent field design would result in inclusion of the breast SLN in 90% of patients treated with standard whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FIRST-YEAR SLOAN DIGITAL SKY SURVEY-II (SDSS-II) SUPERNOVA RESULTS: CONSTRAINTS ON NONSTANDARD COSMOLOGICAL MODELS

We use the new Type Ia supernovae discovered by the Sloan Digital Sky Survey-II supernova survey, together with additional supernova data sets as well as observations of the cosmic microwave background and baryon acoustic oscillations to constrain cosmological models. This complements the standard cosmology analysis presented by Kessler et al. in that we discuss and rank a number of the most popular nonstandard cosmology scenarios. When this combined data set is analyzed using the MLCS2k2 light-curve fitter, we find that more exotic models for cosmic acceleration provide a better fit to the data than the LAMBDACDM model. For example, the flat Dvali-Gabadadze-Porrati model is ranked higher by our information-criteria (IC) tests than the standard model with a flat universe and a cosmological constant. When the supernova data set is instead analyzed using the SALT-II light-curve fitter, the standard cosmological-constant model fares best. This investigation of how sensitive cosmological model selection is to assumptions about, and within, the light-curve fitters thereby highlights the need for an improved understanding of these unresolved systematic effects. Our investigation also includes inhomogeneous LemaItre-Tolman-Bondi (LTB) models. While our LTB models can be made to fit the supernova data as well as any other model, the extra parameters they require are not supported by our IC analysis. Finally, we explore more model-independent ways to investigate the cosmic expansion based on this new data set.

79 ASTRONOMY AND ASTROPHYSICS↗

DICHOTOMY OF SOLAR CORONAL JETS: STANDARD JETS AND BLOWOUT JETS

By examining many X-ray jets in Hinode/X-Ray Telescope coronal X-ray movies of the polar coronal holes, we found that there is a dichotomy of polar X-ray jets. About two thirds fit the standard reconnection picture for coronal jets, and about one third are another type. We present observations indicating that the non-standard jets are counterparts of erupting-loop H{alpha} macrospicules, jets in which the jet-base magnetic arch undergoes a miniature version of the blowout eruptions that produce major coronal mass ejections. From the coronal X-ray movies we present in detail two typical standard X-ray jets and two typical blowout X-ray jets that were also caught in He II 304 A snapshots from STEREO/EUVI. The distinguishing features of blowout X-ray jets are (1) X-ray brightening inside the base arch in addition to the outside bright point that standard jets have, (2) blowout eruption of the base arch's core field, often carrying a filament of cool (T {approx} 10{sup 4} - 10{sup 5} K) plasma, and (3) an extra jet-spire strand rooted close to the bright point. We present cartoons showing how reconnection during blowout eruption of the base arch could produce the observed features of blowout X-ray jets. We infer that (1) the standard-jet/blowout-jet dichotomy of coronal jets results from the dichotomy of base arches that do not have and base arches that do have enough shear and twist to erupt open, and (2) there is a large class of spicules that are standard jets and a comparably large class of spicules that are blowout jets.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-582: Evaluation of Standard Beam Delivery Devices in Proton Intracranial Radiosurgery

Purpose: To evaluate the use of standard apertures and range shifters for the treatment of brain metastasis in proton stereotactic radiosurgery. Methods: Five localized brain metastasis patients previously treated using our intracranial proton stereotactic radiosurgery procedure (i.e. with a custom aperture and bolus), were randomly selected from our patient cohort. The custom aperture and bolus treatment plans were used as the standard of care in this case and comparative treatment plans using the standard aperture and range shifter concept were generated. Gantry/table angle and the number of treatment beams were optimized as part of this study to evaluate the ability of the standard aperture/range shifter system to deliver a comparable treatment to the patient. Conformity index, homogeneity index, isodose volumes and integral dose were all evaluated to determine the degree of conformity of the plans created and for comparison to the custom aperture/bolus treatment modality. Results: The generated treatment plans demonstrated that the standard aperture and range shifter combination could be used to produce comparable conformity index and isodose volumes to the custom aperture/bolus case in four out of the five patients studied. In two of the patients a comparative conformity index was achieved by optimizing the angles of the 3 treatment beams, while in two of the cases 1 or 2 additional beams were required. Additionally, this system exhibited efficiency gains of 60-90% over the custom aperture bolus system in reducing the time necessary for treatment planning, device manufacture and QA. Conclusion: This work demonstrated that largely spherical shape of brain metastasis makes this target well suited to an application of standard apertures, while additionally providing efficiency gains in device manufacture and QA for treatment.

