Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PROTOCOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Estimation of Anthocyanin Content of Berries by NIR Method

Anthocyanin contents of fruits were estimated by VIS spectrophotometer and compared with spectra measured by NIR spectrophotometer (600-1100 nm step 10 nm). The aim was to find a relationship between NIR method and traditional spectrophotometric method. The testing protocol, using NIR, is easier, faster and non-destructive. NIR spectra were prepared in pairs, reflectance and transmittance. A modular spectrocomputer, realized on the basis of a monochromator and peripherals Bentham Instruments Ltd (GB) and a photometric camera created at Canning Research Institute, were used. An important feature of this camera is the possibility offered for a simultaneous measurement of both transmittance and reflectance with geometry patterns T0/180 and R0/45. The collected spectra were analyzed by CAMO Unscrambler 9.1 software, with PCA, PLS, PCR methods. Based on the analyzed spectra quality and quantity sensitive calibrations were prepared. The results showed that the NIR method allows measuring of the total anthocyanin content in fresh berry fruits or processed products without destroying them.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron beam induced growth of tin whiskers

We have investigated the influence of electron irradiation on tin whisker growth. Sputtered tin samples exposed to electron beam of 6 MeV energy exhibited fast whisker growth, while control samples did not grow any whiskers. The statistics of e-beam induced whiskers was found to follow the log-normal distribution. The observed accelerated whisker growth is attributed to electrostatic effects due to charges trapped in an insulating substrate. These results offer promise for establishing whisker-related accelerated life testing protocols.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric field stimulated growth of Zn whiskers

We have investigated the impact of strong (∼10{sup 4} V/cm) electric fields on the development of Zn whiskers. The original samples, with considerable whisker infestation were cut from Zn-coated steel floors and then exposed to electric fields stresses for 10-20 hours at room temperature. We used various electric field sources, from charges accumulated in samples irradiated by: (1) the electron beam of a scanning electron microscope (SEM), (2) the electron beam of a medical linear accelerator, and (3) the ion beam of a linear accelerator; we also used (4) the electric field produced by a Van der Graaf generator. In all cases, the exposed samples exhibited a considerable (tens of percent) increase in whiskers concentration compared to the control sample. The acceleration factor defined as the ratio of the measured whisker growth rate over that in zero field, was estimated to approach several hundred. The statistics of lengths of e-beam induced whiskers was found to follow the log-normal distribution known previously for metal whiskers. The observed accelerated whisker growth is attributed to electrostatic effects. These results offer promise for establishing whisker-related accelerated life testing protocols.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Too big, too small, or just right? A benchmark assessment of density functional theory for predicting the spatial extent of the electron density of small chemical systems

Multipole moments are the first-order responses of the energy to spatial derivatives of the electric field strength. The quality of density functional theory prediction of molecular multipole moments thus characterizes errors in modeling the electron density itself, as well as the performance in describing molecules interacting with external electric fields. However, only the lowest non-zero moment is translationally invariant, making the higher-order moments origin-dependent. Therefore, instead of using the 3 × 3 quadrupole moment matrix, we utilize the translationally invariant 3 × 3 matrix of second cumulants (or spatial variances) of the electron density as the quantity of interest (denoted by K). The principal components of K are the square of the spatial extent of the electron density along each axis. A benchmark dataset of the principal components of K for 100 small molecules at the coupled cluster singles and doubles with perturbative triples at the complete basis set limit is developed, resulting in 213 independent K components. The performance of 47 popular and recent density functionals is assessed against this Var213 dataset. Several functionals, especially double hybrids, and also SCAN and SCAN0 predict reliable second cumulants, although some modern, empirically parameterized functionals yield more disappointing performance. The H, Li, and Be atoms, in particular, are challenging for nearly all methods, indicating that future functional development could benefit from the inclusion of their density information in training or testing protocols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From lab to lamp: Understanding downconverter degradation in LED packages

