Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Single electron–hole pair sensitive silicon detector with surface event discrimination

Here, we demonstrate single electron-hole pair resolution in a single-sided, contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a baseline energy resolution of 3 eV. This crystal can be operated at voltages in excess of $\pm50$ V, resulting in a measured charge resolution of 0.06 electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device allows for the discrimination of surface events and separation of events occurring near the center of the detector from those near the edge. We use this discrimination ability to show that dark events seen in previous detectors of a similar design are likely dominated by charge leakage along the side wall of the device. We saw only a small reduction in dark event rate with this biasing scheme, further suggesting that sidewall and edge-dominated processes are responsible for the majority of these events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

Snowmass2021 CMB-HD White Paper

CMB-HD is a proposed millimeter-wave survey over half the sky that would be ultra-deep (0.5 uK-arcmin) and have unprecedented resolution (15 arcseconds at 150 GHz). Such a survey would answer many outstanding questions about the fundamental physics of the Universe. Major advances would be 1.) the use of gravitational lensing of the primordial microwave background to map the distribution of matter on small scales (k~10 h Mpc^(-1)), which probes dark matter particle properties. It will also allow 2.) measurements of the thermal and kinetic Sunyaev-Zel'dovich effects on small scales to map the gas density and velocity, another probe of cosmic structure. In addition, CMB-HD would allow us to cross critical thresholds: 3.) ruling out or detecting any new, light (< 0.1 eV) particles that were in thermal equilibrium with known particles in the early Universe, 4.) testing a wide class of multi-field models that could explain an epoch of inflation in the early Universe, and 5.) ruling out or detecting inflationary magnetic fields. CMB-HD would also provide world-leading constraints on 6.) axion-like particles, 7.) cosmic birefringence, 8.) the sum of the neutrino masses, and 9.) the dark energy equation of state. The CMB-HD survey would be delivered in 7.5 years of observing 20,000 square degrees of sky, using two new 30-meter-class off-axis crossed Dragone telescopes to be located at Cerro Toco in the Atacama Desert. Each telescope would field 800,000 detectors (200,000 pixels), for a total of 1.6 million detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CMS HGCAL ECON-D ASIC : Impact of CMOS fabrication process tuning on performance and radiation tolerance

The CMS experiment’s High Granularity Calorimeter (HGCAL) upgrade will replace CMS’s existing endcap calorimeters in preparation for the High Luminosity LHC. To effectively use over 6 million channels of this “imaging”calorimeter, CMS has developed two novel Endcap Concentrator (ECON) ASICs to perform data compression/selection on detector. The ECON-D ASIC operates on the 750kHz data path, and the ECON-T ASIC on the 40MHz trigger path. These 65 nm CMOS ASICs are radiation tolerant to 200 Mrad and low power, operating at less than 2.5 mW/channel. The first full-functionality prototype ECONs were produced and characterized in 2021-23, and an initial engineering run was performed in 2024. ECON-D radiation testing for the engineering run revealed that the chip’s internal SRAMs produce intermittent read errors for a non-negligible fraction of chips. Further investigation indicated that the SRAM performance is highly sensitive to the exact parameters of the CMOS fabrication process. To both study this process sensitivity and mitigate SRAM performance issues, twenty ECON wafers were produced in 2025 with a range of doping concentrations designed to tune the underlying transistor threshold voltage by 0%, 5%, 10%, and 15% from nominal. This talk will present first measurements of ECON-D performance, power consumption, and radiation tolerance for these four variations of CMOS process.

Syal, Chinar [Fermilab]↗

Search for high-mass resonances in final states with a τ-lepton and missing transverse momentum with the ATLAS detector

A search for high-mass resonances decaying into a τ-lepton and a neutrino using proton-proton collisions at a center-of-mass energy of $\sqrt{s}$ =13 TeV is presented. The full run 2 data sample corresponding to an integrated luminosity of 139 fb -1 recorded by the ATLAS experiment in the years 2015–2018 is analyzed. The τ-lepton is reconstructed in its hadronic decay modes and the total transverse momentum carried out by neutrinos is inferred from the reconstructed missing transverse momentum. The search for new physics is performed on the transverse mass between the τ-lepton and the missing transverse momentum. No excess of events above the Standard Model expectation is observed and upper exclusion limits are set on the W' →τ⁢v production cross section. Heavy W' vector bosons with masses up to 5.0 TeV are excluded at 95% confidence level, assuming that they have the same couplings as the Standard Model W boson. For nonuniversal couplings, W' bosons are excluded for masses less than 3.5–5.0 TeV, depending on the model parameters. In addition, model-independent limits on the visible cross section times branching ratio are determined as a function of the lower threshold on the transverse mass of the τ-lepton and missing transverse momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for CE ν NS and physics beyond the standard model using Skipper-CCDs at CONNIE