60 APPLIED LIFE SCIENCES↗

Should the Standard Count Be Excluded from Neutron Probe Calibration?

About 6 decades after its introduction, the neutron probe remains one of the most accurate methods for indirect measurement of soil moisture content. Traditionally, the calibration of a neutron probe involves the ratio of the neutron count in the soil to a standard count, which is the neutron count in the fixed environment such as the probe shield or a specially-designed calibration tank. The drawback of this count-ratio-based calibration is that the error in the standard count is carried through to all the measurements. An alternative calibration is to use the neutron counts only, not the ratio, with proper correction for radioactive decay and counting time. To evaluate both approaches, the shield counts of a neutron probe used for three decades were analyzed. The results show that the surrounding conditions have a substantial effect on the standard count. The error in the standard count also impacts the calculation of water storage and could indicate false consistency among replicates. The analysis of the shield counts indicates negligible aging effect of the instrument over a period of 26 years. It is concluded that, by excluding the standard count, the use of the count-based calibration is appropriate and sometimes even better than ratio-based calibration. The count-based calibration is especially useful for historical data when the standard count was questionable or absent

54 ENVIRONMENTAL SCIENCES↗

Leveraging the Higgs to Discover Physics Beyond the Standard Model (Final Technical Report)

The discovery of an apparently Standard Model-like Higgs at the Large Hadron Collider (LHC) heralds the start of a new era in particle physics. While the Higgs marks the completion of the Standard Model framework, it offers far more opportunities in the search for physics beyond the Standard Model. The Higgs boson raises a pressing theoretical problem known as the hierarchy problem: why is an elementary scalar particle so light when quantum corrections tie its mass to the highest energy scales? The Higgs also provides an unprecedented experimental opportunity as a bellwether of new physics: it may be merely the first of several states in the electroweak symmetry breaking sector, while its production and decays may provide unique evidence for additional particles. Research supported by this award leveraged the Higgs boson to explore new physics from both directions, developing novel approaches to solving the hierarchy problem posed by the Higgs boson and directly employing the Higgs as a new tool for discovery. Given that null results at the LHC and other experiments have begun to endanger conventional approaches to the hierarchy problem, research supported by the award identified original solutions to the hierarchy problem wherein the lightest degrees of freedom protecting the Higgs boson carry no Standard Model quantum numbers and thus evade existing searches. The PI's approach combined standard tools of quantum field theory with novel applications of the orbifold reduction of continuous symmetries to define the framework of "neutral naturalness'' and explore its experimental consequences across the energy, intensity, and cosmic frontiers. In employing the Higgs directly as a tool for discovery, research supported by this award articulated a systematic approach to searching for extensions of the Higgs sector at the LHC and pursued four key avenues through which the Higgs can be used to uncover new physics across a range of experiments: (1) as a direct final state probe; (2) as an indirect probe through its couplings; (3) as a portal to states neutral under the Standard Model; and (4) as a source of exotic processes in displaced decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010

This report documents the progress indicator (PI) process and analysis that Pacific Northwest National Laboratory (PNNL) developed to evaluate the potential energy savings from the application of ASHRAE Standard 90.1-2010 to building design and construction compared to the application of ASHRAE Standard 90.1-2004. The report describes PNNL’s EnergyPlus simulation framework, and the building prototype simulation models. The combined upgrades from ASHRAE Standard 90.1 -2004 to ASHRAE Standard 90.1-2010 are described, and consist of a total of 153 approved addenda (44 addenda to ASHRAE Standard 90.1-2007 and 109 addenda to ASHRAE Standard 90.1-2010). PNNL reviewed and considered all 153 addenda for quantitative analysis in the PI process. Fifty-three of those addenda are included in the quantitative analysis. This report provides information on the categorization of all of the addenda, a summary of the content, and a more in-depth explanation of the impact and modeling of the 53 identified addenda and their quantitative savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IESNA Standard 90.1-2007 Final Determination Quantitative Analysis