Downconverters, primarily inorganic phosphors, are critical components in white solid-state LED-based lighting and liquid crystal display backlights. Research efforts have led to a fundamental understanding of a downconverter's absorption, photoluminescence, and efficiency as a function of composition, structure, and processing conditions. However, considerably less work has focused on the reliability of phosphors once they are incorporated into LED packages. Solving these issues is often the final step before the commercialization of new materials, but the significant resources and time required to evaluate and mitigate materials failure are rarely discussed in the literature. In this Perspective, we discuss the need for conducting downconverter reliability testing and the potential of accelerating, screening, and understanding downconverter failure modes. Our focus highlights the mechanisms of failure and discusses how this influences materials selection and the design of different LED packages. We also stress the potential for accelerated reliability testing protocols and note the potential role first-principles calculations and data-driven models could play in establishing the compositional-processing trends for different aspects of downconverter reliability. In conclusion, we close with possible research directions that could improve downconverter reliability and emphasize the importance of assessing a material's (chemical) stability where multiple manufacturing and processing steps can dictate system performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Elucidating the G″ overshoot in soft materials with a yield transition via a time-resolved experimental strain decomposition

Significance The yielding transition in soft materials manifests macroscopically as a reversible transition from solid-like deformation to liquid-like flow under sufficiently large loading or deformation. Despite the ubiquity of materials that exhibit yielding, an understanding of the transition has remained elusive due to experimental limitations of the simple rheological tests typically used to study it. We present here a more thorough understanding of yielding, obtained via an iterative test protocol and analysis that allow for the separation of solid-like and liquid-like behaviors in the response of these materials. We show that yielding is a gradual transition, occurring to an increased extent as the deformation increases.

Donley, Gavin J.↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Certified quantum measurement of Majorana fermions

Here, we propose a quantum self-testing protocol to certify measurements of fermion parity involving Majorana fermion modes. We further show that observing a set of ideal measurement statistics implies anticommutativity of the implemented Majorana fermion parity operators, a necessary prerequisite for Majorana detection. Our protocol is robust to experimental errors. We obtain lower bounds on the fidelities of the state and measurement operators that are linear in the errors. We propose to analyze experimental outcomes in terms of a contextuality witness W , which satisfies 〈 W 〉 ≤ 3 for any classical probabilistic model of the data. A violation of the inequality witnesses quantum contextuality, and the closeness to the maximum ideal value 〈 W 〉 = 5 indicates the degree of confidence in the detection of Majorana fermions.

36 MATERIALS SCIENCE↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Application of Peracetic Acid in Poultry Processing: Effects of Treatment Dynamics and Emerging Risk of Resistance Development in Salmonella spp.

Nontyphoidal Salmonella is a leading cause of foodborne illness, with poultry representing a major source. Peracetic acid (PAA), a widely adopted antimicrobial in poultry processing, offers advantages over traditional disinfectants but has sparked interest in its combined use with other antimicrobials and potential resistance. This review evaluates the efficacy of PAA in mitigating Salmonella in combination with other food-grade antimicrobials, explores possible synergism, efficacy under varying treatment parameters, resistance development against PAA, and its role in resistance evolution. While PAA demonstrates broad-spectrum efficacy, its performance varies with environmental parameters; higher temperatures generally enhance antimicrobial action but also accelerate PAA degradation. Organic matter diminishes PAA efficacy by reactive quenching. Variability in concentration and contact time further influences outcomes. Despite its oxidative mode of action and presumed low risk for resistance, emerging studies indicate that Salmonella can develop adaptive tolerance and potential cross/coresistance following repeated or sublethal exposure to PAA. These adaptations may involve genetic upregulation of oxidative stress response pathways, efflux systems, and modifications in cell membrane integrity, raising concerns about the long-term sustainability of PAA use. Additionally, combinatorial treatments (e.g., PAA with UV-C, enzymes, or organic acids) show promise in enhancing efficacy while mitigating resistance risks. Despite recognition of PAA's safety and effectiveness, knowledge gaps remain regarding standardized resistance definitions, serotype-specific tolerance, and optimal intervention strategies in commercial settings. Therefore, there is a need for standardized testing protocols, robust studies on potential resistance, and further exploration of synergistic PAA applications to ensure sustained poultry product safety and public health protection.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Microbead Encapsulation for Protection of Electronic Components

Here, this study investigates the application of microbeads as an innovative encapsulation technique to protect electronic components from harsh mechanical strain. Traditional encapsulation methods using hard epoxy provide substantial mechanical support but create thermal expansion mismatch issues, potentially leading to electronic component failure. We explore the use of finely powdered microbeads to achieve protective structures combining stiffness and energy absorption. The research focuses on key variables, including microbead size, microbead roughness, compaction of microbeads, and circuit board mounting in the encapsulation, all of which influence the encapsulation’s effectiveness. Experimental setups and testing protocols were developed to assess the performance of various microbead materials under different impact conditions. Results demonstrate that microbead encapsulation significantly reduces strain on circuit boards, minimizing the risk of damage during mechanical shocks. However, challenges remain, such as optimizing microbead characteristics and modeling their behavior within large-scale circuit board assemblies. Despite these challenges, the findings suggest that microbead encapsulation offers a promising alternative to conventional methods, enhancing the durability and reliability of electronic components in high-stress environments.