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering ( CE ν NS ) of reactor antineutrinos off silicon nuclei using thick fully depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with subelectron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipper-CCDs for reactor neutrino detection. We report on the performance of the Skipper-CCDs, the new data processing, data quality, and event selection for CE ν NS interactions, which enable CONNIE to reach a record low detection threshold of 15 eV. The data were collected over 300 days in 2021–2022 and correspond to exposures of 14.9 g-days with the reactor-on and 3.5 g-days with the reactor-off. The difference between the reactor-on and off event rates shows no excess and yields upper limits for the neutrino interaction rates, comparable with previous CONNIE limits from standard CCDs and higher exposures. Searches for new neutrino interactions beyond the Standard Model improve the previous CONNIE limit on a simplified model with light vector mediators. A first dark matter (DM) search by diurnal modulation by CONNIE obtains the best limits on the DM-electron scattering cross section by a surface-level experiment. These promising results, obtained using a very small-mass sensor, illustrate the potential of Skipper-CCDs to probe rare neutrino interactions and motivate the plans to increase the detector mass in the near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-proton decay from α-cluster states in 10 C and 11 N

Two-proton decay from excited states in 10 C and 11 N has been characterized from an analysis of the 2p + 2α and 3p + 2α exit channels. Data from four previously published invariant-mass studies associated with inelastic excitation, multinucleon knockout, and neutron pickup reactions have been considered. A rotational band in 10 C was identified built on the second 0 + state which has strong α-cluster molecular structure. The members of this band were tentatively identified up to J π = 4 + and all identified states have a prompt 2p decay branch. The spins of the 0 + and 2 + members were deduced from comparisons of the momentum correlations in their 2p branches to those from known 2p emitters. The 2 + and the tentative 4 + members are both above the α threshold and exhibit large reduced decay widths for α emission. This band exhibits a similar moment of inertia to its analog in the mirror nucleus 10 Be. Evidence is also presented for a molecular band in 11 N built on the second 3/2 – state which 2p decays. Furthermore, tentative members of this band have been assigned up to J π = 9/2 – and their excitation energies also match their likely analogs in the mirror nucleus 11 Be.

6 ≤ A ≤ 19↗

Benefits of MeV-scale reconstruction capabilities in large liquid argon time projection chambers

Using truth-level Monte Carlo simulations of particle interactions in a large volume of liquid argon, we demonstrate physics capabilities enabled by reconstruction of topologically compact and isolated low-energy features, or “blips,” in large liquid argon time projection chamber (LArTPC) events. These features are mostly produced by electron products of photon interactions depositing ionization energy. The blip identification capability of the LArTPC is enabled by its unique combination of size, position resolution precision, and low energy thresholds. Here, we show that consideration of reconstructed blips in LArTPC physics analyses can result in substantial improvements in calorimetry for neutrino and new physics interactions and for final-state particles ranging in energy from the MeV to the GeV scale. Blip activity analysis is also shown to enable discrimination between interaction channels and final-state particle types. In addition to demonstrating these gains in calorimetry and discrimination, some limitations of blip reconstruction capabilities and physics outcomes are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wasserstein Normalized Autoencoder for Anomaly Detection in ProtoDUNE Vertical-Drift Detector