DOE conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the ASHRAE Standard 90.1-2007 would result in energy savings compared with buildings constructed to ASHRAE Standard 90.1-2004. The final analysis considered each of the 44 addenda to ASHRAE Standard 90.1-2004 that were included in ASHRAE Standard 90.1-2007. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from ASHRAE Standard 90.1-2004 were reviewed by DOE, and their combined impact on a suite of 15 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s final determination. However, out of the 44 addenda, 9 were preliminarily determined to have measurable and quantifiable impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photofission Validation Measurements for Active Interrogation Standards

Executive Summary PNNL has been developing technical standards for the detection of special nuclear material (SNM) in cargo containers using active interrogation approaches. Since the use of kilogram-scale quantities of SNM is impractical for standards testing, the work focused on designing surrogates that provided similar signature as the SNM. There are many active interrogation approaches to detect SNM; the standards development considered photofission, differential die-away and nuclear resonance fluorescence. Of these approaches, photofission currently carries the most interest. However, uncertainties in the photofission cross sections are as large as 50%, so that validation measurements are necessary to provide confidence that the surrogate will perform similarly to the SNM. This document describes approaches for conducting those validation measurements as well as provides a rough order-of-magnitude cost estimate for performing them. Photofission provides many observables for the detection of SNM. The standards development considered prompt neutrons, delayed neutrons and delayed gamma rays as possible detected particles. The surrogates, which consist primarily of depleted uranium (DU), were designed to reproduce the strength of these particles for a targeted quantity of 2 kg of HEU. Different surrogates are required for different measurement approaches because of the difference in cross section between 235 U and 238 U. For the standards validations, the relative strength of the detected particles for HEU and DU must be measured. To avoid measurements with kilogram-sized SNM, the validation approach is focused on two comparisons. In the first comparison, the relative rates for approximately 10 g samples of DU and HEU will be measured. This comparison will provide the basis for validating the relative strength of the detected particles for HEU and DU. In the second comparison, the relative rates for the approximately 10 g and 1 kg sample of DU will be measured. This comparison will enable the validation of secondary processes that occur after photofission that impact the measurement for kilogram-scale samples. For instance, for 2 kg of HEU, as much as 50% of the fission induced in the sample is induced from fission neutrons generated through photofission. There is a limited range of facilities in the U.S. that have both the necessary accelerator capability and the ability and willingness to handle SNM. Two such facilities, the Idaho Accelerator Center at Idaho State University and the Nuclear Engineering Program at the University of Michigan, have both expressed an interest in participating in such measurements. Both would need to amend their licensing to handle the 10 g of HEU proposed for these measurements. The rough order-of-magnitude cost estimate for all three validation measurements is $1.1M, spread over three years. Each of the three measurements could be performed separately, at approximately one-third of that cost. There are a number of critical assumptions in these cost estimate that will need to be confirmed before a more reliable cost estimate can be established. PNNL will manage the effort to ensure that the overall objective of the validation measurements can be achieved and will fabricate the 10 g samples of HEU and DU. Most the labor for the measurements will be provided by two collaborating universities as research opportunities for students. The successful completion of these validation measurements will reduce the uncertainties in the proposed standards from about 50% to 5%. The measurements would also provide some much-needed nuclear data on photofission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charting the unknown: A dive into the world of standards mapping

When you hear standards mapping what do you think about? For the Secure Software Central (SSC) project this means comparing our process to the National Institute of Standards and Technology’s (NIST) security control catalog. So how is it done? The project completed this summer can be broken down into three simple phases. Phase one consists of mapping the SSC process to the NIST’s security control catalog. While phase two entails mapping mitigations from a threat profile to NIST. Lastly phase three requires the creation of a knowledge base allowing for the reuse of controls across numerous projects This project presented a few different challenges: locating the correct control within the NIST catalog while correctly matching the proposed mitigations from the SSC team, accurately leveling the mitigation to the security level of the system, creating a toolbox to showcase a dataset of mitigations and standards to be used in current and future projects. each challenge allowed for opportunities in growth and understanding of how security controls can map to a governing set of standards. These standards maps are a crucial element to support the insights provided by the SSC team and allow the client to have confidence in the work being completed. My internship has allowed me to set and achieve many goals such as coming to understand that the field of cybersecurity truly is the right place for me. I have also learned that it’s ok to be wrong if you learn something from it. For significant accomplishments I have helped integrate standards mapping into the fabric of SSC. The field experience that I have gained such as interacting with the SSC team along with other senior staff and building a good rapport are crucial skills to. This time at PNNL has been an irreplaceable experience.