42 ENGINEERING↗

IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119

AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit=|mean|+1.96{sigma}. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and evaluation of the MAMMI dedicated breast PET

Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV-750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

Experimental results with fuel cell start-up and shut-down. Impact of type of carbon for cathode catalyst support

Separate testing protocols for fuel cell startups and shutdowns were developed to distinguish between their effects on reverse currents and CO 2 evolution. The internal currents and the local potentials were measured with different membrane-electrode assemblies (MEAs): we examined the influence of the type of carbon for cathode catalyst support as well as the mitigating effect of low anode Pt loading. In conclusion, significant differences were observed and the experiments also confirmed previous results that the evolved CO 2 accounts for less than 25% of the total exchanged charge.

30 DIRECT ENERGY CONVERSION↗

Manufacturing Process of Electrode Films

Rotating disk electrode (RDE) experiments form a key experimental characterization technique for measuring electrocatalyst performance and durability. While standard RDE testing protocols have been documented, it has been noted that catalyst film quality can skew measurements. Furthermore, the impact of relative humidity on drying is studied in an effort to produce consistent, high quality catalyst films for RDE experiments, which shows that high quality catalyst films can be manufactured repeatedly in a controlled environment, such as inside an environmental chamber as described.

08 HYDROGEN↗

Benchmarking Solid-State Batteries Containing Sulfide Separators: Effects of Electrode Composition and Stack Pressure

Integrating sulfide separators into solid-state batteries (SSBs) containing high energy cathodes typically requires one or more materials and engineering solutions including: (i) applying interfacial coatings to mitigate electrolyte decomposition, (ii) applying high stack pressures to form robust solid-solid contacts, and (iii) using alloying anodes to avoid Li dendrite formation. Despite the promise of these approaches, a lack of standardized testing protocols makes it difficult to directly compare results among different studies. To address this problem, the present work benchmarks the performance of SSBs containing β-Li 3 PS 4 (LPS) separators and composite cathodes. By systematically varying the anode/cathode composition and stack pressure, this work demonstrates that cathode design is a major bottleneck for solid-state cells cycled at low rates (<100 µA cm -2 ). Operando stack pressure measurements show that, while mechanical confinement generally promotes higher active material utilization and cycling stability, this strategy alone does not address interfacial reactivity between LPS and high voltage cathodes. Here, these results also demonstrate that stress evolution during cycling is dominated by volume changes at the Li metal anode. Finally, we show that FeS 2 cathodes with moderate operating voltages (<3 V vs Li/Li + ) exhibit superior cycling performance compared to high voltage cathodes by facilitating formation of stable cathode/electrolyte interfaces.

25 ENERGY STORAGE↗

Baselining Activity and Stability of ORR Catalysts and Electrodes for Proton Exchange Membrane Fuel Cells for Heavy-Duty Applications

Activity and stability of electrodes with Pt and PtCo alloy catalysts supported on high surface area carbon, hereafter to as a-Pt/C and d-PtCo/C, were evaluated for heavy-duty applications. Both catalysts had nearly identical Pt loading (50-wt% Pt on carbon and 0.25 mg Pt cm −2 ) and had undergone thermal treatment to stabilize them by growing the average particle size to 4–5 nm. Both were subjected to 90,000 (90 k) standard accelerated stress tests (AST) cycles consisting of 0.6–0.95 V square wave potentials, 3-s hold at upper and lower potential limits in H 2 /N 2 at 1.5 atm, 80 °C and 100% RH. Test protocols were developed to monitor the performance losses and characterize them in terms of activity for the oxygen reduction reaction (ORR), oxygen transport in the electrode and proton transport in the membrane and cathode catalyst layer. Despite the nearly double initial ORR activity, the PtCo/C electrode degraded faster due to the leaching of Co from the catalyst that had started even before the imposition of the AST potential cycles. Commensurate with Co leaching, Co poisoning of ionomer is responsible for the inferior performance of d-PtCo/C electrode at high current densities both before and after AST.

30 DIRECT ENERGY CONVERSION↗