ProtoDUNE Vertical Drift needs a selective triggering algorithm. The detector sits on Earth's surface, so cosmic activity dominates its data. Our goal in this paper is to trigger on neutrino events more robustly than the current deployed Analog-to-Digital Converter Simple Window (ADCSW) model and, eventually, search for signals of Beyond Standard Model (BSM) physics at DUNE as our ultimate North Star objective. As a step towards this goal, we evaluate a Wasserstein Normalized Autoencoder (WNAE) on simulated collection-plane only windows of shape $1\times10\times10$ where Neutrinos act as our BSM-proxy and Cosmic-ray Muons serve as our learned background. The network parameters are fitted using only cosmic-ray muon events as background in order to maintain an unsupervised pipeline. Training uses finite-step Langevin $x^-$ samples, positive-sample reconstruction energy, and an empirical sliced $2$-Wasserstein objective to learn a normalized Boltzmann energy model. We then calibrate on a nominal $5\,\mathrm{Hz}$ operating threshold calculated from cosmic validation data. Both WNAE and ADCSW accept 311 of 194,083 held-out cosmic background events at this $5\,\mathrm{Hz}$ threshold. We found that WNAE accepts 9,677 of 34,634 neutrino-proxy events $(27.9\pm0.24)\%$, compared with 10,076 $(29.1\pm0.24)\%$ for ADCSW, an observed WNAE-minus-ADCSW difference of $-1.15\%$. At another nominal $2\,\mathrm{Hz}$ target threshold, the corresponding efficiencies are $(20.5\pm0.22)\%$ and $(22.6\pm0.22)\%$, respectively. Of the WNAE-selected neutrino proxies at $5\,\mathrm{Hz}$, $(20.8\pm0.4)\%$ of the classified neutrino-proxy events are unique to WNAE, where the uncertainty is an absolute binomial standard error of $0.4\%$.

Zheng, Jake [U. Chicago (main)] (ORCID:00090002189↗

Wasserstein Normalized Autoencoder for Anomaly Detection in ProtoDUNE Vertical-Drift Detector

ProtoDUNE Vertical Drift needs a selective triggering algorithm. The detector sits on Earth's surface, so cosmic activity dominates its data. Our goal in this paper is to trigger on neutrino events more robustly than the current deployed Analog-to-Digital Converter Simple Window (ADCSW) model and, eventually, search for signals of Beyond Standard Model (BSM) physics at DUNE as our ultimate North Star objective. As a step towards this goal, we evaluate a Wasserstein Normalized Autoencoder (WNAE) on simulated collection-plane only windows of shape $1\times10\times10$ where Neutrinos act as our BSM-proxy and Cosmic-ray Muons serve as our learned background. The network parameters are fitted using only cosmic-ray muon events as background in order to maintain an unsupervised pipeline. Training uses finite-step Langevin $x^-$ samples, positive-sample reconstruction energy, and an empirical sliced $2$-Wasserstein objective to learn a normalized Boltzmann energy model. We then calibrate on a nominal $5\,\mathrm{Hz}$ operating threshold calculated from cosmic validation data. Both WNAE and ADCSW accept 311 of 194,083 held-out cosmic background events at this $5\,\mathrm{Hz}$ threshold. We found that WNAE accepts 9,677 of 34,634 neutrino-proxy events $(27.9\pm0.24)\%$, compared with 10,076 $(29.1\pm0.24)\%$ for ADCSW, an observed WNAE-minus-ADCSW difference of $-1.15\%$. At another nominal $2\,\mathrm{Hz}$ target threshold, the corresponding efficiencies are $(20.5\pm0.22)\%$ and $(22.6\pm0.22)\%$, respectively. Of the WNAE-selected neutrino proxies at $5\,\mathrm{Hz}$, $(20.8\pm0.4)\%$ of the classified neutrino-proxy events are unique to WNAE, where the uncertainty is an absolute binomial standard error of $0.4\%$.

Zheng, Jake [Chicago U.] (ORCID:0009000218901379)↗

Fusion of 12 C+ 24 Mg far below the barrier: Evidence for the hindrance effect

Background: The phenomenon of fusion hindrance may have important consequences on the nuclear processes occurring in astrophysical scenarios, if it is a general behavior of heavy-ion fusion at extreme subbarrier energies, including reactions involving lighter systems, e.g., reactions in the carbon and oxygen burning stages of heavy stars. The hindrance is generally identified by the observation of a maximum of the S-factor vs energy. Whether there is an S-factor maximum at very low energies for systems with a positive fusion Q value is an experimentally challenging question. Purpose: Our aim has been to search for evidence of fusion hindrance in 12 C+ 24 Mg which is a medium-light m system with positive Q value for fusion, besides the heavier cases where hindrance is recognized to be a general phenomenon. 12 C+ 24 Mg is very close to the 16 O + 16 O and 12 C + 12 C systems that are important for the late evolution of heavy stars. Methods: The experiment has been performed in inverse kinematics using the 24 Mg beam from the XTU Tandem accelerator of LNL in the energy range 26-52 MeV with an intensity of 4-8 pnA. The targets were 12 C evaporations 50 mu g/cm 2 thick, isotopically enriched to 99.9%. The fusion-evaporation residues were detected at small angles by a E-Delta E-ToF detector telescope following an electrostatic beam deflector. Results: Previous measurements of fusion cross section for 12 C+ 24 Mg were limited to above-barrier energies. In the present experiment the excitation function has been extended down to similar or equal to 15 mu b and it appears that the S factor develops a clear maximum vs energy, indicating the presence of hindrance. This is the first convincing evidence of an S factor maximum in a medium-light system with a positive fusion Q value. These results have been fitted following a recently suggested method and a detailed analysis within the coupled-channels model that has been performed using a Woods-Saxon potential and including the ground state rotational band of 24 Mg. The coupled-channels calculations give a good account of the data near and above the barrier but overpredict the cross sections at very low energies. Conclusions: The hindrance phenomenon is clearly observed in 12 C+ 24 Mg, and its energy threshold is in reasonable agreement with the systematics observed for several medium-light systems. The fusion cross sections at the hindrance threshold show that the highest value (sigma(s) = 1.6 mb) is indeed found for this system. Therefore it may even be possible to extend the measurements further down in energy to better establish the position of the S-factor maximum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlated $\ n-γ$ angular distributions from the $\ Q$ = 4.4398 MeV 12 C ($\ n, n' γ$) reaction for incident neutron energies from 6.5 MeV to 16.5 MeV