42 ENGINEERING↗

Assessment and Coordination of EVSE Cybersecurity Standards

Cybersecurity certification programs for Electric Vehicle Supply Equipment (EVSE) are fragmented due to no single certification covering all aspects of the device and additionally the existence of multiple programs and under different levels of regulation. These devices are also confronted by the intricate assembly of product software, firmware, and hardware. Devices contain both logical and physical interfaces. These multifaceted devices have vulnerabilities at many levels and interconnect with other potentially vulnerable systems including the electric vehicle, the cloud where data and payment information are stored, and the electric grid and electric grid equipment including utilities. Of the EVSE certification programs that are found, none are directly for the cybersecurity of EVSE. Many standards are for safety, specifically battery safety, some are cybersecurity standards for other types of equipment and can be modeled for EVSE. In specific, ISA/IEC 62443 is found to be significantly in line with EVSE security needs and will be used in future testing to certify EVSE and help guide the project to demonstrate where gaps exist, where strengths lie in the standard and how this can be used to lead the certification efforts in harmonizing EVSE cybersecurity standards. In addition, there are multiple efforts that are currently seeking to build EVSE standards or revise existing standards to address gaps. This effort is seeking to establish a cybersecurity program for EVSE that will inform customers and help increase the level of security across products and state EVSE procurements to achieve consistency across different jurisdictions.

33 ADVANCED PROPULSION SYSTEMS↗

Safety Codes and Standards Review and Gap Analysis for Applicability to Hydrogen Rail Refueling, Defueling, Maintenance, and Storage

Hydrogen-powered locomotives may present an alternative to diesel for achieving transportation-related decarbonization, energy security, and resilience goals. As an emerging technology, hydrogen locomotives may not have adequate representation in current safety codes and standards. NFPA 2 and other appropriate codes and standards were reviewed to identify technical gaps in the code for hydrogen rail defueling, refueling, maintenance, and storage. Several technical gaps pertaining to setback distances, allowable quantities, ventilation rates, and grounding have been identified. Fueling requirements can be informed by road vehicle standards but may need to be revised for larger quantity hydrogen locomotive systems. Since there are no hydrogen-specific locomotive design and safety standards, some aspects of diesel-based locomotive standards may apply. CGA G- 5.5 currently provides the most guidance on height, placement, orientation, and design of vent systems, while other standards emphasize the importance of shielding vent stacks and provide requirements for orientation of their discharge.

08 HYDROGEN↗

Metadata Standards for the NSE: Core Fields

This standard presents a core set of metadata fields required for each managed digital object within the Nuclear Security Enterprise (NSE). Metadata standardization is a critical enabler for two primary objectives: 1) effectively sharing data, documents, and other digital objects between NSE sites; and 2) supporting digital engineering through the digital thread at the object level. Standardization is necessary for both schemas and vocabularies, meaning that both field standards and value standards must be specified. This document serves as a foundational field standard, recommending a core set of fields that should be uniformly required for all managed digital objects within the NSE.

99 GENERAL AND MISCELLANEOUS↗

Developing Equivalent Surface Heat Transfer Input Parameters for Updated Standard 140/BESTEST Thermal Fabric Test Cases

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, is widely cited for evaluating software for use with performance-path energy efficiency analysis in conjunction with well-known energy-efficiency standards, including: ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. This paper summarizes recent work to develop improved equivalent surface heat transfer input parameters for the building thermal fabric comparative test cases that comprise a portion of Standard 140. The software-to-software comparative test method allows comparison of simulation results from a wide variety of building energy simulation programs to each other. In this type of test method, it is of great importance to specify inputs that are as well-equivalenced as possible to accommodate a wide variety of input schemes for the tested programs, and thereby reduce the potential for disagreements among them in the tests. Results include new alternative constant surface coefficients that are appropriate to the test cases and demonstrate their ability to approximate the more detailed surface heat transfer models from which they are derived.

BESTEST↗

Technical note: 21 Ne in the CoQtz-N quartz standard material

Intercomparison standards produced from mineral samples exposed to the natural cosmic ray flux are routinely used for interlaboratory comparison and normalization of measurements of the cosmogenic noble gases 3 He and 21 Ne. This effort is facilitated by the availability of multiple standard materials with a wide range of cosmogenic nuclide concentrations. The “CoQtz-N” quartz standard, which was originally produced and distributed as an intercomparison standard for cosmogenic 10 Be and 26 Al, has a significantly lower cosmogenic nuclide concentration than other mineral standards used for cosmogenic noble gas analysis and is therefore potentially useful for assessing the linearity of interlaboratory offsets across a wide range of concentrations. This paper reports 21 Ne analysis of 13 aliquots of CoQtz-N, interspersed with 14 aliquots of the commonly used CRONUS-A quartz standard, in three analytical sessions on two noble gas mass spectrometer systems. The excess 21 Ne concentration in CoQtz-N, normalized to the accepted value of 320 × 10 6 atoms g −1 for CRONUS-A, is 13.87 ± 0.24 × 10 6 atoms g −1 . Alternatively, the ratio of excess 21 Ne concentrations in CoQtz-N and CRONUS-A is 0.04330 ± 0.00077.

Balco, Greg [Lawrence Livermore National Laborator↗

New Homogeneous Standards by Atomic Layer Deposition for Synchrotron X-ray Fluorescence and Absorption Spectroscopies.

Quantification of synchrotron XRF analyses is typically done through comparisons with measurements on the NIST SRM 1832/1833 thin film standards. Unfortunately, these standards are inhomogeneous on small scales at the tens of percent level. We are synthesizing new homogeneous multilayer standards using the Atomic Layer Deposition technique and characterizing them using multiple analytical methods, including ellipsometry, Rutherford Back Scattering at Evans Analytical, Synchrotron X-ray Fluorescence (SXRF) at Advanced Photon Source (APS) Beamline 13-ID, Synchrotron X-ray Absorption Spectroscopy (XAS) at Advanced Light Source (ALS) Beamlines 11.0.2 and 5.3.2.1 and by electron microscopy techniques. Our motivation for developing much-needed cross-calibration of synchrotron techniques is borne from coordinated analyses of particles captured in the aerogel of the NASA Stardust Interstellar Dust Collector (SIDC). The Stardust Interstellar Dust Preliminary Examination (ISPE) team have characterized three sub-nanogram, {approx}1{micro}m-sized fragments considered as candidates to be the first contemporary interstellar dust ever collected, based on their chemistries and trajectories. The candidates were analyzed in small wedges of aerogel in which they were extracted from the larger collector, using high sensitivity, high spatial resolution >3 keV synchrotron x-ray fluorescence spectroscopy (SXRF) and <2 keV synchrotron x-ray transmission microscopy (STXM) during Stardust ISPE. The ISPE synchrotron techniques have complementary capabilities. Hard X-ray SXRF is sensitive to sub-fg mass of elements Z {ge} 20 (calcium) and has a spatial resolution as low as 90nm. X-ray Diffraction data were collected simultaneously with SXRF data. Soft X-ray STXM at ALS beamline 11.0.2 can detect fg-mass of most elements, including cosmochemically important oxygen, magnesium, aluminum and silicon, which are invisible to SXRF in this application. ALS beamline 11.0.2 has spatial resolution better than 25 nm. Limiting factors for Stardust STXM analyses were self-imposed limits of photon dose due to radiation damage concerns, and significant attenuation of <1500 eV X-rays by {approx}80{micro}m thick, {approx}25 mg/cm{sup 3} density silica aerogel capture medium. In practice, the ISPE team characterized the major, light elements using STXM (O, Mg, Al, Si) and the heavier minor and trace elements using SXRF. The two data sets overlapped only with minor Fe and Ni ({approx}1% mass abundance), providing few quantitative cross-checks. New improved standards for cross calibration are essential for consortium-based analyses of Stardust interstellar and cometary particles, IDPs. Indeed, they have far reaching application across the whole synchrotron-based analytical community. We have synthesized three ALD multilayers simultaneously on silicon nitride membranes and silicon and characterized them using RBS (on Si), XRF (on Si{sub 3}N{sub 4}) and STXM/XAS (holey Si{sub 3}N{sub 4}). The systems we have started to work with are Al-Zn-Fe and Y-Mg-Er. We have found these ALD multi-layers to be uniform at {micro}m- to nm scales, and have found excellent consistency between four analytical techniques so far. The ALD films can also be used as a standard for e-beam instruments, eg., TEM EELS or EDX. After some early issues with the consistency of coatings to the back-side of the membrane windows, we are confident to be able to show multi-analytical agreement to within 10%. As the precision improves, we can use the new standards to verify or improve the tabulated cross-sections.

43 PARTICLE ACCELERATORS↗