Neutron scattering cross sections and angular distributions represent one of the most glaring sources of uncertainty in calculations of nuclear systems. Even simple nuclei like 12 C show indications of errors in nuclear databases for scattering reactions. Measurements of inelastic neutron scattering have historically measured either the scattered neutrons or the nuclear deexcitation $\ γ$ emission. Only a very small number of experiments attempted correlated measurements of both the neutron and $\ γ$ data simultaneously, even though these $\ n-γ$ correlations could be essential for understanding particle transport in nuclear systems. In this work we describe a measurement of the $\ n, γ$, and correlated $\ n-γ$ angular distributions from the $\ Q$ = 4.4398 MeV 12 C ($\ n, n'γ$) reaction in a single experiment using an EJ-309 liquid scintillator detector array with wide angular coverage, and with a continuous incident neutron energy range from 6.5 to 16.5 MeV. We also provide a thorough covariance description of these results, including normalization of the probability distribution. While the measured n distributions agree well with the relatively large number of available literature measurements, there are comparatively very few measurements of the γ distributions from this reaction. However, our data support the presence of a nonzero α 4 Legendre polynomial component of the γ angular distribution suggested in past measurements, which is currently not incorporated in the ENDF/B-VIII.0 library despite the use of these same literature data for evaluation of the 12 C ($\ n, n'γ$) cross section. The correlated $\ n-γ$ distribution measurements are limited to three measurements at incident neutron energies near 14 MeV. Our results do not generally agree with any of these literature measurements. We observe clear indications of significant changes in the $\ n$ distribution for specific $\ γ$-detection angles and vice versa especially near thresholds for other reaction channels, which shows the potential for significant bias in experiments that, for example, tag on inelastic scattering using a single or small number of $\ γ$ -detection angles and could impact particle transport calculations.

6 ≤ A ≤ 19↗

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗

Search for Wγ resonances in proton-proton collisions at √s=13 TeV using hadronic decays of Lorentz-boosted W bosons

A search for W$\gamma$ resonances in the mass range between 0.7 and 6.0 TeV is presented. The W boson is reconstructed via its hadronic decays, with the final-state products forming a single large-radius jet, owing to a high Lorentz boost of the W boson. The search is based on proton-proton collision data at $\sqrt{s} = $ 13 TeV, corresponding to an integrated luminosity of 137 fb$^{-1}$, collected with the CMS detector at the LHC in 2016-2018. The W$\gamma$ mass spectrum is parameterized with a smoothly falling background function and examined for the presence of resonance-like signals. No significant excess above the predicted background is observed. Model-specific upper limits at 95% confidence level on the product of the cross section and branching fraction to the W$\gamma$ channel are set. Limits for narrow resonances and for resonances with an intrinsic width equal to 5% of their mass, for spin-0 and spin-1 hypotheses, range between 0.17 fb at 6.0 TeV and 55 fb at 0.7 TeV. These are the most restrictive limits to date on the existence of such resonances. In specific narrow-resonance benchmark models, heavy scalar (vector) triplet resonances with masses between 0.75 (1.15) and 1.40 (1.36) TeV are excluded for a range of model parameters. Model-independent limits on the product of the cross section, signal acceptance, and branching fraction to the W$\gamma$ channel are set for minimum W$\gamma$ mass thresholds between 1.5 and 8.0 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